PRODUCT DATA SHEET Sikalastic -560 GCC

Similar documents
Construction. Sikalastic -560 Economical and eco-friendly liquid applied roof waterproofing solution. Product Description.

Elastic, 1-part-polyurethane, liquid waterproofing membrane

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

PRODUCT DATA SHEET Sika Cable System

2-part Epoxy primer, levelling mortar and intermediate layer

MILMAN & ASSOCIATES STRUCTURAL CONSULTING ENGINEERS/ PROJECT MANAGERS

Sikagard -203 W (Steridex)

3-part cement and epoxy combination mortar for self-smoothing floor screeds of 3 to 7 mm

Construction. Pre-Bagged Structural Waterproofing System. Product Description. Product Data. Tests. Form

Low viscosity, solvent free elastic adhesive for wood flooring

Construction. Sikadur-Combiflex. Sealing system for cracks and problem joints with large movements DESCRIPTION

ARDEX GUIDE SPECIFICATION ARDEX Exterior Concrete Repair & Resurfacing Polymer-Modified, Cement-Based, Patch & Horizontal Overlay Materials

High-performance, 2-part epoxy anchoring adhesive

BLACK JACK ALL WEATHER ROOF COATING

Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description

Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method F (100 C) calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 28 C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Approved. Property Test/Standard Description. matt (0-35) Flash point ISO 3679 Method 1 27 C calculated IED (2010/75/EU) (calculated)

2-part epoxy textured roller and seal coat

Wecryl Waterproofing System under surfacing supplied by others

Sika Membran System For Sealing and Waterproofing Construction Gaps in Building Façades

WATERPROOFING OF WET ROOMS

VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised

ELASTOCEM. Technical features. Applications. Two-component flexible, waterproofing and protective cementitious grout.

PHOENIX Product Data Sheet (Updated on 14-Jan-2012)

INDUSTRIAL FLOORING INSTALLATION CHALLENGES. James C. Ziegler, ArmorSeal Product Manager Sherwin Williams Cincinnati, Ohio, USA

Approved. Property Test/Standard Description. gloss (70-85) Flash point ISO 3679 Method 1 30 C calculated VOC-US/Hong Kong. US EPA method 24 (tested)

Polymeric membrane for roof waterproofing

Property Test/Standard Description. semi gloss (35-70) Flash point ISO 3679 Method 1 34 C IED (2010/75/EU) (calculated)

kalox-pool draft 231 repairing refurbishing and finishing KALOX-POOL Waterproof cement-based mortar for protecting and finishing concrete.

TECHNICAL DATA SHEET HAMMERITE METAL PAINT. Smooth Hammered Satin Aerosol

WATERPROOFING FOR CONCRETE STRUCTURES

SC2000 CEMENT BONDING PROCEDURES

SIGMACOVER 300. PRODUCT DATA SHEET December 12, 2014 (Revision of November 1, 2013) DESCRIPTION

3M Scotchkote Urethane Coating 165HB

RECOATING AND RENEWING SPF ROOFING SYSTEMS

SIGMACOVER 280. PRODUCT DATA SHEET December 10, 2014 (Revision of March 1, 2014) DESCRIPTION

SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION CONCRETE BONDING COMPOUND.

DENSO WATERPROOFING SYSTEMS

Division 9. SignaFlor Pad and Pour Flooring System

SIGMAFAST 210. PRODUCT DATA SHEET December 12, 2014 (Revision of April 1, 2013) DESCRIPTION

BUILT-UP ROOF COATING SMOOTH and GRANULE SURFACE SPECIFICATION

Note: Minor color change may occur in exposed service, but corrosion protection will not be compromised

GUIDE SPECIFICATION COMBINATION SURFACE SYSTEM FOR NEW HOT MIX ASPHALT TENNIS COURTS I. PART 1 - GENERAL

Sikaflex Sealant Installation. Sika Corporation

Test report P 7013-E. InoPaz H2O. Pazkar LTD. Alon Tavor Industrial Zone AFULA / Israel. J. Magner Dipl.-Ing. N. Machill.

CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS

3 Scotch-Weld TM. Urethane Adhesives 3532 B/A 3535 B/A 3549 B/A. Technical Data January, 2010

SIKA BRIDGE DECK WATERPROOFING SYSTEM SIKALASTIC -851 BRIDGE DECK WATERPROOFING SYSTEM

Crystal Clear Sealant

Mineral waterproof coating PCI Dichtschlämme

COATING & WRAPPING OF UNDERGROUND PIPING

BEST PRACTICE GUIDE. Fibrelime Premixed Universal Plaster and Render

(T indicates a Tropicalised version with extended workability. No change has been made to the formulation)

PRODUCT DATA SHEET DESCRIPTION:

RTV162. Electronic Grade Silicone Adhesive Sealant

RAPTOR TRUCK BED LINER - BLACK

Scotch-Weld TM. Acrylic Adhesives. DP8405NS Green. Product Data Sheet. Date: March 2014 Supersedes: August 2013

Tecnoepo Flooring System 185

3 Scotch-Weld TM. Urethane Adhesives 3532 B/A 3535 B/A 3549 B/A. Technical Data March, 2002

Resurfacing Concrete. Page 1 of 5

STERI-SOFT HIGH FOOT TRAFFIC, ULTRAVIOLET RESISTANT, URETHANE RESILIENT FLOORING SYSTEM, 1/8 GREEN BUILDING FEATURES TYPICAL APPLICATIONS

Metal Rescue Rust Remover Technical Data

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

White rust on galvanized and galvanized pre-painted steel. Technical Information

NEW ELECTRICAL SUBSTATION Building 300 SECTION ETHYLENE-PROPYLENE-DIENE-MONOMER ROOFING WORK

MULTI-TIGHT 2K. The New Generation for Waterproofing Buildings

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles

Adhesive Recommendation for Altro Flooring. Porous (absorbent) subfloors (most wood subfloors and some concrete)

SECTION FLUID APPLIED ROOFING (LIGHT TRAFFIC DECKS OVER CONCRETE)

Epoxy Floor Coating Problem Solving Guide

Technical Data Sheet Art. No Kiesol. applications. Shelf-life. rate depending on application. Characteristic data of the product

PRODUCT DESCRIPTION 29/08/2014

High Performance Solutions and Compounds for Roofing and Structural Waterproofing

Scotch-Weld TM. Epoxy Adhesive 1838 B/A Green 1838 B/A Tan 1838-L B/A Translucent. Technical Data February, Product Description

Technical Data Sheet February 2014

STAYFLEX CORROSION CONTROL AND THERMAL INSULATION SYSTEM

Mold Preventing I nterior System

CONIROOF : Tailor-made Solutions for your Roof CONIROOF

Black epoxy paste adhesive system

Colorado State University. Durrell Center Roof Repair

MARTIN TESTING LABORATORIES (MTL) PAINTS AND COATINGS TESTING CAPABILITIES

Araldite AV 170. Advanced Materials. One component epoxy adhesive. Structural Adhesives. Key properties. Description. Product data.

Baumit Renders for Porotherm Masonry. Application Guidelines. n Light and easy application n Tried and tested

738-B-297 POLYMERIC CONCRETE BRIDGE DECK OVERLAY. (Adopted )

USER GUIDE Easier, Safer, Betta! WATERPROOFING

1. Adhered KEE membrane roofing system. 2. Mechanically fastened KEE membrane roofing system.

METAL ROOF RESTORATION SAMPLE DESIGN GUIDELINES

Cold trichloroethylene degreasing Film Thickness 70± 10 µm 10 minutes at 170 C (PZ 770 alone) 5 minutes 30 sec. at 220 C (maximum curing conditions)

SECTION RESURFACING CAST IN PLACE CONCRETE

BRIDGE FIELD PAINTING, REPAINTING, 412 AND PAINT RESIDUE CONTAINMENT. A. Field Painting, Bridge Repainting and Residue Containment:

Roofing. Sarnafil S EL. Polymeric membrane for roof waterproofing. Product Description

Vinyl Composition Tile Installation System

GigaCrete Specification PlasterMax

Avoiding Air Barrier Pitfalls

ENVIRONMENTAL EFFECTS ON COATINGS

09990 MOLD REMEDIATION, LEAD-BASED PAINT ABATEMENT AND ENCASEMENT OF ASBESTOS

Temperature C Cure time to reach hours LSS > 1MPa minutes

SPREFIX SPRAY INSULATION _ in the marine market.

