FC2040 Fire control panel

Similar documents
FC722 Fire control panel

FC722. Fire control panel. Cerberus PRO. FS720 series, IP6

Fire control panel (modular)

Cerberus PRO product catalog

Answers for infrastructure. Sinteso control panels clear concept, efficient operation

Input module, input/output module

FDCI222, FDCIO222, FDCIO224 Input module Input/output modules

DBS720 / FDS221-R / FDS221-W Sounder base, Alarm sounders

Product Information Fire alarm panel 8000 C

Programmable set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

DM1101, DM1103, DM1104 DM1103-L, DM1103-S Manual call points Manual release button and emergency stop button

Voice alarm system E100 the new standard for safe evacuation

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

DLO1191 Linear smoke detector

FIREDEX Conventional Fire Panels

TX OPEN RS232/485 module

DCS Data and communication server

Repeaters and Mimics Data Sheet

Overview. Alarm console supports simultaneous viewing of both live and recorded video when alarm events are selected

Thyristor-controlled power supplies and battery chargers

How can I protect valuable assets from fire and ensure business continuity?

PRODUCT CATALOGUE.

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Data Sheet FUJITSU Server PRIMERGY CX420 S1 Out-of-the-box Dual Node Cluster Server

IMR 6000/10../20../30

Clino Call DECTplus. Wireless communication

Begin using tomorrow s security features today.

SuperIOr Controller. Digital Dynamics, Inc., 2014 All Rights Reserved. Patent Pending. Rev:

Swiss Time Systems. The new multipurpose time server for the LAN and NTP-based Distributed Time System. by MOBATIME DTS 4138.

SECTION DETECTION AND ALARM

5-port / 8-port 10/100BaseTX Industrial Ethernet Switch User Manual

M2M/IoT Solutions.

Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter

Chassis, Power Supply, and Element Management

SMS GSM Alarm Messenger

M O N I T O R I N G S O L U T I O N S INFRASTRUCTURE MANAGEMENT SOLUTIONS. Varicontrol-P. The Integrated Rack Management System

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

Highly flexible the right KNX/DALI gateway for every requirement

ENGINEERING SPECIFICATIONS SENSAPHONE IMS-4000

FC18 Controller(Interlocking) Product Manual

MAJORSINE Power Inverter

The flexible performer: ALS 306

Set for PROFINET IO in IP20 TI-BL20-EN-PN-4

NetScanner System. Toronto: , Montreal: , Toll Free: ,

Programmable set for Ethernet Modbus/TCP in IP20 TI-BL20-PG-EN-8

MLC TM Maximum Productivity and Versatility for Control without Compromise!

Building Technologies

IntesisBox KNX LG Air Conditioning

40.3. Control Relays and Timers

SEZ220. Signal Converter. Synco 200. With preprogrammed standard applications Freely programmable Menu-driven operation. Use

SNMP-1000 Intelligent SNMP/HTTP System Manager Features Introduction Web-enabled, No Driver Needed Powerful yet Easy to Use

SIMATIC S It s the Interplay that makes the difference. Siemens AG All Rights Reserved.

Rack mounted telephone- and leased line modem for industrial applications

Communication Unit 560CMU05 Data sheet

Versions. Q.station Q.station T. Q.station D. Q.station DT x x

Temperature & Humidity SMS Alert Controller

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Expansion Modules & Accessories

Fire alarm system EBL512 G3

Permissible ambient temperature Operation Storage, transport

TrueAlarm Fire Alarm Systems

INTELLIGENT FIRE ALARM CONTROL PANELS. MR-2100/MR-2200 Intelligent Fire Alarm Control Panels MEA. Features. Description

Environmental data Temperature: -20 C to +55 C (Operating) -55 C to +85 C (Storage) Humidity: 0 95%

DCS data and communication server

HMI display Installation Guide

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Eight frames in three different sizes provide stylish and practical housing for the Crystal Vision modular product range

PCS0100en Persy Control Services B.V. Netherlands

OZW30. Central Unit SYNERGYR

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

TAC I/NETTM. Intrusion Alarm System

Automation Unit TM 1703 ACP Flexible automation and telecontrol

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

AIS750 Series Alarm Annunciator

MM8000 safety and security with smart danger management. A scalable and flexible management station for any requirement. Answers for infrastructure.

