Trouble shooting Heat Surge Fireplace Inserts

Similar documents
Heat Surge Model X5C Fire Place Insert Service Manual Applies to all units w/ circuit board

EVANS ELECTRONIC TEMPERATURE CONTROL TROUBLESHOOTING GUIDE for systems equipped with electric coolant valve and external PC board.

Cambridge Electric Infared Fireplace User Manual

NewAir AC-10000E, AC-10000H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Hydraulic Trouble Shooting

Service manual. Website: CAUTION - BEFORE SERVICING THE UNIT, READ THE SAFETY - PRECAUTIONS IN THIS MANUAL.

ECM. Service Guide.

IMPORTANT SAFETY INSTRUCTIONS WARNING READ AND SAVE THESE OPERATING AND SAFETY INSTRUCTIONS BEFORE USING THIS HEATER.

IMPORTANT INSTRUCTIONS & OPERATING MANUAL. Houston 50 Inch Electric Wall Mounted Fireplace Black / White

CDS TROUBLESHOOTING SECTION I. VACUUM Weak vacuum at wand. Gauge reads normal (10hg to 14hg)

CARING FOR YOUR WATER HEATER

FOR THE FOLLOWING MODELS: EE-8075W EE-8075O EE-8075R EE-8075BK

A.Y. McDonald Mfg. Co. Troubleshooting Submersible and Jet Pumps

Heater and Air Conditioner, Blend Air System, Troubleshooting 83.06

Service Guide 12/27/03 TESTING, SERVICE & REPAIR GUIDE (For SH Space Heating Models & RA Water Heating Models)

Arc Fault Circuit Interrupters Frequently Asked Questions

NewAir AC-10100E / AC-10100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

Battery Charger For Nickel Cadmium and Nickel-Metal Hydride Rechargeable Batteries Model PSN Series

Portable Evaporative Air Cooler. OWNER S MANUAL Read and save these instructions before use. Model: CL30XC

Split Air Conditioner

PC1131 Electric Air Compressor

PC1130 Electric Air Compressor

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Tankless Electric (RTE) Troubleshooting

MAINTENANCE & TROUBLESHOOTING

Oil and Coolant Circulating Heating System. Model - OCSM

Electronic Brake Controller Hayes Brake Controller Company ENERGIZE III P/N # 81741B or ENERGIZE XPC P/N #81745 OPERATION MANUAL

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

ESPD8-301R MODEL ESP-D FAN COIL UNIT TROUBLESHOOTING GUIDE

Chapter 7 Hydraulic System Troubleshooting

Digi-Motor Installation Guide

SERVICE MANUAL FOR 12 VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOF TOP UNITS ONLY

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

Service Manual 33 Wide Screen Fireplace with Full Feature Remote Control

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

High kw Electric Tankless Water Heater Troubleshooting Guide

SPA BUILDERS LX-10 STANDARD TROUBLESHOOTING APPROACH

Trouble Shooting. Pump

Service Manual. Model Number VCX1525 VCX1525-WH. UL Part Number

Odyssey of the Mind Technology Fair. Simple Electronics

Wilo SP Series Submersible Sump Pumps ECS. ECS ECS ECS Installation and operating instructions

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

Service Manual. 30 Insert. Model Number: EF3003/SF3003/DF3003. UL Part Number (Canadian and Chinese Built) DFB6016 (DFB6016)

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:

Safety, Operation and Maintenance Manual with Parts List

PRODUCT: WASHER / WASHER-DRYER COMBO MODEL: AW 120 / AW 122 / AW 125 AWD 120 / AWD 121 / AWD 129


Rinnai Tankless. Water Heater. Troubleshooting Manual

INFRARED QUARTZ WALL HEATER

STAINLESS STEEL TANK TABLE OF CONTENTS TROUBLESHOOTING... 1 TESTING WATER TEMPERATURE... 3 TANK & JACKET ASSEMBLY... 4.

