ARES flexible endoscope automated reprocessing system
|
|
|
- Winfred Copeland
- 9 years ago
- Views:
Transcription
1 ARES flexible endoscope automated reprocessing system For the Environmentally conscious
2 ARES automated system for flexible endoscope reprocessing process planning, device effectiveness, monitoring and event traceability: these are the key elements in our reprocessing system to avoid the risk of cross contaminations 1 a critical process: In order to maintain a correct flow through the process, it is important to create the right environment. Steelco ARES system foresees the use of storage cassettes and a transport trolley in order to maintain the right dirty/clean flow with considerable advantages in terms of process safety. the endoscope is used In case the disinfection area is serving multiple endoscopes rooms, the use of the endoscope transport trolley for an aseptic movement is an additional safety aid and grants short-term safe storage improving the department productivity. As little time as possible should pass between the endoscope use and its manual cleaning and automated reprocessing. manual cleaning 2 As little time as possible should pass between when the endoscope has been used to when manual cleaning and automated reprocessing are performed. Immediately after use, manual cleaning should be performed following the guidelines for endoscopy operators. This assures an appropriate instrument preparation for the 2
3 5 The software management system Steelcodata allows tracing of each process phase through automatic recording or manual data entering via a PC or through the hospital main server. Moreover a remote connection for technical assistance can be requested in order to reduce maintenance intervention time and costs. process validation and endoscope usage 4 While stored in the Steelco endoscope drying cabinets, the instrument is kept under aseptic conditions which are assured thanks to HEPA filters for bacteria filtration and indirect UV light treatment. The air flow into the internal channels of the endoscope removes any water residue in the instrument. The constantly maintained positive pressure in the drying cabinet protects the instruments from any contamination and their horizontal position avoids stressing of the endoscope. The endoscope can be stored in the drying cabinet for up to 72 hours. When this time is exceeded it is necessary to reprocess the instrument using a fast disinfection cycle which is among the standard programs of the EW2. max 72 h. the endoscope is taken out from storage endoscope reprocessing endoscope storage 3 The exclusive Steelco endoscope drying cabinets are connected to the EW2 through dedicated software for a complete and automatic traceability with effortless control thanks to the touch screen panel. Steelco drying cabinets are manufactured as single or double door version, with capacity of up to 8 cassettes or up to 9 tray levels for the aseptic storage of the instruments. high level disinfection process within the AER. Furthermore, the EW2 system, thanks to dedicated chemical products manufactured exclusively by important chemical companies and to its innovative functioning, allows to reach better results than those required by the UNI EN ISO The innovative pass-through version lets the reprocessed endoscopes to be unloaded directly in a controlled and safe area. 3
4 EW 2 - Automated Endoscope Reprocessor Automatic endoscope reprocessor for low temperature washing and high level disinfection of flexible endoscopes. It is developed for the treatment of all types and brands of flexible endoscopes. The new Steelco EW 2 machine has been developed to fully comply with the ISO directives and it incorporates all the latest innovative technologies. It can be supplied in a pass-through interlocked double door version, or single door with overturning wing at an ergonomic height. Steelco EW 2 can run the washing and high-level disinfection cycle at low temperature of 2 flexible endoscopes simultaneously. For video bronchoscopes and fibrobronchoscopes the capacity can be even increased up to eight instruments per batch. It also allows the process of thermal disinfection for instruments such as rigid scopes with a specific wash cart. Pass-through interlocked double door version The modern endoscopic reprocessing department has a physical separation between the clean and the unclean area. Only frontal loading models are suitable for this purpose. Steelco automated endoscope reprocessor EW2 is available as a double-door model with interlocked doors. When opened, folding doors are also useful as ergonomic working surface for the connection of the endoscopes. Steelco is one of the world s leading manufacturers of WD s for the Central Service. Our long-term experience in the field of instrument reprocessing can be easily recognized in the innovative leadership of EW 2 machine. 4
5 EW 2 - Unique features - Compatible and tested with peracetic acid (cold disinfection) and glutaraldehyde (chemo-thermal) - RFID detection of the process chemicals - User and instrument recognition through bar code reading system or RIFD (Radio Frequency Identification). - Precise endoscope channel-check (up to 7 channels) with two independent monitoring systems through pressure and flow measurement. - Leak test at the beginning of the cycle and continuous monitoring during all cycle phases with automatic cycle stop in case of anomaly. - Dedicated individual pumps, pressure Optional and flow control for each endoscope channel. - Individual pressure and flow channel control system with data logging during the whole cycle. - Self thermal disinfection cycle at 90 C as required from the UNI EN ISO rule including endoscope basket and connections. - Disinfection of all the water used in the process with a two stage high level water filtering (0,5 μm and 0,1 μm filters) for endotoxin removal. - Complete cleaning and disinfection cycle time of 2 flexible endoscopes in 30 minutes. - The use of Steelco chemicals for cleaning and disinfection guarantees highest microbiological efficiency and documented results in the instruments biofilm removal - Integrated sterile air filter for channel leak test, purging and drying. - Data logging of all program data and instrument parameters, graphically visualized as a curve. - Large color LCD touch screen display for easy machine operation and endoscope/operator database management. - Complete documentation on integrated printer or to PC/hospital server with SteelcoData software. - Drain pump - Conductivity sensor - Light inside the chamber - Remote control assistance - RFID sensor for instrument/ operator recognition - Oil free air compressor (requires medical compressed air filtering system) - Bar code reader for instrument/ operator recognition - Steelcodata software for data management and devices remote monitoring - Medical compressed air filtering system (for air compressor or connection to no medical quality compressed air source) - Increased total power for reduced disinfection cycle time Dimensions and connections Standard electrical connection (International)* Optional electrical connection (North America) Power Noise Permitted room temperature *other available connections: monophase 230V/50Hz with total power reduced to 3550 W triphase 400/50Hz with increased total power and reduced disinfection cycle time 400V/3~+N/50Hz 208V/3~+N/60Hz 6050 W 62,4 db(a) +5 C/41 F C/104 F 710mm/27.95 min. 300mm mm/33.86 min. 50mm/ mm Top cover, must be open for maintenance 860mm/ mm/ mm/ mm/ mm mm/ mm mm mm/ mm Loading side 330mm Unloading Side 1 Demineralized water connection ¾ male DN 20 mm 1.1 Cold water connection* ¾ male DN 20 mm 2 Electrical connection * to be used if demi water is not available Medical compressed air connection ¼ male - ø8 mm pipe holder Machine drain 1 female DN 25 mm Chamber exhaust pipe connection Ø 60 mm 5
