3 & 4-Way Mixing Valves

Similar documents
Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Thermostatic actuator RAVK - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Thermostatic actuator RAVV - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16)

Thermostatic actuator RAVI - for 2-way valves RAV-/8 (PN 10), VMT-/8 (PN 10), VMA (PN 16) - for 3-way valves KOVM (PN 10), VMV (PN 16)

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Integrated Presetting Valves for Normal 013G0372 and Small 013G0373 Volume Flows

Integrated Presetting Valves - for Normal Volume Flows RA-N and for Small Volume Flows RA-U

Automatic Bypass Control AVDO

Powers Controls TH 192 S Single Temperature Room Thermostat

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Thermostatic valve Type AVTA

Data sheet ECC 12 and 22

Assisted lift operated 2/2-way solenoid valves Type EV250B

Powers Controls Free Energy Band TH 193 HC Heating/Cooling Room Thermostat

Thermostatic Sensor RAS-C² with RA-FN Radiator Valve (Fixed Capacity)

Volkswagen B3 Passat General-Engine 4 CYL. 19 Engine - Cooling System (Page GR-19)

Data sheet Thermostatic sensors type RA 2000

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Thermostatic element RAVV for 2-way valves

CGC s Hybrid System Loop Control

Seated valves (PN 16) VF 2 2-way valve, flange VF 3 3-way valve, flange

VC Series Zone Valves BALANCED 2-WAY AND 3-WAY HYDRONIC VALVES

RADIATOR VALVES / MANIFOLD ASSEMBLIES AND DIVERTERS

Mixing Valves. ARGUS Application Note: Mixing Valves

Series TMM Axial Piston Motor. Technical Information

MAKING MODERN LIVING POSSIBLE. Thermostatic valve AVTA. Technical brochure

POWERS Controls No. 4 Pneumatic Damper Actuator

Oil Coolers New DCS Dual Fan models for 45HP and 60HP cooling performance

Stainless Steel Single and Dual Circulation Kits

Check Valves Valve locator

HEAT INTERFACE UNITS (Modular)

Frequently Asked Questions

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

Condensing Boiler Efficiency

Overview of types. Technical data

TA-FUS1ON. Fully adjustable Kvs control and balancing valves. That s just two good.

Flow Control Valves. Note: Also see R04C3 on page DC1. Denotes New Winner s Circle Product Line. Catalog HY /US

S GATE KNIFE GATE VALVE WITH PNEUMATIC ACTUATOR

AIR-AIR PRESSURE MULTIPLIER (BOOSTER)

Pneumatic Shut-off Butterfly Valve Type 3335/31a SRP or DAP

2- and 3-port valves with flanged connections, PN 10

SISTO-16TWA/HWA/DLU. Type Series Booklet

Type overview. Technical data

Butterfly Valves PN 6/10/16 for flanged connection

TECHNICAL INSTRUCTIONS REPAIR KITS Hydroguard Series 420 Thermostatic Valve All Models (1 9)

Flow controller with integrated control valve (PN 16, 25, 40*) AFQM, AFQM 6 - return and flow mounting

V5001S. Kombi-S Shutoff Valve. Product specification sheet

Solenoid valves 2/2-way direct-operated Type EV210A

THERMOSTATIC MIXING VALVE TRIM K-T9493, K-T9494

Installation and Commissioning Manual Solar Stations FlowCon Max Evolution II

RC 195 Multiple Input Receiver-Controller

DN [mm] [m 3 /h] Characterizing disk Dimensions / Weights see «Dimensions and weights», page 3 Motorizing

9013 PUMPTROL Commercial Pressure Switches Type F and 9013 Commercial Pressure Switches Type G. January. Catalog

Spira-trol TM Two-port Control Valves EN Standard KE, KF and KL DN15 to DN300 and ASME Standard KEA, KFA and KLA ½" to 12"

Operators manual Basic water heater

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

CERT. TO ASSE STD 1016 AND AND AND 1017 WT. LBS.

RADIATOR VALVE. type m72. Page 1

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling

Baumann Little Scotty Bronze Control Valve

Data sheet Radiator Thermostats type RA 2000 Valve bodies type RA-FN and RA-G

HDA

08.08 Vic-Check Valves

4 Posiflow Proportional Solenoid Valves

Many Products...One Source

Automatic balancing valves ASV

Q [m 3 /h] Wilo-Star Cast iron body 60 Hz. Star 30 F. Star 21. Star 17 FX Q [US gpm]

Electric Rotary Actuator - On/Off or programmable control actuator

Scraper Passage Indicator. Electrical Indicator. Features

RPE3-04. Functional Description HA /2010. Directional Control Valves Solenoid Operated. Replaces HA /2007

REGULATORS 175/153 Series

MONO BLOCK DIRECTIONAL CONTROL VALVE TS1120TSLB

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Installation and User Instructions Unvented Electric Storage Water Heater Models: S10UNV, S15UNV.