Section 7. Evaporator thermistor. Under-and-over pressure safety switches. Connections to the ECU

Table Z. Troubleshooting Chart for Air Conditioners. Cause

SERVICE MANUAL 12VDC WALL THERMOSTAT AIR CONDITIONING SYSTEMS ROOFTOP UNITS ONLY

Gas Oven Repair Guide

NewAir AC-14100E / AC-14100H Portable Air Conditioner Owner s Manual PLEASE READ AND SAVE THESE INSTRUCTIONS

SERVICE MANUAL RESIDENTIAL ELECTRIC AND LIGHT DUTY COMMERCIAL ELECTRIC WATER HEATERS. Troubleshooting Guide and Instructions for Service

Chromalox. Installation, Operation. Portable Industrial Unit Blower Air Heater Type DRA RENEWAL PARTS IDENTIFICATION

HEAT SIPHON ANSWERBOOK

For Models #6-5001, #6-7501, # & #10-12K1

Instruction manual for Firstline FCS12000CH

Operating Precautions: User configuration options:

Table V. Troubleshooting Checklist for Refrigeration Systems. Air or non-condensable gas in system. Inlet water warm.

TROUBLESHOOTING GUIDE

AROS SMART WINDOW AIR CONDITIONER

TB-A A. O. SMITH - FVIR INTELLI-VENT TROUBLESHOOTING CHART # LED STATUS PROBLEM SOLUTION

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

CHAPTER 4 UTILITY SYSTEMS ELECTRICAL. Utility Systems Electrical. Main Panel

FOXAIR 60/50 ALL MODELS

ENGLISH INSTRUCTION & INSTALLATION MANUAL DUCTLESS MINI SPLIT AIR CONDITIONING SYSTEMS

Back-UPS 650 VA 120 V with AVR (BX650CI-LM)

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Class 5 to 7 Truck and Bus Hydraulic Brake System

SIMPLE ELECTRONIC IGNITION WIRE DIAGRAM THERMOSTAT (3) PV PILOT BURNER/IGNITOR - SENSOR Q345A (9) SPARK (4) GND (BURNER) CHASSIS GND

ELECTRICAL SAFETY. The standard unit for measuring electrical current.

Use and Care Manual. Model CPA12KH AIR CONDITIONER

Thermo Top - Troubleshooting Tree

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CHCSCS

Electric Kettle. Model: SK-1717 INSTRUCTIONS MANUAL

Installation and Operation Manual Back-UPS BX800CI-AS/BX1100CI-AS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

User s Manual AURORA 1.2K/2.2K

D I G I T A L C L A M

Compressor Service & Maintenance Manual

Tankless. Water Heater. Troubleshooting Manual

MIGRATION HEIGHT-ADJUSTABLE DESKS. Troubleshooting Guide

Operation Manual. 150 Watt Halogen Light Source for Endoscopy Model # s ESS-150, ESS-150A ESS-220, ESS-220A

User Manual. English. APC Smart-UPS SC. 1000/1500 VA 110/120/230 Vac. 2U Tower/Rack-Mount Uninterruptible Power Supply

MAINTENANCE & TROUBLESHOOTING

SPLIT WALL MOUNTED TYPE AIR CONDITIONERS OWNER'S MANUAL

Fan Coil EC Motor Control

Air Conditioner P O R T A B L E. Instruction Manual. Your Guarantee. For model WA-1220M WA-1220H, WA-1220E. Portable Air Conditioner / Heater

Dehumidifier Users manual. For Models: DH45S DH65S

TOYOTA STARTING SYSTEMS. General

Single Phase Soft Starter

14. Troubleshooting Guide

UB1 AIR CONDITIONING UNIT INSTALLATION INSTRUCTIONS

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Appliance Diagnostic Modes Microwave. GE Consumer & Industrial Technical Training

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

Installation and Troubleshooting Instructions for Electric Tankless Residential Water Heaters.

Norcold Repair Guide Models 442, 443, 452, 453, 462, 463, 482, 483

Transcription:

