105, , , ,000

Similar documents
NAVIEN AMERICA INC FITCH AVENUE

12288 Side Road 22, Wainfleet, Ontario Canada L0S 1V0 Phone: Fax:

Gas Unit Heaters Duct Furnaces Horizontal - 60 HZ Form No. LF (10/2011) LF24 Standard

BC & BCH SERIES INDOOR / OUTDOOR INSTALLATION

Commercial Gas Furnace Upflow

One Year Warranty. Stock U.S. # of Volts Weight CONN. Height Dia. Watts # GAL. Elements INS. Inches NATURAL GAS* Six Year Warranty

Residential/Commercial Gas Condensing High Efficiency Tankless Water Heaters

Owner Retain this manual in a safe place to provide your serviceman information if it becomes necessary.

M7RL Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. High Efficiency / Direct Vent Condensing Downflow Gas Furnace

TANKLESS WATER HEATER INSTALLATION DIAGRAMS

Your safety and the safety of others are very important.

HEAVY DUTY STORAGE GAS

Commercial Gas Water Heater

Cooling Capacity CFM in. w.c. (125 Pa)


SIMPLE ELECTRONIC IGNITION WIRE DIAGRAM THERMOSTAT (3) PV PILOT BURNER/IGNITOR - SENSOR Q345A (9) SPARK (4) GND (BURNER) CHASSIS GND

Cooling Capacity CFM in. w.c. (125 Pa)

USER S, MAINTENANCE and SERVICE INFORMATION MANUAL

Rheem Spare Parts Manual. Commercial gas model A Exterior 265L

G26 Corp L11 Revised LENNOXOEMPARTS.COM. Service Literature G26 SERIES UNITS

Commercial Gas Water Heaters

Cooling Capacity CFM in. w.c. (125 Pa)

Commercial Gas Water Heaters

SL280UHV SERIES GAS FURNACE WARNING

Installation Manual CLIFC Fan & Coil Variable Speed

TECHNICAL GUIDE 95.5% SINGLE STAGE GAS-FIRED RESIDENTIAL MULTI-POSITION GAS FURNACES MODELS: TG9S DESCRIPTION FEATURES

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

2010 Residential Water Heater Replacement Check List

American Fireglass Outdoor Fire pit kit information. General instructions/warnings for outdoor gas pan and burner systems

ASX7-4-IOM-7 J

Ceiling Mount Air Handler Manual

Propane Conversion Kit PROPANE CONVERSION KIT INSTALLATION MANUAL

Applies to: Models F, B, FE, and BE FOR YOUR SAFETY

F9MXE. Product Specifications

TB-A A. O. SMITH - FVIR INTELLI-VENT TROUBLESHOOTING CHART # LED STATUS PROBLEM SOLUTION

IMPORTANT: BEFORE INSTALLING ANY HEATING TERMINAL UNIT TO A DOMESTIC WATER HEATER, CONSULT THE LOCAL PLUMBING CODES.

Technical Instructions Document No P25 ET September 28, ET 141 High Limit Control Thermostat. Description.

Installation Instructions

Replacement parts. WM97+ gas-fired water boiler Boiler Manual. OBTAIN PARTS ONLY THROUGH WEIL-McLAIN THE BOILER CONTAINS CERAMIC FIBER MATERIALS

G670 Intermittent Pilot Ignition Controls

OWNER S MANUAL FORCE 10 MARINE COMPANY HAMILTON ROAD RICHMOND, BC CANADA V6V 1C9 TEL: (604) FAX: (604)

CROWN BOILER COMPANY BWF SERIES BOILER CATEGORY I VENT KIT INSTALLATION AND OPERATING INSTRUCTIONS


Roof Top Air Conditioner INSTALLATION AND OPERATING INSTRUCTIONS

PRE-ASSEMBLED INSTALLATION INSTRUCTIONS FOR PACB SERIES COAL FIRED OVENS

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

XV80 UPFLOW/HORIZONTAL 2-STAGE, VARIABLE SPEED GAS-FIRED FURNACE

CARING FOR YOUR WATER HEATER

Commercial Gas Water Heaters

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

Electric & Gas Water Heaters

Fossil fuel heating equipment

RECON WATER HEATER INSTALLATION FORM

OVEN PARTS For Models:GSC308PJB05, GSC308PJQ05, GSC308PJT05, GSC308PJS05 (Black) (White) (Biscuit) (Black Stainless)

