POL909.00/xxx. Communication module to enable Web functionality for a POL6xx.xx controller. Climatix TM Climatix communication Advanced Web module

Similar documents
Digital input modules

PCS0100en Persy Control Services B.V. Netherlands

TX OPEN RS232/485 module

HWg-STE HWg-STE PoE MANUAL

IntesisBox Modbus Server Fidelio IP

HCR3.2/.. Chipcard reader HOTEL SOLUTION

IntesisBox Modbus Server SAMSUNG Air Conditioners

User Manual. EtherUSB

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

Starting Guide - Poseidon 3265 First steps for remote monitoring with Poseidon & GSM

BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP

IntesisBox KNX Mitsubishi Heavy Industries AC

Communication Unit 560CMU05 Data sheet

IntesisBox KNX Modbus TCP master

Tracer Summit Web Server

AXIS 262+ Network Video Recorder

HARTING mcon 1000 Introduction and features

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Manual. IP Sensor and Watchdog IPSW2210. I P S W M a n u a l P a g e 1. Relay Output. Power input. 12VDC adapter LED Indicators. 2 Dry.

S-series SQ Controller

Waveguide Access Point WGA631. Product Guide

10/100/1000 Base-T to Gigabit Fiber Media Converter

User Manual. EtherUSB

Router Setup Manual. NETGEAR, Inc Great America Parkway Santa Clara, CA USA

Wireless Router Setup Manual

SHEET. CTRLink. EIPR Skorpion Wired and Wireless IP Routers. EIPR Series

Ha-VIS FTS 3000 Introduction and features

BACnet. bcx1 Controller/ Router Series

MAINTENANCE WITHOUT TRAVELLING

Cisco 7816-I5 Media Convergence Server

IntesisBox KNX Modbus RTU master

Modbus Server SAMSUNG Air Conditioners

NAFEM Gateway User s Manual For Watlow part numbers NGW , NGW , NGWC , NGWC

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

MVME162P2. VME Embedded Controller with Two IP Slots

KNX IP Gateway. Light-Control R. User manual-ver.1 LC-IPGW-001. KNX Gateway. KNX/EIB Intelligent Installation Systems

DCS Data and communication server

IPG/7700 Hardware Manual SYSTECH. Document number Revision A

M-series MD Plus Controller

Product Manual. ABB i-bus KNX IP Interface IPS/S 2.1. Intelligent Installation Systems ABB

How To Write A Librao Low Voltage Differential (Lvds) Module On An Nio 6585 Fuserio (Flexrio) Power Supply (Femaleseo) And Power Supply On An Iphone Or Ip

OZS Web server. For LPB/BSB plants

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

SNMP Web Management. User s Manual For SNMP Web Card/Box

Table of Contents. Hardware Installation...7 Push Button Security Using the Setup Wizard Configuration...11 Main Security...

PXM20-E. Operator unit DESIGO PX

DU-H3ETX. 3-port USB Hub with 1 NWAY Ethernet / Fast Ethernet Port. User s Guide

HMIGTO4310 advanced touchscreen panel 640 x 480 pixels VGA- 7.5" - TFT - 96 MB

NI NI C Series Overview DATASHEET. 8-Channel Sinking Digital Input Module

DCS data and communication server

Table of Contents. Chapter1. Introduction Before Installation System Requirements... 1

applicomio Profibus-DP

QuickSpecs. HP Compaq t5525 Thin Client. Overview

KNX Panasonic Air Conditioners

M3 ORANGE single-slot Cradle. User Guide. Product Number: A-1CR-US0D-030-R00, A-1CR-U0ED-030-R00. Compatible Device(s): M3 ORANGE

OZW30. Central Unit SYNERGYR

Link Gate SIP. (Firmware version 1.20)

IVS-200 Enter: intelligent "Enter" video analytics server. Model: IVS-200 Enter

Overview of the Cisco 2500 Series Access Server

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

Ultra Thin Client TC-401 TC-402. Users s Guide

Remote Monitoring Unit SC8100. Monitoring Unit SC8100

CM500 High Speed Cable Modem User Manual

Communication standards and Carel solutions

Hardware Manual RM CANview Ethernet

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

Substation Automation Products Relion 670/650 series IEC and ANSI Hardware

SMS GSM Alarm Messenger

Temperature & Humidity SMS Alert Controller

HARTING econ 3000 Introduction and features

Power-monitoring unit PowerLogic System. Technical data sheet. Power Meter Series 800

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Phaser 5550N Adds 10/100/1000 Ethernet

Installation and setup guide V 1.0

is then retained absolutely without interruption.