Modbus Server SAMSUNG Air Conditioners

BACnet router for BACnet/IP BACnet/LonTalk BACnet MS/TP

INTELLIGENT CONTROL MODULE SA-2000-II HARDWARE MANUAL. Access Technologies International, Inc.

NGSS Data Consolidator (DC)

TrueAlarm Fire Alarm Systems

Study on the Auto Air Conditioning Controller Testing System Based on Lab Windows/CVI

PowerGem Pro Uninterruptible Power Supply

MPR-Systems. Mini Power Racks 1200 W W

NJP-400A NJP-401A. Safely into a new day. Advanced modular FIRE ALARM CONTROL PANEL with additional functionality. I m on FIRE (Bruce Springsteen)

SYSTEM DESCRIPTION Termination Boards

IntesisBox Modbus Server Fidelio IP

Monitoring,Telemaintenance,... HACCP. Innovative Supermarket solutions. Tecnologia ed Evoluzione

How To Use A Sim Sims 2.2 (Blackberry) With A Sims 3 (Blackintosh) And Sims 4 (Blackburn) (Blackford) (Whiteford) For A Long Time (Blackwood) (Blue

AXIS 262+ Network Video Recorder

Digital I/O: OUTPUT: Basic, Count, Count+, Smart+

Controllers. The integrated standard software guarantees highest quality standards! Simple and safe operation. Specific and clear indication

QFP910. Water detector. Building Technologies. CE1N2732en Synco living

Controller board and power supply for vivimat III systems

Phase Modular Finally the benefits of Modular ups are for all

T a b l e o f C o n t e n t s

IntesisBox. KNX SAMSUNG Air Conditioning. Gateway for integration of Samsung air conditioners into KNX control systems. RS485.

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

Building Technologies

KNX IP Gateway. Light-Control R. User manual-ver.1 LC-IPGW-001. KNX Gateway. KNX/EIB Intelligent Installation Systems

Fujitsu PRIMERGY BX600 S3 Blade Server

Transcription:

FC2040 Fire control panel Series FS20 (MP1.1) Sinteso TM Compact, prefabricated, microprocessor-controlled fire control panel for the connection of up to 504 addresses Fire control panel can be used as stand-alone version or networked Up to 16 stations such as fire control panels and fire terminals (in any arrangement) can be connected in one network Integrated emergency operation function Redundant network node, degrade operation according to EN 54 Fast Ethernet interface for heterogeneous network Integrated user-friendly operating unit Optional printer, key switch, LED indicators Slots for RS232, RS485 serial ports Emergency power supply for up to 72 h for emergency operating time Detection and automatic read-in (auto configuration) of all FDnet devices, providing immediate simple operation Processes signals from the Sinteso TM detector series Time and situation-dependent change over of the detector parameters Floor repeater displays, operating panels and alarm devices in the detector loop (FDnet) Flexible programming of complex applications and controls Stored data can be uploaded via remote access Firmware download of all processor controlled control panel components

System overview 2

Expansion to a complex fire detection system The high-performance FCnet/SAFEDLINK makes it possible to network up to 16 FC20xx fire control panels and FT2040 fire terminals together as required. The innovative redundant network nodes not only set new standards in terms of failsafe characteristics but also for high-speed data transfer. In addition, an Ethernet connection is available at each station. This Ethernet connection enables a maximum of 2 stations to be networked together (not EN 54-compliant). Characteristics For details about system networking, please refer to product data sheet 008955. The FC2040 is a compact fire control panel with an integrated operating unit that can process signals from Sinteso TM devices. The control panel can be used as a stand-alone unit or in a network. The control panel can be programmed with a user-friendly engineering tool (software) to create a system with great versatility. All detector lines are monitored for ground faults. Adaptation of the user text directly on the terminal or with the software engineering tool. Up to 1000 events can be stored according to various criteria. Automatic summer/winter time change. Connection of danger management systems via BACnet 3