6 EW 2 - Washing carts C558 rotating wash cart for 2 flexible endoscopes Steelco Patented rotating wash cart for flexible endoscopes has been developed for effortless general operation and also for restricted space areas. The rotation of the cart assures a frontal insertion of both instruments making the connection of the washing channels easy. The process is separately controlled for each instrument. Locking device The alignment of the cart for a proper working position is assured by a one way locking device. External surface cleaning A dedicated system ensures the safe storage of the instrument during the process and a complete disinfection/ sterilization of the external surface of the endoscope. 6
7 EW 2 - Washing carts C559 wash cart with baskets for 2 flexible endoscopes Steelco has manufactured a 2 levels basket that allows the simultaneous treatment of 2 flexible endoscopes which can also be easily used in areas with restricted space. The removable tray can be used for the no-contact transportation of the endoscope to the ED 100/200 cabinets for drying and storage. The endoscopic instrument should be placed within the removable basket preventing the contact between the parts of the endoscope that can generate areas unreachable by washing/disinfection. The accessory C565 avoids endoscopic instrument overlapping points, places the connection tube and the distal tube in a constant slope to facilitate the natural drain of fluids from the channels. SAFE CASE for compliant and validated TEE probe reprocessing With Steelco SAFE CASE the electronic control and connection cable are placed inside an hermetic case and isolated from the distal tube that requires a complete washing cycle and a high level non thermal disinfection. The whole package can be placed inside a washer disinfector where an automatic, compliant and validated reprocessing cycle can be executed. To be used with a 2 level cart C559 to allow the simultaneous treatment of 2 transesophageal probes. C560 - video bronchoscope, fibrobronchoscope wash cart Wash cart for the simultaneous treatment of: 4 videobronchoscopes/ cystoscopes or 8 fiberscopes/ cystoscopes with separate control. This innovative system allows to save money but with the high process safety. Standard cycle 5 minutes at 35 C, high level disinfection cycle that can be tested with biological indicators. 7
8 EW 2 - Washing carts C563 rigid scopes wash cart Wash cart for nr. 20 rigid scopes with the possibility of luer lock connection for washing. In accordance to the UNI 15883/1 guideline and coherent to an environmental conscious behaviour Steelco strongly recommends to apply thermodisinfection process for all reusable medical devices that can be high temperature treated. EW2 endoscope reprocessor machine can run a standard thermal disinfection cleaning program. C568 endoscope storage cassettes wash cart Wash cart for nr. 2 endoscope storage cassettes. Conformity to UNI EN ISO Steelco EW2 is fully complying to the UNI EN ISO and UNI EN ISO and incorporates the most advanced technologies in this field. The process has been validated by some of the most important microbiological institutes. 8
9 EW 2 - Endoscope connections channel bioptic 1 channel bioptic 2 channel water channel air channel suction channel elevator channel aux water/co 2 leak test Connection scheme The number and kind of connections change from scope to scope. Colour coded connection for easy identification of each individual channel. Channel connections A typical connection scheme is also impressed on the washing cart for operator s aid. Endoscope position is easily identified by a number. Cart/washing machine coupling system. Connection hoses The connection hoses used in the EW 2 are flexible for easy attachment of the adapters to the endoscope and crimped thus avoiding unnecessary interruptions of the treatment program. Hoses are made with FDA-approved materials to offer protection against biofilm and can be disinfected both chemically and thermally (EW2 self disinfection cycle at 90 C). Adapters and connectors The ARES program includes a complete range of manufacturer-specific connectors for the endoscopes reprocessing. The products are characterized by a high quality manufacturing for longer life and to ensure the tight connection to the cleaning system without pressure loss. The Steelco adapters range includes connectors for virtually all flexible endoscopes from all manufacturers. 9
10 EW 2 - standard cycle description * 1- pre wash Leak test during the whole cycle * 2- main wash This is required to remove chemical residues from manual washing and to remove contaminant agents This is required to remove organic residues and microbial biofilm * 3- first rinse Rinse from the chemical residues of the previous main wash * 4- high disinfection The standard program for high level disinfection grants a 5 minutes cycle at 35 C/95 F * 5- rinse Rinse phase with 0,1µm filtered water (medical device) to assure a process with sterile water and without endotoxines. Additional rinses (opt.) with sterile filtered water from the EW2 high level water filtering system * sterile air channel purging Water residues removal from the endoscope internal channels. * EW2 performs sterile air channel purging before every single cycle phase Optimal performance with Steelco process chemicals neodisher is a registered trademark of Dr. Weigert GmbH & Co.KG In cooperation with the market leading manufacturer for process chemicals used in instrument disinfection Dr.Weigert GmbH & Co. KG, neodisher products were configured specifically for the Steelco EW2. Steelco has implemented (first in the market) the use of RFID technology for the identification of the process chemicals together with the registration of the lot number and expiration date. An important safety application that keeps the process monitored and documented also in this often neglected aspect. Steelco neodisher SC This product guarantees the excellence in cleaning performances and protection of the materials even at dosing temperature of 35 C/95 F. Steelco neodisher Septo PAC Based on peracetic acid, this disinfectant chemical has a broad spectrum of activity providing secure and fast processes with the best material compatibility. neodisher Mediklar The use of this rinsing agent improves the drying results of the instruments. By using Steelco process chemicals the EW 2 automatic endoscope reprocessor reaches the highest efficiency results proven by microbiological tests together with complete documentation and instruments maximum safety conditions. Water filter second step 0,1 micron 10 inches Water filter first step 0,45 micron 10 inches Final rinse sterile water The double-stage microbiological filtration system not only secures the validated disinfection of process water for the final rinse phase, it also disinfects the amount of water needed for the whole cycle, so that the spread of germs from the site water supply in the endoscope reprocessor is totally excluded. Filters performances of are continuously checked providing maximum security. Filters are decontaminated during the thermal self-disinfection program of the machine thus guaranteeing a long time service life. Both filters are approved medical devices. 10