MODEL IX -WAC/HP AIR CONDITIONERS & HEAT PUMPS FOR HIGHLY CORROSIVE & HAZARDOUS AREAS

LAKE COUNTY ANIMAL SERVICES EXPANSION SECTION 15459

PART 6: VENTING, COMBUSTION AIR & CONDENSATE REMOVAL

Model Description / Applications. Intermittent Pilot Gas Ignition Control

PARTS CATALOG RPPCR01111_Front_Backcx.indd 1 RPPCR01111_Front_Backcx.indd 1 11/21/11 1:41 PM 11/21/11 1:41 PM

C. Burner management system to follow requirements of Industrial Risk Insurers (IRI).

WARDEN 4 ELECTRONIC WATER MANAGEMENT SYSTEM FEATURING:

Heating and cooling a home in Australia amounts to around

Gas-Fired, Residential Storage Type Water Heaters

Series GM. Peerless Boilers. Residential/Commercial Gas Boilers

UHIR Series. Horizontal or Vertical Mounting Industrial / Commercial Electric Unit Heater. Owner s Manual

TECHNICAL MANUAL GDS8 & GHS8

RPV - RP - RA air handling units

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT

Up To 99% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS WITH MODBUS PROTOCOL, CASCADING SEQUENCER AND FRONT-END LOADING CAPABILITY

prestige Condensing Water Boiler SERVICE TECHNICIAN S TROUBLE SHOOTING GUIDE TSG-PRESTIGE Date revised: 12/6/10

All work must conform to the National Electric Code, latest edition, and all other applicable codes and regulations.

INSTALLATION AND OPERATIONS GUIDE FOR GRAND CANYON GAS LOG SYSTEMS

SUGGESTED SPECIFICATION EXHAUST SYSTEM SILENCER, FLEX CONNECTOR, INSULATION BLANKETS, WALL / ROOF THIMBLES

HOW MUCH FUEL DOES A GAS STOVE CONSUME AND HOW MUCH DOES IT COST TO OPERATE?

Pump Specifications 250 Series Submersible Sump / Effluent Pump 2 Solids handling

Installation Operation & Maintenance Manual

G9MXE. Product Specifications

Operation and Installation Manual. Max Series

Gas Stoves. H15-10 Direct Vent Gas Stove. Model H15-NG10 H15-LP10. Approved Venting Systems

Rinnai Tankless. Water Heater. Troubleshooting Manual

Boiler and Burner Cleaning and Servicing Specifications

SMD Rework Station TABLE OF CONTENTS

Twin Pipe PVC / CPVC Venting options for Rinnai Ultra Series Condensing Tankless Water Heaters.

Centauri. Condensing Fire Tube Water Boiler 399 to 1000 MBH

Your safety and the safety of others are very important.

Boston, Venice, Kodiak. Enviro Wood Fireplace Inserts

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

Service Handbook Commercial / Residential gas water heater

Failure to comply with the following cautions and warnings could cause equipment damage and personal injury.

INSTALL INSTRUCTIONS KK-C-HVAC-1 HVAC UNIT CHEVROLET/GMC VANS FOR

36G22, 36G23, 36G24 & 36G52 36J22, 36J23, 36J24 & 36J52 DSI and HSI Single Stage Combination Gas Valve

COMMERCIAL GAS DRYER

TWIN EAGLES ALL WEATHER ELECTRIC RADIANT HEATER

Installation & Operation Manual Models: ER152, ER202, ER252, ER302, and ER402

OIL FURNACES CLASSIC PREMIUM CLASS UPFLOW OIL FURNACES. ROBD- SERIES Heating Capacities 56,000 to 151,200 BTU/HR [16.41 to 44.

