High Frequency Ventilation Outline Part A

Similar documents
MECHINICAL VENTILATION S. Kache, MD

Comparison of the Rate of Improvement in Gas Exchange between Two High Frequency Ventilators in a Newborn Piglet Lung Injury Model

High-Frequency Oscillatory Ventilation

Impact Uni-Vent 754 Portable Ventilator

Understanding Anesthetic Delivery Systems Dean Knoll, CVT, VTS (Anes.) Anesthesia Technician Supervisor University of Wisconsin Madison, WI May 2003

Common Ventilator Management Issues

Artificial Ventilation Theory into practice

Mechanical Ventilators

ACUTE RESPIRATORY DISTRESS SYNDROME (ARDS) S. Agarwal, MD, S. Kache MD

Critical Care Therapy and Respiratory Care Section

3100B Clinical Training Program. 3100B HFOV VIASYS Healthcare

MECHANICAL VENTILATION IN THE NEONATE

Children's Medical Services (CMS) Regional Perinatal Intensive Care Center (RPICC) Neonatal Extracorporeal Life Support (ECLS) Centers Questionnaire

Mechanical Ventilation

Ventilation Perfusion Relationships

Ventilator Application of the Passy-Muir Valve David A. Muir Course Outline Benefits Review of the Biased Closed Position No Leak Passy-Muir Valves

Oxygenation and Oxygen Therapy Michael Billow, D.O.

5/30/2014 OBJECTIVES THE ROLE OF A RESPIRATORY THERAPIST IN THE DELIVERY ROOM. Disclosure

Airway Pressure Release Ventilation

RESPIRATORY VENTILATION Page 1

Ventilators/Transport*

Safe Zone: CV PIP < 26; HFOV: MAP < 16; HFJV: MAP < 16 Dopamine infusion up to 20 mcg/kg/min Epinephrine infusion up to 0.1 mcg /kg/min.

Home Ventilator Breath of Life Home Medical Equipment and Respiratory Services

GRADE 11F: Biology 3. UNIT 11FB.3 9 hours. Human gas exchange system and health. Resources. About this unit. Previous learning.

Impact Uni-Vent 750 Portable Ventilator

GE Healthcare. Welcome to the future of anesthesia Aisys * Carestation *

High Frequency Ventilation Introductory Information

Gas Exchange. Graphics are used with permission of: Pearson Education Inc., publishing as Benjamin Cummings (

PULMONARY PHYSIOLOGY

GUIDELINES FOR THE MANAGEMENT OF OXYGEN THERAPY

Gas Exchange Graphics are used with permission of: adam.com ( Benjamin Cummings Publishing Co (

Pediatric Airway Management

For every breath he takes. Trilogy200 ventilator s added sensitivity lets you breathe easier knowing your patients are where they belong home.

A. All cells need oxygen and release carbon dioxide why?

Neurally Adjusted Ventilatory Assist: NAVA for Neonates

Department of Surgery

For over 40 years, the leader in. nitrous oxide. equipment technology.

Puritan Bennett 980 Ventilator Patient Setup Quick Reference Guide

ASSISTED VENTILATION IN NEONATES

Pathophysiology of hypercapnic and hypoxic respiratory failure and V/Q relationships. Dr.Alok Nath Department of Pulmonary Medicine PGIMER Chandigarh

Oxygenation. Chapter 21. Anatomy and Physiology of Breathing. Anatomy and Physiology of Breathing*

Understanding Hypoventilation and Its Treatment by Susan Agrawal

Keeping your lungs healthy

Auto Flow 20 Questions 20 Answers. Joseph Fitzgerald

LUNG VOLUMES AND CAPACITIES

POLICIES & PROCEDURES. ID Number: 1115

Pediatric Respiratory System: Basic Anatomy & Physiology. Jihad Zahraa Pediatric Intensivist Head of PICU, King Fahad Medical City

Scope: Applies to the various anesthesia vaporizers used to deliver a known concentration of vaporized liquid. Sample. Type Interval Time Required

2000 Respironics, Inc. All rights reserved.

Pulmonary Ventilation

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

INTRODUCING RESMED S. Home NIV Solutions. S9 VPAP ST-A with ivaps S9 VPAP ST. Why choose average when you can choose intelligent?

