Proportional Amplifier

Similar documents
Multi-function Card. 1 Description. 2 Technical data ESSK General. 1.2 Application example

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Flow Control Valve. 1 Descriptions. 2 Symbols. Series SRCB Generals. 1.2 Application examples way flow control way flow control

Seat Valves. 1 Description. Series SVH Technical data. 1.2 Performance graphs

TECHNICAL DATASHEET #TD1000AX DUAL SOLENOID MULTIFUNCTION VALVE DRIVER With Joystick, Potentiometer and Control System Interface P/N: DSDA-SMB Series

Cable Plug acc. to DIN EN , Form A

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

3/2 Solenoid Cartridge Valve, Size 6

Ordering Part Numbers:

Option field bus: without bus with profibus DP. Design-Index (Subject to change)

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

W150: Miniature photoelectric switch series with completely integrated electronics

Electronic Pressure Switch EDS 300

3/2- and 2/2-way cartridge valve type BVE

RoHS. Shock / vibration resistant. Magnetic field proof. Many variants

Automatic Voltage Regulator User s Manual

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Electric Rotary Actuator - On/Off or programmable control actuator

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

W 36: Mastering complex tasks reliably

Mounting instructions. Junction box VKK2R-8 DIGITAL. A en

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

Model EC5111 Speed Controller Isochronous / Droop

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

"A" Series Variable Displacement Piston Pumps Single Pump, "OBE" Type Electro-Hydraulic Proportional Pressure & Flow Control Type

Electrical connection

Contactless Encoder RI360P0-QR24M0-INCRX2-H1181

is then retained absolutely without interruption.

Analog Servo Drive 25A8

VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS


HERZ-Thermal Actuators

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

Digital electronic drivers type E-RI-PES integral-to-valve format, for variable displacement axial piston pumps with alternate P/Q control

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

ELECTRONIC CONTROL UNITS. Machine Management Systems. Description. EC-MMS-1012-H 10 inputs, 12 outputs meter-in systems controller 20

4 Posiflow Proportional Solenoid Valves

SYSTEM 4C. C R H Electronics Design

Kit Watt Audio Amplifier

OPERATION MANUAL VALVE CHECKER G

Operating instructions Capacitive sensors

Safety automation solutions

Laser diffuse reflection light scanner with background suppression. Dimensioned drawing

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

Safety technique. Emergency stop module BO 5988 safemaster

Inductive sensor NI10-M18-Y1X-H1141

Proportional pressure regulators VPPE

Digital display DA 48

OPL BASIC. Dosing System for Professional Laundry machines. Contents

Doc.No. NDP 192U-02. Electric Pump Controller CE-124P. Instruction Manual

GAE953 Electrical Alarm Unit 19" with Indicator

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Photoelectric switches WLL 170(T), fibre-optic cables LL 3: flexible solutions with fibre-optic cable systems

WATER LEAK DETECTION SYSTEM WLDS-10 INSTALLATION & COMMISSIONING

ML 1012 v.1.2 ML13,8V/1A Buffer power supply module, linear.

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Temperature sensor with integrated transmitter for industrial applications, MBT 3560

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

DSE5J /112 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO (CETOP 05)

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Contents. Document information

MINI MCR-SL-R-UI(-SP)

Pressure transmitter For general industrial applications Model A-10

Digital inductive conductivity transmitter

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

DALI RC BASIC SO. Control unit Operating instructions

VEO. V4PF480Y/277VSYTK02 Art.Nr.: V4PF480Y/277VSYTK02P Art.Nr.: TECHNICAL DATA

CONSTANT CURRENT REGULATOR INDUPERM TYPE CCR 951. Standarddescription of CONSTANT CURRENT REGULATOR TYPE CCR 951.

