Electronic Thermostats

Similar documents
Owner s Manual. Model 8476 Thermostat with Event-Based Air Cleaning. Includes Operating Instructions and Warranty Information

Owner s Manual Model 5000 Safety, Operating and Maintenance Instructions

1 For All Non-Programmable Digital Thermostat

TC --- PHP, TC --- PAC Comfort Series Programmable Thermostat. Owner s Manual

Operating Manual. Prestige THX9000 Touch-screen Thermostat Thermostat à écran tactile Termostato con pantalla táctil

Carrier Thermostat Quick Reference Guide

EK908FHL - Thermostat for floor heating

ACONT900AC43UA Communicating, Programmable Comfort Control

HEAT PUMP PROGRAMMABLE THERMOSTAT

Operation Guide 3M-22

Owner s Guide Guide du propriétaire Guía para el usuario TH115-AF-GB-10. Programmable thermostat Thermostat programmable Termostato programable

Blue Easy Reader Thermostat 1F95EZ Homeowner s Guide

Ultraviolet Germicidal Lamps Owner s Manual MODELS 1910 & 1930

Sensi TM. Wi-Fi Programmable Thermostat MANUAL OPERATION. Version: March Emerson Electric Co. All rights reserved.

Mode Switch. Fan Switch Menu button Program button

UP400 Programmable Thermostat Installation Instructions & User Guide. For Installation Help. White-Rodgers.com

HEAT HEAT COOL HEAT PUMP COOL

TABLE 1: Wiring Terminals. Connect to... 1C 1H 2C 2H 1H1C 2H1C 2H2C 3H2C

Operation 8022C. Customer Support: or Visit our webiste Made In China OFF FAN HEAT COOL AUTO ON

Model 800 Residential Steam Humidifier Owner s Manual. Includes Safety & Operating Instructions and Warranty Information

ADEMCO 4500 Thermostat

Programmable Thermostat MODEL XXX With Dehumidify XXX With Out Dehumidify

NOTE: Append this Operation IB to the Install IB to make one IB-booklet. Need a divider tab between the 2 sections. Blank page remove.

Wireless 7 Day Programmable Room Thermostat

CT3200 Programmable Thermostat

T8131C, T8132C Programmable Thermostat

APPLICATIONS SPECIFICATIONS CAUTION. Blue Universal Thermostat with Automatic Heat/Cool Changeover Option. Save these instructions for future use!

Installation Guide. VisionPRO. TH8000 Series. Need Help? This manual covers the following models. System Types

AN500T, AN1000, AN1000T, AN1500, AN1500T AN2000, AN2000T

Sonic Boom Travel & Bed side Alarm Clock with Bed Shaker Model SB200ss-v3

Honeywell CT3500/CT3595 PROGRAMMABLE THERMOSTAT

1F /1/1 Day Programmable. 1F Thermostat Thermostat Configuration Options Heat Pump. Maximum Stages Heat/Cool 2/1

Drayton Digistat +2RF

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Energy Saving Tips. Adjust set point temperature up a few degrees... Window contact. Occupancy sensor. A Programmable Thermostat

Ultrasonic Jewelry/DVD Cleaner. make jewelry, dvds and more sparkle like new

Single Zone LCD Thermostat Operating Instructions

Mold Alert... Operation Manual P0270

Sensi TM. Wi-Fi Programmable Thermostat SCHEDULING GUIDE. Version: March Emerson Electric Co. All rights reserved.

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

Installation Instructions

PR-2500 Portable Receiver. Owner s Manual

RCS-TM80BG. Contents 4. Weekly Program Function... EG-6 5. Outing Function... EG Sleeping Function... EG-14 XXX XXXX XXXX XXXX XXXX

GETTING STARTED WITH THE MIPOWER MANAGEMENT SYSTEM

AM/FM PLL Clock/Table Radio

Owner s Guide. ca6554

its ELECTRIC POSITION for electric heat, or set the units fan control appropriately to ELECTRIC or another appropriate setting.