Evaluate, Clean, and Tune Guidance

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE

THC 85 INDUSTRIAL / COMMERCIAL SPACE HEATER

Electronic Flow Switches

MODEL BRT GAS-FIRED TUBULAR UNIT HEATERS

Transcription:

Adding the letter B to the prefix indicates a brooder model. Adding the suffix LTH indicates dual input with the low input being 70% of the high input. Adding the suffix CW indicates a car wash heater. Model O/A Length Input (BTU) Weight EZ(SH)60-20 21 ft. 8 / 6.6 m 60,000 90 lbs / 40.82 kg EZ(SH)75-20 21 ft. 8 / 6.6 m 60,000 75,000 90 lbs / 40.82 kg EZ(SH)80-20 21 ft. 8 / 6.6 m 60,000 80,000 90 lbs / 40.82 kg EZ(SH)85-30 31 ft. 5 / 9.56 m 60,000 85,000 105 lbs / 47.63 kg EZ(SH)100-30 31 ft. 5 / 9.56 m 70,000 100,000 105 lbs / 47.63 kg EZ(SH)125-30 31 ft. 5 / 9.56 m 90,000 125,000 105 lbs / 47.63 kg EZ(SH)100-40 41 ft. 2 / 12.55 m 70,000 100,000 130 lbs / 58.97 kg EZ(SH)125-40 41 ft. 2 / 12.55 m 90,000 125,000 130 lbs / 58.97 kg EZ(SH)150-40 EZ(SH)160-40 41 ft. 2 / 12.55 m 41 ft. 2 / 12.55 m 105,000 150,000 112,000 160,000 130 lbs / 58.97 kg 130 lbs / 58.97 kg EZ(SH)125-50 50 ft. 11 / 15.5 m 90,000 125,000 150 lbs / 68.04 kg EZ(SH)135-50 50 ft. 11 / 15.5 m 95,000 135,000 150 lbs / 68.04 kg EZ(SH)150-50 50 ft. 11 / 15.5 m 105,000 150,000 150 lbs / 68.04 kg EZ(SH)165-50 50 ft. 11 / 15.5 m 115,000 165,000 150 lbs / 68.04 kg EZ(SH)165-60 60 ft. 8 / 18.5 m 115,000 165,000 165 lbs / 74.84 kg EZ(SH)200-60 60 ft. 8 / 18.5 m 160,000 200,000 (180,000 L.P.) 165 lbs / 74.84 kg EZ(SH)200-70 70 ft. 5 / 21.46 m 160,000 200,000 (180,000 L.P.) 180 lbs / 81.65 kg EZU(SHU)60-10 11 ft. 11 / 3.63 m 60,000 90 lbs / 40.82 kg EZU(SHU)75-10 11 ft. 11 / 3.63 m 60,000 75,000 90 lbs / 40.82 kg EZU(SHU)80-10 11 ft. 11 / 3.63 m 60,000 80,000 90 lbs / 40.82 kg EZU(SHU)85-15 16 ft. 8 / 5.08 m 60,000 85,000 105 lbs / 47.63 kg EZU(SHU)100-15 16 ft. 8 / 5.08 m 70,000 100,000 105 lbs / 47.63 kg EZU(SHU)125-15 16 ft. 8 / 5.08 m 90,000-125,000 105 lbs / 47.63 kg EZU(SHU)100-20 21 ft. 8 / 6.6 m 70,000 100,000 130 lbs / 58.97 kg EZU(SHU)125-20 21 ft. 8 / 6.6 m 90,000 125,000 130 lbs / 58.97 kg EZU(SHU)150-20 21 ft. 8 / 6.6 m 105,000 150,000 130 lbs / 58.97 kg EZU(SHU)125-30 31 ft. 5 / 9.56 m 90,000 125,000 165 lbs / 74.84 kg EZU(SHU)135-30 31 ft. 5 / 9.56 m 95,000 135,000 165 lbs / 74.84 kg EZU(SHU)150-30 31 ft. 5 / 9.56 m 105,000 150,000 165 lbs / 74.84 kg EZU(SHU)165-30 31 ft. 5 / 9.56 m 115,000 165,000 165 lbs / 74.84 kg EZU(SHU)200-30 31 ft. 5 / 9.56 m 160,000 200,000 (180,000 L.P.) 165 lbs / 74.84 kg CLEARANCES TO COMBUSTIBLES BTU RANGE BELOW TOP SIDES BACK (Angle Mount) 60,000-150,000 48 / 121.92 cm 4 / 10.16 cm 25 / 63.5 cm 16 / 40.64 cm 150,001-165,000 58 / 147.32 cm 4 / 10.16 cm 25 / 63.5 cm 16 / 40.64 cm 165,001 200,000 74 / 187.96 cm 4 / 10.16 cm 25 / 63.5 cm 16 / 40.64 cm Clearances below can be reduced by 40% beginning 15 ft. downstream of burner. Page 1