11 EW 2 - Control panel The most advanced controller, the easiest interface, the safest system. The EW2 is controlled by a last generation PLC which communicates with a redundant system of probes for temperature control, chemical dosing and water consumption. For additional functioning security it is foreseen a second electronic board. A 5,7 touch screen panel lets the operator interface. The system access is protected by a 3 levels password (installer - maintenance technician - final user) and requests operator identification to enable the washing cycle programming or their own start. The software manages a database of endoscopes. At the first start of the machine the technician associates to each instrument the relevant elements for its identification, i.e. manufacturer, type, model and the parameters related to flow and pressure, number of active channels, pump functioning mode. The standard features of the EW2, and the optional bar code reader or RFID sensors avoid the risk of human error for the identification and selection of the disinfection program. The startup screen of the cycle is simple and, in case of automatic recognition of the instrument, the cycle start is almost immediate. The graphic interface is very similar to the drying and storage cabinet one as well as to the Steelcodata software one. From when the cycle is started the progress of the cycle will graphically be shown and the parameters referred to time remaining for phase and cycle completion will be displayed. or During the instrument reprocessing cycle, the EW2 display allows the visualization of: General state of functions Active parts Temperature trend and leak test Selection of the 4 synoptic for the visualization in real time of sensitive parameters such as channel active pumps, channel flows, channel pressures, temperature, etc. All parameters are recorded for later processing and storage. The Steelcodata software and the Steelco medical devices control panel interface are available for the mainly spoken worldwide languages: English, French, Spanish, German, Dutch, Italian... 11
12 ED Drying and storage cabinets for endoscopes After being reprocessed in the EW 2, the endoscope is ready to be used or to be stored in the ED series drying cabinets which protects endoscopes from any recontamination. Warm sterile air is used to blow through each internal channel and over all surfaces to rapidly dry both the inside and outside of the flexible endoscopes while they are in the cabinet. This ensures that endoscopes are well ventilated at all times. The endoscope internal channels are connected to the drying circuit through specific quick connectors. Up to 8 endoscopes can be stored at a time in cassettes or in baskets with lower trays for water dripping. The process allows the storage of endoscopes up to 72 hours after full washing and reprocessing with no need to reprocess them again. Steelco ED drying cabinets can be fitted with a bar code reader and printer for logging scopes in and out ensuring full tracking and traceability of the scopes. ED200 PLC version with touch screen display - Model, instrument code and position into the cabinet are displayed. - Interlocked doors controlled by PLC (double door passthrough version). - Events and cycle data storage for each instrument treated, for all machines parameters. - Process print. - Ethernet connection for PC data storage or Steelcodata. - Working cycles can be programmed. ED 200 is also available with 8 endoscopes horizzontally placed inside baskets with lower trays for water dripping. 12
13 ED Physical characteristics - Capacity: 8 endoscopes stored into cassettes 540 mm width x 500 mm depth (21.26 x 19x68 ). - Supplied as standard version with n 8 cassettes and endoscope fast connections. - Door made in HST temperate glass. - Frame and panels in stainless steel AISI Glass lockable doors are reversible and therefore can be configured right or left opening also during installation. - Single and double door (pass through) versions with control panel controlled locking. - High level HEPA H14 air filtering. - Indirect UV air treatment. Colour-coded cassettes with cover for the transport and the storage of the instruments. Main optional features - Cabinet configured with 8 net baskets with lower trays for water dripping - Compact frame combining two devices into a single unit - Integrated printer ST3 - RFID sensor for instrument/operator recognition - Bar code reader for instrument/operator recognition - Indirect UV drying air treatment Connection system cassette/cabinet and cassette/endoscope. Storage for large endoscopy centres Endoscope storage is a big issue for large endoscopy centres with high instrument throughput. Storage space saving is a must and a great advantage. The ED 200 can be configured in a more compact frame that combines two devices into a single unit with central control module. In an installation width of only 1672 mm / 65.82, up to 16 flexible endoscopes can be simultaneously dried and stored. Compared to conventional vertical storage the horizontal storage capacity is increased significantly and material damage caused by stretching of the endoscope external surface is avoided. Capacity comparison: vertical & horizontal storage typical vertical storage type cabinet footprint Steelco ED 100 Steelco ED 200 Steelco ED 200 equipped with compact frame combining two devices into a single unit 6/7X 8/9X 8X 16X 13
14 Connections Standard electrical connection (international) Optional electrical connection (North America)* Power (each storage cabinet unit) Noise Permitted room temperature * other electrical connections also available as optional 1672mm/ mm/ mm/ V/~/50Hz 110V/~/60Hz 2000 W < 48.5 db(a) +5 C/41 F C/104 F 785mm/ mm/ mm/ mm/ mm/ mm/ mm/ mm mm mm/74.80 loading Side 40mm mm 3.94 four doors pass through version double door version 1900mm/ mm/ mm/27.56 loading Side double door pass through version single door version 420mm Ø40mm mm Dimensions Weight 40mm mm /380 Kg 14
15 ED Drying and storage cabinets for endoscopes Characteristics - Capacity: up to 9 endoscope net baskets 460 mm width x 520 mm depth (18.11 x ). With lower tray for water dripping. - Supplied as standard version with 8 net baskets and 8 fast air connections for endoscope instruments. - Frame and panels in stainless steel AISI Door made in HST temperate glass. Glass lockable doors are reversible and therefore can be configured right or left opening also during installation. - Single or double interlocked doors pass through versions. Double door version opening depends on control panel. Single door version can be key locked. - High level HEPA H14 air filtering - 3 programmable cycles Main optional features - Indirect UV air treatment - Integrated printer ST2 - Cabinet equipped with 9 shelves and cabinet/endoscope connections Dimensions and connections Standard electrical connection (international) Optional electrical connection (North America)* Total power Noise Permitted room temperature Weight * other electrical connections also available as optional 230V/~/50Hz 110V/~/60Hz 1850 W < 45 db(a) +5 C/41 F C/104 F 187 Kg 710mm/ mm/ mm/ mm/ mm/ mm/26.97 Cabinet/endoscope CPC fast connection system mm/ mm/ mm/ mm/ mm/ mm/ mm/ mm/ mm/ mm/53.94 Universal endoscope channel connectors are provided for every cabinet level. loading Side double door pass through version 15
16 Process planning and safety aids In order to maintain a correct flow through the process, it is important to create the right environment. Steelco ARES system foresees the use of storage cassettes and a transport trolley in order to maintain the right dirty/clean flow with considerable advantage in terms of process safety. In case the disinfection area is serving multiple endoscopes rooms, the use of the endoscope transport trolley for an aseptic movement is an additional safety aid and grants short-term safe storage improving the department productivity. C 256 Transport and short time storage of contaminated/disinfected endoscopes and accessories Transport trolley on wheels with capacity of 4 cassettes. It is completed with bag holder with red and white bags for dirty or clean instruments. Made of stainless steel it can also be used as a support for the endoscopes. 650mm/ mm/ mm/ mm/37.01 Dimensions Weight 45 Kg 16