INSTALLATION AND OPERATING INSTRUCTIONS

INSTALLER S & OWNER S MANUAL

Model SBB500SS-v3. Sonic Boom Alarm Clock & Bed Shaker OPERATION INSTRUCTIONS

USER MANUAL WARNING! CONTENTS MODEL 1 SPECIFICATIONS READ ALL INSTRUCTIONS BEFORE PROCEEDING. Non-Programmable Single Stage Heat/Cool Thermostat

SINCE AUTO SAVER 550. OwnerÕs Manual Model 44550

YOUR THERMOSTAT REPLACES Assemble tools required as shown below. HAND OR POWER DRILL WITH 3/16 INCH DRILL BIT, IF NEEDED

e I N S T RUC TION M ANU A L

Acrylic Walls Installation Instructions

LCD5500Z / PKP-LCD v3.x Installation Instructions

PSPA711a. LUXPRO PSPA711a INSTALLATION AND OPERATING INSTRUCTIONS. Mt. Laurel, New Jersey 08054, USA

User Manual THR840DUK Digital Thermostat

Table of Contents Function Keys of Your RF Remote Control Quick Setup Guide Advanced Features Setup Troubleshooting

Please read this owner s Manual carefully before operating the unit. - Cooling - Heating - Dehumidifying - Fan

TRANSMITTER RECEIVER THESE INSTRUCTIONS APPLY IN THE UK ONLY THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER OR AT THE APPLIANCE. Digistat Optimiser

VIBRATION WATCH with: Vibration Alarm (won't disturb others). Beep Alarm (optional) Electro-Luminescent (EL) back light (for viewing display at

Alarm Clock USER GUIDE

DC REFRIGERATORS 12/24 VOLTS INSTALLATION AND OWNER S MANUAL

Intelli-Time Alarm Clock model 13027

Fused Spur Time Switch

Installation Guide. Programmable Thermostat TH6220D

COMPUTHERM Q7 Programmable, digital room thermostat. Operating Instructions

EVAPORATIVE AIR COOLER INSTRUCTION MANUAL

Instruction manual for Firstline FCS12000CH

QUICK INSTALLATION GUIDE

MAP COFFEE MIA CAPSULE COFFEE MACHINE INSTRUCTION MANUAL MODEL: CM4725. Read this manual thoroughly before using and save it for future reference

Atomic Alarm Clock model 13131W2

Laser Wireless Rechargeable Mouse. User s Manual

User Guide ecobee ecobee 250 University Ave Suite 400 Toronto Ontario M5H 3E5 Canada Toll free

Portable Air Conditioner

VIBRATION WATCH with:

AIR CONDITIONER REMOTE CONTROLLER ILLUSTRATION CS457-R14A

1F Programmable Electronic Digital Heat Pump Thermostat INSTALLATION AND OPERATION INSTRUCTIONS

LCD BacPac. User Manual + Warranty Info

UV100E Ultraviolet System

Atomic Projection Alarm Clock model 13021

MAINTENANCE & TROUBLESHOOTING

Name of Equipment Silver King Model SKMCD1P/C1. This equipment chapter is to be inserted in the appropriate section of the Equipment Manual.

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

How To Control A Thermostat

Owner s Manual. Walk-in Monitoring System 100. Cooler is Better! TM. Used in UL Listed Door Panel Assemblies

Installation Instructions

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Use & Care. of your Iron. All about the TA B L E O F C O N T E N T S. USA and Canada

Attached is a link to student educational curriculum on plug load that provides additional information and an example of how to estimate plug load:

Savant Systems LLC Technical Application Note How to Guide: HVAC Scheduling Setup

Thermometer model 00754

3 WATT LED SPOTLIGHT Model No. SLM

USER MANUAL. Bottom Loading Bottled Water Dispenser SAVE THIS MANUAL FOR FUTURE USE. Model #

What you can expect from your Solar Hot Water System

Temperature Humidity Meter

UNIFIED FACILITIES GUIDE SPECIFICATIONS

Transcription:

Electronic Thermostats MODEL 8344 HEAT/COOL NON-PROGRAMMABLE MODEL 8346 HEAT PUMP NON-PROGRAMMABLE MODEL 8348 HEAT/COOL MULTI-STAGE NON-PROGRAMMABLE MODEL 8363 HEAT/COOL 5/2 DAY PROGRAMMABLE MODEL 8365 HEAT PUMP 5/2 DAY PROGRAMMABLE MODEL 8366 HEAT/COOL MULTI-STAGE 5/2 DAY PROGRAMMABLE Operating Instructions READ AND SAVE THESE INSTRUCTIONS

TABLE OF CONTENTS PRODUCT FEATURES..................................................2 GETTING FAMILIAR WITH YOUR APRILAIRE THERMOSTAT...............3 OPERATING INSTRUCTIONS...........................................4 Operating Modes................................................4 Temporarily Raise and Lower Temperature.........................4 Fan Operation....................................................5 Programming Your Thermostat (Programmable Models Only)........5 Set Current Time and Day.....................................5 Program for Heating and Cooling..............................5 Program Events..............................................6 To Change the Heating Program...............................7 To Change the Cooling Program...............................7 Hold Temperature/Vacation (Programmable Models Only)...........7 Battery Replacement.............................................8 Cleaning the Thermostat..........................................9 SET UP INSTRUCTIONS...............................................9 To Clear the Change Water Panel or Change Filter Indicator.....9 To Change F to C...............................................9 To Change Differential Setting....................................10 To Change Temperature Offset...................................11 To Change the Water Panel Indicator Setting......................12 To Set Humidifier Type...........................................12 To Change the Air Filter Indicator Setting..........................13 To Set Number of Weekend Events (Programmable Models Only)...14 LIMITED WARRANTY................................................15 1

PRODUCT FEATURES Large, easy to read, backlit display. Simple programming with 4 events for weekdays and selectable 2 or 4 events on the weekend. Pre-programmed with ENERGYSTAR recommended settings. Set point and room temperature are displayed simultaneously. Freeze protection. Low battery indicator. High temperature protection (Models 8344, 8348, 8363 and 8366). Temporary and permanent (vacation) hold. Change Water Panel indicator. Change air filter indicator. Fahrenheit/Celsius selectable. Adjustable differential. Adjustable offset. ENERGYSTAR PROGRAM INFORMATION (Programmable Models Only) About half of all energy used by households goes to heating and cooling the home. If you ve selected a programmable Aprilaire Electronic Thermostat, you have made a significant step toward conserving energy usage and costs, while improving your indoor comfort. In fact, the Aprilaire Electronic Thermostat Models 8363, 8365 & 8366 have earned the ENERGYSTAR designation of the U. S. Environmental Protection Agency (EPA). This means that your Aprilaire Thermostat is a highly efficient, cutting edge product that is good for the environment. It saves energy and costs less to operate than similar products that do not qualify for the ENERGYSTAR label. ENERGYSTAR products help you differentiate between standard efficiency and high efficiency products. By using ENERGYSTAR products, you are helping to prevent air pollution while saving money on your utility bills. According to the EPA, taking advantage of the times that a home is unoccupied or the occupants are asleep, an ENERGYSTAR thermostat can reduce heating and cooling bills by as much as 30%. The Aprilaire Thermostat has programmable capabilities that allow you full flexibility to set your heating and cooling systems to meet your comfort and energy needs. As an ENERGYSTAR partner, Aprilaire has determined that this product meets the ENERGYSTAR guidelines for energy efficiency. 2