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

LUT Luminescence scanners: Seeing what no-one else can

BITMAIN. APW PSU Series User Guide

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

mpm DIN CONNECTORS

Thyristor-controlled power supplies and battery chargers

User Manual for CH-PFC76810

Photovoltaic Solar Energy Unit EESFB

MasterINTERFACE 39 Series - Relay interface modules

Technical data. General specifications. Indicators/operating means. Electrical specifications Operating voltage U B Power consumption P 0 Interface

Electronic Pressure Switch EDS 3000

Joystick type EJ1-10, EJ2-10 and EJ with linear potentiometer and direction switches connection via with solderless lugs

Givare NC-SRS 280 och 880

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

Data Sheet. Electro-mechanical counters Hengstler 800 series

RADIANT PLASMA 4700 Plasma Spark Generator

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

FIREDEX Conventional Fire Panels

VOLUME AND TONE CONTROL - PREAMPLIFIER K8084

BOS 73K... BOS 74K...

intelligent solutions

WINGLIKE ELECTRONICS CO.,LTD

Quick Connect. quick - simple - efficient.

Technical Description. Transistor D.C. Chopper Controller Type GS 24 S

Transcription:

Proportional Amplifier ESSK 03 robust analogue technology Short-circuit protected Reference voltage for control signal generator Description. General The ESSK 03 proportional amplifier is used to control the solenoid of a hydraulic valve. The current compensation feature ensures that changes in the coil temperature or fluctuations in the supply voltage do not affect the coil current level. To provide for a trouble free hydraulic function, an optimum level of dither signal is superimposed on the coil current. The proportional amplifier requires a smoothed DC power supply in the range 2...30 V. The amplifier has an input for a voltage control signal. The control signal terminal has a high input impedance and - for safety reasons - the control signal source should always remain connected. An on-board voltage regulator generates a stabilised DC reference voltage. This can be used, among other purposes, to power the control signal source. The stabilised voltage and amplifier ground are both available at the card's edge connector. The current at the power output varies linearly with the voltage at the control signal input. With the aid of two trimming potentiometers, both minimum and maximum current values can be set. The adjustment range of the minimum current setting is influenced by the resistance of the control signal potentiometer.the amplifier switches off automatically for the duration of any short circuit at the load terminals. Within the amplifier, a quenching diode is connected in pa-rallel with the power output. This protects the output stage against switch-off spikes. It is therefore possible to use a standard connector plug at the solenoid. To avoid operational problems, the nominal voltage of the solenoid coil should be matched to the amplifier's power supply voltage..2 Models The card can be ordered with a 3-pin edge connector to DIN 67 or with screw terminals. For applications in high air humidity, or in equipment with high vibration levels, a fully encapsulated version is available..3 Application example Agricultural engineering Municipal equipment Forestry machines Construction equipment 2 Technical data General characteristics Description, value, unit Power supply 2 V... 30 V DC, smoothed. Ripple < 0% Reference voltage 5 V (is available for external use) max. output from reference voltage 0 ma Demand signal voltage 0 V... 5 V Minimum current (adjustable) (0...0,5) x I max (with 2,2 k control signal pot.) Maximum current (adjustable) (0...0,68) x I max (with k control signal pot.) Maximum permissible output current (I max ) 0,5 A... 2,5 A Reference: 00-P-70000-EN-07 Issue: 08.205 /6

General characteristics Dither frequency Enclosure protection Operating temperature table features Dimensions Mass Connections Cable length and section Description, value, unit factory set at 0 Hz (square wave from) (if required, can alternatively be set at 20 Hz IP 00 (non-encapsulated, without housing) - 20 C... + 50 C - the power supply input is reverse-polarity protected - the amplifier switches off automatically for the duration of excessive coil current (coil short circuit) approx. 00 x 98 x 20 mm approx. 80g non-encapsulated, 80 g encapsulated options: connector DIN 67-S3M or screw terminals for mm 2 section wire, max. cable length is 0 metres 3 Block diagram 2 V - 30 V DC power suply (2) 2V- 30V 5 V Short 0 V 5(6) Reverse polarity protection 3 () Control signal 3 Controller Dither 5 (6) Solenoid Adjustment Imin Adjustment Imax Current measurement Function and dimension 00 9 3,5 Trim Potentiometer, max. 20 turns + - P2 = maximum current (I max ) P = minimum current (I min ) 98 90 P2 0 30 20 30 P 6 6 7 7 3 90,5 + 0,5 Dimensions of the card with screw terminals or with edge connector 2/6

