Strata Sleeve-It System

Similar documents
RETAINING WALL CONSTRUCTION DETAILS 2006 ESTIMATING AND INSTALLATION MANUAL. Featuring Highland Stone. anchorwall.com

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

CONCRETE SEGMENTAL RETAINING WALL SYSTEM

DESIGN GUIDELINES FOR EARTH RETENTION

COMMONLY USED RESIDENTIAL BUILDING CODES

General (1) This Section applies to the design and construction of interior and exterior stairs, steps, ramps, railings and guards.

Chapter 3 Pre-Installation, Foundations and Piers

The Verdura Wall check with your local building department

Residential Deck Safety, Construction, and Repair

Stabilenka HUESKER. and Separation. Engineering with Geosynthetics SKER HUESKER HUESKER HUESKER HUESKERHUES

Residential Decks. Planning and Development Services Department

SPECIFICATIONS FOR PRECAST MODULAR BLOCK RETAINING WALL SYSTEM (revised 11/5/13)

Ch a p t e r 5. Bridges Decks and Boardwalks

ATI Evaluation Service A Division of Architectural Testing Certification Services

Installation Guidelines for Segmental Block Wall. Contents 1. INTRODUCTION MATERIALS... 2

SKER HUESKER HUESKER geogrid HUESKER HUESKER for HUESKERHUES SKER HUESKER HUESKER HUESKERHUES SKER HUESKER HUESKER HUESKER HUESKER HUESKERHUES

Gas Meter Clearances and Service Installation Requirements


Unit Price Averages Reports

RESIDENTIAL WOOD DECKS

Building Your Interlocking Concrete Pavement to Last a Lifetime

SWIMMING POOL, SPA, & HOT TUB GUIDELINES

Safe & Sound Bridge Terminology

I N T E R N A T I O N A L R E S I D E N T I A L CO D E

EXCAVATION AND PILING NEAR SEWERS, STORMWATER DRAINS AND WATER MAINS

The Most Advanced Name in Drainage Systems. Geotextile Products

TOWNSHIP OF TOMS RIVER ZONING OFFICE DECK CONSTRUCTION

Gas Meter Clearances and Service Installation Requirements

SCHEMATIC AND PROJECT BUDGET APPROVAL EAST CAMPUS NURSING EDUCATION AND CLASSROOM

FY11 Sanitary Sewer Main Rehab and Point Repair Bid Tabulation

SECTION PUBLIC STORM UTILITY DRAINAGE PIPING

Number of Sides Required to Have a Handrail

rhuesker HUESKER HUESKER HUESKER HUESKER HUESKERr HUESKER HUESKER HUESKER HUESKERHUES Product- Portfolio HUESKER Engineering with Geosynthetics

Emergency Spillways (Sediment basins)

Civil. 2. City of Seattle Supplement to the Specification for Road, Bridge and Municipal Construction, most current addition.

This handout is a guide only and does not contain all of the requirements of the Minnesota State Building Code or city ordinances.

Florida Building Code 2004 SECTION 1009 STAIRWAYS AND HANDRAILS

Outlet stabilization structure

MAJOR 2015 MN RESIDENTIAL CODE CHANGES Effective Date: January 24 th, 2015

Architectural Processing and Inspections for Home Mortgage Insurance

Mechanically stabilized layers in road construction

ROAD CONSTRUCTION. Pavement Base Reinforcement Subgrade Stabilization

SECTION CONCRETE SEGMENTAL RETAINING WALL SYSTEM

Certification: Building Plans Examiner. Exam ID: B3

FY08 SEWER POINT REPAIRS BID TABULATION

1. ASTM C Sampling and Testing Concrete Masonry Units 2. ASTM C 1372 Standard Specification for Dry-Cast Segmental Retaining Wall Units

SECTION CONCRETE SEGMENTAL RETAINING WALL SYSTEM

The replacement or modification of existing windows shall comply with the following requirements:

3. Amend the following: Item 410 Traffic Compacted Surface, Type C to Item 446 Cold Patch.

STRUCTURES Excavation and backfill for structures should conform to the topic EXCAVATION AND BACKFILL.

CITY OF VAUGHAN SCHEDULE O LOT GRADING DESIGN FOR RESIDENTIAL DEVELOPMENT

Sewage Compliance Form Instructions

SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION

Specification Guidelines: Allan Block Modular Retaining Wall Systems

Mobile Home Pre-Inspection Checklist

Fire-Retardant-Treated (FRT) Plywood

OPTIONAL INFORMATION GUARDING FLOORS, STAIRS, AND OTHER OPENINGS SELF INSPECTION CHECKLIST

Engineered, Time-Tested Foundation Repairs for Settlement in Residential and Light Commercial Structures. The Leading Edge.

