MOD-MBUS Modbus to M-Bus Converter Module

Similar documents
IntesisBox KNX Modbus RTU master

IntesisBox KNX Modbus TCP master

ENET-710. ENET Ethernet Module ENET-710 JAN / 06 FOUNDATION

ModBus Server - KNX. Gateway for integration of KNX equipment into Modbus (RTU and TCP) control systems.

IntesisBox Modbus Server SAMSUNG Air Conditioners

IntesisBox Modbus Server Fidelio IP

Application/Connection Examples

PCS0100en Persy Control Services B.V. Netherlands

Technical Note A007 Modbus Gateway Vantage Pro2 25/09/2009 Rev. A 1 de 7

IntesisBox ASCII Server - LON

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

TX2123 RS485 TO ETHERNET ADAPTOR

Modbus Server SAMSUNG Air Conditioners

BIT COMMANDER. Serial RS232 / RS485 to Ethernet Converter

QSE-CI-NWK-E Control Interface

Telephone- and leased line modem for industrial applications TD-36

Documentation. M-Bus 130-mbx

EZ-View Network Communications Guide

MDM192 MULTI-DROPS DIGITAL MODEM FOR PRIVATE LINE. USER GUIDE Document reference :

RcWare SoftPLC Modbus server mapping editor User manual

Temperature & Humidity SMS Alert Controller

IntesisBox KNX - LON

Process Control and Automation using Modbus Protocol

TP32MTT.03 TP32MTT [ GB ] Probes for soil thermal profile measurement

User Manual. Protocol Converter PC-E, Serial to Ethernet (RS232/485 Modbus RTU to Modbus TCP/IP)

Modbus and ION Technology

Electronic Control Devices The European Product Catalogue 2007

NetBiter webscada Modbus User Manual

7.7 Ethernet Communication (AFPX-COM5)

ZC-24DO CANopen I/O Module: 24 Digital Outputs

TX OPEN RS232/485 module

FOSTCDR. Industrial Serial to Multimode Fiber Optic Converter PRODUCT INFORMATION B&B ELECTRONICS. Specifications Serial Technology

Softstarters. Type PSTX Fieldbus communication, Built-in Modbus RTU. 1SFC132089M0201 April SFC132089M0201 1

User Manual Revision English

M-series Virtual I/O Module 2

TRP-C31M MODBUS TCP to RTU/ASCII Gateway

IntesisBox KNX LG Air Conditioning

M-Bus. Technical Description

Using the AnyBus -X Gateway to Communicate between a DVT camera and a Profibus Master

LBNP RS-232/485/422 serial device server. User manual

KNX Panasonic Air Conditioners

User Manual Revision English Converter / Adapter Ethernet to RS232 / RS485 (Order Code: HD HD M HD HD M)

L5354 ControlNet Communications Interface

Vroom Hardware manual ver Code 114VROOHWE00. Vroom CANBUS USER INTERFACE WITH LCD GRAPHIC DISPLAY AND WITH TEMPERATURE AND HUMIDITY SENSOR

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

IntesisBox KNX Mitsubishi Heavy Industries AC

Data sheet SLIO CPU 015 (015-CEFPR00)

NC-12 Modbus Application

16-Port RS232 to USB2.0 High Speed Multi Serial Adapter (w/ Metal Case) Installation Guide

Vision OPLC. V R34/V350-J-R34 Technical Specifications. Technical Specifications

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

TCP/IP MODULE CA-ETHR-A INSTALLATION MANUAL

Modbus Communications for PanelView Terminals

Quick Connect. quick - simple - efficient.

