PILE JACKING IN SAND AND SILT

Similar documents
Field tests using an instrumented model pipe pile in sand

Penetration rate effects on cone resistance measured in a calibration chamber

USE OF CONE PENETRATION TEST IN PILE DESIGN

TECHNICAL REPORT ON SCALA DYNAMIC CONE PENETROMETER IRREGULARITY

Lymon C. Reese & Associates LCR&A Consulting Services Tests of Piles Under Axial Load

NUMERICAL MODELLING OF PIEZOCONE PENETRATION IN CLAY

c. Borehole Shear Test (BST): BST is performed according to the instructions published by Handy Geotechnical Instruments, Inc.

Cone Penetration Testing (CPT) Michael Bailey, P.G. U.S. Army Corps of Engineers, Savannah District

CHAPTER 1 INTRODUCTION

SAMPLE GUIDE SPECIFICATIONS FOR OSTERBERG CELL LOAD TESTING OF DEEP FOUNDATIONS

ESTIMATION OF UNDRAINED SETTLEMENT OF SHALLOW FOUNDATIONS ON LONDON CLAY

PDCA Driven-Pile Terms and Definitions

Cone Penetration Testing in Geotechnical Practice. Tom Lunne Peter K. Robertson John J.M. Powell

The advantages and disadvantages of dynamic load testing and statnamic load testing

ALLOWABLE LOADS ON A SINGLE PILE

SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS

KWANG SING ENGINEERING PTE LTD

Step 11 Static Load Testing

Drained and Undrained Conditions. Undrained and Drained Shear Strength

Embedded Retaining Wall Design Engineering or Paradox?

Figure CPT Equipment

Module 1 : Site Exploration and Geotechnical Investigation. Lecture 4 : In-situ tests [ Section 4.1: Penetrometer Tests ] Objectives

CEEN Geotechnical Engineering Laboratory Session 7 - Direct Shear and Unconfined Compression Tests

Appendix A Sub surface displacements around excavations Data presented in Xdisp sample file

By D. P. StewarP and M. F. Randolph z

Eurocode 7 - Geotechnical design - Part 2 Ground investigation and testing

An Automatic Kunzelstab Penetration Test

HAULBOWLINE, CORK STATIC CONE PENETRATION TESTS FACTUAL REPORT

Press-in piling: Ground vibration and noise during pile installation. David White*, Tim Finlay**, Malcolm Bolton*** and Grant Bearss****

METHOD OF STATEMENT FOR STATIC LOADING TEST

INTRODUCTION TO SOIL MODULI. Jean-Louis BRIAUD 1

Measurement of Soil Parameters by Using Penetrometer Needle Apparatus

Numerical Simulation of CPT Tip Resistance in Layered Soil

Toe Bearing Capacity of Piles from Cone Penetration Test (CPT) Data

PILE FOUNDATIONS FM 5-134

Ground improvement using the vibro-stone column technique

Design of pile foundations following Eurocode 7-Section 7

STATNAMIC : Pile Load Testing Equipment

Hardened Concrete. Lecture No. 14

INSITU TESTS! Shear Vanes! Shear Vanes! Shear Vane Test! Sensitive Soils! Insitu testing is used for two reasons:!

Jack-in Piling Environmental Friendly Piling System

GUIDELINE FOR HAND HELD SHEAR VANE TEST

Equivalent CPT Method for Calculating Shallow Foundation Settlements in the Piedmont Residual Soils Based on the DMT Constrained Modulus Approach.

Geotechnical Measurements and Explorations Prof. Nihar Ranjan Patra Department of Civil Engineering Indian Institute of Technology, Kanpur

PREDICTING THE HYDRAULIC CONDUCTIVITY OF MAKASSAR MARINE CLAY USING FIELD PENETRATION TEST (CPTU) RESULTS

Numerical Analysis of Texas Cone Penetration Test

APPENDIX A PRESSUREMETER TEST INTERPRETATION

Standard Test Method for Mechanical Cone Penetration Tests of Soil 1

SUGGESTION ABOUT DETERMINATION OF THE BEARING CAPACITY OF PILES ON THE BASIS OF CPT SOUNDING TESTS

Improvement in physical properties for ground treated with rapid impact compaction