From AARC Protocol Committee; Subcommittee Adult Critical Care Version 1.0a (Sept., 2003), Subcommittee Chair, Susan P. Pilbeam

Arterial Blood Gas Case Questions and Answers

Titration protocol reference guide

Air-Oxygen Blender. Service Manual. Model No. PM5200 Series PM5300 Series (shown)

CHEST TUBES AND CHEST DRAINAGE SYSTEMS

Extracorporeal Life Support Organization (ELSO) Guidelines for Neonatal Respiratory Failure

Oxygen Therapy. Oxygen therapy quick guide V3 July 2012.

Respiratory failure. (Respiratory insuficiency) MUDr Radim Kukla KAR FN Motol

RESPIRATORY THERAPIST CLASSIFICATION SERIES

Powers Controls TH 192 HC Heating/Cooling Room Thermostat

Sensors / Modules / Monitors. Breath Gas Sensing and Monitoring. For life supporting systems in intensive, emergency and ambulant care

Introduction to Cardiopulmonary Exercise Testing

Trilogy200. Proximal pressure line. Exhalation valve line. Quick start guide. Overview. Circuit set-up. Set-up screen. Prescription set-up

Pre-lab homework Lab 6: Respiration and Gas exchange

IMPAIRED BLOOD-GAS EXCHANGE. Intraoperative blood gas analysis

MEDICAL SYSTEMS. Monnal T60. Touch and Breathe.

Basic techniques of pulmonary physical therapy (I) 100/04/24

Cardiopulmonary Physical Therapy. Haneul Lee, DSc, PT

Paediatric Intensive Care unit Nursing Procedure: Care of the ventilated child

The Berlin definition of Severe ARDS includes assessment of which of the following?

Respiratory failure and Oxygen Therapy

Nursing Education and Research

240- PROBLEM SET INSERTION OF SWAN-GANZ SYSTEMIC VASCULAR RESISTANCE. Blood pressure = f(cardiac output and peripheral resistance)

OPTIMAL PEEP DETERMINATION

VSO MAX HP High Flow Proportional Valve

Operating Instructions & Maintenance Guidelines for Precision Vaporizers

Operator s Instruction Manual

Pulmonary Diseases. Lung Disease: Pathophysiology, Medical and Exercise Programming. Overview of Pathophysiology

DISSOLVED OXYGEN METER Model : DO-5509

The Anesthesia Ventilator

ELSO GUIDELINES FOR TRAINING AND CONTINUING EDUCATION OF ECMO SPECIALISTS

Two Steps forward in Ventilation. Ernst Bahns. Because you care

Neonatal Reference Guide

NEEDLE THORACENTESIS Pneumothorax / Hemothorax

The Anesthesia Ventilator

Milwaukee USER MANUAL

Oxygen - update April 2009 OXG

Datex Ohmeda. Centiva /5. Service Manual Software rev. 2.1n

How To Determine The Difference Between Long Versus Short Inspiratory Times In Neonates

Standard Operating Procedure

PROP Acute Care/Rehab Discharge Planning Requirements 1. PROP Medical Criteria 2. PROP Prescription for Services 3

Aespire View. User s Reference Manual. Software Revision 6.X

Management of airway burns and inhalation injury PAEDIATRIC

What, roughly, is the dividing line between the upper and lower respiratory tract? The larynx. What s the difference between the conducting zone and

Hypoxia and Oxygenation Hypoxia is a serious threat to patients and escorts alike when

2.06 Understand the functions and disorders of the respiratory system

CHAPTER 1: THE LUNGS AND RESPIRATORY SYSTEM

Transcription:

