A8GS-T Minimum size class in the industry Remote Reset Rocker Switch with Delay OFF Function

Similar documents
Number of poles 1-pole 2-pole Minimum Enclosure Contact. G2R-1AZ G2R-1Z DC Fully sealed G2R-1AZ4 G2R-1Z4 G2R-1A-E G2R-1-E

Sealed long stroke slide-contact switch for reliable ON/OFF action even in severe environmental conditions.

Tactile Switch B3F Through-hole-mounting Switches in a Wide Range of Models: 6 6 mm, 12

3. Terminal Shape P : PCB terminals FS: Surface-mounting terminals, short FL : Surface-mounting terminals, long

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information

POWER ROCKER SWITCH UL, CSA, VDE, TÜV, ÖVE, KEMA, SEMKO, NEMKO, DEMKO, FIMKO, SEV UL, CSA, VDE, TÜV, SEMKO, NEMKO, DEMKO, FIMKO, SEV, KEMA, ÖVE

VAQ. Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment. Pushbutton Switch (Cylindrical 10.5-dia.

MICRO SWITCH EJF SERIES

1 POLE 5 A (CADMIUM FREE CONTACTS TYPE) NY SERIES

DISCONTINUED (1998) FBR46 SERIES. MINIATURE RELAY 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) RoHS compliant FEATURES

CQM1-SF200/CS1W-SF200

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Model Number Legend. Application Examples. Surface Mounting Relay

Surface Mounting Relay

1 POLE - 5A SLIM POWER RELAY

DLP-PU/E Instruction Manual

XG2. Flat Cable Connectors for PCBs. Achieve Total Cost Reduction through High-density Mounting and Reduced Wiring. Terminal Arrangement

A SERIES. 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) MINIATURE RELAY. RoHS compliant

SERIES SINGLE POLE AND DOUBLE POLE ROCKER SWITCHES UP TO 12 (4) A 250 V~ AND 8 (8) A 250 V~

Type Sealing Poles Contacts Rated voltage Model Standard d Flux-tight 4 poles oes 3PST-NO, SPST-NC 24 VDC G7SA-3A1B 3PST-NO, 3PST-NC

G7SA. Ordering Information. Slim Plug-In Safety Relay. Slim Safety Relay for Machine Control. H Slim body only 13 x 24 x 50 mm

SPST-NO SPDT DPST-NO DPDT

SPST-NO SPDT DPST-NO DPDT

RY2 miniature industrial relays

DATA SHEET COMPACT AND LIGHTWEIGHT, SMALL MOUNTING SIZE, HIGH BREAKDOWN VOLTAGE

1 POLE - 16A / Inrush 120A relay. (a) Relay type FTR-K1 : FTR-K1 Series (b) Contact configuration A : 1 form A C : 1 form C

HL Economical, Miniature Limit Switch Boasting Rigid Construction. General-purpose Limit Switch. Model Number Structure.

Liquid Leakage Sensor Amplifier

1 POLE - 16A 80A Inrush type. (b) Contact configuration A : 1 form A (SPST-NO) C : 1 form C (SPDT) (standard type "K" only)

Ordering Information. Latching Relay G2AK. Model Number Legend Magnetic Latching Version of G2A Ideal for Sequence Control

PCB Relay. LED indicator G2R-1A3-SN G2R-13-SN contact) LED indicator and diode DC G2R-1A3-SND G2R-13-SND

Model Number Structure

4 A CAPACITY, THE VARIETY OF CONTACT ARRANGEMENTS FEATURES

AZ420 MINIATURE GENERAL PURPOSE RELAY

ONE OF THE SMALLEST SNAP-ACTION SWITCHES IN THE WORLD. FEATURES Superminiature type, light-weight snap action switch PC board terminal type (0.

Surface Mounting Relay

PA5. Series. Quick-Connect Cables with Connectors. Simplifies sensor wiring. Wide variety of connectors attached to cables.

