Endoscope reprocessing the way it should be MEDIVATORS

Similar documents
SITE REQUIREMENTS AND INSTALLATION INSTRUCTIONS

Endoscope Tracking System

Christina Bradley Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK

ON TRACK Reprocessing Inservice / Competency for GI Endoscopes (EVIS, EXERA, EXERA II)

A new wave in instrument washing and disinfection Introducing the new HYDRIM G4 WD series

DocuSign Envelope ID: C9E26C4D-6C1E A-F86C07868EC4. Capsule Endoscope. Installation & Software User Guide

Clinic Washer-Disinfectors. Washer-Disinfector Line

Laboratory & Scientific Line. Bulk Steam Sterilizers. Since

ETD3 the new standard in endoscope reprocessing.

University of Kentucky / UK HealthCare Policy and Procedure. Policy # A03-030

National Endoscopy Programme. Decontamination Standards for Flexible Endoscopes

ARES flexible endoscope automated reprocessing system

data sheet DONATELLO Rev. I emiss - 25/10/ PRO03 code Automatic tissue processor DONATELLO

Expert Opinion. on the efficacy of. EndoDet and EndoDis + EndoAct. for cleaning and disinfection of. Olympus Gastroscope Type GIF-2T200.

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

CORNER FRIDGE REFRIGERATION UNIT INSTALLATION AND OPERATION INSTRUCTIONS

CARE HOMES AND NURSING HOMES

SYSTEM 1E LIQUID CHEMICAL STERILANT PROCESSING SYSTEM

Hygiene Standards for all Food Businesses

FVA THIRD-GENERATION VERTICAL SATURATED-STEAM STERILIZERS

MELA quick 12+ Compact. Fast. Strong.

AGRI-ALERT 128 TOUCH AGRI-ALERT 800EZE ALARM SYSTEMS

Reprocessing. Critical & Semi-Critical Equipment

Software Features of Auto Gas Gas Analyzer Features HC, CO, CO2, Lambda, Air Fuel, NOx. Has optional RPM and Oil Temp.

Vertical Display and Storage B SKOPE Gen2: Three Door Chiller

Infection Control in the Dental Practice through Proper Sterilization

Medical Waste Autoclaves. Medical Waste Autoclaves

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MN12CES / MN10CESWW

Lava. Precision Solutions. Site Planning and Installation Guide

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MM14CCS. Voltage rating: 115V~60Hz Power rating : 1400W

PITE 3921 Battery Monitoring System User Manual P V1.0

GETINGE GEW 2100LS CAGE AND RACK WASHER PREVENTING CONTAMINATION IN ANIMAL CARE

Benchmark. WASH l RINSE l PASSIVATE l DRY. Benchmark Precision Aqueous Cleaning Systems Modular Design, Superior Clean, Unwavering Service

site monitoring Kit Site Monitoring Kit User Manual we prove it.

CHILDCARE SETTINGS. Childcare Settings

GETINGE AER RANGE A SAFER WAY TO REPROCESS ENDOSCOPES. Getinge AER Range 1

Portable Air Conditioner. OWNER S MANUAL Read these instructions before use. Model: MF08CESWW. Voltage rating: 115V~60Hz Power rating : 800W

Partnership. Medical Waste Autoclaves. Medical Waste Autoclaves

Laboratory Line. Vertical and Bench-Top Life Science Autoclaves

Designed for multi-injector endurance testing, the

ESP 20/20. Compressor Monitoring System

SALTER AIRE Plus COMPRESSOR Model 8350 / 8352 / Instruction Manual. Page 1 of 9

K ODAK D IRECTV IEW CR 850 SYSTEM

Wireless LAN. Setting Guide. Setting the Wireless LAN. Installing the Software. Troubleshooting. Prepare for Wireless LAN Connection P.2 P.4 P.10 P.

FAQs. Conserve package. Gateway... 2 Range Extender... 3 Smart Plug... 3 Thermostat... 4 Website... 7 App and Mobile Devices... 7

Company background and. portfolio overview

MIC-WKT and MIC-WKT-IR

F453. TiF453. User guide 10/11-01 PC

Hardware Guide for the Classic and Elite CR Systems PN 9G9637 Version 1.0

Providing Temperature. Regulated Warm Water. to your Sanicare. Hand Spray Bidet

Phase Modular Finally the benefits of Modular ups are for all

NESCAFÉ Solution 8/60 Beverage System. Operations Manual

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

3. SEISCO PARTS & SERVICE REMOVAL AND REPAIR GUIDE

Department: Manager: Safety Coordinator: Date:

Maxi Pressurisation Units (Maxi, Maxi Plus & HP)

Operation and Installation Manual

GenStore Archive Cabinet

-86 C Freezer Accessories. New Brunswick Freezer Accessories. A wide selection of racks, monitoring systems and more!