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

Transcription:

PRODUCT DATA SHEET ECO-FRIENDLY LIQUID APPLIED ROOF WATERPROOFING SOLUTION BASED ON SIKA CO-ELASTIC TECHNOLOGY (CET) DESCRIPTION is a cold-applied, one-component waterborne liquid applied waterproofing membrane, highly elastic and UV-resistant. Suitable for use in hot climatic conditions. USES For exposed roof waterproofing solutions in both new construction and refurbishment projects For exposed roofs with many details and complex geometry when accessibility is limited For cost efficient life cycle extension of failing exposed roofs For reflective coating to enhance energy efficiency by reducing cooling costs CHARACTERISTICS / ADVANTAGES UV resistant and resistant to yellowing and weathering Highly elastic and crack-bridging Non-toxic and VOC compliant water based coating One component - ready to use Excellent adhesion on porous and non-porous substrates Seamless, fully bonded waterproofing membrane Water vapour permeable APPROVALS / STANDARDS Conforms to the requirements of LEED EQ Credit 4.2: Low - Emitting Materials: Paints & Coatings: VOC < 100 g/l USGBC LEED rating: conforms to LEED SS Credit 7.2 - Heat Island Effect-Roof, SRI 78 Conforms to Estidama requirements for reflectivity Conforms to Dubai Green Buildings for reflectivity PRODUCT INFORMATION Chemical Base Packaging Colour Shelf Life Polyurethane modified Acrylic Dispersion 20 kg plastic pails White, liquid form 12 months minimum from date of production if stored properly in original, unopened and undamaged sealed packaging. Storage Conditions Store in dry conditions in original packaging at temperatures between +5 C and +30 C. Protect from direct sunlight and frost. Density ~1.31 kg/l (EN ISO 2811-1) Solid content by weight ~65 % Solid content by volume ~48 % 1 / 5

TECHNICAL INFORMATION Tensile Strength Free film: ~1.5 N/mm 2 (DIN 53504) Permeability to Water Vapour Nil penetration (BS EN 12390 Part 8) Solar Reflectance Index 93.24 (ASTM E 1980 : 11) Service Temperature SYSTEM INFORMATION System Structure -10 C min. / +80 C max. (with reinforcement) -5 C min. / +80 C max. (without reinforcement) Roof Coating: For UV-stable coating, to extend life of old roofs or as reflective coating to enhance energy efficiency. Build up: (applied in minimum of 2 coats) Substrates: Cementitious, brick, stone, metals and existing bituminous membranes Primer: Please refer to Sikalastic Primer chart Dry film thickness: Min. 0.35 mm 0.75 mm Total consumption: Min. 1.0 kg/m 2 2.1 kg/m 2 (depending on application please refer to Sika s Technical Department for further information) Attention: Do not apply more than 0.35 kg/m 2 per coat for layers without reinforcement. APPLICATION INFORMATION Ambient Air Temperature Relative Air Humidity Substrate Temperature Dew Point Substrate Moisture Content +8 C min. / +40 C max. 80 % max. +8 C min. / +40 C max. Beware of condensation. Surface temperature during application must be at least +3 C above dew point. < 6 % moisture content. No rising moisture according to ASTM (Polyethylene-sheet). No water / moisture / condensation on the substrate. 2 / 5

