NEUTRON BASED TECHNIQUES FOR DETECTION OF ILLICIT MATERIALS AND EXPLOSIVES

Similar documents
Characteristics of an Integrated Germanium Detector Based Gamma-Ray Spectrometer for Monitoring Systems

Overview of Nuclear Detection Needs for Homeland Security. Abstract

Chapter NP-5. Nuclear Physics. Nuclear Reactions TABLE OF CONTENTS INTRODUCTION OBJECTIVES 1.0 NUCLEAR REACTIONS 2.0 NEUTRON INTERACTIONS

Cargo Container X-ray Inspection Systems

Gamma Rays OBJECT: READINGS: APPARATUS: BACKGROUND:

Activitity (of a radioisotope): The number of nuclei in a sample undergoing radioactive decay in each second. It is commonly expressed in curies

GAMMA-RAY SPECTRA REFERENCES

Atomic and Nuclear Physics Laboratory (Physics 4780)

Effect of Gamma Ray Energies and Addition of Iron Slag by weight to Portland Cements on Mass Attenuation Coefficient

WORLD CUSTOMS EXHIBITION AND FORUM, Budapest, th September 2003

A Comparison of an HPGe-based and NaI-based Radionuclide Identifier (RID) for Radioactive Materials

A VERSATILE COUNTER FOR CONVERSION MÖSSBAUER SPECTROSCOPY

ORTEC AN34 Experiment 7 High-Resolution Gamma-Ray Spectroscopy

Nuclear Physics. Nuclear Physics comprises the study of:

Lecture 2 Macroscopic Interactions Neutron Interactions and Applications Spring 2010

Cosmic Ray Muon Scattering Tomography for Security Applications

Basics of Nuclear Physics and Fission

Public Policy 290 Homeland Security / Cyber Security. Fall US program to address nuclear terrorism threats:

A Digital Spectrometer Approach to Obtaining Multiple Time-Resolved Gamma-Ray. Spectra for Pulsed Spectroscopy. W. K. Warburton a

MDCT Technology. Kalpana M. Kanal, Ph.D., DABR Assistant Professor Department of Radiology University of Washington Seattle, Washington

MONTE CARLO SIMULATION OF THE FULL MULTIPLICITY DISTRIBUTIONS MEASURED WITH A PASSIVE COUNTER

Radiation Strip Thickness Measurement Systems

13C NMR Spectroscopy

Radioactivity III: Measurement of Half Life.

Radiation Detection and Measurement

Tutorial 4.6 Gamma Spectrum Analysis

ON-STREAM XRF ANALYSIS OF HEAVY METALS AT PPM CONCENTRATIONS

Main properties of atoms and nucleus

Production of X-rays. Radiation Safety Training for Analytical X-Ray Devices Module 9

Chapter 3 SYSTEM SCANNING HARDWARE OVERVIEW

Instructors Guide: Atoms and Their Isotopes

PHYA5/1. General Certificate of Education Advanced Level Examination June Unit 5 Nuclear and Thermal Physics Section A

Introduction to Geiger Counters

Pesticide Analysis by Mass Spectrometry

Optimization of Digital Industrial Radiography (DIR) Techniques for Specific Applications: An IAEA Coordinated Research Project

Gamma and X-Ray Detection

EXPERIMENTAL CONDITIONS FOR CROSS SECTION MEASUREMENTS FOR ANALYTICAL PURPOSES. L. Csedreki 1. Abstract. I. Introduction

W. C. Reinig. Savannah River Laboratory E. I. du Pent de Nemours and Company Aiken, South Carolina 298o1

Scanners more rapidly and accurately identify radioactive materials at US borders, events 22 June 2016, by Rob Matheson

8.1 Radio Emission from Solar System objects

Neutron Detection Setups proposed for

[2] At the time of purchase of a Strontium-90 source, the activity is Bq.