Symptom Possible Cause Test Fix or Replace Bad outlet or circuit verify outlet/circuit has power, test by plugging in another electrical device. Bad cord verify cord and plug are not damaged. Check for 110-120vac at cord connections to MPCB and reset button. Bad 15amp reset button Push reset button in if out. Bypass reset and tip switch. Connect cord directly to MPCB. faulty tip switch and/or bad Bypass tip switch. Connect from reset button to MPCB. tip switch wires Bad MPCB Slow or sticking fan, dust clogged intake louvers and/or exit plenum screen and vent. Weak/worn or open fusible link on heater Bad fan relay on MPCB M-Series and Y10 only. Darkened, broken or loose connectors on heater leads, fusible link leads or neutral lead to MPCB, or broken heater coil wires. Bad 15 amp reset button and/or tip switch Darkened, loose or discolored tip switch wires Connect MPCB directly to cord. MPCB should beep once when connected to outlet and beep each time a button is pressed on the touch key pad. Air flow is low or severely blocked, slow moving or sticking fan. Heat builds up, element overheats, fusible link opens up to cut power, a small spark is seen, unit shuts off and MPCB beeps 10-15 times. Use another working outlet/circuit which has no other electrical device plugged into it. Restart Replace cord if bad. Restart If MPCB powers up, replace reset button and any discolored wires. Restart If MPCB powers up, replace tip switch and/or tip switch wires if bad or loose. Restart. If MPCB does not beep, replace MPCB and use wiring schematic or call technical support for assistance. Clean louvers and plenum of obstructions. Clean and lube fan bushings with light oil or replace fan. Unplug insert for 7-10 minutes for cool down and fusible link reset before plugging back in and restarting. Fan is spinning freely, adaquate air flow. Unit sometimes Replace fusible link by replacing heater. Restart. works on low, but overheats on high. (Turn thermostat all the way to the right) Bridge fusible link on top of heater with small wire or at MPCB. Retest. If heat stays on for a long period, fusible link is bad. Fan runs intermittently or doesn't start up immediately Replace MPCB and use wiring schematic or call technical when low or high heat is turned on. To test fan, power fan support for assistance. Uplug, allow to cool and Retest. with 110vac. If it spins like normal, fan is good, MPCB is bad. Fan comes on for 20-30 seconds when unit is plugged in. Replace heater or any heater circuit wire(s) found to be Press "POWER ON" button, immediately a beep shut down defective. Uplug, allow to cool and Retest. occurs. Units with bad heater circuits will not turn on. Examine all wiring on heater circuit. Check for continuity in heater coils (no breaks in any coil wire). Bypass reset button and/or tip switch. Connect cord directly to tip switch or MPCB. Check wire insulators for discolor, loose or corroded connections. Replace tip switch wires if found to be darkened, loose or corroded at connections. Bad cord to MPCB connections Clean and secure connections where power comes into MPCB from cord and tip switch (No separate tip switch on M7 and Y10). Check MPCB for any cracks, breaks, darkened, damaged connectors. Bad Potentiometer thermostat Pull out thermocouple, unit should have both low and high heat continuously. When MPCB powers up, test unit on high heat. If run time exceeds previous tests, replace reset. Bypass test will work for tip switch too. Retest. Replace tip switch and any wires. Restart Replace MPCB, cord, or wires Bad heater wires Check for Burnt, loose or discolored heater wires, retest Replace heater wires. Restart. Bad heater Check continuity (no breaks) on both low and high coils. Replace heater. Restart. Bad MPCB 40W lights or LED not lighting Syncro motor not turning or disconnected from flame rod/tube Syncro motor turning backward Bad MPCB will keep 40w lights on when unit is off but still plugged into outlet. Trouble shooting Heat Surge Fireplace Inserts Quick Note: There are increasingly more retrofit units out now so identifying the MPCB is important to ensure proper diagnosis and repair. Use wiring schematics from part change-out Matrix on essco.net to help identify MPCB or call technical support at 330-244-8161 for help. Also see Matrix for part numbers and model fitment. No Power (Does not Beep when plugged in. Does not respond to buttons on touch key pad or remote) Quick Note: If insert is off due to a previous Beep Shutdown, insert must be unplugged and allowed to cool down 7-10 minutes to reset fusible link before plugging it back in for retesting. Ensure all connections to outlet, cord, tip switch, reset button, and MPCB are good. Beep Shut Down (unit beeps 10-15 times, must be unplugged and cool down 7-10 minutes before retesting) Quick Note: A Beep Shut down is a safety feature which guards against overheating. Most common causes are: restricted air flow at the intake louvers or at heat output vent. A dirty, slow turning or sticking fan. A worn fusible link. On M-series and Y10 only, any bad connections on heater leads, neutral lead, fusible link leads or a break in heating coils will cause beep shutdown. Less often a broken fan relay on MPCB will prevent fan from turning on and cause beep shutdown. Non-Beep Shut Down (Unit shuts off after a time but does not beep. More often on high heat rather than low heat) Quick Note: Non-Beep Shut down cuts power before it reaches MPCB. That's why there is no beep from MPCB. 15 amp reset button or faulty tip swich is usually the problem (M7 and Y10 have tip switch built into MPCB so a bad reset can still cause non-beep shut down). Darkened or discolored connectors on any wire indicates problem with component. Replace component and any bad connecting wires. No Heat (Fan comes on but heat does not, then fan turns off) Flame Issues (No light or moving flame, jumpy or backward flame. Lights stay on when unit is off) Check for 110-120Vac at low and high teminals on MPCB, discolored, damaged or loose terminals. Check bulbs. Check 110-120vac at socket and on MPCB. Check 12vdc at 2-pin LED connector on MPCB Check 110-120vac at syncro motor and on MPCB. Check syncro to flame rod/tube coupling. Flames are going down into logs instead of up from logs. Check for 110-120vac at light connections on MPCB when unit is off. Replace potentiometer thermostat. Turn knob left and right to see if heat will shut off. Operating range is 65-100 degrees. Restart. Replace MPCB. Restart. Quick Note: Pull out thermocouple from MPCB to test heater. With thermocouple disconnected, unit should have both low and high heat without limitations. The potentiometer is usually the defective part. Rarely is the thermocouple bad but if a new thermostat doesn't work then replace thermocouple too. If power out from MPCB is okay, change light bulbs or LED. If no power out from MPCB replace MPBC. Replace syncro motor if power out of MPCB is okay. Replace MPCB if no power out on MPCB Replace syncro motor. Replace MPCB Quick Note: Grinding, banging, squeaks, and case vibration are usually caused by motors. Heater fans, syncro motors and flame tub/rod rotation are most likely to produce noise and vibration complaints. Look to snycro motor and rotating flame rod/tube to cause noise when heat is off. The cross flow fan and motor are most like to cause noise during heat cycles. Fan and blower noise seems louder on Accent models bcause plenum design is different than that of Roll-n-glow models. Trouble Shooting Chart 2013

