Thermal actuators. for terminal unit valves VVP47..., VXP47... and VMP47... For water-based control of terminal units, heating and cooling zones

Similar documents
Thermostatic Actuators

EMO T. Thermal actuator for heating, ventilation and air conditioning systems

Butterfly Valves PN 6/10/16 for flanged connection

HERZ-Thermal Actuators

Digital input modules

2- and 3-port valves with flanged connections, PN 10

RRV934. Multi-controller. Synco living

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Actuator for modulating control AME 435

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

Air damper actuators

Product and functional description

Adjustable room thermostat for heating only or cooling only systems

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting

HCR3.2/.. Chipcard reader HOTEL SOLUTION

Flush-mounted room thermostats

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

STEP-PS/1AC/12DC/1.5. Extract from the online catalog. Order No.: DIN rail power supply unit 12 V DC/1.5 A, primary switched-mode, 1- phase

QFP910. Water detector. Building Technologies. CE1N2732en. Synco living

For UK only RXL39.1 and the applications package SP-03 are sold in the United Kingdom only.

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

TX OPEN RS232/485 module

OZW30. Central Unit SYNERGYR

Technical Manual Functional Description for S800-RSU-H / S800W-RSU 2CCC413022M Schaffhausen 1 / 10

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

Electric Rotary Actuator - On/Off or programmable control actuator

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Type overview. Technical data

VAD Variable Area Desuperheaters

Type: DILM115(RAC240) Article No.: Sales text Contactor,55kW/400V,AC operated. Ordering information

ACS-30-EU-EMDR-10-MOD

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Instruction Manual Differential Pressure Transmitter

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

DN [mm] [m 3 /h] Characterizing disk Dimensions / Weights see «Dimensions and weights», page 3 Motorizing

TA-FUS1ON. Fully adjustable Kvs control and balancing valves. That s just two good.

FDCI222, FDCIO222, FDCIO224 Input module Input/output modules

MINI MCR-SL-R-UI(-SP)

PCS0100en Persy Control Services B.V. Netherlands

VAD. Variable Area Desuperheaters

SINEAX U553 Transducer for AC Voltage

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Infrarot-Bewegungsmelder IP44

2012 Valve & Valve Actuator Catalog. For new construction or retrofits, simplify projects with our complete selection.

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

MCR1900 Media Converter 19-Slot Chassis

RVL470. Heating Controller. Building Technologies HVAC Products. Series B

PRODUCT PROFILE FEATURES

Type: EASY719 DC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 24 V DC. Description

Operating instructions Mechatronic flow sensor. SBY33x /06 03/2011

5SV Residual Current Protective Devices

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Duct Humidity Transmitter

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

225C-024T-05. Continuous control rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

Safety technique. Emergency stop module BO 5988 safemaster

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

Redundancy Module QUINT-DIODE/40

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

OZS Web server. For LPB/BSB plants

Cable Plug acc. to DIN EN , Form A

3/2-way Solenoid Valve, direct-acting, NC or NO

Heating Controller. Building Technologies HVAC Products

Type: DILM32 10(24V50HZ) Article No.:

Air damper actuators Rotary version, two-position control, with spring return, AC 24 V or AC 230 V

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Type: DILM50(230V50HZ,240V60HZ) Article No.:

CompactLogix Power Supplies Specifications

Data sheet ECC 12 and 22

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

How To Drive A Compact Serie 1

Machine Safety Switches

MasterINTERFACE 39 Series - Relay interface modules

ADM1TE 5/30A DIN rail single phase two wire energy meter

Three-phase monitoring relay CM-PFE

48 SERIES Relay interface modules 10 A

Product Manual. ABB i-bus KNX Data Logging Unit BDB/S 1.1. Intelligent Installation Systems ABB

of the LED control gear Compact dimming Uconverter LCAI 55W 900mA 1750mA ECO SR ECO series

Digital inductive conductivity transmitter

Power Supplies 3. SDN-P DIN Rail Series

How To Use A Flowmeter

Actuator-Sensor-Interface

Linear Luminaire with LED Series EXLUX 6402/2

HMI display Installation Guide

DRM75A 230V 20/100A DIN rail single phase two wire energy meter

Overview of types. Technical data

LC1D65AM7 TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 65 A V AC coil

Transcription:

4 878 Thermal actuators for terminal unit valves VVP47, VXP47 and VMP47 STP21 STP71 STP21 AC 230 V operating voltage, 2-position control signal STP71 AC/DC 24 V operating voltage, 2-position control signal or PDM (pulse-duration modulation) Positioning force 105 N For direct mounting with union nut (no tools required) Standard versions with 12 m or 5 m connecting cables Two-wire connection Position indication Robust construction, quiet operation, no maintenance required Valves can be opened without positioning signal (for filling the system) Optional tamper-proof fitting to prevent dismantling (for radiator valves only) Use For water-based control of terminal units, heating and cooling zones Standard applications (valve closed when actuator de-energized): For Siemens small valves types VVP47, VXP47 and VMP47 For retrofitting Siemens small valves 2W, 3W und 4W Special applications (valve open when actuator de-energized): For Siemens radiator valves, MiniCombiValves, small valves and valves from other manufacturers CE1N4878en 21122005 Building Technologies HVAC Products