GETTING FAMILIAR WITH YOUR APRILAIRE THERMOSTAT See Figure 1 for a description of the thermostat and controls. Figure 1 Auxiliary Heat Light (Models 8346 & 8365 only) Check Equipment Light (Models 8346 & 8365 only) PROGRAMMABLE MODELS ONLY Large, Backlit Display Set Time Hour, AM/PM, Minute, Day Events Temperature and Time Use to change time and temperature values when programming or setting the time of day. Use to raise or lower the heating or cooling set point in normal operation. AUX CURRENT TIME [Advance Time] PROGRAM [Advance Program] CHECK Activates Back Light WAKE F CHANGE FILTER LEAVE WATER PANEL RETURN C LOW BATTERY SLEEP HOLD OVERRIDE ROOM DONE SET AM E-HEAT PM COOL MO TU WE TH FR SA SU FAN Auto On HOLD [Resume] MODE Cool Off Heat E-Heat Press to Hold temperature. Press again to Resume program Mode Switch Cool, Off, Heat, E-Heat (Emergency Heat for Models 8346 & 8365 only) Fan Switch Auto operates the fan with heating and cooling equipment. On operates the fan continuously. See Figure 2 for the display. Figure 2 Event Temporary Override Current Time Current Room Temperature Fahrenheit or Celsius Program Done WAKE F LEAVE RETURN C SLEEP OVERRIDE ROOM DONE SET AM E-HEAT PM COOL MO TU WE TH FR SA SU Day of Week PROGRAMMABLE MODELS ONLY CHANGE FILTER WATER PANEL LOW BATTERY HOLD Change Filter Indicator Change Water Panel Indicator Change Battery Indicator Hold Temperature Current Temperature Setting Cool, Heat, E-Heat (Emergency Heat Models 8346 & 8365 only) 3

OPERATING MODES OPERATING INSTRUCTIONS Your thermostat has three operating modes, COOL, OFF and HEAT. Heat pump Models 8346 & 8365 have an additional EMERGENCY HEAT mode (E-HEAT on display). COOL HEAT In the COOL mode, the thermostat will control the cooling system and maintain your cooling set point. NOTE: There is a 4-minute delay after a cooling call is completed. This is to protect the equipment s compressor from short cycling. OFF In the OFF mode, the thermostat will not operate the heating or cooling equipment. The FAN switch can be placed in the ON position to operate the fan continuously. CAUTION: Do not set to OFF mode during periods when freezing temperatures may occur. In HEAT mode, the thermostat will control the heating system. NOTE: There is a 4-minute delay after a heating call is completed on heat pump models 8346 & 8365. This is to protect the equipment s compressor from short cycling. E-HEAT (MODELS 8346 & 8365 ONLY) In E-HEAT mode, the thermostat will activate the emergency heat with any heat call. (Note-the AUX light in the upper left hand corner of the thermostat will illuminate any time there is a call for Emergency Heat or Auxiliary Heat. ) TEMPORARILY RAISE AND LOWER TEMPERATURE MODELS 8344, 8346 & 8348 1. Press to the temperature. TEMPORARILY RAISE AND LOWER TEMPERATURE MODELS 8363, 8365 & 8366 1. Press to the temperature. The OVERRIDE icon will appear. The new temperature setting will hold until the next programmed event. 2. Press HOLD twice to resume program. 4

FAN OPERATION The thermostat has two settings for fan operation, AUTO and ON. AUTO In the AUTO setting, the fan operates only when the heating or cooling equipment is on. PROGRAMMING YOUR THERMOSTAT MODELS 8363, 8365 & 8366 SET CURRENT TIME AND DAY 1. Press CURRENT TIME and use the to the current hour. IMPORTANT: HOUR TO APPROPRIATE AM/PM SETTING. NOTE: The flashing information is being adjusted. 2. Press CURRENT TIME again to advance to and the current minutes. 3. Press CURRENT TIME again to advance to and the current day. 4. Press CURRENT TIME again to finish. DONE will appear on the display when you have completed setting the time and day. PROGRAM FOR HEATING AND COOLING As part of the ENERGYSTAR program, your thermostat has been pre-programmed with the following times and temperatures, which can be modified as desired (see page 7). 5 ENERGYSTAR SETTINGS ON In the ON setting, the fan will operate continuously. Event Temperature Time Schedule Setting Weekday Weekend Wake Heat = 70 F 6:00 AM 6:00 AM Cool = 78 F Leave Heat = 62 F 8:00 AM 8:00 AM Cool = 85 F Return Heat = 70 F 5:00 PM 5:00 PM Cool = 78 F Sleep Heat = 62 F 10:00 PM 10:00 PM Cool = 82 F