17 ARES - Way from dirty area to clean area with hygienic bags use High safety procedure 1 Prepare an empty container 2 Put the red bag in the container 3 Put the endoscope in the container 1 4 Close the red bag with the handles 5 Close the lid and turn the switch to red 6 Washing and disinfecting endoscopes 2 7 Prepare an empty container 8 Put the white bag in the container 9 Put the disinfected endoscope in the container 10 Close the lid and turn the switch to green endoscope reprocessing 17
18 Steelcodata - Data management and remote monitoring of the devices Main Features > Steelcodata is a powerful software package with a very easy and complete operator interface. Its aim is mainly to visualize the running cycles, to easily manage and store the information generated by other devices configured in the system and allows also the immediate remote monitoring of the machines. It is available for Windows and the connection is made through the Ethernet in order ensuring full transparency and compatibility with the customer resources, keeping all the cycle data stored for legal purposes and for statistics visualization. [063-Cycle Data] Factory type number: Address: Start cycle date: Start cycle time: End cycle date: End cycle time: Work Order Code: MM PLC Cycle number: 3 - CICLO STANDARD PLC Operator: CARINO INES Result: 1 - Cycle OK Machine Cycle: 877 Instrument 1: 18 - MAT Instrument 2: 5 - MAT :25:48 026,5 026,5 032, :25:52 026,7 026,6 032, :25:56 026,5 026,6 032, :26:00 026,7 026,6 032, :26:04 026,7 026,7 032, :26:08 026,8 026,7 032, :26:12 026,8 026,7 032, :26:16 026,8 026,7 032, :26:20 026,8 026,7 032, :26:24 026,8 026,8 032, :26:28 026,9 026,8 032, :26:32 026,9 027,0 032, :26:36 027,0 027,0 032, :26:40 027,0 027,0 032, :26:44 027,0 027,2 032, :26:48 027,2 027,2 032, :26:52 027,0 027,3 032, :26:56 027,3 027,3 032, :27:00 027,3 027,3 032, :27:04 027,3 027,5 032, :27:08 027,3 027,5 032, :27:12 027,5 027,5 032, :27:17 027,5 027,5 032, :27:20 027,5 027,5 032, :27:24 027,5 027,6 032, :27:28 027,7 027,6 032, :27:33 027,8 027,8 032, :27:36 027,7 027,6 031, :27:40 027,7 027,6 031, :27:44 027,7 027,6 031, :27:48 027,7 027,8 031, :27:52 027,8 027,8 031, :27:56 027,8 027,8 031, :28:00 027,8 027,8 031, :28:04 027,8 027,8 031, :28:08 028,0 027,9 031, :28:12 028,0 027,9 031, :28:16 028,0 027,9 031, :28:20 028,0 028,1 031, :28:24 028,1 028,1 031, :28:28 028,1 028,2 031, :28:32 028,1 028,2 031, :28:36 028,3 028,2 031, :28:40 028,4 028,9 032, :28:44 029,1 029,4 032, :28:49 029,7 029,9 032, :28:52 030,1 030,3 032, :28:56 030,5 030,8 032, :29:00 030,8 031,1 032, :29:05 031,1 031,4 032, :29:08 031,4 031,7 032, :29:12 031,8 032,0 032, :29:16 031,9 032,2 032, :29:20 032,1 032,3 033, :29:24 032,2 032,4 033, :29:28 032,2 032,4 033, :29:33 032,2 032,6 033, :29:36 032,4 032,4 033, :29:40 032,4 032,6 033, :29:44 032,4 032,4 033, :29:49 032,4 032,4 033, :29:52 032,4 032,4 033, :29:56 032,4 032,4 033, :30:00 032,4 032,4 033, :30:04 032,4 032,4 033, :30:08 032,4 032,4 033, :30:12 032,4 032,4 033, :30:16 032,4 032,4 033, :30:20 032,5 032,4 033, :30:25 032,5 032,4 033, :30:28 032,5 032,4 033, :30:32 032,5 032,4 033, :30:36 032,5 032,4 033, :30:41 032,5 032,4 033, :30:44 032,5 032,4 033, :30:48 032,5 032,4 033, :30:52 032,5 032,4 033, Complete storage of the registered data > Every 4 seconds the Steelcodata collects all the registered records from each device and processes them by providing visual information summary which can immediately be interpreted by the operator. All data even if not visualized on the summary display will be available for local back up or remote back up into the hospital server. In the event of any connection interruption with the server, the devices can continue to operate and all the records will be automatically transferred when the communication will be restored. Cycle consumptions and statistic functions > Specific screens are dedicated to the information on cycle consumption of water, chemical products and to the alarm history. Steelcodata can work simultaneously with several opened windows thus allowing an immediate visual comparison of the data and charts from different machines. A specific menu is dedicated to statistical functions in order to search and control cycles and reprocessed instruments. It is possible to search for instrument serial numbers or for process identification number. Information security > The Steelcodata software makes accessible to the operator the main data of the executed washing cycles, of times and storage of the endoscopes (available with the ED 200 Steelco drying cabinets only), allowing to select and export them in 2 different formats, one that cannot be modified and usable only for legal reasons, and the other one for compatibility to other management and tracebility systems. Steelcodata allows to print on adhesive labels which can be easily applied on the patient documentation or to use a normal A4 page printer. 18
19 ARES - SteelcoData control system devoted to hygiene Steelcodata control system was created to meet the need of traceability and phase control, both manual and automatic, in order to avoid any human error and assure the use of only correctly disinfected and not contaminated instruments on patients. The validation print out document provides an absolute guarantee that the instrument reprocessing has been done successfully and all the cycle information is supplied for full traceability. 7 remote technical assistance in order to reduce maintenance intervention time and costs. Steelcodata & Radio Frequency Identification 6 validation print out on paper or label for the patient dossier Record instrument recognition operator recognition patient recognition doctor recognition 2 Record EW2 EW2 serial number date time position start-end phases sensor parameters leak test events channel pressure channel flow 3 Record ED200 sn date time position start-end phases events sensor parameters 4 Record PC data transfer on PC or hospital main server cycle, chemical and water statistics cycle visualization during execution 19
20 For the Environmentally conscious For the Environmentally conscious For the Environmentally conscious For the Environmentally conscious For the Environmentally conscious For the Environmentally conscious Headquarter STEELCO S.p.A. Via Balegante, Riese Pio X (TV) - Italy Ph Fax [email protected] Branches STEELCO HUNGARY Temesvár u., Budapest - Hungary Ph Fax [email protected] Laboratory glassware washer disinfectors Laboratory glassware > washing system Dental washer disinfectors devoted to hygiene devoted to hygiene Washer disinfectors > animal cages and feeding bottles Dental washer disinfectors STEELCO USA 999 Stinson Way - Unit 301 West Palm Beach, FL USA Ph Fax [email protected] Flusher disinfectors > for hospitals and nursing houses devoted to hygiene devoted to hygiene Flusher disinfectors Pharmaceutical washing-systems Washer disinfectors > Small - Medium range Pharmaceutical washing systems Washer disinfectors > CSSD Range - Systems and Automations For the Environmentally conscious devoted to hygiene Washer disinfectors for lifescience applications Washer disinfectors Small/Medium Range Washer disinfectors CSSD Range - Systems and Automations devoted to hygiene devoted to hygiene STEELCO ASIA 6th floor, Suite 16, IOI Business Park Persiaran Puchong Jaya Selatan - Bandar Puchong Jaya Puchong, Selangor - Malaysia Ph (Ext. 112) - Fax: [email protected] 0051* * Only for products listed into the 909/MDD certificate DC-PD-02-ARES EN Rev.04 Products offered for sale may differ from those described or illustrated in this brochure due to later production changes or/and optional configurations. The products and technical specifications are subjected to change wihout prior notice. Please consult your Steelco dealer for the latest information.