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

PoE+ Extender Switch User's Manual. Rev W

smart-house Controller Central Unit Module Type SH2WEB24

WinCON8000-R2/R8. Hardware User s Manual

INDUSTRIAL GATEWAYS VPN ROUTERS SERIAL DEVICE SERVERS

GUIDE. CTRLink. EIPR Skorpion Wired and Wireless IP Routers. EIPR Series

IntesisBox KNX - LON

SBC6245 Single Board Computer

Job Aid Pre-Installation Information S8500 Media Server

R60 USB to CAN interface Manual (1.5 EN)

Cisco Unified IP Phone Power Injector

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

IRIS Touch 600 Range Dialler Installation Manual. Version 1.3

IFS SP-PoE Splitter User Manual

OZW V4.0. Web server. For Synco TM, Synco TM living

Internet-bridge XPort

M-series Virtual I/O Module 2

Figure 1: RotemNet Main Screen

II Intelligent PC/CAN Interface. Manual

Foxboro Evo Process Automation System

Automation stations modular series

UPS Network Interface. Quick InstallationGuide

Transcription:

s 3 935 Climatix TM Climatix communication Advanced Web module POL909.00/xxx Communication module to enable Web functionality for a POL6xx.xx controller The POL909.00/xxx communication module offers the following features: Internet-based device powered by Intel StrongARM SA-1110 processor Embedded WindowsCE platform with Web server application Generic tree view to read and write data points Platform to program Web applications Network parameters configurable via controller, HMI, SCOPE or Web The module must be connected to the left side of a POL6xx.xx controller Alarm server for SMS / mail Peer-to-peer communication RAS server Full modem RS-232 port GSM / GPRS support Dial in and dial out The POL909.00/xxx communication module is part of the Climatix product range (also refer to Data Sheet 3900 and Mounting Instructions M3910). CB1Q3935en_01 30.06.2009 Building Technologies

Advanced Web module Functions Software Web server Generic tree view The advanced Web module extends the communication capabilities of the Climatix controllers. It communicates using different protocols that can be loaded to the embedded WindowsCE platform. With the preloaded WindowsCE operating system, all network address parameters can be set statically, handled by a DHCP server or, if nothing is present, negotiated by the AutoIP functionality of the operating system. To manage the device, a set of Web-based extensions for the Web server are loaded to download files to access the registry or handle processes. Unlike other solutions, the AWM can be handled in managed and unmanaged networks. The advanced communication module (AWM) is an Internet-based device powered by Intel s StrongARM SA-1110 processor. Equipped with 16 MB of flash memory, 64 MB of SDRAM and preloaded with WindowsCE operating system, the AWM is a powerful starting point for an Internet or communication application. To allow access to local area networks, the onboard Ethernet controller provides the flexibility to integrate this device into networks. The Web server with its BGI capabilities and the remote management extensions (RMS) enable the user to implement and load his own Web pages and extend them with programmed Web functions. Using the RMS, all pages can be loaded to the file system. No more recompilations or firmware setup is needed. The access to certain pages can be granted based on user or group policies. The preloaded generic tree view application always reflects the loaded control program. After a modification of the controller application, only one restart is necessary to enable the operation of data points inside a Web browser. With the Java technologies used, this operation always shows the actual process data of the Climatix controller. Installation concept 2 / 6

Technical data General data Dimensions W x H x D: 45 x 110 x 75 mm Weight excl. packaging 101 g Base Plastic, pigeon-blue RAL 5014 Housing Plastic, light-grey RAL 7035 Power supply Via system interface from controller DC 5 V (+5% / 5%), max. 270 ma Microprocessor Intel StrongARM SA-1110, 192 MHz Memory 16 MB FLASH (3.3 V) 64 MB SDRAM (96 MHz) Data connectivity - 10BaseT Ethernet, with link detection - Modem Connectors: RJ45-10BaseT Ethernet with link detection RJ45-RS-232 serial with full modem support Flash programming JTAG support through CPU, download via Ethernet Software Operating system Windows CE 5.0 Storage Intel Persistent Storage Manager (IPSM) Web server With BGI extension and access security RMS Remote management for file handling, process management and registry Generic treeview Out of the box operation of loaded HVAC applications IP Ethernet 10/100 Mbit (IEEE 802.3U) Cable connection RJ45 jack, 8 pins Modem port Cable connection RS-232 RJ45 jack, 8 pins Support of GSM, GPRS Modems COMM interface plug Board-to-board ZEC1,0/10-LPV-3,5 GY35AUC2CI1 Board-to-board connector 3 / 6

Environmental conditions Operation IEC 721-3-3 Temperature -40...70 C Humidity <90% r.h. Atmospheric pressure Min. 700 hpa, corresponding to max. 3,000 m above sea level Transport IEC 721-3-2 Temperature -40...70 C Humidity <95% r.h. Atmospheric pressure Min. 260 hpa, corresponding to max. 10,000 m above sea level Protection Degree of protection IP20 (EN 60529) Standards Product safety Automatic electrical controls EN 60730-1 Electromagnetic compatibility Immunity EN 60730-1 +A16 Emissions EN 60730-1 +A16 CE conformity EMC directive 2004/108/EC Low-voltage directive 2006/95/EC Listings UL916, UL873 CSA C22.2M205 RoHS directive 2002/95/EC (Europe) ACPEIP (China) Ordering data Climatix advanced Web module POL909.00/STD Advanced Web module LEDs for diagnostics LEDs for BSP and BUS diagnostics (green, red and yellow) Mode IP running and communication ok IP not running Hardware error BUS LED status Green on Yellow on Red on Mode BSP running and communication with controller BSP running but no communication with controller BSP error (software error) BSP LED status Green on Yellow on Red blinking at 2 Hz 4 / 6

Engineering notes The communication module is attached to the controller with a board-to-board connector The connection to Ethernet is made via the T-IP port (RJ45 jack) Disposal notes The module contains electrical and electronic components and must not be disposed of together with household waste. Local and currently valid legislation must be observed! Layout of POL909.00/xxx communication module Right side Left side 5 / 6

6 / 6 2009 Siemens Switzerland Ltd. Subject to change