Functional elements Operating unit The following are located on the operating unit: CPU module and the electronics for the operating unit Ethernet connection Slots for RS232, RS485 modules and networking modules (SAFEDLINK) Space for 'Kaba' or 'nordic' key switch Space for event printer Peripheral board The following are located on the peripheral board: Connection terminals for FDnet loops, remote transmission (alarm, fault), horn outputs, programmable control inputs/outputs, monitored alarm and fault output, degrade supply, power supply Power supply 150 W, degrade supply The power supply supplies the hardware and charges the batteries The batteries supply the emergency power in case of power failure Housing A pivoting mounting panel can be installed on the housing backplane to allow installation of: 1 fire brigade periphery module Configuration An engineering tool permits the system to be adapted to specific customers' requirements. Application ranges The FC2040 is ideally suited for medium-sized applications, e.g. in industrial plant, regional banks, office complexes, etc. or when networked as part of much larger applications. Operation Each control panel has an integrated operating panel. Additionally the control unit can be operation for another separate FT2040 operator terminal. For details and further information, please refer to product data sheet 009386. 4

Overview of FC2040 fire control panels FC2040-AA FC2040-AE With 2 LED indicators (48 LED indicator groups) Housing (Comfort) FC2040-AG With 4 LED indicators (96 LED indicator groups) 4 loop 4 loop 4 loop With power supply (150 W) With power supply (150 W) With power supply (150 W) Battery capacity max. 26 Ah Battery capacity max. 26 Ah Battery capacity max. 26 Ah FTO2001-A1 Event printer FH2002-A1 Housing (Standard) Options FH2003-A1 Housing (Comfort) Can be installed in FC2040-AA FC2040-AE FC2040-AG RS232 module must be ordered separately FCM2006-A1 (2xLED ind.) Operating add-on Empty housing for various applications e.g. for additional batteries, operating add-ons or event printer FCM2007-A1 (4xLED ind.) 48 LED indicator groups 96 LED indicator groups For retrofitting For retrofitting 5

Configuration of FC2040 in housing (Comfort) 1 7 19 2 16 8 5 15 17 18 9 3 13 11 12 13 4 6 14 Basic equipment Designation Notes 1 Rear (Comfort) FHA2003-A1 2 Peripheral board (4-loop) FCI2004-A1 Nos. 1-5 > Basic equipment for each FC2040-xx (Comfort) 3 Power supply (SV 24V-150 W) V24230-Z6-A2 4 Mains terminals on DIN mounting rail TS35 Space for socket, relay modules, etc. 5 Operating unit FCM200x-xx Combined system operating panel and CPU, incl. cover 6 Space for batteries 2 x 12 V / 7 26 Ah Options 7 Relay module Z3B171 Relay for fire controls 8 Event printer FTO2001-A1 For event logging 9 Key switch (Kaba) FTO2005-C1 Key switch (nordic) FTO2006-B1 For operating access rights 10 Mounting plate FHA2007-A1 E.g. for fire brigade peripheral 11 RS485 module (isolated) FCA2002-A1 For peripheral devices with RS485 port 12 RS232 module (isolated) FCA2001-A1 For stations with RS232 port 13 Networking module (SAFEDLINK) FN2001-A1 For networking various stations Battery (12 V, 7 Ah, VDS, V0) FA2003-A1 14 Battery (12 V, 12 Ah, VDS, V0) FA2004-A1 For emergency power supply Battery (12 V, 26 Ah, VDS, V0) FA2006-A1 15 Fire brigade periphery module FCI2001-D1 For Germany (FBF, FSK, HM, isolating element, etc.) 16 Door contact kit FCA2009-A1 For monitoring the cover 17 Battery kit (9 Volt) FCA2010-F1 For 9 Volt battery (3 rd voltage source only for France) 18 Lithium battery 9 V / 1 Ah For FCA2010-F1 19 19" mounting kit FHA2016-A1 For the installation in 3 rd party housings 20 Power supply kit (150 W, B) FP2005-A1 For additional power supply 20 8 10 15 6