High Frequency Ventilation Outline Part A 1. How is this ventilator classified? 2. Ventilator Concept (brief theory of operation and features) -What in the World is a Phasitron? -Operator Set Parameters -Variable Parameters -Indications -Contraindications 3. An overview of the device (an in-service) including an explanation of the modes of ventilation and how to set them up (what knobs to turn) -Ventilator Overview and Controls -Ventilation and Oxygenation Ventilation Oxygenation -Clinical Application Conclusion 4. Ventilator Circuit set up, Functional Checks. Ventilation.where do you start? Use with Nitric Oxide -Set up and Functional Check Set-up Procedure Functional Check -The Bronchotron with Nitric Oxide 5. Which disease processes do best with what ventilator settings and why -Strategies for Clinical Management

6. Clinical things to look for and be aware of during flight when using this device 7. Why is this device so useful on transport and how has using this device changed things for your transport team, and the way you care for the patient during transport. 8. Discuss how the device can be mounted or positioned during transport (configurations) 9. Provide clinical tips regarding use of this device (tips that make things easier or less complicated) 10. Are there any special considerations when integrating this device into your transport program (education, mounting/configuration issues, regulations, calibration, maintenance)

High Frequency Ventilation 1. How is this ventilator classified? The Bronchotron is classified as a pneumatically powered, pressure limited, time cycled, high frequency flow interrupter. As the name implies the Bronchotron allows the operator to control CO2 removal (ventilation) and oxygenation (diffusive). 2. Ventilator Concept (brief theory of operation and features) Compared to conventional ventilators the Bronchotron delivers high frequency or conventional IMV breaths. With the unique Phasitron, which is the mechanical/physiological interface, these breaths are precisely delivered to selected pressures. (see below). Exhalation is passive, to a selected operator programmed baseline. -What in the World is a Phasitron? The Phasitron is the Mechanical/Physiological interface. The Phasitron is a sliding venturi that acts as both the inhalation and exhalation valve As gas is pulsed through the jet orifice, humidified and blended gases are entrained through the entertainment port and delivered to the patient at programmed limits As PIP is reached and the lungs are inflated, backpressure is reflected to the venturi throat. As pressure is increased downstream of the venturi, flows automatically decrease. This protects the lungs from dissecting pressures and flows and has been given the term fluidic clutching. The Phasitron also allows for Oscillatory Equilibrium which is, during the inspiratory phase the desired PIP is reached and held, inspiratory and expiratory volumes equalize, further enhancing diffusion and the mixing of gases (see diagram below).

-Operator Set Parameters PIP/Amplitude CMV/High Frequency Rate FIO2 PEEP/Mean Airway Pressure ((Paw), -Variable Parameters Flow Tidal Volume -Indications Respiratory failure Significant air leak syndrome Failing conventional ventilation -Contraindications Untrained individual managing ventilator 3. An overview of the device (an in-service) including an explanation of the modes of ventilation and how to set them up (what knobs to turn) -Ventilator Overview and Controls Air/Oxygen Blender (If Equipped) Adjusts FIO2 when ventilator is attached to an air and oxygen gas source. Operational Pressure Knob Adjusts the working pressure of the ventilator. Set to 40 psi. for HF Ventilation Set28-30 psi. for Conventional Ventilation Alarms 9 volt battery powered pressure drop alarm with user set time delay.

Integrated Mean Airway Pressure Control Knob On position displays Integrated Mean Airway Pressure OFF position displays breath-by-breath proximal airway pressures Adjust PEEP valve for desired Paw in HF ventilation Rate Counter (Frequency Counter) 60=1Hz When power button is depressed the counter will remain on for 5 minutes and count the high frequency breaths. Mean Pressure By setting the Peep level you are setting the Mean Pressure

Rate (HFV Frequency Control Knob) Controls high frequency rate from 200-800bpm with an automatic I:E ratio. Amplitude (HFV Flowrate Control Knob) Determines the amplitude of the high frequency breaths. Ventilator Set Up for High Frequency Ventilation Follow steps 1-5 (above) for ventilator set up for high frequency

I Time (Inspiratory Time Knob) Controls the inspiratory time of the conventional breath.3 sec.- Hold. PIP (CMV Rate Flowrate Control Knob) Controls the PIP during the conventional breath. E Time (Expiratory time Knob) Controls the expiratory time of the conventional breath.3 sec.- Hold. Ventilator Set Up for Conventional Ventilation Follow the steps (above) for conventional ventilator set up