How To Read A Pipe From A Sensor

DISCONTINUED (2012) VB SERIES 2 POLE 5 A (MEDIUM LOAD CONTROL) POWER RELAY. RoHS compliant

Model Number Structure

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

NA Series. 2 POLES - 1 to 2 A (For Signal Switching) MINIATURE RELAY FTR-K1 SERIES

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

E2FM. Inductive Proximity Sensor in full metal housing. Application. Continuous Impact Test. Brush Test

DISCONTINUED (2009) RA SERIES. 2 POLES 1 to 2 A (FOR SIGNAL SWITCHING) MINIATURE RELAY. RoHS compliant

Solid-State Timer H3G

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Operating Temperature Range: -30 to +85ç (Note 1) Operating Humidity Range: 40 to 80%

Power Supplies 3. SDN-P DIN Rail Series

EE-SPY801/802. Photomicrosensors for detecting wafer-carrier mounting. Wafer-carrier Mounting Photomicrosensors. Ordering Information.

Ordering Information. Cylindrical Proximity Sensor E2E/E2E2

SILENT POWER RELAY. FTR-H3 Series. 1 POLE - 78A/120A Inrush Current Type FTR-K1 SERIES FEATURES

Cross-beam scanning system to detect slim objects. 100 mm in

Type Contact material Contact form Construction Model General purpose AgCdO SPDT Semi-sealed G2R-1

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

POWER RELAY. FTR-K1-KS Series. 1 POLE - 16A / Inrush 120A relay FTR-K1 SERIES FEATURES

DISCONTINUED (1998) MINIATURE RELAY 1 POLE 1 to 2 A (FOR SIGNAL SWITCHING) FBR211 SERIES. RoHS compliant

The Best Relaytion. Reed Relays Rev. B EC-JM ECOC: JM10 1. Aug. 04

No. : EX##-OMF0004 OPERATION MANUAL. SI unit EX12#-SMB1

RISH EM 3490 DS Dual Source Energy Meter RISH EM 3490 DS. Application : Product Features:

TQ SMD RELAYS TQ SMD LOW-PROFILE SURFACE-MOUNT RELAY FEATURES SPECIFICATIONS

KSC Series Sealed Tact Switch for SMT

MINIATURE SURFACE MOUNT RELAY

E2EL Ø 6,5 M8 / Plug M8 M8 / Plug M12 E2EL

General-purpose Relay

SZR-LY Series. General Purpose Power Relay WARNING WARNING. Sensing and Control

1 POLE - 16A 80A Inrush type. (a) Relay type FTR-K1 : FTR-K1-Series

POWER RELAY. JV Series. 1 POLE - 5A/10A Medium Load Control FTR-K1 SERIES FEATURES

7.5 Watt AC-DC Switch Power Supply

Part number NPN E2EM-X2C1 E2EM-X2C2 PNP E2EM-X2B1 E2EM-X2B2 NPN E2EM-X4C1 E2EM-X4C2 PNP E2EM-X4B1 E2EM-X4B2

Product Specification

DUCT SMOKE DETECTOR D4120

February Chip Beads. For power line. HF-ACC Series. HFxxACC3216. * Dimensions Code JIS[EIA]

Signaling Lights. LH Series Surface Mount Indicators. Part Numbers. Jumbo Dome (one color) Jumbo Dome (two color)

2 POLES - 5A LOW PROFILE TYPE

3. ELECTRICAL PERFORMANCE PROPERTY TEST CONDITION PERFORMANCE 3. 1 Contact Resistance 1) Center Push 100mΩ Max

MAXIMUM LOAD CURRENT 1 A SN SERIES

Thermal-Magnetic Circuit Breaker M1-..

Goodsky Technical Data. Contact Details

650W Single Output Power Supply

Programmable Terminal. NPSeries. Easy Setup with the Low-cost, Compact NP Series

SENSORS. Fiber Optic Sensors - S70. Advanced fiber optic amplifiers for high speed and low contrast applications

Solid State Relays for Heaters

November terminal Filters. For signal line. MEM series. * Dimensions Code JIS[EIA]

(e) Enclosure B : Flux proof type, RTII C : Plastic sealed type (with tape), RTIII K : Plastic sealed type, RTIII

Monitor and control the sensors through network. supported OPTEX FA CO., LTD. Remote controlling of fiber sensors. Reduces wires and saves space

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

GP2Y0A02YK0F. Distance Measuring Sensor Unit Measuring distance: 20 to 150 cm Analog output type GP2Y0A02YK0F

FP2 Relay. The Best Relaytion

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Detector transparent with Color Inserts. FAA 500 TR P Trim Ring transparent with Color Inserts. FCA 500 / FCA 500 E Detector Bases