Energy Depot GmbH PRODUCT AND APPLICATION GUIDE. Total Monitoring Solution for PV. Delivering Solutions for Energy Management

Master-Touch and ValuMass. Modbus Communications. INSTRUCTION MANUAL (Rev. 2.1)

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Meter Communication. Twisted Pair Baseband (M-Bus) Physical and Link Layer CEN TC 294. Date: TC 294 WI 006 CEN TC 294. Secretariat: AFNOR

SMS GSM Alarm Messenger

RS-485 Protocol Manual

Modbus and ION Technology

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

IntesisBox Modbus Server - Mitsubishi Electric G50

Temp. & humidity Transmitter Instructions

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

How To Run An Nport I5000A Device Server

WEA-Base. User manual for load cell transmitters. UK WEA-Base User manual for load cell transmitters Version 3.2 UK

Rack mounted telephone- and leased line modem for industrial applications

SHARKY 775 COMPACT ENERGY METER ULTRASONIC

APNT#1168 Modbus - Establishing Communications Hints

Repeaters and Mimics Data Sheet

Short Form Catalogue. Alarm Systems. Reliable Supervision and Control

M2M/IoT Solutions.

Electronic Control Devices The European Product Catalogue 2007

PolyGard Carbon Monoxide CO Transmitter ADTX3 1110

User Manual. EtherUSB

Using Xbee in Serial Communication

User Manual Revision English

MODBUS TCP to RTU/ASCII Gateway. User s Manual

WEB log. Device connection plans

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

User Manual Revision English

Process Alarm Solutions

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

Zlinx Wireless I/O. Peer-to-Peer and Modbus I/O B&B ELECTRONICS PRODUCT INFORMATION

OPT SERIAL TO FIBER OPTIC CONVERTER

ISHIDA BC Scale to Scale Communications

On the M-BUS Interface you can add up to 60 M-BUS Devices (60 unit loads).

deltadue series gateways: PROFIBUS DP, DeviceNet, CANopen, Modbus TCP to Modbus RTU

Why you need to monitor serial communication?

The Answer to the 14 Most Frequently Asked Modbus Questions

Belimo Gateway MP to Modbus RTU - UK24MOD

INTMOD485-LH Protocol Converter

2-Port RS232/422/485 Combo Serial to USB2.0 Adapter (w/ Metal Case and Screw Lock Mechanism) Installation Guide

Communicate and view data from meters with one simple device

PLC Support Software at Jefferson Lab

Quick Installation. A Series of Intelligent Bar Code Reader with NeuroFuzzy Decoding. Quick Installation

Versions. Q.station Q.station T. Q.station D. Q.station DT x x

Page 1 / 14 Groupe MOBILITECHMIOSBOX Technical Specification MWP-DT1010. Technical specifications

Transcription:

Product sheet SW4.05 Type MOD-MBUS MOD-MBUS Modbus to M-Bus Module MOD-MBUS modules offer an easy-to-use and cost effective solution to collect data from MBUS devices (water meter, heat meter, current meter, gas meter). Due to the open MODBUS RTU standard the M-bus meters can easily be integrated to Modbus compatible systems such as most building management systems. The meters from which data is read are configured via PC configuration software. The modules can be configured for communication with RS232 or RS485. The MOD-MBUS module periodically sends queries to the MBUS devices connected and stores the data internally in MODBUS holding register. The Modbus master (e.g. BMS, PLC, Sedona Controllers) can then read the stored values via MODBUS RTU master protocol. Features Support for up to 2, 8, 2,and 48 M-bus Easy configuration using template based PC configuration software; large library of meter templates provided RS232/RS485 mode selectable via bit switch Modbus Baud Rates: 9k6, 19k2, 38k4, 57k6 M-Bus and Modbus interface is galvanically isolated EN50022 DIN-rail mounting Model Type Model Description MOD-MBUS-2 MOD-MBUS-8 MOD-MBUS-24 MOD-MBUS-48 MBUS-CF Modbus to M-Bus, Up to 2 M-Bus, RS485/RS232 Modbus Slave Modbus to M-Bus, Up to 8 M-Bus, RS232/RS232 Modbus Slave Modbus to M-Bus, Up to 24 M-Bus, RS485/RS232 Modbus Slave Modbus to M-Bus, Up to 48 M-Bus, RS232/RS232 Modbus Slave Configuration Software for the Technical Data Power Supply 24Vdc+/-10% <2.5W MOD-MBUS-48: 24Vdc+/-10%<3.5W Modbus Modbus RTU Slave 9600 to 57600 bps, 8 Data Bits, Parity None/Even/Odd, 1 Stop Bit Modbus Connection RS232 or RS485 (Selectable by bit switch) Modbus Data Types 5 Different Data Types for the Value Representation No. of M-Bus Devices MOD-MBUS-2: Up to 2 M-Bus / Devices (1.5mA load) MOD-MBUS-8: Up to 8 M-Bus / Devices (1.5mA load) MOD-MBUS-24: Up to 24 M-Bus / Devices (1.5mA load) MOD-MBUS-48: Up to 48 M-Bus / Devices (1.5mA load) M-Bus Comms EN1434-3, 300 up to 38,400 bps, 8 Data Bits, Parity Even, 1 Stop Bit M-Bus Cable Max.Cable Length: 350m Max Cable Capacitance: 180 nf Maximum Number of Modbus Parameters Wiring Terminals Max. 1.5 mm 2 MOD-MBUS-2: Up to 20 Data Points MOD-MBUS-8: Up to 200 Data Points MOD-MBUS-24: Up to 500 Data Points MOD-MBUS-48: Up to 600 Data Points PS SW4.05-1/5

