Hilti. Outperform. Outlast. Hilti, Inc. (U.S.) en español Hilti Firestop Systems Guide 2007

Similar documents
Flamesafe Firestopping Products. Firestopping Products.

Tremco Fire Protection Systems Group Technical Bulletin

Fire Barriers & Fire Stopping

Services Enclosures and Protected Shafts - Maintaining Compartmentation

Whitepaper. Modular Substation Cable Termination Design. Author: Allan Bozek P.Eng, MBA, EngWorks Inc, Calgary, Canada

FIRESTOPPING. Cable. Firestopping is the technology used to

Excerpts from the Canadian National Building Code (NBC)

Terms and Definitions In Canada

Passive Fire Protection

Enclosures DuraSystems Barriers, Inc. The Passive Fire Protection Specialists

HARTING Ethernet Cabling 4-poles Overview

Value Engineering Considerations for Cast Iron Soil Pipe and PVC in Commercial Sanitary and Storm Drainage Applications

Conduit Fittings & Accessories Directional Drilling Conduit Utility Duct Telephone Duct Residential Boxes

FIRESTOPPING & SMOKE SEALS

Complete Firestop Systems Guide

Shower and Floor Gullies Channel Drain and Tile Drain SECTION

Fire Collars For Plastic Pipe Penetration

Electrical for Detached Garages: Updated Feb 19, 2016 for 2015 CE Code in force Jan. 1, Underground branch circuit feeding a detached garage:

Mini USB and USB 2.0-IP67 Connector System

Quick Connect Boxes Inside Gloveboxes

Retardants Inc. The Decision You Make May Save A Life! 123 Columbia Court North Suite 201 Chaska, MN 55318

Saferand easierinstallation

HARTING Ethernet Cabling 8-poles Overview

FSD35, FSD36 AND FSD37 COMBINATION FIRE and SMOKE DAMPERS

STANDARD SPECIFICATION. for. Plumbing, Heating, Hot Water, Cold Water & Electrical work. Sussex Lodge London W2 & 16 Stanhope Terrace London W2

Built to Last. Built for Beauty. Good. Solid. Logix. TM

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

The National Armored Cable Manufacturers Association Presents. Installation Standard for Types AC and MC Cables

SERVICE LINE EXTENSION AND SERVICE LINE CONNECTION CONDENSED SANITARY SEWER SYSTEM INSTALLATION SPECIFICATIONS

PIPE SUPPORT & ALIGNMENT SYSTEM CATALOG

RESIDENTIAL ROOFING & RE-ROOFING, ROOF VENTILATION AND ROOF SHEATHING REQUIREMENTS MICHIGAN RESIDENTIAL CODE 2000

Scepter PVC Molded Junction Boxes

Refrigeration Installation 101

foot skylight) is enough to knock a worker off their feet. A 10 mph wind gust on a 5 x 6 skylight develops a wind force of 270 lbs.

FIRE AND SMOKE PROTECTION FEATURES

GYPSUM AREA SEPARATION FIREWALLS GA

Steel Fire Sprinkler Pipe

Waterproof Connectors for Outdoor Use

Fixtures - Parts - Accessories to shampoo bowls

800 Communications Circuits

Roxul Board Insulation Section Master Guide Specification (CAVITYROCK DD) Page 1 October 2013

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

FIRE-RESISTANCE-RATED CONSTRUCTION

EcoTouch Insulation with PureFiber Technology

Plumbing. Helpful Hints Residential Construction. Lincoln County. Bert Polk Plumbing Inspector

SECTION HANGERS AND SUPPORTS FOR HVAC PIPING AND EQUIPMENT

FIRE-RESISTANCE-RATED CONSTRUCTION

Sealed Industrial Ethernet Circular IP67 Cat. 5e RJ45 Connector System

FIRE-RESISTANCE RATINGS WITH STEEL JOISTS

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles

STABILOY BRAND FeeDeR SOLuTIONS

ISO Types 1-6: Construction Code Descriptions

Introduction to cable fire stopping

6000 Series Buccaneer

Chapter 3 Pre-Installation, Foundations and Piers

SOURIAU s discrete wire sealing

Firestopping & Fireblocking:

NORTH ORANGE COUNTY COMMUNITY COLLEGE DISTRICT SECTION GROUNDING AND BONDING FOR COMMUNICATION SYSTEMS

ELECTRICAL GUIDELINES FOR SINGLE-FAMILY HOME OWNERS:

Scepter PVC Molded Junction Boxes

HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

Reticulation sewers in basements Technical guidelines

FLEX-WRAP Foam Pipe Wrap

6000 Series Buccaneer. 30 twist locking Tamperproof lock prevents accidental un-mating. Cat 5e shielded coupler Maintains shielding

SECTION LS 2530 SANITARY SEWERS. A. General: Submit the following in accordance with The General Conditions.