PROGRAM EVENTS Your thermostat has 5/2 (5 weekdays and 2 weekend days) programming functionality, which allows the user to set four events for the weekdays (Monday through Friday) and two or four events for the weekend (Saturday and Sunday). The events are WAKE, LEAVE, RETURN and SLEEP. If you are normally home on the weekend, you can set up your thermostat to use only 2 events (WAKE and SLEEP) on Saturday and Sunday. WAKE is the time and temperature setting you desire when you wake in the morning. The event should include extra time for the heating and cooling equipment to heat or cool the house to a comfort level prior to getting out of bed. NOTE: It will take some time for your heating or cooling system to reach the desired temperature when returning from setback. Therefore, it is suggested you set your program time before the actual time you want your home to reach the desired temperature. For example, if you get up at 7:00 AM and have a 6 degree setback, set your WAKE event to 6:00 AM to be sure the desired temperature is reached by 7:00 AM. LEAVE is the time and temperature setting for the daytime hours you are away from the house and wish to reduce the heating or increase the cooling temperature for energy savings. RETURN is the time and temperature setting for the evening hours. SLEEP is the time and temperature setting for your sleep hours. 6

TO CHANGE THE HEATING PROGRAM WAKE WEEKDAY 1. Move the MODE switch to the HEAT position. 2. Press the PROGRAM button and then to the weekday WAKE time. 3. Press the PROGRAM button again to advance to and adjust the WAKE temperature. LEAVE WEEKDAY 4. Press the PROGRAM button and then to the weekday LEAVE time. 5. Press the PROGRAM button again to advance to and adjust the LEAVE temperature. RETURN WEEKDAY 6. Press the PROGRAM button and then to the weekday RETURN time. 7. Press the PROGRAM button again to advance to and adjust the RETURN temperature. SLEEP WEEKDAY 8. Press the PROGRAM button and then to the weekday SLEEP time. 9. Press the PROGRAM button again to advance to and adjust the SLEEP temperature. WEEKEND 2 or 4 Events (See page 14) 10. Repeat the weekday steps for the weekend events. 11. Press PROGRAM again to exit programming. DONE will appear on the display. TO CHANGE THE COOLING PROGRAM 1. Move the MODE switch to the COOL position. 2. Repeat the steps above to Program for cooling. HOLD TEMPERATURE / VACATION MODELS 8363, 8365 & 8366 When the thermostat is in HOLD the set point will be maintained until the HOLD/Resume button is pressed. 1. Press the HOLD button. The HOLD icon will appear on the display and the time and day will disappear. 2. Press the to the temperature. 3. Pressing HOLD again will resume program. 7

BATTERY REPLACEMENT NOTE: New batteries must be replaced within one minute after removal of old batteries. If more than one minute elapses the programmed settings will be lost and revert to the factory settings. See Figures 3 and 4 for cover removal and battery orientation. Replace batteries once per year or when LOW BATTERY appears on the display. This will keep the thermostat working properly. Replace with two new AA alkaline batteries. 1. Move FAN switch to AUTO setting. 2. Move MODE switch to OFF position. 3. Remove housing by gently pulling the housing from the base. See Figure 3. 4. Insert new batteries as shown. 5. Replace housing. 6. Return FAN and MODE switch to desired position. 7. Check to see the correct time and day appear on the display. If more than one minute has elapsed, the thermostat will require re-programming. Figure 3 Cover Removal Figure 4 Battery Orientation - + - + Pull Here to Open AA Alkaline Battery 8

CLEANING THE THERMOSTAT If the surface of the thermostat becomes dirty it can be cleaned with plain water or a non-abrasive household cleaner including glass cleaner. When using any cleaner, be careful not to get any into the interior of the thermostat. Do not spray any liquid directly onto the thermostat. Spray the cleaner on to a soft cloth and wipe the surface of the thermostat. SET UP INSTRUCTIONS TO CLEAR THE CHANGE WATER PANEL OR CHANGE FILTER INDICATOR Your thermostat is equipped with indicators on the display to notify you when it is necessary to change the systems filter and humidifier Water Panel. 1. Place the MODE switch in the OFF mode. 2. Push and hold both of the temperature buttons simultaneously ( and ) until the alert clears from the display. 3. Thermostat will clear the change Water Panel or change air filter indicator. MODE Cool Off Heat Press and Hold Simultaneously for Three (3) Seconds TO CHANGE F TO C The Aprilaire Thermostat is capable of displaying temperatures in Fahrenheit or Celsius. 1. Place the MODE switch in the OFF mode. 2. Push and hold both of the temperature buttons simultaneously ( and ) until ROOM and OFF are no longer displayed. MODE Cool Off Heat Press and Hold Simultaneously for Three (3) Seconds 9