Substrate Pre-Treatment Substrate Primer Consumption [kg/m 2 ] Cementitious substrateluted di- with 10 % water. Brick and Stone diluted with 10 % water. Bituminous felt Sikalastic Metal ~0.2-0.3 Primer or Sikalastic - 560 GCC diluted with 10 % water. Please consult with our Technical Services Department prior to use. Metals (Ferrous or galvanised Sikalastic Metal ~0.2-0.3 metals, lead, copper, aluminium, brass or stainless steel) Primer or Sikalastic - 560 GCC diluted with 10 % water. Please consult with our Technical Services Department prior to use. Paints diluted with 10 % water subject to adhesion and compatibility tests. Waiting Time / Overcoating These figures are theoretical and do not include for any additional material required due to surface porosity, surface profile, variations in level and wastage etc Before applying on primer diluted with 10 % water: Substrate Temperaturity Relative humid- Minimum Maximum 1) +10 C 50 % ~4 h 1 month +20 C 50 % ~2 h 1 month +30 C 50 % ~1 h 1 month Before applying the base coat of on the second coat of allow intermediate coats to fully cure Substrate Temperaturmidity Relative hu- Minimum Maximum 1) +10 C 50 % ~8 h 3 months +20 C 50 % ~6 h 3 months +30 C 50 % ~4 h 3 months 1) Assuming that all dirt has been removed and intercoat contamination is avoided. Applied Product Ready for Use Note: Times are approximate and will be affected by coating thickness and changing ambient conditions particularly temperature and relative humidity. Low temperature and high humidity retard curing, while high temperatures and low humidity accelerate curing progression. The above times are based on a coating thickness of 0.35 kg/m 2. Substrate Temperature Relative humidity Touch dry Rain, water & condensation resistant Full cure +10 C 50 % ~4 h ~12 h ~6 d +20 C 50 % ~2 h ~8 h ~4 d +30 C 50 % ~1 h ~4 h ~2 d Note: Times are approximate and will be affected by coating thickness and changing ambient conditions particularly temperature and relative humidity. Low temperature and high humidity retard curing, while high temperatures and low humidity accelerate curing progression. The above times are based on a coating thickness of 0.35 kg/m 2. 3 / 5

APPLICATION INSTRUCTIONS SUBSTRATE PREPARATION All substrates must be cleaned and prepared using high pressure water jet. Abrasive blast cleaning, scarifying equipment to or other suitable approved mechanical methods. Cementitious substrates: New concrete should be cured for at least 28 days and should have a pull-off strength 1.5 N/mm 2. Loose friable material and weak concrete must be completely removed by mechanical means to achieve an open textured surface and all surface defects such as blowholes and voids must be fully exposed. Repairs to the substrate, filling of joints, blowholes/voids and surface leveling must be carried out using the appropriate Sika products. Refer to Sika s Technical Department for further advice. High spots must be removed by for example grinding. Outgassing is a naturally occurring phenomenon of concrete that can produce pinholes in subsequently applied coatings. The concrete must be carefully assessed for moisture content, air entrapment, and surface finish prior to any coating work. Installing the either when the concrete temperature is falling or stable can reduce outgassing. Prime the substrate before applying the Sikalastic - 560 GCC systems. Brick and stone: Mortar joints must be sound and flush pointed. Use localised reinforcement over connection joints and prime before applying. Bituminous felt: Ensure that Bituminous felt is firmly adhered or mechanically fixed to the substrate. Bituminous felt should not contain any badly degraded areas and be primed before applying Sikalastic -560 GCC. Metals: Metals must be in a clean sound rust free condition. Metals surfaces must be free of oil and greases. Abrade exposed surfaces to reveal bright metal. Use localised reinforcement over joints and fixings. Paints/Coatings: Ensure the existing material is sound and firmly adhered. Remove any oxidized layers and use localised reinforcement over joints. Existing SikaRoof CET Systems: The existing SikaRoof CET Systems should still be soundly adhered to the substrate be clean, dust free and dry. MIXING Prior to application, stir thoroughly for 1 minute in order to achieve a homogeneous mixture using a slow speed (300-500 rpm) drill and basket type paint mixer. Over mixing must be avoided to minimise air entrainment. APPLICATION Prior to the application of the priming coat must have cured tack-free. Protect adjacent areas from splashes, over painting, damage etc. with an adhesive tape or plastic. is applied in 2 6 coats as per the required system. Prior to the application of each coat the indicated waiting times must be followed. is applied at areas having high movements, irregular substrate or to bridge cracks, joints and seams on the substrate. Please note, always begin with detailing works prior to waterproofing the horizontal surface. Tools: High Pressure Jet Washer (minimum 150 bar): If dust, vegetation, moss / algae or other contaminants are present on the existing roof, a power washer is required to clean the substrate prior to the application of SikaRoof Systems. Existing chippings should be removed by hand or scabbling prior to power washing. Squeegee: Useful when removing excess water from the roof after overnight rain Drill and paddle: should be mixed for one minute using a slow speed (300-500 rpm) drill and basket type paint mixer. Solvent resistant short-piled roller: Used in the application of to ensure a consistent thickness of the seamless SikaRoof systems. Thick hair brush: For application of to all details and penetrations. Airless spray equipment: Used only for the roof coating systems / top coats of reinforced systems. Two spray applied layers is the minimum requirement. The pump should have the following parameter: minimum pressure: 220 bar minimum output: 5.1 l/min minimum Ø nozzle: 0.83 mm (0.033 inch) For example: Wagner Heavycoat HC 940 E SSP Spraypack. Note: Please refer to the most recent issue of the specific Method Statement CLEANING OF TOOLS Clean all tools and application equipment with water immediately after use. Hardened / cured material can only be removed mechanically LIMITATIONS Do not apply on substrates that have rising moisture. Always apply during falling ambient and substrate temperature. If applied during rising temperatures pin holing may occur from rising and expanding air. may be flood tested when fully cured using 50 millimeter depth of water for a maximum period of 24 hours. Ensure that each coat of is totally dry and the surface is without pinholes before applying further coats. Do not apply if inclement weather such as rain, fog or extreme humidity (80 % maximum) causing condensation is expected. Ensure that the applied has sufficient curing time (see curing times above) before any such inclement 4 / 5