DIP Switch Settings Factory Settings Modbus Address: 255 Modbus Baud Rate: 9600 Modbus Interface: RS232 M-Bus Baud rate: 2400 Mounting EN50022 DIN-rail Operating Temp 0..+60 C Operating Humidity 25..90% rh non-condensing Storage Temp -20..+85 C Enclosure IP20 - UL 94 V0 Grey RAL7035 Dimensions W17.5 x H90 x D58 mm Weight 0.06kg The below diagrams illustrate the DIP switch settings MODBUS/M-Bus conversion modules.. 4: Function Definition 3: Interface: RS232/RS485 2: Baud Rate 2 1: Baud Rate 1 BAUD RATE : BIT SWITCH 1 & 2 INTERFACE : BIT SWITCH 3 9600 19200 RS232 RS485 38400 57600 FUNCTI : BIT SWITCH 4 USE MODBUS SLAVE ADDRESS SET IN FLASH MEMORY BY S/W SET SLAVE ADDRESS TO 255 DIP SWITCH Baud Rate Bit Switches DESCRIPTI Use Bit Switches 1 and 2 to Select the Baud Rate. : 9600 Baud : 19200 Baud : 38400 Baud : 57600 Baud Interface Bit Switch IF Function Definition FD Note: The Modbus parity is set via the configuration software (None, Even or Odd) Select the serial interface mode for the Modbus RTUS = RS232 = RS485 Selects if the unit uses the Modbus address set by the configuration software or uses a fixed Modbus address (for test purposes) = Uses Modbus Address set by the Software = Modbus Slave Address Fixed to 255 Note: After changing the DIP switches the converter reboots immediately, so no power off or on is necessary. After reboot all the LEDs are on for half a second to signal the power on sequence. PS SW4.05-2/5

Wiring and LEDs The below diagrams illustrate the wiring of the Modbus to M-bus converters. TERMINALS L+ M- A B RX TX M- MB+ MB- DESCRIPTI Power Supply L+: 24Vdc M-: Ground RS485 Modbus RTU Slave Terminals A: Data+ B: Data - RS232 Modbus RTU Slave Terminals RX: Serial Receive TX: Serial Transmit M-: Ground for RS232 Interface to M-Bus devices LEDs STATE MBUS HOST DESCRIPTI State LED; flashes when the converter is OK M-bus Activity LED; flashes when M-bus telegrams are on the bus Host LED flashes when host sends/receives Modbus RTU telegrams Typical Network Diagram MOD-M-BUS converters are typically used as the communication interface to M-bus meters. M-bus is the European EN1434-3 standard for communicating intelligent meters. Remote User Interface using Web-Browser, Animated Graphics (HTML5) ETHERNET COMMS HTTP, BACnet, SOX, Modbus TCP Ethernet / Internet / Intranet http://192.1.10.10/... SDC-32G 32-Point Cloud Ready HTML5 Programmable Controller MOD/M-BUS-2/8/24/48 Modbus RTU RS485 MOD/M-BUS MOD/M-BUS-2/8/24/48 Energy Energy Water Electricity M-Bus Water Electricity M-Bus Heat Heat PS SW4.05-3/5