2012/2013 Heat Surge Fireplace Helpful Tips Prior to Diagnosis 1) Have your unit (insert) in house, top off and ready to give us details (symptoms) of your trouble shooting so we can help you evaluate the problem. 2) Have the Model and Year of the insert ready to help us to determine what parts will be needed. 3) Be sure you check on a Warranty Claim Number to verify warranty before working on units. 4) Fill out Warranty Claim Forms properly to eliminate delays in processing. 5) Be aware of the Heat Surge Insert Component change out Matrix Chart. This chart details models, schematics, parts and retrofit combinations. 6) Have old board out and new board mounted and ready for re-wire (hook-up) when calling us. This will save on delays. 7) The two most common mistakes on the new board X5C hook-up are the fan and flame. Most people are reversing these two because they look at the old board and get confused and carry that over to the new board. 8) On the 2008 Model, please remove the thermocouple when replacing the main circuit board. Not needed per the Matrix Chart. 9) On the X5A/X5B series when replacing the board, you must replace with a 20 ohm thermocouple and a 50k potentiometer (RETRO). See the Matrix chart. 10) Selling parts to consumers is not recommended. Consumers may create more of a problem to themselves when installing parts improperly and not getting the right parts to really fix their problems. Most important issue with consumers making the repairs themselves is the liability. 11) Heat Surge is here to answer your questions, please try to call when it is the most convenient for you and at a time where you can dedicate the necessary time to walk us through your questions from start to finish. Please keep in mind that if you put us on hold for any reason during the diagnosis, it prolongs and delays our trouble shooting time we have other customers waiting to be helped and phone calls to be returned. Put yourself in my shoes when I can t get back to you in a timely manner. 12) When in doubt, please call Heat Surge!!! Walt 330-244-8161

Heat Surge Fireplace Insert Troubleshooting NO POWER When the fireplace insert is plugged into a 120vac, 60HZ power source, an audible BEEP shall emit from the Main Printed Circuit Board. M-Series model fans will come on for 10-12 seconds then shut off. If NO BEEP, check following: Verify OUTLET/CIRCUIT is ON and in good operating condition. Verify CORD & PLUG are not damaged or broken.. Check & Press 15AMP RESET SWITCH. Tip unit back & forth and side to side to ensure TIP SWITCH pendulum is hanging straight down and free. M7 and M8 models have tip switch integrated into MPCB. ADL 2000 MX from 07 and 08 do not have tip switches or reset buttons. NOTE: If INSERT is OFF due to a previous BEEP SHUTDOWN, INSERT must remain unplugged and allowed to COOL DOWN to reset FUSIBLE LINK for 7 to 10 MINUTES. If still NO BEEP, remove INSERT from Mantle and remove TOP ACCESS PANEL to reveal electronic components for testing. To remove INSERT on newer models from Mantle, place unit face down, remove 4 SCREWS holding insert to TOP & BOTTOM BRACKETS on the back. Lift Mantle straight up and off. INSERT will come out through the front. Older models have 4 SCREWS and 4 TABS holding unit to inside front of Mantle. Remove 4 SCREWS from wood, bend 4 TABS back away from wood front towards the side of INSERT. Lift Mantle straight up and off. INSERT will come out through the front. Check all internal connections from CORD to MAIN PRINTED CIRCUIT BOARD (MPCB). Individually or together test continuity of CORD, 15AMP RESET SWITCH and TIP SWITCH. Test power at 15AMP RESET SWITCH and TIP SWITCH. Replace if no power present. If no power present on MPCB, replace MPCB. 1 330-244-8161