QLM and QLD Series Three-port Control Valves

kymanual or Automatic - it s your Choice

Custom configuration such as modified angle dimensions, other flange standards, 3-way function, alternative materials.are available on request.

3/2- and 2/2-way cartridge valve type BVE

Pressure relief valves Size 6

Accumulators and Receivers

MONO BLOCK DIRECTIONAL CONTROL VALVE TS

Art.S001-S002 SOLAR MODULE WITH DELIVERY AND RETURN CONNECTIONS

Battery Powered Thermal Mass Flow Meters for Gases

4. Combi valves. 7. Fire hydrants. 8. Check valves. 9. Air valves

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

Spare Parts List Activ A 25C Activ A 30C Activ A 35C Activ A 18S Activ A 25S Activ A 30S

Introduction. Angle/Flared/Sequence/Changeover Service Valves. Valves D

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Hydraulic Flow Control Valves

! WARNING. McDonnell & Miller Installation & Maintenance Instructions MM-217(I) Series 150S and 157S (Snap Switch, All Models except 157S-RB-P)

CALEFFI. Compact automatic flow rate regulator with polymer cartridge. 127 series 01166/09 GB

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS Model GENUS PREMIUM FS CUENOD. R EN - Edition 01-26/10/2009

Model 43AP Pneumatic Controller, Style B

GRUNDFOS COMMERCIAL BUILDINGS

Goulds Water Technology

VAD. Variable Area Desuperheaters

XE70 SERIES VC SERIES BALANCED HYDRONIC VALVES 2-WAY AND 3-WAY

Transcription:

& 4-Way Mixing Valves -Way Valve Applications / Features: The ESBE MG series of & 4-way valves are designed to mix water to the appropriate temperature to meet the zone or requirements within heating and cooling s. Through means of mixing or diverting, the fluid temperature leaving the valve is regulated by the MG. The valves are designed to operate within closed loop s through manual operation or automatically when used with the 60 or 90 Series electronic motor actuator that is typically connected to an outdoor reset controller, DDC or boilers with integrated controls. Features: MG series mixing valves are a rotary design allowing for great flexibility in field piping layout. Compact valve size. Valve position face plate is graduated on both sides and can be rotated allowing a choice of mounting position. Easily adaptable with ESBE electronic motor actuator series 60 or 90. Suitable fluid: water (maximum 0% glycol) Ordering: -Way Valve Code No. Connection Leakage in % of flow Cv* Size Type Mixing Diverting Body Reference 06B890 /2 2.9 0. 0.0 MG -2. 06B89 /4 4. 0. 0.0 MG 20-4 06B890 /4. 0. 0.0 -Way MG 20-6. 06B892 9. 0. 0.0 DZR Brass MG 2-8 06B8968 4 0. 0.0 MG 2-2 06B8969 -/4 2 0. 0.0 MG 2-8 Code No. Connection Cv* Leakage in % of flow Size Type Mixing Body Reference 06B898 /2 2.9.9 4MG -2. 06B8982 /4 4.. 4MG 20-4 06B898 /4. 4MG 20-6. 06B8984 9. 4MG 2-8 06B898 4 4-Way Brass 4MG 2-2 06B8986 -/4 2 4MG 2-8 06B896 /4 2.9 4MG 20-2. 06B8990 Solder. 4MG 2-6. 06B899 -/4 4 4MG 2-2 * Cv = Flow rate allowed by the valve in GPM with a pressure drop of one psi. VDKIB22 Danfoss 0/08

& 4-Way Mixing Valves Ordering (Cont.): Accessories Code No. Valve Sizes Style 082F896 Gasket Set /2 to -/4 082F89 /2 to (06B892) -way Complete Interior 06B896 (06B8968) to -/4 082F896 Gasket Set /2 to /4 082F89 /2 to (06B8984) 4-way Complete Interior 06B89 (06B898) to -/4 Technical Specifications: Max. operating pressure Max. operating temperature Min. operating temperature Max. differential pressure Max. torque Allowable fluid psi ( bar) 26 F ( C) 4 F (- C) 4. psi (.0 bar) 26 in. lb. (Nm) Closed loop ) Water hydronic 2) Glycol mixture, max. 0% % Hot Water 0 90 80 0 60 0 40 0 20 0 0 9 Valve Position Flow (GPM) 0 0 20 2 2-8 2-2 2-8 20-6 20-4 -2 0. 0. 0.2 0. 0. 2 4 Pressure drop psi Cv 2 4 9.. 4. 2.9 VDKIB22 Danfoss 0/08 2