ABSORPTION OF BETA AND GAMMA RADIATION

Appendix A. An Overview of Monte Carlo N-Particle Software

Testing of Kaonetics Devices at BNL

Gamma Ray Detection at RIA

Scan Time Reduction and X-ray Scatter Rejection in Dual Modality Breast Tomosynthesis. Tushita Patel 4/2/13

Nuclear Physics and Radioactivity

Mars Atmosphere and Volatile EvolutioN (MAVEN) Mission

EFFECT OF GAMMA RAY ENERGIES AND STEEL FIBER ADDITION BY WEIGHT ON SOME SHIELDING PROPERTIES OF LIMESTONE CONCRETE

2 KEV FILTERS OF QUASI-MONOCHROMATIC EPITHERMAL NEUTRONS

90 degrees Bremsstrahlung Source Term Produced in Thick Targets by 50 MeV to 10 GeV Electrons

ENERGY PER PHOTOELECTRON IN A COINCIDENCE LIQUID SCINTILLATION COUNTER AS A FUNCTION OF ELECTRON ENERGY. Donald L. Horrocks

From lowest energy to highest energy, which of the following correctly orders the different categories of electromagnetic radiation?

Nuclear Detonation Calculator

Chapter 8. Low energy ion scattering study of Fe 4 N on Cu(100)

Calculation of Source-detector Solid Angle, Using Monte Carlo Method, for Radioactive Sources with Various Geometries and Cylindrical Detector

Ch. 227 ANALYTICAL X-RAY EQUIPMENT 25

X Ray Flourescence (XRF)

F321 THE STRUCTURE OF ATOMS. ATOMS Atoms consist of a number of fundamental particles, the most important are... in the nucleus of an atom

Experiment 5. Lasers and laser mode structure

Medical Applications of radiation physics. Riccardo Faccini Universita di Roma La Sapienza

For convenience, we may consider an atom in two parts: the nucleus and the electrons.

Cutting Edge Digital Radiography Technology in Daily NDT Use

ENERGY LOSS OF ALPHA PARTICLES IN GASES

MASS DEFECT AND BINDING ENERGY

Nuclear Physics Lab I: Geiger-Müller Counter and Nuclear Counting Statistics

Chemistry 1000 Lecture 2: Nuclear reactions and radiation. Marc R. Roussel

GCE Physics A. Mark Scheme for June Unit G485: Fields, Particles and Frontiers of Physics. Advanced GCE. Oxford Cambridge and RSA Examinations

An Innovative Method for Dead Time Correction in Nuclear Spectroscopy

The data acquisition system of the XMASS experiment

Introduction to the Monte Carlo method

2 Absorbing Solar Energy

CHAPTER 7 SCINTILLATION COUNTING

History of the Atom & Atomic Theory

Objectives 404 CHAPTER 9 RADIATION

Objectives. PAM1014 Introduction to Radiation Physics. Constituents of Atoms. Atoms. Atoms. Atoms. Basic Atomic Theory

Application Note. ipix A Gamma imager to support various applications

X-ray Production. Target Interactions. Principles of Imaging Science I (RAD119) X-ray Production & Emission

Security Imaging Systems (X-Ray): Design, Measurements Regulations, and Standards

EDXRF of Used Automotive Catalytic Converters

Atomic Structure: Chapter Problems

The Physics of Energy sources Nuclear Reactor Practicalities

ENRICHMENT AND URANIUM MASS FROM NMIS FOR HEU METAL

Fuel Cell Activities at TU Graz

MCQ - ENERGY and CLIMATE

FTIR Instrumentation

MODELING AND IMPLEMENTATION OF THE MECHANICAL SYSTEM AND CONTROL OF A CT WITH LOW ENERGY PROTON BEAM

PROSPECT: Precision Reactor Oscillation and Spectrum experiment

TOF-PET DETECTOR CONCEPT BASED ON ORGANIC SCINTILLATORS

Monte Carlo simulation of a scanning whole body counter and the effect of BOMAB phantom size on the calibration.

Chapter 18: The Structure of the Atom

Basic Concepts of X-ray X Fluorescence by Miguel Santiago, Scientific Instrumentation Specialist

Lectures about XRF (X-Ray Fluorescence)

Jorge E. Fernández Laboratory of Montecuccolino (DIENCA), Alma Mater Studiorum University of Bologna, via dei Colli, 16, Bologna, Italy

NEUTRON ATTENUATOR PROTOTYPE TESTS ON THE PF1000 PLASMA FOCUS NEUTRON GENERATOR *

Synthetic Sensing: Proximity / Distance Sensors

Laboratory Technologies, Inc. Multi-Wiper. Time Saving Multiple Detector Wipe Counter