PORTABLE AIR CONDITIONER

Thermo Scientific Barnstead TII Pure Water Systems. Pure water. Pure research. Total confidence.

OPL BASIC. Dosing System for Professional Laundry machines. Contents

INFECTION CONTROL SURVEYOR WORKSHEET

Watts Pure Water Systems

el-720 Carbon Dioxide Gas Leak Detector User s Guide

ECMO AND LIFE SUPPORT SYSTEMS QUADROX PLS AND ROTAFLOW HARDWARE AND ACCESSORIES

IC+ NEW inverter compressor technology delivers energy saving, high performance cooling

Mobile Video Cystoscopy from KARL STORZ

LeakFilm. Protecting your high-tech assets with innovative, user-friendly technology for liquid leak detection

t-doc Instrument Intelligence take command of your operations Always with you

Biosafety Program University of Colorado. BSL-1 Audit Checklist

Tabletop Line. Automatic and Semi-Automatic Autoclave Series

Providing Temperature. Regulated Warm Water. to your Sanicare. Hand Spray Bidet

Cleaning and High Level Disinfection of Semi-Critical Medical Devices

CONTAMINATION CONTROL FOR ELECTRONIC AND SEMICONDUCTOR APPLICATIONS

SIS-PM / SiS-PM-841 / SIS-PMS User Manual. Table of contents

Hamilton Verso. Medium to Large-Capacity Automated Sample Storage

Proposed A&A work at E-Commerce Air-Hub at SATS Airfreight Terminal 1 (AFT1)

WALLACE MAXIPUMP 3000, 5000, 6000 and HYDROJET 30P, 30C AND HJ400 INSTALLATION AND MAINTENANCE INSTRUCTIONS

Coldrooms designed for your application

CARING FOR YOUR WATER HEATER

Direct Water purification system Pure & ultrapure water directly from tap water

TrueAlarm Fire Alarm Systems

A HOMEOWNERS GUIDE ON-SITE SEWAGE MANAGEMENT SYSTEMS

There may be an additional section covering health and safety concerns which fall outside the scope of the national food hygiene rating scheme.

Both health-care facility classification and area classification, as per CSA, determine the design requirements.

USER INSTRUCTIONS FOR 10 LITRE PORTABLE DEHUMIDIFIER MODEL NO. DHMD102

E Data Domain Specialist Exam for Implementation Engineers. Version: Demo. Page <<1/7>>

NetScanner System. Toronto: , Montreal: , Toll Free: ,

Safe Work Procedure Sharps and Bio-hazardous waste handling and disposal

RQIA Infection Prevention/Hygiene Announced inspection

Expert workflow management cobas p 312 pre-analytical system The new dimension of laboratory automation

TRIMMING TECH 150. IVD In vitro diagnostic-medical device. General information. Technical datasheet Trimmingtech150

Fumigation of Safety Cabinets

Standard Operating Procedure

Communication Interface Units. CIU Prime & CIU Plus

Whole House Water Treatment System. Installation, Operation and Maintenance Manual. Multi-Pure Model TO15000

Quick Installation Guide

Transcription:

Endoscope reprocessing the way it should be MEDIVATORS

The MEDIVATORS ADVANTAGE REPROCESSING SYSTEM The Medivators Advantage reprocessing system includes the Advantage Plus automated endoscope reprocessor, hookup and transport cassettes and endoscope storage cabinet. This unique system is the first integrated reprocessing configuration to fully incorporate high level disinfection with drying, storage and scope security tracking. The Integrated System After pre-cleaning and manual leak testing, the endoscope is placed into a hookup cassette and the endoscope channels are connected to individual ports. The cassette is then transported from the sink area to the Advantage Plus endoscope reprocessor where automated leak testing, cleaning, high level disinfection, optional alcohol flush and air drying occurs. After process completion, the cassette with endoscope is placed directly into the pass-through cabinet for drying and storage. When the endoscope is needed for a procedure, it is removed from the cabinet via the door in the procedure room or clean area. The endoscope may also be placed in a covered transport case to reduce cross-contamination potential. T Quick, efficient endoscope transfer from Advantage Plus to storage cabinet via cassette No disconnection or reconnection of endoscope channels to cassette hookup ensures proper connectivity and time savings Minimal worker handling of endoscope optimizes infection control practices and reduces employee risk of exposure Transport in cassette reduces endoscope damage and related repairs by 25-30%* *White paper available upon request