Storm Drain Inlet Protection - IP

Ohio Department of Transportation Division of Production Management Office of Geotechnical Engineering. Geotechnical Bulletin PLAN SUBGRADES

CHAPTER 7: Building Systems ROOFING SYSTEMS

Specifications for Residential Property Owners Connection to New Public Sewer

Minimizes sediment and debris from entering storm drains that lead to waterways and watercourses.

Permeable Pavement Construction Guide

SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)

Stormwater/Wetland Pond Construction Inspection Checklist

STANDARD AND SPECIFICATIONS FOR STORM DRAIN INLET PROTECTION

AZEK Rail Install Guide

SCOPE This guideline applies to all construction projects on Emory University properties, including renovation projects.

Introduction to Minimal Excavation Foundations

BUILDING PERMIT SPECIFICATIONS

MAYOR S OFFICE OF TRANSPORTATION AND UTILITIES D E P U T Y M A Y O R R I N A C U T L E R

MOBILE HOME LAW. Revised November 2001

Lighthouse Engineering, L.L.C.

SECTION REMOVAL OR ABANDONMENT OF EXISTING UTILITIES AND UNDERGROUND STRUCTURES. 1. Trench excavation, backfill, and compaction; Section

How To Retaining Wall Guide

What you need to know about concrete block basement construction.

CHAPTER 8 CIVIL DESIGN

Vehicle Tracking Pad

Section 2100-Trenching and Tunneling

COMMONWEALTH OF KENTUCKY CITY OF LONDON ORDINANCE NO AN ORDINANCE ESTABLISHING EROSION AND STORM WATER CONTROL

TABLE OF CONTENTS. Manhole, Frame, and Cover Installation (includes Drop Manhole) Additional Manhole Depth

City of Shelbyville Site Inspection Checklist

CITY OF TORONTO. BY-LAW No

R E S I D E N T I A L H O U S I N G

Structural Foundation System

DRAFT TERMITE PROTECTION IN BUILDINGS

MANUFACTURED HOME INSTALLATION FOR PERMANENT FOUNDATIONS (TRANSVERSE FLOORS) (SUPPLEMENT TO MANUFACTURED HOME INSTALLATION MANUAL)

Helen Mercury Mine EE/CA OPINION OF PROBABLE COST

Site Development Information Worksheet for single family residential development

GYPSUM AREA SEPARATION FIREWALLS GA

Mandatory Part 1.4 BUILD OVER OR NEAR SEWERS, STORMWATER DRAINS AND WATER MAINS

Value of Instrumentation Systems and Real-Time Monitoring: An Owner s Perspective

Sealant. 30" Model No D: 17-7/8" TO 18-3/8" (454 to 466mm) W: 29-3/4" TO 30-1/4" (756 to 768mm) Under Countertop Installation

Designed and Engineered to Perform

Uncovered Decks & Porches

Drew University Ladder Safety Program Policy and Inspection Procedure Draft 0412

WINDOW AND DOOR REPLACEMENT REQUIREMENTS

The unit costs are based on the trend line of the 3 low bids for the average quantity.

Exterior Elevated Elements Inspection Guidelines

Transcription:

Strata Sleeve-It System Pre-Engineered Fencing Solutions When Your Wall Needs a Fence

Project DHL Distribution Facility Allentown, PA Product Over 350 Sleeve-It 1224R units used Savings 10,000 square feet of real estate FRONT SLEEVE HALF LID Simple Construction REAR SLEEVE HALF PVC COATED STRUTS Step 1 Install the cantilevered Sleeve-It units near the elevation of the top of wall Step 2 Fill and compact soil up to the top of the sleeve UPRIGHT LEG 12 0 PVC COATED CANTILEVER BASE Isometric View of Sleeve-It 1224R System Components Step 3 Leave the disposable lid on the sleeve until the fence installer places the fence post in the sleeve and fills with concrete Step 4 The fencing contractor finishes the fence, supported by the buried Sleeve-It System.