Clinic Washer-Disinfectors. Washer-Disinfector Line
Clinic Washer-Disinfectors Washer-Disinfector Line Easy-to-Use Washer-Disinfectors for Clinics The Clinic Range of Washer Disinfectors provides superior cleaning and disinfection combined with innovative
Company background and. portfolio overview
Company background and portfolio overview A world leading company in infection control Steelco products are used daily in over 100 countries within the Healthcare, and Life Science sectors to provide the
A new wave in instrument washing and disinfection Introducing the new HYDRIM G4 WD series
A new wave in instrument washing and disinfection Introducing the new HYDRIM G4 WD series Taking control of your infection control The hazards of manual cleaning Hand scrubbing is increasingly used less
ETD3 the new standard in endoscope reprocessing.
Endoscope Reprocessing ETD3 Automatic Endoscope Reprocessor ETD3 the new standard in endoscope reprocessing. 2 The standard in endoscope reprocessing: The Olympus ETD3. The Olympus ETD system has become
FVA/A1 saturated-steam sterilizer
FVA/A1 where technology innovation and design come together FVA/A1 saturated-steam sterilizer www.fedegariautoklaven.ch Fedegari's new FVA/A1 series of automatic vertical sterilizers has been expressly
Freezers - Ultrafreezers. Platilab & Irilab Series
Freezers - Ultrafreezers Platilab & Irilab Series PLATILAB: top security and performances with reliable temperature control. IRILAB: combining the high reliability of PLATILAB with the possibility to store
Hospital Sterilizers. T-Max Line
Hospital Sterilizers T-Max Line Hospital Sterilizers Sterilization is a complex process. Like any complex process, many things can go wrong. A Hospital depends on its CSSD: Central Sterile Services Department.
Horizontal Steam Sterilizers. Healthcare Line. Since
Horizontal Steam Sterilizers Healthcare Line Since 1925 Horizontal Steam Sterilizers for Healthcare Applications The Tuttnauer line of healthcare sterilizers are designed for hospital operating rooms,
LABOKLAV. Autoclaves Made in Germany. www.shp-steriltechnik.de
LABOKLAV Autoclaves Made in Germany www.shp-steriltechnik.de 2 LABOKLAV STEAM STERILIZERS Steam sterilization is the sterilization method with the widest range of applications efficient, safe, reproducible
Laboratory & Scientific Line. Bulk Steam Sterilizers. Since
Laboratory & Scientific Line Bulk Steam Sterilizers Since 1925 Bulk Steam Sterilizers for Laboratory & Scientific Applications The Tuttnauer line of bulk autoclaves are designed to handle the most critical
data sheet DONATELLO Rev. I emiss - 25/10/2013 52PRO03 code Automatic tissue processor DONATELLO
Rev. I emiss - /0/0 DONATELLO Automatic floor closed cycle processor for histological specimens Automatic tissue processor DONATELLO code PRO0 General characteristics DONATELLO is a closed cycle processor
EcoCWave. The all-round talent for aqueous part cleaning. www.durr.com
EcoCWave The all-round talent for aqueous part cleaning www.durr.com Part cleaning as a value-adding value-adding process process Increasing demands on cleanliness in component manufacturing impose a need
ORGANIC SAMPLE PREPARATION
ORGANIC SAMPLE PREPARATION W W W.LA BT E C H S R L.CO M WSPE MANUAL VACUUM MANIFOLD SPE Process control of the flow rate is critical to guarantee reproducible extractions. Differently then any other systems,
OT 40L / 90L. Laboratory Steam Sterilizers
OT 40L / 90L Laboratory Steam Sterilizers OT 40L / 90L LABORATORY STEAM STERILIZERS OT 40L / OT 90L laboratory steam sterilizers are specially designed for the steam sterilization of liquid and culture
LyoBeta. R+D Freeze-Dryers
LyoBeta R+D Freeze-Dryers LyoBeta series A Responsible Choice New demands in R+D centers are related to scale-up feasibility and quality of procedures and research methods. FDA investigators consider that
Tabletop Line. Automatic and Semi-Automatic Autoclave Series
Tabletop Line Automatic and Semi-Automatic Autoclave Series Tuttnauer Your Sterilization & Infection Control Partner Company Profile For over 80 years, Tuttnauer s sterilization and infection control products
FVA THIRD-GENERATION VERTICAL SATURATED-STEAM STERILIZERS
The key difference between a small vertical or bench-top sterilizer and industrial sterilizer is performance. Small saturated-steam sterilizers with vertical or horizontal chambers were devised many years
MELA quick 12+ Compact. Fast. Strong.
MELA quick 12+ Compact. Fast. Strong. The requirement. Requirements for the preparation of dental instruments are defined by official hygiene experts. Instruments for semicritical use (restorative treatment)
Christina Bradley Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK
Christina Bradley Hospital Infection Research Laboratory Queen Elizabeth Hospital Birmingham, UK Inadequate decontamination procedures and equipment malfunction were two leading causes of post endoscopic
How To Control A Medical Device With A Pc System
Clean room monitoring and disinfection FMS 5.0, the Leading Facility Monitoring Software TSI FMS system is an advanced, reliable, and user-friendly monitoring software suite that features a truly open
National Endoscopy Programme. Decontamination Standards for Flexible Endoscopes
National Endoscopy Programme Decontamination Standards for Flexible Endoscopes Updated March 2009 Introduction Providing an effective endoscope decontamination service within a safe environment is an essential
Refrigerators - Freezers. Ekofrigolab & Ekobasic Series
Refrigerators - Freezers Ekofrigolab & Ekobasic Series Angelantoni Life Science S.r.l. manufactures a wide range of refrigerated cabinets and combined refrigerator/freezer cabinets. We offer high reliability
Vacuum drying oven for non-flammable solvents
VD series 53 Vacuum drying ovens Vacuum drying oven for non-flammable solvents A BINDER vacuum drying oven of the VD series is impressive while gently drying with its homogeneous temperature distribution.
T 300 Tray sealer. Automatic tray packaging in the smallest of spaces
T 300 Tray sealer Automatic tray packaging in the smallest of spaces MULTIVAC T 300 T 300 Tray sealer: Automatic tray packaging in the smallest of spaces The especially compact T 300 tray sealer packs
Air Shower Biosafety Changing Station with Pass-Through Box Pass-Through Box Automatic atomizer for no-contact hand disinfection
Air Shower Biosafety Changing Station with Pass-Through Box Pass-Through Box Automatic atomizer for no-contact hand disinfection A wide range of products to meet the needs of transferring animals, operators,
Visions become real. Temperature control and cooling systems. The innovative and reliable solution
Temperature control and cooling systems The innovative and reliable solution With our PulseTemp equipment you have the option of up to 72 cooling circuits in the impulse cooling, temperature control, temperature
German engineering under high pressure
German engineering under high pressure Over 25 years of experience as a manufacturer of sterilizers, autoclaves and lyophilization systems for laboratories, production and research Production-scale autoclaves
Medical Waste Autoclaves. Medical Waste Autoclaves
Medical Waste Autoclaves Medical Waste Autoclaves Safe, Cost-Effective, Medical Waste Sterilization Treat Medical Waste with high performance Tuttnauer Medical Waste autoclave systems designed for small,
Cooking at the Speed of light!