Type summary Type Operating voltage Positioning time at 20 C STP21 STP21/50 STP71 STP71/50 AC 230 V AC / DC 24 V 3 min Positioning signal 2-position PDM 1) Connecting cable 12 m 50 m 12 m 50 m 1) pulse-duration modulation Accessories Adapter type For valve makes Adapter type For valve makes AL100 Siemens 2W, 3W, 4W AV56 Giacomini AV51 Beulco old (M30 x 10) AV57 Herz AV52 Comap AV58 Oventrop old (M30 x 10) AV53 Danfoss RA-N (RA2000) AV59 Vaillant AV54 Danfoss RAVL AV60 TA 1) AV55 Danfoss RAV AV61 Markaryd 1) No adapter required for type TBV-C Type AL41 Description Tamper-proof fitting to prevent dismantling of actuators (for radiator valves only) Ordering Example: When ordering please specify the quantity, product name and type code 1 actuator, type STP21 with 12 m cable and 1 adapter, type AV53 Delivery The valves, actuators and accessories are supplied in separate packages Equipment combinations Valve type Description k vs [m 3 /h] V & [l/h] PN class Data sheet VVP47 VXP47 2-port valves 3-port valves 02540 VMP47 3-port valves with T-bypass 02525 2W 1) 2-port valves 0625 3W 1) 3-port valves 0640 4W 1) 3-port valves with T-bypass 0625 V I46, V S46 Zone valves 2 5 PN 16 N4847 N4846 N4842 VDN, VEN, VUN Radiator valves 2) 009 141 N2105, N2106 VPD, VPE MCV radiator valves 2) 25 483 PN 10 N2185 VD1 CLC Small valves 025 26 Radiator valves (M30 x 15) from other manufacturers, without adapter: Heimeier MNG Cazzaniga TA-type TBV-C Oventrop M30 x 15 (from 2001) Junkers Honeywell-Braukmann Beulco new For other radiator valves 2) with type AV adapters, see «Type summary / Accessories» k vs = Nominal flow rate of cold water (5 to 30 C) through the fully opened valve (H 100 ) at a differential pressure of 100kPa (1bar) V & = Volumetric flow at a stroke of 05 mm 1) 2) Replacement for thermal actuators STE22 and STE72 (AL100 adapter required) See «Application note» below N2103 2/8 HVAC Products 21122005

Application note 1) Radiator valves VDN, VEN, VUN VPD, VPE STA Actuator de-energized STP closed open 1) Small valves V P47 A AB open A AB closed VD1 CLC closed open Zone valves V I46, V S46 AB A closed AB A open Not applicable with DESIGO RX Technical and mechanical design The following description of functions applies to standard applications (valve closed when actuator de-energized) with terminal unit valve types VVP47, VXP47 and VMP47, and types 2W, 3W and 4W Function Position indication When the control signal is applied to the actuator, the temperature of the heating element rises, causing the solid expansion medium to expand This expansion is converted into a linear movement The actuator stem is extended and the valve opens When the actuator is de-energized, the actuator stem retracts and the valve is closed by the force of the spring The STP21 and STP71 thermal actuators have no rotating parts Consequently, they operate quietly and are not subject to wear The valve position is indicated by a green bar which moves up and down the actuator stem In this position, the actuator is de-energized: the actuator stem is retracted and the valve is closed 4877Z06 In this position the valve has been connected to the power supply for at least three minutes: The actuator stem is extended and the valve is open Positioning times opening / closing Positioning signal [%] 100 4877Z07 1 2 3 0 1 2 3 4 5 6 7 8 9 Time [min] Stroke [mm] at 20 C ambient temperature 25 1 1 2 3 0 1 2 3 4 5 6 7 8 9 Time [min] The positioning time depends on the voltage and the ambient temperature HVAC Products 21122005 3/8

Opening without a positioning signal With an STP actuator fitted, the valve can be opened to approximately 50% of its stroke without a positioning signal This enables the hydraulic system to be filled with the medium For this purpose, the U-pin supplied must be inserted between the actuator housing and the stem as shown in the diagram below 4878Z02 4878Z01 4878Z03 Note Ensure that the U-pin is removed once the system has been filled Accessories AL100 adapter When retrofitting valve types 2W, 3W and 4W with the STP actuator, an AL100 adapter is required 01723 2 01768 2 mm 1 A AB A AB A AB B B 4878Z04 B Adapter type AV for third-party valves Note Adapter types AV51 to AV61 are available for mounting the STP actuators on thirdparty radiator valves as shown under «Type summary / Accessories» In these applications, the valves are open when the actuators are de-energized Tamper-proof fitting AL41 (for radiator valves only) 4877Z04 01422 1x 1x 4877Z02 4877Z03 Tighten gently b a 4877Z05 4/8 HVAC Products 21122005