Telefon (+45) Telefax (+45) Installation and operating manual

Count input Display Time range h or 3999d23.9h (selectable) 999h59m59s or 9999h59.9m (selectable) 3. Case Color B: Black

Preset Counter signo 721

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

MP-1919 XNOVA Cube TM SMD LED

Duct Humidity Transmitter

DSD 70 Dual Channel Hall Effect Speed Sensor for Railway Applications, compliant with EN 50155

Two Position Cable-to-Board Power Connector System (Right Angle/Straight) with Coding Contacts

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Transcription:

New Product Delay Rocker Switch A8GS-T Minimum size class in the industry Remote Reset Rocker Switch with Delay Function Rocker switch with Delay Function. Switch is kept to turn, even if button is operated to turn, and Switch is turned by external signal. Zero standby power with Reset function, switching by external signal. Preventing from application trouble such as a data lost or circuit damage by forced power. Timing control of main power switch turn for safety application design with Delay function. Contact gap of 3 mm minimum. UL and cul standard approved, Conforming to EN standards. RoHS Compliant (Please refer the Precautions) Usage example Saving energy by cutting standby power. Saving energy by preventing forgetting turn main power. Turning main power by remote. Turning main power of many equipments at the same time. Timing control of main power switch turn for safety design. Preventing from circuit and data damage by power flicker. * There are 2 kinds of main models A8GS. (Delay Function model and Remote Reset model) With regard to the models with Delay Function, please refer to the other catalog. List of Models Contact Form 1 to 4: contact terminal a, b: Signal contact terminal +, -: Coil terminal Terminals Marking on caps Signal Contact Terminal: SPST + Contact Terminal: DPST Signal Contact Terminal 1 + Contact Terminal 2 + 1 2-3 4 Signal Contact Terminal: CT Connector Signal Contact Terminal: CT Connector Contact Terminal: Quick-connect Contact Terminal: Solder terminals terminals #187(t=0.8) No Marking A8GS-T1185K A8GS-T1115K A8GS-T1285K A8GS-T1215K A8GS-T1385K A8GS-T1315K Quantity per box 50 Note: 1. This is not general 3 pole switch. (1) Signal contact terminal is only for detecting button /. (2) contact terminal is for turning / of circuit. Switch is turned by external signal only, after turning of button. 1

A8GS-T Ratings Contact Ratings Contact Terminal Signal Contact Terminal 5 VDC 0.2 A Note: 1. The above ratings were tested under the following conditions: (1) Ambient temperature : 20 ± 2 C (2) Ambient humidity : 65 ± 5 % RH (3) Switching frequency : 7 times/min Reset Coil Ratings Rated voltage, current Rated voltage Rated current (Resistive load) 125 VAC 16 A 250 VAC 10 A Operating voltage range Rated usage cycle Coil resistance (Coil temperature: 20 ± 2 C) : 50 to 100 ms 5 VDC 455 ma 4.5 to 5.5 VDC 11 Ω ± 20 % : Min 5 sec Note: 1. Voltage for coil should be set within operating voltage range and applied time should be within rated usage cycle. Otherwise the performance of the coil may be deteriorated. Note: 2. In case of applying voltage within the range from 5.5 to 24 VDC to the coil, contact your OMR sales representative. Contact specifications Signal contact contact Material Gold alloy Silver alloy Contact gap 3 mm 3 mm Minimum applicable load (Reference value) * 3 VDC 1 ma 5 VDC 200 ma * Please refer to '' Using Micro loads'' in ''Precautions'' for more information on the minimum applicable load. Characteristics Permissible operating Mechanical Switch operation: 20 times/min max, Coil operation: 7 times/min max frequency Electrical 7 times/min max Insulation resistance 100 MΩ min (at 500 VDC with insulation tester) Contact resistance contact terminal 100 mω max (6 VDC to 8 V, 1 A Voltage drop method) (initial value) Signal contact terminal 100 mω max (6 VDC to 8 V, 0.1 A Voltage drop method) Between terminals of the same polarity 2,000 VAC 50/60 Hz 1 min Dielectric strength Between terminals of the different polarity 2,000 VAC 50/60 Hz 1 min Between each terminals of the switch and terminals of coil 4,000 VAC 50/60 Hz 1 min Between each terminals of switch and ground 4,000 VAC 50/60 Hz 1 min Vibration resistance * Malfunction 10 to 55 Hz 1.5 mm double amplitude (Malfunction 1 ms max) Shock resistance * Malfunction 300 m/s 2 min (Malfunction 1 ms max) Destruction 1000 m/s 2 max Ambient operating temperature 10 to +55 C (with no icing or condensation, 60 % RH max) Ambient operating humidity 90 % RH max (+5 to 35 C with no icing or condensation) Durability Mechanical Switch operation: 30,000 operations min, Coil operation: 10,000 operations min Electrical Switch operation: 10,000 operations min, Coil operation: 10,000 operations min Degree of protection IEC IP40 Contact release time ** 100 ms max Weight A8GS-TxxxxK: Around 15 g Note: 1. Above specification values are initial values. * For the testing condition in individual specification, contact your OMR sales representative. ** Time from voltage applied to reset coil to actual contacts opening. 2