Functional Description and Modbus Registers MOD-MBUS converters read values of meters with a MBUS interface automatically and store the values in internal Modbus Holding registers. The converters can hold up to 20/200/500/600 MBUS values, depending on the type of the converter. A host system can read out asynchronously the stored values via MODBUS RTU master functionality. The physical connection is done via RS232 or via RS485 interface. After switching on the power supply the converter checks for a valid configuration and initializes all registers to zero. If there is no valid configuration or an error occurred, the state indicator flashes twice every second, on successful startup it flashes every second. The power on sequence is signaled with a simultaneous short flash of all the LEDs in the converter. For communication via Modbus are following Modbus features available: READ HOLDING REGISTER (function code: 3) PRESET SINGLE REGISTER (function code: 6) PRESET MULTIPLE REGISTERS (function code: 16) Register overview: value range counter information range configuration range *) command range reserved range *) counter 1... counter n reboot reserved *) reserved *) state identification number identification number MOD-MBUS2/8 MOD-MBUS24/48 value range 4x00001 4x00200 4x00001 4x01000 counter information range 4x02001 4x02024 4x02001 4x02072 configuration range 4x03001 4x03244 4x03001 4x04124 command range 4x06001 4x06003 4x06001 4x06003 reserved range 4x07001 4x07130 4x07001 4x07130 4x65200 4x65535 4x65200 4x65535 unused range reserved range *) *) This ranges are reserved for the configuration software and may not be written during operation. Note: A maximum of 100 registers per telegram is allowed for the telegrams READ HOLDING REGISTER and PRESET MULTIPLE REGISTERS. Modbus Data Formats and Value Ranges Following all data formats a value can be represented on the MODBUS side of the converter. Data Type 16-Bit Signed 32-Bit Signed 32-Bit IEEE Floating-Point Number 32-Bit IEEE Floating-Point Number Inverted Description This data format is qualified for the representation of small integer values with sign. Value range: -32768 32767 Representation: 2 s complement This data format is qualified for the representation of big integer values with sign. Value range: -2147483648 2147483647 Representation: 2 s complement Used for representation of very big integer and real numbers. Value range: 1,175495e-38 3,40282346e+38 Representation: IEEE floating-point 32 bit Note: This data type has a limited accuracy. By using, there may be minor deviation of the reading values via MODBUS/RTU and the values which will be shown at the meter. This variations are system-related. Used for representation of very big integer and real numbers. Value range: 1,175495e-38 to 3,40282346e+38 Representation: IEEE floating-point 32 bit Note: This data type has a limited accuracy. By using, there may be minor deviation of the reading values via MODBUS/RTU and the values which will be shown at the meter. This variations are system-related. PS SW4.05-4/5

M-Bus Interface Support Function Support communication according EN1434-3 primary addressing secondary addressing FCB mechanism initializing of a meter (SND_NKE) sending data to the meter (SND_UD) NO reading of class 2 data (REQ_UD2) reading of class 1 data (REQ_UD1) receive of meter data (RSP_UD) multiple telegram answer fixed data structure variable data structure integer data type real data type BCD data format variable data format, PARTLY primary VIFs (VIF = Value Information Field) plain text VIF linear VIF extension manufacturer specific VIFs, PARTLY manufacturer specific values, PARTLY baud rate 300 to 38400 Dimensions Notes: In the view of a constant development of their products, the manufacturer reserves the right for changing technical data and features without prior notice. PS SW4.05-5/5