SPECIFICATIONS APPROVALS * Certified by Intertek ETL * Certified for use in Canada and the USA * Tested and certified to all applicable CAN/CGA, CSA, and ANSI standards. * Commercial, Industrial, and Agricultural approvals. BURNER CONTROL BOX * Totally enclosed controls * Sight glass for visual combustion observation * Controls serviceable while in operation and isolated from combustion air * EZ models c/w operating indicator light * CW models c/w stainless steel control box * Easy access to controls with the removal of one screw with exclusive hinged Clamshell control box design. * Thermally protected and permanently lubricated blower motor * 5 long grounded cap and cord plug in 110v connection COMBUSTION AIR & VENTING * 4 combustion air inlet and exhaust * Certified for direct sidewall, roof, and open venting * Maximum 60 of combined intake and vent line (NOT including length of unit) in any combination (eg. 15 intake, 45 vent). Deduct 5 from 60 allowance for every 90 degree bend in intake/vent line. GAS SPECIFICATIONS Pressures in W.C.P. NG (inches) LP (inches) Manifold 3.5 10 Min. Inlet 7 14 Max. Inlet 14 14 ELECTRICAL SPECIFICATIONS * 120 V.A.C., 60 Hz, 1 Ph., 3 wire * Supplied via 5 ft. 120v 3 wire cap and cord plug in connection * Factory ready for 120v or 24v thermostatic controls * Ignition current 3 amps * Running current 1 amp CONTROLS * Norton ceramic hot surface mini igniter * Air proving safety switch monitors for blocked flu and intake air * Independent flame sensing rod Honeywell Smart valve OR White Rogers valve with proprietary electronic controls made in the USA * LTH 2 stage models c/w White Rogers valve and proprietary electronic controls made in the USA COMBUSTION & EMITTER TUBES * All emitter & combustion tubes are 16 ga., 4 OD * Tubes press fitted with swaged ends * Primary combustion tubes constructed of high temperature specialty alloys * Secondary tubes are constructed of highly emissive low carbon black steel. EZ model secondary tubes are coated with high temperature, corrosion resistant black coating. CW tubes constructed of coated Aluminized steel for superior corrosion resistance in harsh environments * High temperature, aluminized steel turbulator baffle factory installed (if required) REFLECTOR * Highly polished, high grade seamless aluminum for maximum reflective efficiency * EZ models c/w upgraded mirror polish for superior reflectivity and emission NO IFS, ANDS, OR BUTS WARRANTY * 4 Years on ALL heater components * 20 year burnout guarantee on combustion and emitter tubes MANUFACTURED IN CANADA WITH NORTH AMERICAN MADE COMPONENTS AND MATERIALS COMMON ACCESSORIES PART # DESCRIPTION NOTES AC1072 ½ x 36 Neoprene Flexible Gas Connector Required for units under 150,000 BTU input AC1073 ¾ x 36 Neoprene Flexible Gas Connector Required for units 150,000 BTU + input AC1220 Fresh Air Intake Package 10 flex duct, screened intake cap, c/w clamps & connectors AC1180 Sidewall Exhaust Cap 4 OD - type B Vent Required for direct sidewall venting AC1190 Sidewall Exhaust Cap 4 ID - type C Vent Required for direct sidewall venting AC1120 4 x 4 x 6 Exhaust T For common venting Note: units MUST be jointly controlled. AC1060 24v Analog Thermostat In Celsius. For Fahrenheit, use part #AC1062 AC1010 110v Analog Thermostat For control of single or multiple units AC1400 24v 2 Stage Thermostat For control of single or multiple units (req. relays not supplied) AC2000 24v Light Activated Set Back Digital Stat The Easy Set www.easyradiantworks.com/easyset.html P-1930 9 x 10 Side Reflector Reflector side shield to reduce output on sides of heater Page 2