MEDIVATORS ADVANTAGE PLU Large, easy loading, independent basins Asynchronous operation Accommodates all flexible endoscopes Advantage Hookup Cassette Scope-specific port connectors Touch-free scope handling reduces cross-contamination Designed to connect to MEDIVATORS Advantage Plus and MEDIVATORS Advantage endo STORE Cabinet Provides protection of endoscopes during transport; reduces endoscope damage Reprocesses a variety of endoscopes Compatible with all flexible endoscopes Ability to reprocess non-submersible electronic scope components Validated for reprocessing TEE Probes, dilators, cystoscopes, and semi-critical rigid scopes* *for a full list, please go to www.minntech.com Peracetic Acid High-Level Disinfectant Proven endoscope compatibility Fast endoscope availability 5-min at 20 C disinfection Reduced worker exposure Environmentally responsible Compatible with Rapicide PA and Adaspor SS

ENDOSCOPE REPROCESSOR Endoscope channel monitoring Guarantees proper hookup connection Monitors endoscope channels for blockage Ensures all channels are correctly and fully reprocessed High performance cleaning cycle Double wash feature provides consistent, thorough soil and residue removal Eliminates the variability of manual cleaning Extensive cycle data management Networking & Remote Diagnostics Network multiple systems together Connect to local or off-site server for centralized data collection Fast technical support via on-line diagnostics Automated leak testing and optional alcohol flush Enables disinfection of an endoscope prior to repair Minimizes leak-related repair costs Facilitates drying of endoscope channels Hands-free lid operation

MEDIVATORS ADVANTAGE endo STORE 190 cm Individual channel drying capability Thorough channel drying capability reduces risk of bacterial growth Each scope channel is purged with HEPA filtered air Short drying cycle reduces scope turnaround time For use with Advantage Hookup Cassettes Hookup cassette is transported from Advantage Plus reprocessor and inserts directly into shelf ventilation port one click connection Individual port connections in Hookup Cassette enables individual channel purging No reconnection to individual ports need; maximizes efficiency and saves time Designed to meet facility needs Pass-through system creates hygienic endoscope flow from reprocessing side to treatment side Narrow footprint convenient for space constraints User access control reduces theft or damage to scopes Cycle data management and storage Barcode reader for consistent data entry, scope tracking and user authorization Internal ID data storage includes scope id, operator id, entry/ removal time, location in cabinet and error/alarm messages Optional data transfer to PC via LAN connection 60 cm Shelf storage system 54 cm Shelving system stores up to eight endoscopes at a time Traceable storage time per shelf Programmable maximum storage time to meet facility requirements System alarms if maximum storage time is exceeded Advantage Transport Case Transport dirty or clean endoscopes while in the Advantage Hookup Cassette Lid reduces cross-contamination Stackable for convenient storage

Electrical Supply 240 VAC ± 10%: single phase, 50/60HZ; 10A Water Supply Minimum flow rate: 5 LPM with a pressure of 2.1 to 6 bar Water Temperature: 25 ± -5 C Hardness: less than 200 ppm Pre-filter wall space: 66 H x 96 W x 15 D cm within 100 cm of the Advantage Plus Drain 12 LPM less than 46 cm from the floor, vented Air Supply Compressed air (dry/oil free): 4 to 8.6 bar, minimum flow volume of 0.88 m 3 /h Optional air compressor, adds 28 cm to depth of unit Basin Size 48 H x 43 L x 18 D cm 114 cm 124 cm w/barcode bracket 79 cm without compressor 107 cm with compressor Distributed by 157 cm 99 cm Minntech Corporation 14605 28th Avenue North Minneapolis MN 55447 Tel: +1-763-553-3300 Fax: +1-763-553-3387 Minntech Asia/Pacific Pte Ltd No.1 A International Business Park #05-01 Singapore 609933 Tel: +65-6227-9698 Fax: +65-6225-6848 Minntech BV Sourethweg 11 6422 PC Heerlen The Netherlands Tel: +31-45-5-471-471 Fax: +31-45-5-429-695 Minntech China, Rep. Office Room 708, 7th Floor Kaiheng Center, No. 2 Chaoyangmennei Street, Dongcheng District, Beijing China, 100010 Tel: +8610-6567-8446 Fax: +8610-6567-8445 For additional information please contact your Minntech representative or visit our website at www.minntech.com/medivators 2010 Minntech Corporation. P/N 50097-481/B