NEGATIVE SKIN FRICTION AND SETTLEMENT OF PILES. Dr. Bengt H. Fellenius, P. Eng. University of Ottawa, Canada

DEM modelling of the dynamic penetration process on Mars as a part of the NASA InSight Mission

Figure A-1. Figure A-2. continued on next page... HPM-1. Grout Reservoir. Neat Cement Grout (Very Flowable) Extension Displacement Plate

Use and Application of Piezocone Penetration Testing in Presumpscot Formation

Local Authority Building Control Technical Information Note 3 Driven and In-situ Piled Foundations

Dynamic Load Testing of Helical Piles

Numerical study of rate effects in cone penetration test

Helical Piles. A Practical Guide to Design and Installation

GLOSSARY OF TERMINOLOGY

Validation of methods for assessing tunnelling-induced settlements on piles

Site Investigation. Some unsung heroes of Civil Engineering. buried right under your feet. 4. Need good knowledge of the soil conditions

product manual HS-4210 HS-4210_MAN_09.08 Digital Static Cone Penetrometer

EVALUATING INSTALLATION DISTURBANCE OF HELICAL ANCHORS IN CLAY FROM FIELD VANE TESTS

Comprehensive Design Example 2: Foundations for Bulk Storage Facility

Instrumentations, Pile Group Load Testing, and Data Analysis Part II: Design & Analysis of Lateral Load Test. Murad Abu-Farsakh, Ph.D., P.E.

Anirudhan I.V. Geotechnical Solutions, Chennai

Geotechnic Parameters Analysis Obtained by Pencel Presuremeter Test on Clayey Soils in Resistencia City

INDIRECT METHODS SOUNDING OR PENETRATION TESTS. Dr. K. M. Kouzer, Associate Professor in Civil Engineering, GEC Kozhikode

EN Eurocode 7. Section 10 Hydraulic Failure Section 11 Overall Stability Section 12 Embankments. Trevor L.L. Orr Trinity College Dublin Ireland

vulcanhammer.net This document downloaded from

1 Mobilisation and demobilisation 1 Deep boring sum 2 Cone penetration tests sum 3 Miscellenous tests sum

Proceedings of the ASME 28 TH International Conference on Ocean, Offshore and Arctic Engineering OMAE2009 May 31 June 5, 2009, Honolulu, Hawaii, USA

DESIGN OF AXIALLY LOADED COMPRESSION PILES ACCORDING TO EUROCODE 7

BEARING CAPACITY AND SETTLEMENT RESPONSE OF RAFT FOUNDATION ON SAND USING STANDARD PENETRATION TEST METHOD

Ingeniería y Georiesgos Ingeniería Geotécnica Car 19 a Nº of 204 ; TEL : igr@ingeoriesgos.com

Soil Classification Through Penetration Tests

Constant Rate of Strain Consolidation with Radial Drainage

vulcanhammer.net Visit our companion site

System. Stability. Security. Integrity. 150 Helical Anchor

Effect of grain size, gradation and relative density on shear strength and dynamic cone penetration index of Mahi, Sabarmati and Vatrak Sand

NOTES on the CONE PENETROMETER TEST

Effect of drainage conditions on cone penetration testing in silty soils

Caltrans Geotechnical Manual

A case study of large screw pile groups behaviour

Dead load (kentledge) A structure over the test pile. Ground anchorage either by tension piles or ground anchors. Bi-directional (Osterberg-cell)

Pavements should be well drained both during and upon completion of construction. Water should not be allowed to pond on or near pavement surfaces.

SPECIFICATION FOR DYNAMIC CONSOLIDATION / DYNAMIC REPLACEMENT

Centrifuge cone penetration tests in sand

ADVANCEMENTS IN STATNAMIC DATA REGRESSION TECHNIQUES

SEISMIC SETTLEMENT OF SHALLOW FOUNDATIONS

ITEM # OSTERBERG CELL LOAD TESTING OF DRILLED SHAFT

CONE PENETRATION TESTING AND SITE EXPLORATION IN EVALUATING THE LIQUEFACTION RESISTANCE OF SANDS AND SILTY SANDS ABSTRACT

Pile test at the Shard London Bridge

Geotechnical Testing Methods II

DESIGN OF PILES AND PILE GROUPS CONSIDERING CAPACITY, SETTLEMENT, AND NEGATIVE SKIN FRICTION

How To Design A Foundation

Unit 24: Applications of Pneumatics and Hydraulics

CPTic_CSM8. A spreadsheet tool for identifying soil types and layering from CPTU data using the I c method. USER S MANUAL. J. A.