-Ventilation and Oxygenation Ventilation -Control over arterial PCO2 is achieved by manipulating delivered volumes and less on frequency changes. -Know the physiology of the machine as well as the disorder you are treating.. -CMV = VCO 2 = V T X f -Increase PIP in 2-3 cm H2O increments -PIP is directly related to Tidal Volume delivery -Assessment of PIP in the face of small ET tubes is important -Small or undersized ET tubes may cause under ventilation if not considered -Change rate to increase minute ventilation.. -HF = VCO 2 = (V T ) 2 X f -Amplitude: small changes in tidal volume are very powerful -Decrease oscillatory frequency, the lower the high frequency rate the greater the inspiratory time the more high frequency volume delivered. *Make one change at a time and wait for stabilization before making subsequent changes. Oxygenation -Control over arterial PO2 is achieved by the manipulation of mean airway pressure and or FIO2. -A near linear relationship exists between lung volume and oxygenation. The parameters that will have the most effect over oxygenation in order of importance are: -Increase FIO2 to increase alveolar po2 in both CMV and HFV -Increase Oscillatory CPAP/PEEP (Paw), Increase PIP. This has direct effect in mean airway pressure. -Normal mean lung volume is proportional to mean airway pressure -Tidal volumes are so small, need to have optimal lung volumes or expansion -Fine line with lung volume. Major short -term impact of excessive lung volume may be impaired blood flow and trauma. -Amplitude (tidal volume)-effects ventilation -Not much affect on O2 except if patient has atelectasis or patchy infiltrates may open up lung and improve oxygenation i.e. MAS or pneumonia. -Using amplitude to improve oxygenation usually means Paw is to low. -Increase Pulse Frequency -High frequencies produce a greater mean airway pressure -Faster you go, more likely to air trap -Increased rate in air trapping disorder will decrease oxygenation due to air trapping.

-Clinical Application Conclusion In the face of a difficult clinical scenario with worsening ventilation and or oxygenation, complete assessment of the patient should be made to find the cause for V/Q inequalities. Ventilation Oxygenation Perfusion Lungs over-distended FiO2 Blood volume to low Alveolar hypoventilation Sepsis Ventilator induced hypovolemia Secretions Low hematocrit Edema Bronchoconstriction Pneumothorax Why is High frequency ventilation if Necessary? -Change in regionalization of care -Availability of HFV -Availability of NO -Decrease in number of ECMO centers -Severity of cardiopulmonary dysfunction 4. Ventilator Circuit set up, Functional Checks. Ventilation.where do you start? Use with Nitric Oxide -Set up and Functional Check Set-up Procedure Set up using standard Percussionaire HF transport-breathing circuit (A50605) connected to Percussionaire test lung (B11048). -Open PEEP valve to full counterclockwise position. -Connect to a 50-psi gas source. -Insure Manometer needle is zero- If required remove cover of manometer and adjust calibration screw and or connect to Universal Monitron Functional Check -Rotate CMV Inspiratory Time to the full counterclockwise position. -Rotate CMV Expiratory Time to the 12:00 position.

-Rotate CMV Flowrate control to the full clockwise position. -Rotate Percussion control to full clockwise position. -Rotate IPV Flowrate control full counterclockwise. -Observe a frequency of 185-210 bpm. -Rotate IPV Flowrate clockwise. -Observe a gentle decrease in amplitude until off at the full clockwise position. -Rotate IPV Flowrate to full counterclockwise position. -Rotate Percussion control slowly to full counterclockwise position. -Observe an increase in frequency. -Max frequency should be >700bpm. -Rotate IPV Flowrate to the full off clockwise position. -Rotate CMV Inspiratory Time control to the 12:00 position. -Rotate CMV Flowrate control to the 12:00 position. -Observe an inspiratory time of approx. 2 seconds. -Observe an expiratory time of approx. 2 seconds. -Observe a rate <20bpm >12bpm. -Rotate PEEP valve from open to close position-observing change in baseline pressure. -Rotate CMV Flowrate from full counterclockwise to full clockwise off position. -Observe an increase and decrease in Peak Inspiratory pressure (PIP). -Rotate Inspiratory Time control full clockwise. -Rotate Expiratory Time control full counterclockwise. -Rotate CMV Flowrate control to 12:00 position. -Observe a rate of >39bpm. -The Bronchotron with Nitric Oxide -Set up Phasitron and tubing -Place capped NO adapters on Phasitron -Set desired HFV settings -Set up Aeronox -When the system flush is complete, connect delivery and sample line to nitric adapters -adjust NO to desired level -PPM will fluctuate with any change in Bronchotron settings.