Approved Safety Standards UL (UL61058-1) TÜV (EN61058-1) Approved safety Approved safety standards ratings standards ratings contact terminal 16 A 125 VAC contact terminal 10(4) A 250 VAC 10 A 250 VAC Signal contact terminal 0.2 A 5 VDC Signal contact terminal Note: 1. There are no approved models of TV-8 rating for Delay Function models. A8GS-T Connector for Signal Switch Circuit and Coil Circuit CT connectors produced by Tyco Electronics Corporation or XR connectors produced by JST shall be used for connection of Signal and Coil circuit. Other connectors shall not be used. Connector Terminal no. Connection with Switch 1 a (Switch COM) Signal 2 --- contact terminal 3 b (Switch NO) 1 + (Coil) Coil terminal 2 - (Coil) * @ indicates Housing color. Housing 179228-3 Tyco Electronics Corporation: CT connecter Pressure welding type Contact JST: XR Connector Cramping type AWG #30-26 AWG #26-22 AWG #28-26 AWG #24 AWG #28-26 173977-3 2-179694-3 03XR-6@-P* 179609-1 179227-1 179228-2 173977-2 2-179694-2 02XR-6@-P* 3

A8GS-T Operation Delay Function contacts are kept in status, even if button is operated to turn by manual operation of button. And Switch is turned by external signal to coil embedded in switch. (1) Signal contact terminal and contact terminal are turned by manual operation of button. (2) contact terminal is kept in status, even if button is operated to turn by manual operation. Only Signal contact terminal is turned. (3) contact terminal is turned when external signal is applied to coil. Furthermore, it is able to turn both signal and power contact terminals from manual condition at the same time by applying voltage to coil as Remote Reset Function. Delay Function Operation (1) Manual (2) Manual (3) Delay Button operating condition switch terminal is returned automatically. Signal contact terminal contact terminal Coil terminal Remote Reset Function Operation No voltage applied Voltage applied No voltage applied Button operating condition (1) Manual (3) Remote Reset Button is returned automatically. Signal contact terminal contact terminal Coil terminal No voltage applied No voltage applied Note: 1. Once switch is turned, contact terminal is not able to be turned by manual operation. Please apply the voltage to the coil in order to turn switch circuit. Switch circuit and operating condition Voltage applied (1) Manual (2) Manual (3) Delay / Remote Reset + 1 2 + 1 2 + 1 2 + 1 2-3 4 Load1-3 4 Load1-3 4 Load1-3 4 Load1 supply 1 supply 1 supply 1 supply 1 Load2 Load2 Load2 Load2 supply 2 supply 2 supply 2 supply 2 *5 VDC applied to coil terminal 4