Cooking at the Infrared Cooking & Colouring Infrabaker is a modular infrared continuous cooking system developed by Infrabaker International. The machine is designed to cook and/or put colour on a wide
Customer: Cardiff Hospital NHS (United Kingdom) Machine:
Customer: Cardiff Hospital NHS (United Kingdom) Machine: Bench for leak test Model: Easy TS Page 1 of 7 Date: 6 th March 2012 1. Introduction. Easy TS is a compact and reliable table top bench designed
Why do our customers make their choice for PMT Partners Medische Techniek BV?
Why do our customers make their choice for PMT Partners Medische Techniek BV? Company presentation 2014 CONTENT Description Page Introduction... 3 Why the choice for PMT Partners Medische Techniek BV?...
Sterilizers with extra class
Sterilizers with extra class ClassB Ready for the future The European standard EN 13060 specifies the performance requirements and test methods for small steam sterilizers. These are used for hygiene and
MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM. Key features: NOVAIR quality and service: www.novairmedical.com
MEDICAL AIR STATIONS FOR MEDICAL GAS PIPING SYSTEM Designed for centralized medical air production in hospitals and clinics, NOVAIR medical air stations ensure the continuous supply of the medical gas
SITE REQUIREMENTS AND INSTALLATION INSTRUCTIONS
ADVANTAGE PLUS SITE REQUIREMENTS SITE REQUIREMENTS AND INSTALLATION INSTRUCTIONS 50096-927 Rev A For additional information contact your Medivators Pg 1 of 18 SITE REQUIREMENTS The purpose of this section
GETINGE GEB SERIES BIOSAFETY STERILIZERS SAFE, RELIABLE DECONTAMINATION IN BIOCONTAINMENT FACILITIES. Always with you
GETINGE GEB SERIES BIOSAFETY STERILIZERS SAFE, RELIABLE DECONTAMINATION IN BIOCONTAINMENT FACILITIES Always with you 2 Getinge GEB Sterilizers LIGhTS ON FOR ThE NEw GENERATION STERILIZERS The new Getinge
Laboratory Line. Vertical and Bench-Top Life Science Autoclaves
Laboratory Line Vertical and Bench-Top Life Science Autoclaves The Advanced Laboratory Line The Full Spectrum of Laboratory Sterilizers Sterilization in a laboratory environment has its unique requirements.
Laminar Flow Cabinets
Laminar Flow Cabinets The World s Most Practical Selection of Benchtop Laminar Flow Cabinets. 24 36 48 Simple, Effective Protection for Samples and Work Processes, Uncompromised Performance, Economical
Please also see 10 golden rules for correct Saniflo installation on www.saniflo.co.uk
1. Description Sanicom is a lifting pump for wastewater used in commercial applications (restaurants, hairdressing salons, the catering industry etc.). The unit operates automatically, has a high performance
Equipment Information
3002A Equipment Information INDEX: DESCRIPTION AND KEY FEATURES LAYOUT NOMINAL TECHNICAL DATA CONFIGURATION Sealed Air GmbH Customer Systems Center D4 Park 4 CH-6039 Root-Längenbold Telephone: +41 (0)
Vertical and Benchtop Autoclaves for Life Sciences. Laboratory Line
Vertical and Benchtop Autoclaves for Life Sciences Laboratory Line Designed for Your Laboratory Applications Advanced Laboratory Autoclaves Tuttnauer laboratory autoclaves have been designed to provide
TRIMMING TECH 150. IVD In vitro diagnostic-medical device. General information. Technical datasheet Trimmingtech150
IVD In vitro diagnostic-medical device CND code: W0202059016 - CIVAB code: TRIMMING TECH 150 General information Type of instrument: Aspirated hood for histology. Model: Trimming Tech 150. Code: Description:
Power consumption (kw)
OS Series Series description LIT OS systems are applied to wastewater disinfection. The models of this series were developed on base of high-efficiency low-pressure amalgam lamps and have all components
Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO
Rotary screw compressors kw 5,5 7,5 11 15 18,5 22 30 bar 8 10 13 15 MODULO The sum of technology TriAB Air ends The BALMA screw compressors are fitted with the unique TriAB air ends that are designed and
ECOCIAT. Domestic hot water heat recovery unit
Heat recovery unit Domestic hot water High energy efficiency with R410A Compact and quiet Scroll compressors Brazed-plate heat exchangers Heating Heat recovery ENVIRONMENTALLY HFC R410A PROTECTION DE FRIENDLY
BSL3 and BSL4 Autoclaves. Laboratory Line
BSL3 and BSL4 Autoclaves Laboratory Line BSL3 and BSL4 Autoclaves In today s society the need for safe bio-containment systems is increasingly important. This is especially true in the sterilization process
Order Code for GEA Tuchenhagen VESTA Sterile Valves. Type H_A 2/2 Way Seat Valve
Order Code for VESTA Sterile Valves Type H_A 2/2 Way Seat Valve engineering for a better world GEA Mechanical Equipment VESTA Sterile Valves are designed for universal use in sterile process technology.
SunMaxx Solar Filling Station Operating Instructions
SunMaxx Solar Filling Operating Instructions Content 1. Declaration of conformity... 2 2. Introduction... 2 3. Transportation and unpacking... 4 4. Mounting and commissioning... 5 5. End of operation...
Laboratory- and sterilisation equipment HMC EUROPE
Laboratory- and sterilisation equipment HMC EUROPE PROFILE HMC EUROPE Laboratory- and sterilisation equipment Consistent marketing of technologies and the conversion of new ideas create product ranges,
INNOVATION TO MEET YOUR NEEDS
INNOVATION TO MEET YOUR NEEDS 100% High Throughput The throughput is optimized splitting the pipetting phases of Reagents and Samples into different cycles. The innovative technical solutions adopted by
Partnership. Medical Waste Autoclaves. Medical Waste Autoclaves
Partnership Medical Waste Autoclaves Medical Waste Autoclaves Safe, Cost-Effective, Medical Waste Sterilization Keep your environment safe from Medical Waste with high performance Tuttnauer Medical Waste
STEAM STERILIZERS. DLOV & DLOM series. more than fifty years of experience in sterilization. DE LAMA s Quality Management System is certified:
STEAM STERILIZERS DLOV & DLOM series DE LAMA s Quality Management System is certified: more than fifty years of experience in sterilization UNI EN ISO 9001:2000 - Cert. n 0351 UNI EN ISO 13485 - Cert.