Mounting and installation notes Warning Mounting instructions are printed on the plastic packaging The STP actuator and valve are delivered as separate units They are easy to assemble on site shortly before commissioning: Remove the protective cover from the valve body Put the actuator in position and tighten the union nut manually Do not use pipe wrenches, spanners or similar! The plastic packaging can be used as a temporary cover for protection from dust etc Orientation 45 IP43 45 Warning The actuators must be installed only in a position from upright to horizontal Under no circumstances must the actuator be suspended below the horizontal IP41 45 45 IP41 4878Z05 Notes on electrical installation Installation must be carried out in compliance with local installation regulations The cable must be connected downwards so that it leads away from the bottom A means of isolation from the power supply must be provided, for example by connecting an automatic circuit breaker or switch fuse upstream of the control unit Maintenance The actuator is maintenance-free Repair Disposal The connecting cable must not be replaced by any other cable Opening the actuator can cause it irreparable damage The actuator cannot be repaired, it must be replaced as a complete unit The device must not be disposed of as domestic waste Legislation may demand special handling of certain components, or it may be sensible from an ecological point of view Current local legislation must be observed Warranty The technical data given for these applications is valid only for valves used in conjunction with the Siemens and third-party actuators listed under «Equipment combinations» If the STP actuators are used with other valves, then the user is responsible for ensuring correct functioning and all claims under Siemens Switzerland Ltd / HVAC Products warranty are invalidated HVAC Products 21122005 5/8

Technical data STP21, STP21/50 STP71, STP71/50 Power supply Operating voltage Extra low voltage 1) AC 230 V, 5060 Hz AC 24 V, 5060 Hz or DC 24 V Voltage tolerance ±15 % ±20 % Power consumption Operation 25 W 25 W On power-up 58 VA 6 VA Switch-on current (transient) 250 ma Primary fuse External Control Positioning signal 2-position (operating voltage on / off) PDM (pulse duration modulation) Operating data Positioning time at 20 C 3 min Nominal stroke 25 mm Positioning force 105 N -4/+20 % Manual adjuster U-pin for use when filling the system Actuator de-energized Actuator stem retracted Valve types VP47, 2W, 3W, 4W A AB open Radiator valves VDN, VEN, VUN Open MCV MiniCombiValves VPD, VPE Open Small valves VD1 CLC Open Zone valves V I46, V S46 AB A closed Maintenance No maintenance required Materials Cover and base Polycarbonate Electrical connection Connecting cable (integral) Stranded conductor / 2 x 075 mm 2 Cable length STP 12 m STP/50 50 m Dimensions / Weight Dimensions See «Dimensions» Weight 015 kg (12 m) 029 kg (5 m) Mounting Fixing on valve Union nut, M30 x 15 Orientation Upright to horizontal; do not suspend Safety Product safety EN 60730:27 EN 60730:27 Overvoltage category II III Contamination level 2 2 Electrical safety SELV-E (PELV to IEC364-4-41) Protection standard Mounted upright ±45 IP 43 to EN 60529 Mounted between upright and horizontal IP 41 to EN 60529 Conformity Meets the requirements for CE marking Use Suitable for indoor use General environmental conditions 1) Only admissible with extra low voltage (SELV or PELV) Operation EN 60721-3-3 Transport EN 60721-3-2 Storage EN 60721-3-1 Temperature +5+50 C 20+60 C +5+50 C Humidity 5 85 % rh 5 95 % rh 5 95 % rh 6/8 HVAC Products 21122005

Connection diagrams STP21, STP21/50 L AC 230 V (L) (Y) N1 L N Y1 4877A01 N Y Positioning signal N1 Controller Y1 Actuator L System potential AC 230 V N System neutral STP71, STP71/50 SP AC / DC 24 V (G) (G0) (G0) (Y) N2 G0 G Y2 SN Y Positioning signal N2 Controller Y2 Actuator SP, G System potential AC / DC 24 V SN, G0 System neutal 4877A02 Connecting cable STP21, STP21/50 4877Z08en brown L blue AC 230 V N STP71, STP71/50 4877Z09en brown blue G G0 AC/DC 24 V Dimensions Dimensions in mm 435 4877M01 4877M02 47 62 46 M30 x 15 HVAC Products 21122005 7/8

8/8 2005 Siemens Switzerland Ltd Subject to change HVAC Products 21122005