Dimensions (Unit: mm) /Operating Characteristics A8GS-T A8GS-T1@ 85K 2 19.2 16.5 28. 5 6. 9 22 30 1.3 27 10 4.75 0.8 15.8±0.8 18.6 CT Connector Operating force (OF) 1.8 ± 1.4 N CT Connector Note: 1. Note: 2. Note: 3. Note: 4. Unless otherwise specified, a tolerance of ± 0.4 mm applies to all dimensions. At initial operation or operation after reset, operating force is increased, due to switch structure. Solder terminals model has different hole shape, comparing with Quick-connect terminals. Outline and characteristics are same. No models of switch without delay off function (without coil), due to product design. Panel Cutout Panel thickness: 0.8 to 2.3 mm 27.7 ±0.1 R by cutting Panel cutout design is for prevention of false insertion. Please be careful about the direction of the protrusion. The rollover of the panel shall be on the front face. And panel back side shall be Edge shape by processing. 4.3 ±0.1 1.9 ±0.1 26.5 ±0.1 19.5 ±0.1 (Operating surface direction) Edge Note: 1. Recommendation panel material is "SPCC", however, in case of soft material or Panel back side shape is not edge, mounting strength may down. Please check and try by actual mounting panel and set the Panel thickness and hole dimension. 5

A8GS-T Precautions WARNING Do not wire the switch or touch any terminal of the Switch while power is being supplied. Or it may result in electric shock. Cautions Use the switch within the rated voltage and current ranges, otherwise the switch may have deteriorated durability radiate heat, or burn out. This particularly applies to the instantaneous voltages and currents when switching. Caution of usage Mounting Easy to mount by snap fitting. Do not impose excessive force on switch at the time of panel mounting. Do not detach the switch after installed. Otherwise, the holding strength may be loose. Apply the force to housing when installing to panel. Do not apply the force to the button (rocker) part when installing to the panel. Pushing position Wiring Confirm the size of the receptacles and be sure to connect them firmly. Use an appropriate wire allowable to carry current. Be sure that there is no mechanical stress on terminals and coil terminals.otherwise, the switch may malfunction and/or damaged. (Example: Too strong wiring) Handling Do not apply excessive operating force to the switch. Do not drop or apply the excessive shock. Otherwise the switch may be damaged or deformed. Do not impose force to operating part from an angle, Otherwise the switch may be damaged or deformed. Correct Incorrect Environment for storage and use To prevent the terminals color change and others while storage, Do not keep for a long term in the following conditions. (1) High temperature, high humid environment (2) Corrosive gas (3) The place where the direct rays of the sun (4) The place where the sereeze (5) Environmental with a sudden temperature change This switch is not sealed to prevent from entering dust and liquid.do not use under dust and liquid condition. Switch shall not be icing or condensation. Strong magnetic field may cause malfunction. Check function is recommended under practical use conditions. Using Micro Loads In case of using the switch under the micro loads, please refer the Minimum applicable load and set the load more than minimum applicable load. Even when using micro load within the operating range, if inrush current occurs, it may increase contact wear and so deteriorate durability.therefore, insert a contact protection circuit where necessary. The minimum applicable load is the L-level reference value. This value indicates the malfunction reference level for the reliability level of 60 %. (λ 60) The equation, λ 60 = 0.5 x 10-6 /operations indicates that the estimated malfunction rate is less than 1/2,000,000 operations with a reliability level of 60 %. Take appropriate insulation distance between switch terminal and other metal parts after wiring. Coil has polarity, please confirm polarity when wiring. Do not apply continuous voltage more than 10 seconds at any time. Otherwise, insulation deterioration may occur by heat of coil. Please consider the circuit design. Reverse voltage may cause of accurate discrete semiconductor devices. In case of controlling by accurate discrete semiconductor devices, Please consider the circuit design. (Example : add the surge absorbing circuit) In case of manual soldering, soldering time is max 4 sec by soldering iron (Max 350 C at the iron tip) and do not add the stress to terminals. In case of touching the soldering iron to the root of terminals, it may cause Housing parts melt. RoHS Compliant The "RoHS Compliant" designation indicates that the listed models do not contain the six hazardous substances covered by the RoHS Directive. Reference: The following standards are used to determine compliance for the six substances. Lead : 1,000 ppm max. Mercury : 1,000 ppm max. Cadmium : 100 ppm max. Hexavalent chromium : 1,000 ppm max. PBB : 1,000 ppm max. PBDE : 1,000 ppm max. 6

MEMO 7

Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product. Consult your OMR representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or equipment, and be sure to provide the system or equipment with double safety mechanisms. Note: Do not use this document to operate the Unit. OMR Corporation Electronic and Mechanical Components Company Contact: www.omron.com/ecb CSM_2_1_1216 Cat. No. A223-E1-02 1014(0313)(O)