Side note: Malfunctioning MOTOR will cause heat to shut OFF or complete SHUTDOWN of INSERT. NO MOVING FLAME or (LIGHTS) NOTE: FLAME (LIGHT SOURCE) and FLAME MOVEMENT (FLAME TUBE and SYNCRO MOTOR) are instantly and always operating when the INSERT is turned ON whether the heater is being used or not. When the INSERT is turned on via the TOUCH KEYPAD or HAND HELD REMOTE, an auditable BEEP shall emit from the MPCB, the flame BULBS or LEDS turn on at its last selected intensity and the SYNCRO MOTOR will come on instantly. NO FLAME is a result of: Dim lights may be due to settings from TOUCH KEYPAD or HAND HELD REMOTE. Loose or burned out bulb(s). No power to LIGHT SOCKET(S) & HARNESS. Check SOCKETS, HARNESS, HOT & NEUTRAL light spade terminals at MPCB for 120vac. No power at MPCB, replace MPCB. LED lights are 12 volt and plug into MPCB with a two prong connector. Malfunctioning LED PANEL or LED 2-pin connector at MPCB. No power/broken at LED, replace LED. No power at MPCB, replace MPCB. NO MOVING or JUMPY FLAME is a result of FLAME TUBE and SYNCRO MOTOR. FLAME TUBE bent, broken, binding, or missing from bracket and/or not connected to SYNCRO MOTOR. Replace or fix FLAME TUBE. SYNCRO MOTOR not turning due to: No power at MPCB spade terminals (replace MPCB), broken, seized or bad SYNCRO MOTOR, replace SYNCRO MOTOR. Newly delivered or stored INSERTS exposed to cold temperatures must warm to room temperature for proper operation of SYNCRO MOTOR. Moving fireplace while in operation can cause TIP SWITCH movement interrupting current flow and causing flickering of flame effect. 2 330-244-8161

HEAT ISSUES Basic operation of Low or High heat functionality shall be selected by either the TOUCH KEYPAD or HAND HELD REMOTE. No heat, low or intermittent heat, or shutdown can be a malfunction of: MAIN PRINTED CIRCUIT BOARD (MPCB). CROSS FLOW FAN & MOTOR. INFRARED (IR) HEATER ASSEMBLY/FUSIBLE LINK. THERMOSTAT POTENTIOMETER/THERMOCOUPLE. Blocked front EXIT VENT, REAR INTAKE, or CLOGGED AYR FILTER. Inadequate house outlet/circuit tripping 15AMP RESET SWITCH. When the heater low mode button is selected on the TOUCH KEYPAD, an audible BEEP will emit from the MPCB and a low heat LED indicator on the KEYPAD will go on steady. The CROSS FLOW FAN & MOTOR will turn on instantly. The low heat relay will energize after a (5) SECOND TIME DELAY turning on the single heating element. Pressed a second time the relay drops out turning off the heater and then the blower fan 20 seconds after. If both low and high heat relays are energized, pressing the low heat button will deenergize the high heat relay leaving only the low heat relay energized. When the heater high mode button is selected on the TOUCH KEYPAD, an audible BEEP will emit from the MPCB and both low and high heat LED indicators on the KEYPAD will go on steady. This button shall energize the high heat relay after a (5) SECOND TIME DELAY turning on a second heating element. Pressed a second time the relay drops out and de-energizes both low and high heat relays turning off the heater and then 20 seconds later the blower fan. NOTE: CROSS FLOW FAN & MOTOR is instantly ON and always operating when either the low or high heat setting is ON. This fan is critical to maintaining an adequate air flow to properly dissipate and distribute heat generated by IR HEATER ASSEMBLY with FUSIBLE LINK. Malfunctioning CROSS FLOW FAN & MOTOR will cause heat to shut OFF or complete SHUTDOWN of INSERT. 3 330-244-8161