& 4-Way Mixing Valves Piping Arrangement: -Way Valves Ideal valves for mixing and diverting applications. Reduces risk of low temperature water returning to boiler. s Double mixing function, providing proportional mixing from to and to. Reduces risk of low temperature water returning to boiler. Mixing From To To Return from Diverting From Return from From To Return to Return to Faceplate: The valve position plate is graduated on both sides and can be adjusted to correspond to the installation. After the removal of two flat head screws, the cover plate can be installed to match the piping orientation. 9 9 9 0 0 9 0 0 -Way Valve VDKIB22 Danfoss 0/08

ESBE Type MG & 4-Way Mixing Valve Typical Installation: -Way Valve DIVERTING MIXING Pipe Primary Secondary Pipe Primary Secondary Low Temp. Terminal Unit Low Temp. Terminal Unit MIXING Pipe Primary Secondary System Loop Pump Mixing Loop Pump Low Temp. Terminal Unit Construction: 2 4 6 No. Type MG Type 4MG Valve Body Brass DZR CW 602N Brass CW 64N 2 Slider Brass DZR CW 602N Brass CW 64N Stem Brass DZR CW 602N Brass CW 64N 4 O-ring EPDM EPDM Bushing Plastic Plastic 6 Cover Plate Zinc Zinc VDKIB22 Danfoss 0/08 4

ESBE Type MG & 4-Way Mixing Valve Dimensions: D A B C Way Valve Dimensions Code Number Reference 06B890 MG -2. /2 Connection A B C D Weight Size Type inch mm inch mm inch mm inch mm lb. kg.42 6 2.8 2.26 2 2.6 0.4 0. 06B89 MG 20-4 /4.42 6 2.8 2.26 2 2.6 0.2 0.6 06B890 MG 20-6. /4.42 6 2.8 2.26 2 2.6 0.4 0. 06B892 MG 2-8.42 6 2.8 2.26 2 2.6 0.4 0. 06B8968 MG 2-2. 44.46 88.42 6 2.9 4 2.20.0 06B8969 MG 2-8 -/4. 44.46 88.46 2.9 2.20.0 D A B C 4 Way Valve Dimensions Code Number Reference 06B898 4MG -2. /2 Connection A B C D Weight Size Type inch mm inch mm inch mm inch mm lb. kg.42 6 2.8 2.26 2 2.6 0.98 0.9 06B8982 4MG 20-4 /4.42 6 2.8 2.26 2 2.6 0.6 0.8 06B898 4MG 20-6. /4.42 6 2.8 2.26 2 2.6 0.6 0.8 06B8984 4MG 2-8.42 6 2.8 2.26 2 2.6 0.98 0.9 06B898 4MG 2-2. 44.46 88.42 6 2.9 4 2.4. 06B8986 4MG 2-8 -/4. 44.46 88.46 2.9 2.6.2 06B896 4MG 20-2. /4.42 6 2.8 2.26 2 2.6 0.6 0.8 06B8990 4MG 2-6. Solder.42 6 2.8 2.26 2 2.6 0.98 0.9 06B899 4MG 2-2 -/4. 44.46 88.46 2.9 2.6.2 VDKIB22 Danfoss 0/08

& 4-Way Mixing Valves ESBE -Way Spare Parts ESBE 4-Way Spare Parts Item No. Knob 2 Screw - Body Screw - Scale Plate 4 Scale Plate Cover Plate O Ring 9 Plug / Spindle /2 to (06B892) (06B8968) to -/4 6-8 Gasket Set 082F896 082F896 - Interior Complete 082F89 082F896 Item No. Knob 2 Screw - Body Screw - Scale Plate 4 Scale Plate Cover Plate O Ring 9 Plug / Spindle /2 to (06B8984) (06B898) to -/4 6-8 Gasket Set 082F896 082F896 - Interior Complete 082F89 082F89 Typical Specification: The mixing/diverting valve shall have a rotary design capable of 90 rotation within a brass construction. The valve body shall have a removable face plate graduated on both sides and able to be flipped and rotated providing flexibility of valve orientation. The valve shall be capable of accepting an ESBE 60 or 90 series electronic motor actuator. The valve shall be an ESBE series MG valve. Danfoss can accept no responsibility for possible errors in printed materials and reserves the right to alter its products without notice. All trademarks in this material are property of the respective companies. Danfoss and Danfoss logotype are trademarks of Danfoss A/S. All rights reserved. Danfoss Inc. 6 Mississauga Road, Suite 4 Mississauga, ON, LN 2W Tel.: 90-28-200, Fax: 90-28-20 www.na.heating.danfoss.com Danfoss Inc. 94 Corporate Drive Baltimore, MD 226 USA Tel.: 44-2-0266, Fax: 44-2-020 www.na.heating.danfoss.com VDKIB22 Danfoss 0/08