Technical data Mains voltage Power supply Operating voltage Operating current Battery capacity Battery monitoring Mains monitoring Connectable detector series Number of lines Loops or stub lines 115/230 VAC 150 W 21 28.6 VDC max. 5 A 2 x 12 V, 26 Ah yes yes Sinteso TM (FDnet) Number of addresses max. 504 Integrated inputs/outputs Relay output 1 each Remote monitoring alarm / fault Monitored outputs Alarm / fault Horn Programmable inputs/outputs Operating unit Plug-in position for RS232, RS485 serial ports 4 8 1 each 2 12 integrated 2 Plug-in position for networking modules 2 Ethernet connection RJ45 1 Operating temperature 8 +42 C Storage temperature 20 +60 C Humidity (no condensation permitted) at T = 25 ±3 C at T = 40 ±2 C Dimensions (W x H x D) Color Housing Cover Protection category (IEC 60529) Approvals VdS LPCB 95 % rel. 93 % rel. 430 x 796 x 160 mm light grey, RAL 7035 pure white, RAL 9010 IP30 G206110 pending 7

Details for ordering Type Part no Designation Weight Fire control panels FC2040-AA A5Q00016100 Fire control panel (4-loop) 18.280 kg FC2040-AE A5Q00016852 Fire control panel (4-loop) 19.200 kg FC2040-AG A5Q00016854 Fire control panel (4-loop) 21.080 kg Options Z3B171 4843830001 Relay module 250 VAC / 10 A (1 relay) 0.042 kg FTO2001-A1 A5Q00010126 Event printer 0.250 kg A5Q00017619 Replacement printer rolls (10 rolls) 0.090 kg FTO2005-C1 A5Q00010113 Key switch (Kaba) 0.100 kg FTO2006-B1 A5Q00010129 Key switch (nordic) 0,050 kg FHA2007-A1 A5Q00010151 Mounting plate 0.800 kg FCA2002-A1 A5Q00009923 RS485 module (isolated) 0.067 kg FCA2001-A1 A5Q00005327 RS232 module (isolated) 0.068 kg FN2001-A1 A5Q00012851 Network module (SAFEDLINK) 0.077 kg FCI2001-D1 A5Q00013100 Fire brigade periphery module 0.482 kg FH2002-A1 A5Q00018931 Housing (Standard) 7.500 kg FH2003-A1 A5Q00009906 Housing (Comfort) 15.000 kg FCM2006-A1 A5Q00021771 Operating add-on (2xLED ind.) 2.600 kg FCM2007-A1 A5Q00021772 Operating add-on (4xLED ind.) 2.800 kg FCA2009-A1 A5Q00012317 Door contact kit 0.015 kg FCA2010-F1 A5Q00012569 Battery kit (9 Volt) (only France) 0.100 kg A5Q00004142 Lithium battery 9 V / 1 Ah (for FCA2010-F1) 0.037 kg FHA2016-A1 A5Q00020179 19" mounting kit 3.000 kg Additional power supply FP2003-A1 A5Q00016005 Power supply kit (70 W) 0.650 kg FP2004-A1 A5Q00020825 Power supply kit (150 W) for installation in 1.366 kg empty housing FP2005-A1 A5Q00018779 Power supply kit (150 W) for the cascading 1.100 kg Batteries FA2003-A1 A5Q00019353 Battery (12 V, 7 Ah, VDS, V0) 2.450 kg FA2004-A1 A5Q00019354 Battery (12 V, 12 Ah, VDS, V0) 3,930 kg FA2006-A1 A5Q00019356 Battery (12 V, 26 Ah, VDS, V0) 7.572 kg Siemens Switzerland Ltd Group International Headquarters Gubelstrasse 22 CH-6301 Zug Tel. +41 41 724 24 24 Fax +41 41 724 35 22 www.sbt.siemens.com 2006 Copyright by Siemens Switzerland Ltd Data and design subject to change without notice. Supply subject to availability. Document no. 009384_b_en_-- Manual FS20 Edition 12.2006 Section 1