5 Connection diagram 3 30 29 28 27 26 25 2 23 22 2 20 9 8 7 6 5 3 2 0 9 8 7 6 5 3 2 6 5 3 2 6 5 3 2 Fuse 3A-5A fusible link Screen Solenoid (Hydraulic valve) +2V bis 30V 0 V power supply Potentiometer P IN max. to 2,2 k When the pin connector is used, the power supply and the solenoid loads must be connected using both pins. Use screened cable for all demand-signal lines. The screen must be bonded to the power-supply negative. 6 Initial start-up Connect the card in accordance with the connection diagram, using only with trim potentiometer. 7 Setup procedure I max P 2 I [A] 7. Set the potentiometer P IN to maximum. 8. Using trim potentiometer P2, and while increasing the signal, set the required maximum current (I max ) (the coil current must not exceed 2.5 A). 9. Set the potentiometer P IN to minimum. 0. Using trim potentiometer P, and while decreasing the signal, set the required minimum current (I min ).. Re-check the settings. I min P x V P IN (min) Potentiometer P IN 5 V P IN (max) U [V] P The trim potentiometers that are sealed with colour spots are preset in the factory. P2 Hydraulic opening range 3/6

8 Ordering codes E S S K 0 3-9 * * * / Electronic product Push-in card = S Proportional amplifier = SK Type Model with male edge connector (standard = 90 with screw terminals (standard) = 9 with screw terminals; side adjustment = 92 with male edge connector; side adjustment = 93 with male edge connector; encapsulated model (standard) = 80 with screw terminals; encapsulated model (standard) = 8 with screw terminals; side adjustment; encapsulated model = 82 with male edge connector; side adj.: encapsulated model = 83 Power supply 2...30 V DC = *** Variants / special features (inserted by the factory) Dither frequency of 20 Hz = 0 9 Accessories To house the amplifier, Bucher can provide an enclosure that accepts two PG9 cable glands. An On/Off switch for the amplifier is also available. To generate demand signals, a potentiometer can be supplied. As an alternative to the enclosure, a suitable card holder (for model ESSK 03-90 only) can be supplied, as can an appropriate snap-in retaining foot. Connector plugs, type GDM 309, can be used to connect to the solenoids. In the event of proportional valve malfunctions that are caused by long power leads, use connector plugs type GDM 209D. Description Order. no.: Potentiometer k 00.2662 Potentiometer 2,2 k 00.2663 Potentiometer scale knob 00.60397 On/Off switch 00.606576 Cable glandpg 9 00.60550 Retaining nut PG 9 00.6055 Plastic enclosure (0 x 88 x 60 mm) 00.289 Card holder 00.60620 Snap-in retaining foot 00.606202 Female connector, DIN 67, with solder terminals 00.6030 Connector plug GDM 309 00.06970 Connector plug GDM 209D 00.030 /6

0 Fault Finding hydraulic function Does supply voltage exist at terminals (2) and 6 (5)? Set control signal potentiometer to maximum. Is voltage at terminals 3 and 6 = 5 V? Check power supply and wires for polarity and continuity Solenoid current adjustable? Approx. 0.7 -.8 A for 2 V Approx. 0.3-0.9 A for 2 V Check hydraulic system, no current, max. current Clear the short circuit Is the reference voltage at terminals and 6 = 5 V? Disconnect demand-signal source from terminal. Is reference voltage available now? Card is faulty Demand-signal source is faulty, or line short circuit Ye s Break in solenoid leads, solenoid faulty Output voltage for solenoids at terminals 3 () and 5 (6) approx. 2 V or 2 V? Disconnect solenoid. Voltage available now? Short circuit in solenoid leads or solenoid. Check solenoid leads and solenoid for short circuit. Does short circuit exist? Card is faulty 5/6

info.kl@bucherhydraulics.com www.bucherhydraulics.com 205 by Bucher Hydraulics GmbH, D-7977 Klettgau All rights reserved. Data is provided for the purpose of product description only, and must not be construed as warranted characteristics in the legal sense. The information does not relieve users from the duty of conducting their own evaluations and tests. Because the products are subject to continual improvement, we reserve the right to amend the product specifications contained in this catalogue. Classification: 70.70.70 6/6