ASX7-4-IOM-7 J

STABILOY BRAND FeeDeR SOLuTIONS

Replacement of Heating, Ventilation, Air Conditioning (HVAC) Units In Apartments Located at 641 Fifth Avenue. Photo Essay

Installation Instructions

14 PHOENIX CONTACT Courtesy of Power/mation Energy Lane, Saint Paul, MN

first look at GigaCrete s revolutionary new New Construction GigaHouse GigaHouse Utilizing GigaPanel

INDEX. Sec. No. Items Page Nos.

400 Series Buccaneer BUCCANEER POWER. bulgin

RESIDENTIAL PLUMBING ALTERATIONS PERMIT REQUIREMENTS

APR 2016 Rev M

San Antonio Water System Standard Specifications for Construction ITEM NO SLIP-LINING SANITARY SEWERS

High Density Polyethylene Liners for Rehabilitation of Corroded Pipelines

Decree of the Ministry of the Environment on fire safety of ventilation systems

If you are a web registered user of ArlingontPermits.com you may also request an inspection at:

Terminal Boxes Series 8146

Fire Barrier Duct Wrap 15A

Hilti KWIK HUS-EZ I (KH-EZ I) Internally Threaded Carbon Steel Screw Anchor

PVC Pipe PVC SCHEDULE 40. Nominal Pipe Size (in.) 1/8. Average I.D. O.D.

MOBILE HOME SERVICE REQUIREMENTS GAS

FIRE RATED WIRING. What the FT4! Paul Latreille, C.E.T. Ottawa Branch Manager

B. Product Schedule: For each penetration firestopping system. Include location and design designation of qualified testing and inspecting agency.

FOUNDATION INSULATING SYSTEM, INCLUDING WATERPROOFING AND DAMP PROOFING

Composite Panel Firewall Systems

CHAPTER 6 CONSTRUCTION TYPES

Cardok Sàrl CP37 CH-1295 Tannay Switzerland Phone:

SECTION STORM DRAINAGE SYSTEM

Reliable, Consistent, Quality

Fire Performance Standard

4 Installation Requirements

Hanson Building Products. precast basement solutions

Rooflight INSTALLATION INSTRUCTIONS

LS 2540 SEWER LATERALS AND INSPECTION TEES

2014 NEC Guide Lines for Home Owner Doing Electrical Work on their Property

Building Code Clarifications - 7. Fire Resistance

Transcription:

Product Information CP 680-P and CP 680-M Cast-In Firestop Devices For use in Dust and fiber free environments such as hospitals, computer centers and laboratories Concrete floor assemblies rated up to 4 hours A one-step cast-in firestop device for a variety of pipe materials and diameters Helps reduce labor costs and increase productivity Ready-to-use out of the package Internationally tested and approved by UL and FM Reduces the chance of project delays due to failed inspections Product Features Quick & simple installation SpeedLine Alignment system promotes faster layout QuickTurn System creates fast, simple vertical connections Integrated moisture and smoke seal Innovative adapter for metal deck applications Installation & Applications Concrete floors from 2.5" (63 mm) thickness for either flat concrete or concrete over metal deck CP 680-M: - Insulated and non-insulated metal pipes - EMT and electrical conduits - Cable bundles - Multiple pipes CP 680-P: Addresses all applications for CP 680-M as well as the following: - Plastic pipes such as PVC, CPVC, ABS, ENT and FRPP - Fresh and waste water pipes Not suited for Areas with high condensation Outdoor areas Wall applications CP 680-P in concrete over wood forms CP 680-M in concrete over wood forms CP 680-P and CP 680-M Technical Data ID Footprint Opening Required thru Metal Deck 2" 3-3/4" x 4-1/2" 3-1/2" diameter 3" 4-3/4" x 5-5/8" 4-1/2" diameter 4" 6-3/8" x 6-3/4" 5-1/2" diameter 6" 9" x 9-1/2" 7-1/4" diameter Expansion temperature 392 F (200 C) Expansion rate 1:50 (unrestrained) 1:30 (Load expansion, Load = 20g/cm 3 ) Standard Height 8" Temperature resistance Maximum 212 F (100 C) CP 680-P: red CP 680-M: black Approvals California State Fire Marshal Listing No. 4485-1200:135, 4485-1200:136 City of New York MEA 1-07-M, MEA 2-07-M Tested in accordance with UL 1479 ASTM E 814 ULC-S115 Internationally tested and approved FIRESTOP DEVICE FOR USE IN THROUGH-PENETRATION FIRESTOP SYSTEMS SEE UL FIRE RESISTANCE DIRECTORY 5N76 CP 680-P over metal deck FM APPROVED CP 680-M over metal deck Before handling, read Material Safety DataSheet and product Instructions below are general guidelines always refer to the applicable drawing in the UL Fire Resistance Directory or Hilti Firestop Systems Guide for complete installation information Instructions for use Before pouring concrete, secure the cover cap in place, thereby preventing the flow of concrete into the cast-in device. Do not use for wall applications. Hilti Firestop Saving Lives through innovation and education Concrete floor with metal decking For concrete floor with metal decking applications use the correct size CP 680 Metal Deck Adapter for installed cast-in device and follow the illustrations. 1 2 3 4 5 6 Concrete floor Installation option Follow the illustrations if CP 680 has to be cut to slab thickness before installation, or when riser clamps are used. Hilti. Outperform. Outlast. Hilti, Inc. (U.S.) 1-800-879-8000 www.us.hilti.com en español 1-800-879-5000 Hilti Firestop Systems Guide 2007 1 2 3 4 1 2

Product Information Height Extension For use when concrete slabs are greater than 8" thick Device may add up to 6" with each extension kit QuickTurn Connection system promotes a fast, positive connection to the top of the appropriate cast-in device Red (CP 680-P) and Black (CP 680-M) versions create for easier identification when both combustible and non-combustible penetrants are employed for the same project CP 680-P Kit Red cylinder with Red coupling band CP 680-M Kit Black cylinder with Red coupling band Metal Deck Adapters For use with concrete over metal deck applications 6" cylinder extension protrudes through even the thickest spray fireproofing QuickTurn Connection system promotes a fast, positive connection to the underside of the appropriate cast-in device Red (CP 680-P) and Black (CP 680-M) versions create for easier identification when both combustible and non-combustible penetrants are employed for the same project Opening Required to Place the Cylinder Through a Metal Deck For 2" Devices 3-1/2" diameter For 3" Devices 4-1/2" diameter For 4" Devices 5-1/2" diameter For 6" Devices 7-1/4" diameter CP 680-P Kit Red cylinder with two (2) metal plates CP 680-M Kit Black cylinder with two (2) metal plates Hilti. Outperform. Outlast. Hilti, Inc. (U.S.) 1-800-879-8000 www.us.hilti.com en español 1-800-879-5000 Hilti Firestop Systems Guide 2007 Hilti Firestop Saving Lives through innovation and education

Product Information Water Barrier Module A pre-installed water barrier solution that impedes water Meets W-Rating requirements for select penetrants For use where a single penetrant is employed per cast-in device QuickTurn Connection system promotes a fast, positive connection to the top of the appropriate cast-in device Dimension Adds 1" to all cast-in devices Pipe Sizes Addressed (See UL Systems) For 2" Water Module: 2" Pipe For 3" Water Module: 2.5" and 3" Pipe For 4" Water Module: 4" Pipe For 6" Water Module: 6" Pipe Red housing with black gasket Top Seal Plug A post-installed water barrier solution that impedes water Meets W-Rating requirements for select penetrants For use where a single penetrant is employed per cast-in device Chemically stable elastomeric material will not react with combustible pipes Applications For single penetrants placed through a 2" cast-in place device Iron Pipe Sizing (IPS) and Copper Pipe Sizing (CPS) offerings available For pipes ranging from nominal 0.5" to 2.0" in diameter Red (Pending) (Pending) Hilti Firestop Saving Lives through innovation and education Hilti. Outperform. Outlast. Hilti, Inc. (U.S.) 1-800-879-8000 www.us.hilti.com en español 1-800-879-5000 Hilti Firestop Systems Guide 2007