5. Which disease processes do best with what ventilator settings and why -Strategies for Clinical Management Hyaline Membrane Disease / Diffuse Alveolar Disease in the Preterm -Mean airway pressure: 1-2cm H20 > conventional ventilation -Frequency: 500 bpm -Amplitude: Chest wall movement Diffuse Alveolar Disease in the Term / Near Term -Mean airway pressure: 2-4cm H20 > conventional ventilation -Frequency: 500 bpm -Amplitude: Chest wall movement Pneumonia / Sepsis (focal pneumonia) -Mean airway pressure: equal to or 1 cm H20 < conventional ventilation -Frequency: 380-420 bpm -Amplitude: Chest wall movement Meconium Aspiration (with air trapping) -Mean airway pressure: equal to conventional ventilation -Frequency: 350-400 bpm -Amplitude: Good chest wall movement Meconium Aspiration (diffusely hazy) -Mean airway pressure: 2-5cm H20 > conventional ventilation -Frequency: 350-500 bpm -Amplitude: Good chest wall movement Pulmonary Hypoplasia (uniform) -Mean airway pressure: equal to conventional ventilation. Advance 1 cm H20 until oxygen saturation increases - -Frequency: 500 bpm -Amplitude: Minimal chest wall movement Pulmonary Hypoplasia (non-uniform) -Mean airway pressure: equal to or 1-2cm H20 > conventional ventilation -Frequency: 500 bpm -Amplitude: Chest wall movement Severe Air Leak in the Preterm (PIE) -Mean airway pressure: 1 cm H2O < conventional ventilation -Frequency: 500 bpm -Amplitude: Minimal chest wall movement Gross Air Leak in the Preterm -Mean airway pressure: equal to or 1 cm H20 > conventional ventilation -Frequency: 500 bpm -Amplitude: Chest wall movement Gross Air Leak in the Term / Near Term -generally poor inflation -Mean airway pressure: 1-2 cm H20 > conventional ventilation

-Frequency: 500 bpm -Amplitude: Chest wall movement Persistent Pulmonary Hypertension of the Neonate -Mean airway pressure: equal to conventional ventilation -Frequency: 350-420 bpm -Amplitude: Adjust amplitude for alkalosis if needed 6. Clinical things to look for and be aware of during flight when using this device -CXR after stabilized on HF -Aeration, rib expansion -Check where liver is, rib spacing -Make sure ETT is secure before moving patient -Difficult to assess chest wiggle on the road TCM is nice, I-stat -Paw can drift if patient compliance changes -Watch vent settings closely while plugging and unplugging from hospital/aircraft/ambulance 7. Why is this device so useful on transport and how has using this device changed things for your transport team, and the way you care for the patient during transport. -pneumatically driven, no EMI interference -small and lightweight -can deliver both HFV and CMV -gas consumption -compatible with NO -decrease barotrauma -improve pt stability -patients already on HFV easier to move 8. Discuss how the device can be mounted or positioned during transport (configurations)

9. Provide clinical tips regarding use of this device (tips that make things easier or less complicated) -carry spare parts -Grease O rings when cleaning tubing and putting phasitron back together -Peep valves break easily, we replace them yearly -not able to achieve chest wiggle, PIP etc change diaphragm -Frequency does not always read out when on test lung start w/ballpark, adjust on patient. -One adjustment may change other settings. -2.0 ETT, made need to really increase settings to effectively oxygenate/ventilate patient. 10. Are there any special considerations when integrating this device into your transport program (education, mounting/configuration issues, regulations, calibration, maintenance)