NO HEAT, LIMITED HEAT OR SHUTTING DOWN If the INSERT has a THERMOSTAT POTENTIOMETER and THERMOCOUPLE: Turn THERMOSTAT all the way to the right (high setting). If still no heat, check power from MCPB for both HOT 750W spade terminals (high and low) and (1) neutral spade terminal. If no voltage when on, change MCPB. NOTE: If THERMOCOUPLE is disconnected, insert will heat continuously and will not be controlled by the POTENTIOMETER. If heat stops when the THERMOCOUPLE is plugged back in, replace POTENTIOMETER. 208 MPCB needs 20K OHM THERMOCOUPLE 30000214. If voltage is present at MCPB for both HOT 750W (high and low) and neutral spade terminals, check voltage or continuity across FUSIBLE LINK. If FUSIBLE LINK is bad, replace IR HEATER. If heat comes on for a short time and stops with THERMOSTAT turned to high (all the way to the right) replace THERMOSTAT. Discolored heater wire insulators at heater and/or MPCB indicate heat damage and wires should be replaced. If heat comes on for a while, INSERT shuts down completely and MPCB BEEPS 15 times, replace IR HEATER, or check CROSS FLOW FAN & MOTOR to ensure it is spinning freely. If not operating smoothly or producing enough air flow, replace CROSS FLOW FAN & MOTOR. Clear items such as curtains from blocking air inlet vents. Verify installed filter, if any, is clean and not blocked. 4 330-244-8161

MOTOR/MOTION NOISE Inserts have 2 motors: SYNCRO MOTOR and CROSS FLOW FAN & MOTOR. Each can produce noise and or vibration. Any motor/motion noise, vibration, or clunking when Heat is OFF, but INSERT is ON, will be coming from the SYNCRO MOTOR turning the FLAME TUBE. Inspect SYNCRO MOTOR, FLAME TUBE and connecting points and brackets. Replace SYNCRO MOTOR if motion is jerky, spins backwards, loud, not turning or vibrating. FLAME TUBE may also cause irregular movement. Inspect and replace broken or unserviceable FLAME TUBE. Any motor/motion noise, vibration, rattling, etc. when heat is ON will be coming from the CROSS FLOW FAN & MOTOR. POWER CORD IS GETTING WARM OR HOT Heaters are considered high draw appliances and some amount of cord warming is normal and acceptable. If your cord seems hot to the touch, unplug the cord and try it in another outlet. Worn outlets will cause high resistance and heat. If problem persists after repairs are made, advise the customer to contact an electrician to check customer s outlets and circuits. Make sure plug fits snuggly into outlet. HOUSE BREAKERS ARE TRIPPING Verify no other appliances are plugged into the same circuit. Do not use power strips, surge protectors, No-ground plug adaptors, or under-sized extension cords. Try a different circuit. ODOR DURING INTIAL USE In the process of manufacturing, certain non-harmful lubricants are used which burn off at the initial use of your fireplace. These fumes will not occur after continued use of your fireplace. Inserts that have been in storage or unused for long periods of time, may also have an odor upon first start up due to accumulated dust or dirt inside insert. 5 330-244-8161

TECHNICAL SUPPORT Technical support is available weekdays 7:30 to 5:00 EST by calling: 330-244-8161. If the line is busy, leave your name and number, we ll call you back. There are also technical manuals available at www.essco.net. Login using your dealer identification and pass word. Go to Resource Center, Heat Surge to get the following technical documents (and more added throughout the season). Parts L ng With Images(.pdf) Heat Surge Insert Troubleshoo ng guide & FAQ's (.pdf) Warranty Service Center Agreement (.pdf) Heat Surge Start-Up Kit (.pdf) Heat Surge Warranty Form (.pdf) Circuit Board Replacement For Andong ADL 2000M 2007 fireplace insert (.pdf) Circuit Board Replacement For Andong ADL 2000M 2008 fireplace insert (.pdf) Circuit Board Replacement For Andong ADL 2000M 2009 fireplace insert (.pdf) Heat Surge Model X5C Fire place Insert Service Manual (.pdf) Heat Surge Insert Id er Chart (.pdf) Heat Surge Service Matrix (Please be pa while this file loads) Heat Surge Tech Support Contact Inform on (.pdf) 23 short Remove and Replace videos listed by part. 2012 HS M4417A MS16588R-1 6 330-244-8161