EcoStar Professional warewashing with integrated effi ciency and hygienic reliability
Professional warewashing technology EcoStar Professional warewashing with integrated effi ciency and hygienic reliability EcoStar-Line Product range www.meiko.de EcoStar-Line Step up and start washing
ADU 5. Automatic Distillation Unit
ADU 5 Automatic Distillation Unit Atmospheric Distillation Distillation tests are used to characterize the volatility of petrochemical products. These volatility characteristics are a critical measurement
Benchmark. WASH l RINSE l PASSIVATE l DRY. Benchmark Precision Aqueous Cleaning Systems Modular Design, Superior Clean, Unwavering Service
Benchmark WASH l RINSE l PASSIVATE l DRY Benchmark Precision Aqueous Cleaning Systems Modular Design, Superior Clean, Unwavering Service The Standard By Which All Others Are Judged The Branson Benchmark
WIBObarrier OCS - Open Containment Systems WIBObarrier CCS - Closed Containment Systems
WIBOjekt and WIBObarrier Air Curtain Systems. The perfect protection for person, product and environment. Filling Weighing Sampling Research Safe handling with high potent products / API WIBObarrier OCS
Mitos P-Pump. product datasheet
product datasheet page Product description 2 Main benefits 3 Why choose the Mitos P-Pump? 3 Closed-loop flow control 4 Product specifications 5 Accessories - overview 6 Mitos P-Pump Basic 7 Mitos P-Pump
LAMINAR FLOW FOR ALL YOUR NEEDS
LAMINAR FLOW FOR ALL YOUR NEEDS 2 LAMINAR FLOW FOR ALL YOUR NEEDS EXPLORE TECNIPLAST COMPLETE RANGE OF LAMINAR FLOW SOLUTIONS: OUR CUTTING-EDGE TECNOLOGY IS AT YOUR SERVICE, TO ASSURE TOP ENVIRONMENTAL,
CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60
CoolTop A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60 Application CoolTop is a new, unique air conditioning unit especially designed for datacenters.
Spetec. Laminar Flow Box. Portable Clean Room Technology
Spetec Laminar Flow Box Portable Clean Room Technology 1 Fundamentals Portable Clean Room Technology Laminar Flow The basis for the development of the clean room technology was first established in the
UV Disinfection Systems A Series. Main Applications: Drinking Water, Process Water, Warm Water / Legionellae. IT T Industries Engineered for life
DIN EN ISO 9001 DIN EN ISO 9001 DIN EN ISO 14001 UV Disinfection Systems A Series Main Applications: Drinking Water, Process Water, Warm Water / Legionellae DIN EN ISO 14001 UV Disinfection Systems A Series
FlowFAST V. Vertical Laminar Airflow Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.
Vertical Laminar Airflow Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE. Vertical Laminar Flow Cabinets BEYOND MINIMUM SAFETY REQUIREMENT Cabinets are ISO Class 3 vertical laminar flow cabinets which
Expert Opinion. on the efficacy of. EndoDet and EndoDis + EndoAct. for cleaning and disinfection of. Olympus Gastroscope Type GIF-2T200.
Expert Opinion on the efficacy of EndoDet and EndoDis + EndoAct for cleaning and disinfection of Olympus Gastroscope Type GIF-2T200 with the Endo Thermo Disinfector ETD3 tested according to the recommendations
Alfa Laval PureBallast 3.1
Alfa Laval PureBallast 3.1 Ballast water treatment system 1000 m 3 /h system Alfa Laval PureBallast 3.1 is an automated inline treatment system for the biological disinfection of ballast water. Operating
W&H Sterilizers. Made-to-measure precision and perfection. Totally type B
W&H Sterilizers Made-to-measure precision and perfection Totally type B The brilliance of know-how A technical leap has been achieved: Lisa has become fully automatic. At the forefront of modern dentistry,
QFP910. Water detector. Building Technologies. CE1N2732en 2016-03-01. Synco living
2 732 Synco living Water detector QFP910 Wireless radio sensor to record water puddles RF communication based on KNX standard (868 MHz unidirectional) Battery operation with standard 1.5 V batteries Use
BENCH TECH 150. IVD In vitro diagnostic-medical device. General information Type of instrument: Bench chemical hood. Technical datasheet BenchTech150
IVD In vitro diagnostic-medical device CND code: W0202059016 - CIVAB code: BENCH TECH 150 General information Type of instrument: Bench chemical hood. Model: Bench Tech 150. Code: 50-150-201 Description:
LAMINAR FLOW CABINETS
LAMINAR FLOW CABINETS Vertical Laminar Flow Cabinets VLF 550 VLF650 VLF1000 VLF1200 VLF 1500 VLF1800 Monmouth Scientific's brand new range of Vertical laminar Flow (VLF) cabinets is available in six different
Cliniklav 25. For highest quality in surgical applications MELAG. Evidence Based Sterilization
Cliniklav 25 For highest quality in surgical applications MELAG Evidence Based Sterilization Cliniklav 25 The big one from MELAG a powerful piece of technology Built-in printer for documenting program
Laboratory & Scientific Line. Horizontal Steam Sterilizers
Laboratory & Scientific Line Horizontal Steam Sterilizers Horizontal Steam Sterilizers for Laboratory & Scientific Applications Sterilization in a laboratory environment has its unique requirements. The
Material test chamber with mechanical convection
FP series 400 Material test chambers Material test chamber with mechanical convection A BINDER material test chamber with mechanical convection of the FP series provides reliably short drying times and
Large Steam Sterilizers for the Life Sciences. Laboratory Line
Large Steam Sterilizers for the Life Sciences Laboratory Line Large Steam Sterilizers for the Life Sciences Sterilization in a laboratory environment has its unique requirements. The types of loads that
MINIMAT-EC-Servo Screwdriver Spindles
Screwdriving technology Automation Air motors Air tools Screwdriver Spindles electric MINIMAT-EC-Servo Screwdriver Spindles Maximum Flexibility and process Control Straight Spindle Form - Torque range
GETINGE GEW cgmp WASHER/DRYERS SECURING CRITICAL CLEANING IN THE MANUFACTURING ENVIRONMENT
GETINGE GEW cgmp WASHER/DRYERS SECURING CRITICAL CLEANING IN THE MANUFACTURING ENVIRONMENT 2 Getinge GEW cgmp EXPERIENCE TO RELY ON Getinge is uniquely capable of offering you complete sterile systems.
Thermo Scientific VARIOKLAV Modular Laboratory Autoclaves Versatile, space-saving performance for steam sterilization applications
Thermo Scientific VARIOKLAV Modular Laboratory Autoclaves Versatile, space-saving performance for steam sterilization applications Part of Thermo Fisher Scientific Thermo Scientific Varioklav Laboratory
GETINGE GEW 2100LS CAGE AND RACK WASHER PREVENTING CONTAMINATION IN ANIMAL CARE
GETINGE GEW 2100LS CAGE AND RACK WASHER PREVENTING CONTAMINATION IN ANIMAL CARE GETINGE GEW 2100LS Cage and Rack Washer - Preventing contamination in animal care 3 CLEAN CAGES, RACKS AND BOTTLES WITH
GETINGE AER RANGE A SAFER WAY TO REPROCESS ENDOSCOPES. Getinge AER Range 1
GETINGE AER RANGE A SAFER WAY TO REPROCESS ENDOSCOPES Getinge AER Range 1 2 Getinge AER Range ENDOSCOPE REPROCESSING FAST AND ERROR-PROOF As the use of endoscopes increases, so does the risk of infections
Product overview Air conditioning service units
Product overview Air conditioning service units 02 03 AIR CONDITIONING SERVICE UNITS FROM ROBINAIR ARE THE WORLD S MOST ADVANCED AND MOST POPULAR AIR CONDITIONING SERVICE UNITS FOR CARS; TRUCKS AND BUSSES.