Phased Array Ultrasonic Inspection Of 25%Cr Super Duplex Stainless Steel. On Subsea Manifold Piping Girth Welds In Lieu Of Radiography

Nuclear Magnetic Resonance (NMR) Spectroscopy cont... Recommended Reading:

Transcription:

Final Report on CRP Entitled, NEUTRON BASED TECHNIQUES FOR DETECTION OF ILLICIT MATERIALS AND EXPLOSIVES Research contract 13497 R. M. Megahid *, A. M. Osman and, W. A. Kansouhfg Laboratories for Detection of Landmines and Illicit Materials, Nuclear Research Centre, Atomic Energy Authority Cairo, Egypt E-Mail: rmegahid2573@hotmail.com Fax: +2222876031 Summary: Terrorist use of explosives, chemical, biological and radiological weapons has become the main source of threat to homeland security for many countries (1-4). Scanning techniques based on manual and visual inspection of large payloads at borders are ineffective from time consideration. Even inspection by X and gamma ray imaging is not a viable solution since they lose specificity; low mass attenuation coefficients for H and N, high mass attenuation coefficients for heavy elements and uncapability for distinguish nearby elements due to regular attenuation coefficients. Hence to achieve the goal of international counter-terrorism, automatic, intrusive and specific techniques must applied to inspect objects of all sizes from small parcels to large containers. Nuclear inspection techniques based on using neutrons of different energies emitted from neutron generators and isotropic neutron sources offer a versatile and powerful inspection tool in different applications (5-9). Moreover, the experiences gained from the CRP implemented by IAEA on application of nuclear techniques for landmine detection have indicated the capability of neutron based techniques for identification of explosive materials. Hence, neutron based techniques can be used to inspect large commercial payloads for illicit trafficking. *Chief Scientific Investigator - 1 -

In this work, development, adaptation and implementation of nuclear techniques based on neutrons and gamma-rays emitted from small radioisotope sources were used to locate and identify explosive and contraband materials hidden in cargo containers. This objective was achieved by gamma or fast neutron radiography methods to locate the position of hidden object, followed by identification of the suspected object through elemental analysis by fast and thermal neutron activation. The radiography scanner and neutron identifier are combined into one complete system which is characterized by very low detection cost, mobility and ease to use by non specialists. A short description of the designed and installed manipulating mechanical container system and radiation scanning and identification systems are given in next section. 2- Combined Scanning and Identification Systems: The installed combined systems consist of container manipulator system, radiography scanner and neutron identifier. Figure 1 shows a schematic diagram for these systems. FIG. 1. Schematic diagram for the installed combined systems. - 2 -

2.1 Container Manipulating system: The system consists of a transfer table moves on steel frame by step motor. Inspected container is fixed on the transfer table and is moved between radiation source and detector in step increment varies from 0.05 mm to 100 mm. The system works as well in continuous mode in the backward and forward directions. The movement increment and time of measurements are changed and adjusted by a control unit. 2.2 Radiographic Scanner: The position of hidden object within container payload is located either by a gamma or fast neutron radiography scanner. A brief description of the installed gamma and fast neutron radiography scanners is given below: 2.2.1 Gamma-Ray Scanner: Initial efforts were performed to install a scanning system based on gamma-ray radiography. Accordingly, a gamma scanner based on using slit beam of gamma-ray emitted from 60 Co source was built and tested. A 60 Co gamma source of 0.5 Ci activity was fixed in a lead shield with horizontal channel where gamma-ray collimators can be inserted to have gamma-ray beams of different geometries. The gamma-rays transmitted through the inspected container are measured by NaI(Tl) detector housed in lead shield with slit collimator fixed in front of the detector lead shield to enhance the spatial resolution of the 2D image constructed from the transmitted gamma beam. The output signals of NaI(Tl) detector were amplified and fed to the input of a radiation analyzer to only count signals of gamma-rays of energy ranges from 1.1 to 1.4 MeV. The output of scan is fed to a counter/timer Nim module type, Ortec 776, and its output is fed to the input of PC for signal processing and image reconstruction. - 3 -