FIELD SPECIFICATIONS SIDEWALL VENTING ROOF VENTING *Note: Vent lines longer than 10 must be insulated or constructed of insulated type B material. End View Horizontal and Angle Mount Page 3

FIELD SPECIFICATIONS (Cont.) Burner and Controls Side View U Configuration Top Down Straight Configuration Top Down Page 4

WRITTEN SPECIFICATIONS Gas fired radiant tube heaters shall be Spartan (SH) or Comfortzone (EZ) series heaters manufactured by Easy Radiant Works, Wainfleet, Ontario, Canada. Radiant tube heaters shall be furnished and installed in compliance with all applicable governing codes and in compliance with included manufactures specifications. In cases where manufacturers instructions and governing codes conflict, installer shall defer to whichever is most stringent. Radiant tube heaters shall be Design Certified by Intertek ETL, and comply with all applicable standards including CAN/CGA, CSA, and ANSI. All radiant tube heaters must bear the Intertek ETL certification mark and manufacturers serial number. Radiant tube heaters shall be supplied with a manufacturers warranty covering all components for a period of no less than four (4) years. Combustion and radiant emitter tubes shall be warranted against burnout for a period of no less than twenty (20) years. Radiant tube heaters shall be supplied with a copy of the manufacturers installation and operation manual. Burner controls shall be totally contained within a control housing that is isolated from combustion air. Control housing shall be of such construction that internal components are accessible for diagnostic purposes while heater is in operation. Control housing shall be of the clamshell type, with access granted to controls by the removal of exterior retaining screws. Combustion tubes shall be constructed of 16 ga. (0.065 ), 4 dia. aluminized steel tube coated with black high temperature coating. On units where inputs exceed 165,000 BTU, the unit shall utilize two 10 combustion tubes constructed of GalvAlum alloy. Emitter tubes shall be constructed of 16 ga. (0.065 ), 4 dia. low carbon steel tube. EZ model emitter tubes shall be coated with high temperature black coating. CW model emitter tubes shall be constructed of all aluminized steel with high temperature black coating. Combustion and emitter tubes joints shall be of press fit design with swaged ends at 4 ID. Tubes shall be mechanically secured by means of manufacturer provided self drilling screws. Reflector material shall have a minimum thickness of 0.025 (+/-.001 ), shall be constructed of seamless 3003 aluminum sheet, and be tempered to specifications H24-H25. Reflector finish shall be a minimum of Brite-one-side. Heaters shall be equipped with an electronic hotsurface igniter that is enclosed in a protective metal jacket. Heaters shall be equipped with an independent flame sensor. Heaters shall be equipped with a sight glass for visual confirmation of combustion and igniter operation. EZ models shall be equipped with an operating indicator light on the bottom of the control housing to indicate normal heater operation. Single stage heaters shall utilize the Honeywell Smart Valve or a White Rogers valve with proprietary control module for control sequencing and gas flow regulation. Two stage units shall utilize a White Rogers two stage valve with proprietary control module. Units shall utilize two dedicated mechanical air pressure switches, one for blocked flue and one for combustion intake air pressures. Air switches shall be factory set to correct pressures with no requirement for field adjustment. Units shall be constructed with a five foot (5 ) long grounded 110v capped connector. Units shall be supplied ready to accept both 110v and 24v thermostatic controls. If required, heaters shall be equipped with a preinstalled turbulator baffle constructed of aluminized steel, and pre-installed by the factory in a marked 10 section of emitter tube for installation on the exhaust end of the heater. Heater shall be constructed that total safety shut down will occur in the events of : loss of combustion, blocked flue, blocked air intake, blower failure, loss of 110v power, increase of gas pressure beyond specification, or combustion failure on ignition attempt. Unit shall lock out operation entirely in the event that there are three (3) to five (5) consecutive failures, and only be reset by means of disconnection of 110v power supply. Page 5

CONTACT INFORMATION SUBMITTED BY: JOB JOB TITLE: ENGINEER COMPANY: DATE: CONTRACTOR COMPANY: EQUIPMENT REPRESENTATIVE COMPANY: WARNING! Heaters must be installed and serviced by qualified and licensed gas personnel only. Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read the installation, operating and maintenance instructions thoroughly before installing or servicing this equipment. This spec-sheet is not the installation manual. Page 6