GetinGe 88-SerieS WaSher DiSinfectorS
CUSTOMER:... REFERENCE:... GetinGe 88-SerieS WaSher DiSinfectorS ProDuct SPecification ProDuct The Getinge 88-Series (GETINGE 88 TURBO) is a fully automatic, microprocessor controlled, Washer Disinfector
Vakulab PL. All-rounder for laboratory and research. Long life time and short cycle times. Space saving and ergonomical
Vakulab PL All-rounder for laboratory and research Long life time and short cycle times Space saving and ergonomical Model diversity and tailored to specific application MMM. Protecting human health. Vakulab
GETINGE CLEAN MANAGEMENT SYSTEM
GETINGE CLEAN MANAGEMENT SYSTEM 2 Getinge Clean Management System GETINGE CLEAN MANAGEMENT SYSTEM (CMS) AN IMPROVED PROCESS, A UNIQUE SOLUTION Getinge can help you manage your detergents and reduce costs.
VDL 53 - Vacuum drying oven for flammable solvents
Vacuum drying ovens VDL 53 - Vacuum drying oven for flammable solvents The VDL series ensures maximum safety when drying organic solvents in accordance with TÜV/GS guidelines. The interior chamber is designed
OPSIS LiquidLINE KjelROC Distillation Unit
OPSIS LiquidLINE KjelROC Distillation Unit Distillation System with Unique Level of Serviceability and Automation LP 1002 Why KjelROC Distillation Unit? In many tests there is a need to separate the substance
Heating oven with mechanical control
ED series 53 Drying ovens / Heating ovens Heating oven with mechanical control The strength of the BINDER ED series heating oven: routine drying and sterilization applications up to 300 C (572 F). Thanks
OPL BASIC. Dosing System for Professional Laundry machines. Contents
OPL BASIC Dosing System for Professional Laundry machines Contents 1 Getting Started. Page 2 2 Installation. Page 4 3 Set Up & Operation. Page 8 4 Maintenance & Accessories. Page 10 5 Troubleshooting Page
Model Voltage (V/Hz) Power (W) Capacity (L) Chamber size Outside size(mm) Weight (kg) STE-TEN 220/50 1100 1 Ø90x160mm W200xH385xD450 30 (Net:28)
Table Top STE-TEN STE-TEN, 1 Liter Autoclave It adopts B-wclass (pred-13060), with 3-times pre-vacuum preceding vacuum drying. Residual humidity is 0.2, vacuum measurement reaches -0.7bar. It sterilizes
TELESCOPE Motorized Lighting Suspension
TELESCOPE Motorized Lighting Suspension Mod. 8400 FEATURES The De Sisti TELESCOPE is a single point suspension specifically designed to provide rigidity and stabilization of all moving parts. It can extend
The Premium-Plus-Class Now even better
The Premium-Plus-Class Now even better Innovation and quality the philosophy of a family-run business As an owner-run and operated family concern founded in 1951, we have a long history of successful specialization
ThermoStar Refrigeration Air Dryers
ThermoStar Refrigeration Air Dryers Why dry compressed air? Contamination Reduces Efficiency The air we breathe contains contamination in the form of water vapour and airborne particles. These problems
ROTARY SCREW COMPRESSOR. RMD 30-37 - 45-55 kw
ROTARY SCREW COMPRESSOR RMD - - - 55 kw EN The RMD Coaxial Rotary Compressor high reliability high performance low maintenance is the result of decades of experience in manufacturing design and construction
ElastoFlake & ElastoTec
ElastoFlake & ElastoTec Relining Group 02 Revolutionally injection casting ElastoFlake, a new material from the Relining Group, is a polymer plastic mass intended for injection casting, which was developed
UNITOR VACUUM cleaners
UNITOR VACUUM cleaners Unitor VCD15 a compact, heavy-duty dry vacuum cleaner for accommodation areas The smallest unit in the Unitor range, the VCD15 is purpose-made for use on cruise and passenger vessels.
Heating oven with mechanical convection
FD series 53 Drying ovens / Heating ovens Heating oven with mechanical convection A BINDER FD series heating oven is always used when fast drying and sterilization is required. Thanks to its fully homogeneous
Modular Glovebox Systems Gas Purifier Units Antechambers Accessories
Modular Glovebox Systems Gas Purifier Units Antechambers Accessories INERTGAS TECHNOLOGY Modular glovebox with screwed in flanged side panels Easy to extend or modify while keeping a flat work place Define
MOBILE WATER TREATMENT FACILITY UMUV 01
MOBILE WATER TREATMENT FACILITY UMUV 01 January 10 Basic description of facility VODASERVIS s.r.o. UMUV 01 is a multi-purpose mobile water treatment facility which enables treatment from different sources
DV 270.2 Dynamic power from MEIKO s Premium Class
Dynamic power from MEIKO s Premium Class The universal dishwasher universal dishwasher: A supreme maid of all work with real cleaning power It has everything that makes it a true maid of all work. Dynamic
Kompressoren. Adsorption Dryer AD
Kompressoren Adsorption Dryer AD Adsorption Drying: why? Modern industries require compressed air that is increasingly filtered with low dew point and condensate. Today, the equipment is more sophisticated
Horizontal Sterilizer MU 012.B / I (09/07) Page 2/46. 1 Index... 2
0932 Horizontal Sterilizer MU 012.B / I (09/07) Page 2/46 1 Index 1 Index... 2 2 Description of the Inputs / Outputs... 4 2.1 Inputs / Module OMRON ID201 / ID211...4 2.2 Outputs / Module OMRON OC211...5
italtec PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines
PRINTED CIRCUITS EQUIPMENT PRINTED CIRCUITS EQUIPMENT Insulator machines Echting machines Special equipment and machines On customer request it is possible to supply: Benches for PCB Oven for PCB Chemicals
R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power
R22. K Control. Indoor Unit. Nomenclature. PL H 3 G K H B Compatibility Unit style Heat Pump Horse Power Control Boost Heaters R22. K Control. Outdoor Unit. Nomenclature. PU H 3 Y K A Compatibility Outdoor
helosauna.com STEAM BATH PRODUCTS
helosauna.com STEAM BATH PRODUCTS 2 STEAM BATHS 3 Steam bathing The joys of steam bathing have been known and appreciated for as long as sauna has existed. Romans understood the rewards of a rich moist