3. Display will show only the room temperature and scale. Use the or button to toggle between Fahrenheit (F) or Celsius (C). 4. Press the button repeatedly until DONE is displayed. F C TO CHANGE DIFFERENTIAL SETTING (d1) The Aprilaire Thermostat is capable of adjusting the differential to change how often the heating and cooling equipment will cycle on and off. 1. Place the MODE switch in the OFF mode. 2. Push and hold both of the temperature buttons simultaneously ( and ) until ROOM and OFF are no longer displayed. 3. Press the button until d1 is displayed. MODE Press and Hold Simultaneously Cool Off Heat 4. Thermostat will display d1 and a number 1, 2 or 3. The number indicates the degrees from setpoint before a call for heating or cooling is made. 5. Use the buttons to select 1, 2 or 3 degrees. 6. Press the button repeatedly until DONE is displayed. OR TO CHANGE SECOND STAGE DIFFERENTIAL SETTING (d2) (MODELS 8348 & 8366 ONLY) This setting controls how far from the first stage differential setting the temperature will be allowed to fall/rise before initiating second stage. 10

1. Place the MODE switch in the OFF mode. 2. Push and hold both of the temperature buttons simultaneously ( and ) until ROOM and OFF are no longer displayed. 3. Press the button until d2 is displayed. MODE Press and Hold Simultaneously Cool Off Heat 4. Thermostat will display d2 and a number 1, 2 or 3. The number indicates the degrees from the first stage differential setting (d1) before a call for heating or cooling is made. 5. Use the buttons to select 1, 2 or 3 degrees. 6. Press the button repeatedly until DONE is displayed. OR TO CHANGE TEMPERATURE OFFSET Aprilaire thermostats are factory tested and calibrated within 1 Fahrenheit. However, it may be desirable to adjust the reading of the thermostat to coincide with other temperature measuring devices. 1. Place the MODE switch in the OFF mode. 2. Push and hold both of the temperature buttons simultaneously ( and ) until ROOM and OFF are no longer displayed. 3. Press the button until OF is displayed. MODE Cool Off Heat Press and Hold Simultaneously for Three (3) Seconds 4. Press the and buttons to raise or lower the displayed temperature. The thermostat will indicate the number of degrees above or below actual temperature of adjustment. 11

5. Press the button repeatedly until DONE is displayed. OR TO CHANGE THE WATER PANEL INDICATOR SETTING The Aprilaire Thermostat is capable of indicating when the Water Panel of a humidifier should be changed. 1. Place the MODE switch in the OFF mode. 2. Push and hold both of the temperature buttons simultaneously ( and ) until ROOM and OFF are no longer displayed. 3. Press the button several times until CHANGE WATER PANEL is displayed on the thermostat. MODE Cool Off Heat Press and Hold Simultaneously for Three (3) Seconds 4. Use the and buttons to select between 1 to 12 or OFF. This is the number of months until the CHANGE WATER PANEL reminder will first be displayed. Subsequently, it will be displayed every 52 weeks. 5. Press the button repeatedly until DONE is displayed. CHANGE WATER PANEL CHANGE WATER PANEL TO SET HUMIDIFIER TYPE NOTE: This feature will only be displayed if the Water Panel Change value is not set to OFF. 1. Place the MODE switch in the OFF mode. 2. Push and hold both of the temperature buttons simultaneously ( and ) until ROOM and OFF are no longer displayed. 12