Maximizing Land Use Retaining wall solutions that start with Stratagrid high tenacity geosynthetic reinforcement receive their finishing touches from the Sleeve-It System. The patented Sleeve-It System (rail integration device) is a code compliant, fence-post anchoring system that integrates stable fence footings into the support structure of retaining walls, while the retaining wall is being constructed. Don t wait until the retaining wall is built to consider fence requirements. As a pre-engineered/pre-designed system, Sleeve-It is a proven fence post integration device designed to reduce specifier liability and associated costs with building-code compliance. Using the system as part of the SRW eliminates a 3 foot offset requirement for rails/fences that are added after wall construction. Sleeve-It offers a below grade engineered design that provides superior safety in a cost effective solution. With Sleeve-it FENCE POST RETAINING WALL BLOCK 50PLF LOAD PER IBC/IRC RESISTING SOIL MASS 12 ØX24 DEEP SLEEVE-IT Without Sleeve-it FENCE POST RETAINING WALL BLOCK 50PLF LOAD PER IBC/IRC SONOTUBE OR PIPE SLEEVE

Building Codes Both residential and commercial building codes specifically state safety rails shall be provided when the vertical grade between different surfaces exceed a fixed vertical height. Commercial codes further define minimum load requirements that the guards are to provide. Building codes generally require guards (protection) atop retaining wall structures and are applicable to fencing and pedestrian rail systems placed atop segmental retaining wall systems. Residential Codes The International Residential Code (IRC) states, Section R312 - Guards, states guards are required when raised surfaces are located more than 30 inches above the floor or grade below. The guard shall not be less than 36 inches (3 feet) in height. The requirement for guards applies to porches, balconies, decks, ramps and raised surfaces (i.e. retaining walls). Commercial Codes The International Building Code (IBC), Section 1013 Guards, states guards shall be located along open-sided walking surfaces, mezzanines, industrial equipment platforms, stairways, ramps and landings that are located more than 30 inches above the floor or grade below. The guard shall provide adequate strength to meet the load requirements of Section 1607.7. Section 1607.7.1 requires guards and handrails to resist a load of 50 pounds per linear foot applied along the top, and Section 1607.7.1.1 states the assemblies and guards shall be able to resist a single concentrated load of 200 pounds applied along the top. Sleeve-It Testing Rutgers University in coorperation of SLEEVE-IT 1224R FENCE FOUNDATION SYSTEM (INSTALL PER SLEEVE-IT INSTALLATION GUIDE) CAP UNIT (TYP.) *FENCE POST (BY OTHERS) PERMANENT VEGETATION (TYP.) EROSION CONTROL BLANKET TOP SOIL (TYP.) SRW UNIT (TYP.) IMPERMEABLE SOIL LAYER (6-INCH (150mm) MIN.) RETAINED FILL 0.5' (150mm) (MIN.) REINFORCED FILL EXISTING GRADE 0.5' (150mm) (MIN.) DRAINAGE FILL 3/4-INCH (19mm) CRUSHED ROCK OR STONE (MAXIMUM 5% FINES) DRAINAGE FILL 2-INCH (305mm) MIN. BEHIND WALL UNIT STRATAGRID (TYP.), SEE PROFILE FOR TYPE, ELEVATION AND LENGTH NON-WOVEN GEOTEXTILE (TYP.) RETAINED SOIL

Additional Solutions from Strata StrataWall and StrataSlope systems provide designers and engineers with an array of options for building retaining walls, vegetated steep slopes, temporary walls, and embankments. Not only are Strata products easy to handle and simple to install, they re built to last. But Strata doesn t just manufacture the industry s highest quality geogrid products. Our dedicated engineering staff adds value to each soil reinforced system with a comprehensive program of world-class technical support. Strata s superior customer service begins with the design and bidding process, continues through ongoing consultations, and extends to expert installation training and other on-site assistance. Stratagrid The industry s first geogrid material knitted from high molecular weight and high tenacity polyester yarn. Engineered strength to comply with your geogrid application no matter how big the job. Microgrid A small aperture geosynthetic specially developed for face wrap applications StrataTex WOVEN and NON-WOVEN Geotextiles for separation and reinforcement StrataBase A rigid biaxial geogrid that provides structural reinforcement for paved and unpaved roads StrataDrain High-flow, fusion-bonded, geonet-geotextile composites for improved soil drainage

Consider Sleeve-It Fencing Integration System The Undeniable Benefits of the Sleeve-It System 1.800.680.7750 380 Dahlonega Road, Suite 200, Cumming, GA 30040 USA CERTIFICATION ISO 9001 WARRANTIES ON GOODS. Strata Systems represents that all goods manufactured by Strata Systems will be free from defects in material or workmanship for a period of one (1) year from date of shipment. STRATA SYSTEMS MAKES NO OTHER WARRANTY, EXPRESS OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAMIED. All projects which incorporate the use of Strata products should be desinged by a competent professional engineer.