2.2.2 Fast Neutron Scanner: To improve the performance of scanning system for detection of objects hidden within thick and high dense materials, a fast neutron radiography system was installed and tested. This system works by using slit collimated beam of fast neutrons of 10 mm width and 20 mm height emitted from Pu-α-Be neutron source. The transmitted fast neutron beam was measured by stilbene scintillator fixed in high density polyethylene shield with slit collimator has the same dimensions of the incident neutron beam.. Figure 2 shows the circuit diagram of neutron/gamma spectrometer used to measure fast neutron transmitted through the inspected container To have a good quality image by fast neutron radiography a fast neutron source with high emission rate and neutron detector of high efficiency must be used. These two requirements could not be achieved in the installed fast neutron radiography scanner which uses 5 Ci Pu-α-Be source and organic scintillator with efficiency less than 20 % for neutrons of average energy ~ 4 MeV. The incident fast neutron flux was enhanced by surrounding the Pu-α-Be source directly with lead of spherical shape to work as fast neutron reflector.. The fast neutron count rate given by the neutron gamma spectrometer was only measured for fast neutrons of energies higher than 3 MeV to avoid artifact in the 2D image due to neutron multiple scattering. FIG.2. The circuit used in association with stilbene detector. - 4 -

2.3 Neutron Identifier: The installed neutron identifier makes use of the same neutron source and gamma detector built in fast neutron and gamma radiography scanner. The output of the detector amplified signals was fed to the input of a multichannel analyzer for gamma spectrum display. The prompt emitted gamma-ray spectrum emitted from the suspected object was measured for 600 sec. Measurements were then repeated for the same time to measure gamma-ray spectrum emitted from a position far from the allocated suspected object and the given spectrum is used as background object. 3- Results and Discussion: The cross-sectional 2D images for ATM with 2.5 kg explosive material hidden in a container filled with foam material are constructed from the measured transmitted gamma-rays and fast neutrons using MATLAPE 7.0 program. Measurements were performed with bare object and with the object screened in steel box with wall thickness = 1 cm. 3.1 Gamma Scanning: Fig.3. Shows the constructed images for bare and steel screened ATM. The displayed images give a good indication about the position of the hidden object inside the inspected container. Fig. 3. 2D - images constructed from gamma ray scanning of ATM hidden inside cargo container. 3.2 Fast Neutron Scanning: The images constructed from fast neutron radiography using 14 MeV neutrons and fast neutrons emitted from Pu- α -Be and 252 Cf sources are given in figures 4, 5 and 6. The displayed - 5 -

images indicate the good capability of the neutron scanner using fast neutrons emitted from radioisotic sources. They also indicate that the images obtained with Pu-α-Be neutron source are much better than that obtained with 252 Cf neutrons and are nearly of the same quality as those obtained by 14 MeV neutrons. FIG. 4. 2D - images constructed from 14 MeV neutron scanning of ATM hidden inside cargo container. FIG.5. 2D - images constructed from Pu-Be neutron scanning of ATM hidden inside cargo container. FIG.6. 2D - images constructed from 252 Cf neutrons scanning of ATM hidden inside cargo container. - 6 -

3.3 Neutron Identification : The net spectra of gamma rays resulting from fast and thermal neutron interactions with bare ATM and ATM (2.5 kg explosive) placed in steel box with walls of 1 cm thick are displayed in figures 7, 8 and 9. The spectra displayed in these figures are emitted when the object was interrogated by 14 MeV neutrons and neutrons emitted from Pu-α-Be and 252 Cf sources respectively. The spectra of gamma rays displayed in figure 7 are for gamma rays emitted from the bare and steel screened objects interrogated by 14 MeV neutrons. These two spectra show several gamma lines of energy varies from 1 to 7 MeV for gamma rays produced from the interaction of fast neutrons with the nuclei of explosive material, i.e., 1 H, 12 C, 14 N and 16 O. FIG.7. Gamma ray spectrum of ATM with 2.5 kg explosive material interrogated with 14 MeV neutrons. Figure 8 shows the net gamma ray spectra of the same ATM interrogated by Pu-α-Be neutron sources. These spectra show as well several gamma lines of energy varies from 2 to 7 MeV. These gamma lines are attributed to gamma rays produced from the interaction of fast and thermal neutrons with the nuclei of explosive material, i.e. 1 H, 12 C, 14 N, and 16 O. - 7 -