weather is expected. Do not allow temporary ponding or moisture (Dew, Condensation etc) to remain between coats on any horizontal surfaces or until the final coating has totally cured. Brush or mop surface water away during this time. It is recommended to carry out Adhesion and Compatibility tests with the Primer prior to application of following coats. should not be applied on roofs subject to long-term ponding water especially with subsequent periods of frost. In cold climatic zones for Roofing structures with a pitch of less than 3 % appropriate drainage measures must have to be considered. If aesthetics are important and normal drying times are to be achieved, do not apply top coats with consumption rates greater than 0.35 kg/m 2. Do not apply directly on insulation boards. Instead use a separation layer like Sikalastic - Carrier between insulation board and Sikalastic -560 GCC. can be applied at areas with high movements, irregular substrate or to bridge cracks, joints and seams on the substrate as well as for details. can be used as total reinforcement or for partial reinforcements over dynamic cracks and joints. is not recommended for pedestrian traffic. In case pedestrian traffic is unavoidable, shall be covered with appropriate paving materials. Do not apply cementitious products for example tile mortar directly onto. Use an alkaline barrier, for example kiln dried quartz sand. is to be used mainly in exposed applications and is not for inverted buried systems. should not be subject to permanent water immersion. Whilst is resistant to most commonly encountered atmospheric pollutants, propriety cleaning solutions and environmental spoilage, the suitability of the product for use in applications with increased chemical resistance requirements should first be established in consultation with our Technical Department. Overcoating after 3 months exposure, requires adhesion tests. BASIS OF PRODUCT DATA All technical data stated in this are based on laboratory tests. Actual measured data may vary due to circumstances beyond our control. LOCAL RESTRICTIONS Please note that as a result of specific local regulations the declared data and recommended uses for this product may vary from country to country. Please consult the local for the exact product data and uses. ECOLOGY, HEALTH AND SAFETY For information and advice on the safe handling, storage and disposal of chemical products, users shall refer to the most recent Safety Data Sheet (SDS) containing physical, ecological, toxicological and other safety-related data. LEGAL NOTES The information, and, in particular, the recommendations relating to the application and end-use of Sika products, are given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled and applied under normal conditions in accordance with Sika's recommendations. In practice, the differences in materials, substrates and actual site conditions are such that no warranty in respect of merchantability or of fitness for a particular purpose, nor any liability arising out of any legal relationship whatsoever, can be inferred either from this information, or from any written recommendations, or from any other advice offered. The user of the product must test the product s suitability for the intended application and purpose. Sika reserves the right to change the properties of its products. The proprietary rights of third parties must be observed. All orders are accepted subject to our current terms of sale and delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product concerned, copies of which will be supplied on request. SIKA NORTHERN GULF Bahrain / Qatar / Kuwait Tel: +973 1177 38188 sika.gulf@bh.sika.com SIKA SOUTHERN GULF UAE / Oman / SIC Tel: +971 4 439 8200 info@ae.sika.com SIKA SAUDI ARABIA Riyadh / Jeddah / Dammam Tel: +966 11 217 6532 info@sa.sika.com Sikalastic-560GCC_en_AE_(06-2016)_1_1.pdf 5 / 5