3. Press the button several times until WATER PANEL is displayed on the thermostat. 4. Use the or button to set this value to 1 if the home has an Aprilaire Model 400 whole house humidifier. The Water Panel in the Model 400 should be changed twice per season and this feature will cause the Water Panel Change Alert to appear on the display 90 days after the first alert. For example, if the Water Panel Change Alert value is set to show the first alert in October, then a second alert will appear in January. An alert will not be displayed again until the next October, and the cycle repeats. 5. Press the button repeatedly, after the humidifier type value has been set, until DONE is displayed. WATER PANEL WATER PANEL TO CHANGE THE AIR FILTER INDICATOR SETTING The Aprilaire Thermostat is capable of indicating when the air filter should be changed. 1. Place the MODE switch in the OFF mode. 2. Push and hold both of the temperature buttons simultaneously ( and ) until ROOM and OFF are no longer displayed. 3. Press the button several times until CHANGE FILTER is displayed on the thermostat. MODE Cool Off Heat Press and Hold Simultaneously for Three (3) Seconds 4. Use the and buttons to select between 1, 3, 6, 12 or OFF (See TABLE 1). This is the number of months until the CHANGE FILTER reminder will be displayed. 5. Press the button repeatedly until DONE is displayed. 13

CHANGE FILTER CHANGE FILTER TABLE 1 FILTER TYPE CHANGE FREQUENCY THERMOSTAT SETTING Disable the feature Disposable Panel 1 month 1 TO SET NUMBER OF WEEKEND EVENTS (MODELS 8363, 8365 AND 8366 ONLY) Use this feature to set the number of events for the weekend program. The default value is 4 events (The ENERGYSTAR setting), which will result in the LEAVE and RETURN events to be used during programmed operation. If your schedule is such that the home or building is generally occupied during the weekends, switch to 2 events on the weekend. This will cause the LEAVE and RETURN events to be ignored during programmed operation. 1. Place the MODE switch in the OFF mode. 2. Push and hold both of the temperature buttons simultaneously ( and ) until ROOM and OFF are no longer displayed. 3. Press the button several times until WAKE, LEAVE, RETURN, SLEEP is displayed on the thermostat. 4. Press the or buttons to toggle between the two selections. 5. Press the button when done. DONE will appear on the display and the thermostat will reset. OFF Washable Electrostatic 3 months 3 Extended Media (Aprilaire) 6-12 months 6 or 12 WAKE SLEEP WAKE LEAVE RETURN SLEEP SA SU SA SU 14

LIMITED WARRANTY Your Research Products Corporation Aprilaire Thermostat unit is expressly warranted for two (2) years from date of installation to be free from defects in materials and workmanship. Research Products Corporation s exclusive obligation under this warranty shall be to supply, without charge, a replacement for any thermostat which is found to be defective within a two (2) year period and which is returned, together with the date of installation, no later than thirty (30) days after said two (2) year period by you to either your original supplier or to Research Products Corporation, Madison, Wisconsin 53701. THIS WARRANTY SHALL NOT OBLIGATE RESEARCH PRODUCTS CORPORATION FOR ANY LABOR COSTS AND SHALL NOT APPLY TO DEFECTS IN WORKMANSHIP OR MATERIALS FURNISHED BY YOUR INSTALLER AS CONTRASTED TO DEFECTS IN THE THERMOSTAT ITSELF. IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SHALL BE LIMITED IN DURATION TO THE AFORESAID TWO YEAR PERIOD. RESEARCH PRODUCTS CORPORATION S LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES, OTHER THAN DAMAGES FOR PERSONAL INJURIES, RESULTING FROM ANY BREACH OF THE AFORESAID IMPLIED WARRANTIES OR THE ABOVE LIMITED WARRANTY IS EXPRESSLY EXCLUDED. THIS LIMITED WARRANTY IS VOID IF DEFECT(S) RESULT FROM FAILURE TO HAVE THIS THERMOSTAT INSTALLED BY A QUALIFIED HEATING AND AIR CONDITIONING CONTRACTOR. IF THE LIMITED WARRANTY IS VOID DUE TO FAILURE TO USE A QUALIFIED CONTRACTOR, ALL DISCLAIMERS OF IMPLIED WARRANTIES SHALL BE EFFECTIVE UPON INSTALLATION. Some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages, so the above exclusion or limitations may not apply to you. This warranty gives you specific legal rights and you my also have other rights which vary from state to state. Form No. 5173 09.04 B2202814A P.O. BOX 1467 MADISON, WI 53701-1467 Products For Better Indoor Air Quality MADE IN USA 2004 Research Products Corporation 15