Fig. 8. Gamma ray spectrum of ATM with 2.5 kg explosive material interrogated with Pu-α-Be neutrons. Figure 9 shows the net gamma ray spectra for the same ATM without and with steel box interrogated by 252 Cf neutrons. The displayed spectra show only the gamma line of 2.23 MeV emitted from 1 H, the annihilation line of 0.511 MeV and 0.860 MeV emitted from 56 Fe nuclei of the steel box by inelastic scattering. Fig. 9. Gamma ray spectrum of ATM with 2.5 kg explosive material interrogated with 252 Cf neutrons. The measured net gamma spectra displayed in the previous figures show that the screening of the hidden object by element of high inelastic scattering cross sections tends to enhance the moderation of fast neutrons and hence decreases the number of gamma photons emitted by inelastic scattering with 12 C and 16 O. However, screening the object by steel - 8 -

decreases the number of gamma photons produced from thermal neutron capture. These phenomena are clearly observed from the net count rate of gamma rays emitted from different interactions by fast and thermal neutrons with the object nuclei as shown from the count rate of the gamma peak tabulated in Table 1. Table 1. Gamma energies emitted by fast and thermal neutron interactions using different radioisotope sources Conclusions: The installed combined scanning and identification systems prove a good capability to locate the position and identify the material of hidden object in cargo containers. The scanning system can work by either gamma or fast neutron radiography technique, with nearly the same effectiveness. The use of fast neutron radiography with neutrons emitted from Pu-α-Be sources to scan cargo-containers show the same reliability and easiness as those work with gamma emitted from 60 Co source. The use of these neutrons to radiograph objects gives nearly the same image quality obtained by 14 MeV neutron or neutrons of like fission neutron spectrum emitted from 252 Cf neutron sources. Although fast neutrons emitted from α-be sources are less capable to detect carbon and oxygen than 14 MeV neutrons, they are much easier to moderate and hence become more capable to identify elements by thermal neutron activation analysis. The effectiveness of a scanner works with isotopic fast neutron source can be enhanced to ~ 40 % if the source is surrounded by fast neutron reflector made of heavy material. - 9 -

A combined systems work with only one simple isotopic neutron source possess very low scanning cost, reduced source shield, low weight and possibility to use as mobile scanning system. Recommendations: Fast neutron sources of high emission rate ~ 10 10 n/s and fast neutron detector of higher detection efficiency must be used to improve the scanning performance. With such a neutron source and neutron detector, it becomes possible to scan a container of relatively large volume in shorter time. Fan beam of fast neutrons and an array of radiation detectors must be installed and used to provide quick scanning of the suspected object hidden in container of various sizes. Further investigations have to be performed to check the effectiveness of the installed References: combined system for locating and identifying fertile and fissile materials hidden in cargo containers. [1] J. R. Cliffrd, et al., An Explosive Detection System for Screening Luggage with High Energy x-rays, Proceeding of the First International Symposium on Explosive Detection Technology, Nov.13-15, (1991). [2] J. E. McFee and Y. Das, Advances in the location and identification of Hidden Explosive Munitions, Report No.548, Suffield, Defence Research Establishment, (1991). [3] L. Grodzins, Detecting Contraband in Luggage, Nucl. Instr. And Meth. B79, 597-600, (1993). [4] T. Gozani, et al., Apparatus and Method for Detecting Contraband Using Fast Neutron Activation, U.S. Patent #5, 098, 640, field January 1990, awarded March (1992). [5] G. Vourvopoulas, Accelerator based Techniques for Contraband Detection, Nucl. Instr. Nd Meth. B_89, 388-393 (1994). [6] G. Vourvopoulos and R. C. Womble, Pulsed Fast/Thermal Neutron Analysis: A Technique for Explosives Detection, ATLANTA 54 (2001) 459-468, G. Eiceman, Editor, ELSEVIER (2001). [7] Z.P. Sowa, et al., Contraband Detection System Using Direct Imaging Pulsed Fast Neutrons, U.S. Patent 5, 076, 993, field January 1990, awarded December (1991). [8] N. Toyofuku and T. F. Schatzki, Image feature based detection of agricultural quarantine materials in X-ray images, Journal of Air Transport Management 13, 348 354 (2007). [9] H. Vogel and D. Haller Luggage and shipped goods, European Journal of Radiology 63, 242 253 (2007). - 10 -