How To Model A Shallow Foundation

Transcription:

Abstract PILE JACKING IN SAND AND SILT Andrew Jackson (amj35@cam.ac.uk) Cambridge University Engineering Department 13 February Pile jacking (also known as press-in piling ) is an innovative technique for the installation of preformed piles, in which hydraulic rams are used to push the piles into the ground. Machines have been developed to allow this technique to be used quickly and efficiently. Advantages over traditional techniques such as dynamic pile driving include greatly reduced noise and vibration during installation. The use of pile jacking presents new challenges for the geotechnical engineer. Designers of jacked piles for any loading must predict the short-term axial force that will resist pile installation, so that a piling machine with a sufficiently high capacity to overcome this resistance can be selected. If unexpectedly high resistance is encountered, the piler may be unable to advance the piles to the required embedment. In many cases this installation resistance may be different from the long-term ultimate capacity which the pile can mobilise to resist applied axial loads. This paper describes a field investigation into the force required to jack piles into sand and silt. A series of field tests involving installing a 15m-long closed-ended tubular steel pile at a site in Japan is reported. During each test the total installation resistance was recorded and sensors in the pile measured the forces on the base and shaft. These resistances were found to be consistently less than standard predictions of the medium-term ultimate axial capacity from CPT (cone penetration test) data. This difference appears to be caused by rate-dependent partially-drained installation behaviour. Excess pore water pressure generated during installation reduces the installation resistance, making it lower than the drained medium-term capacity. The significance of this behaviour for designers of jacked piles is discussed, and techniques for predicting it are investigated. The Jacked Piling Method The expansion of urban construction onto increasingly marginal sites is making the use of piled foundations an ever more attractive option for designers. One common form of piling, which can offer a higher ultimate capacity and stiffness than bored piling, is driven piling. However, pile driving produces levels of noise and ground-borne vibration which are unacceptable for many urban sites. A relatively new piling technique which offers the benefits of driven piling with additional advantages including reduced noise and vibration is jacked (or press-in ) piling. In this method, a static jacking force is applied to a preformed pile to push it into the ground. The Silent Piler type of pile jacking machine (Figure 1 overleaf) is capable of self-walking along an advancing wall of piles, and gains reaction from previously-installed piles. The machine can be controlled by a single operator, with fresh piles being delivered by a single crane. Although developed in Japan, the technology has been used throughout the world (1), including on the Grand Arcade project in Cambridge ().

Previous research (3) has identified many advantages of jacked piling over traditional techniques, including: Jackson, A. Pile Jacking in Sand and. 7. very low levels of noise and vibration; enhanced capacity due to the low number of stress cycles experienced by the soil around the pile during installation; enhanced stiffness due to the full pre-loading experienced by the soil around the pile during installation; the potential for extraction and reuse of temporary piles, bringing cost savings and environmental benefits; and the ability to use the measured installation resistance as an indicator of the pile capacity. Figure 1: A Silent Piler However, the use of pile jacking presents new challenges for the geotechnical engineer. Designers of axially-loaded piles of any type require a prediction of the long-term ultimate axial strength that can be mobilised to support the applied load. Designers of jacked piles must also predict the shortterm axial force that will resist pile installation, so that a piling machine with a sufficiently high capacity to overcome this resistance can be selected. Much previous research has considered the ultimate axial strength of piles, but this is often not the primary factor controlling pile design; serviceability stiffness criteria or the strength required to resist other loading conditions may be more critical. Less research has considered the installation resistance, but this dictates piler selection irrespective of any stiffness criteria or later loading conditions. In many cases, the short-term axial force resisting pile installation is different from the longer-term pile capacity. If unexpectedly high installation resistance is encountered, the piler may be unable to advance the piles to the required embedment. As discussed later, the resistance and strength also vary with time after installation, in processes known as set-up (increasing resistance) or set-down (reducing resistance). If set-up occurs after initial installation it may be impossible to advance the piles after a delay or to extract temporary piles after use (Figure ). a) Pile Installation b) Increased Pile Capacity Topples Piler During Extraction Figure : Problems with Jacked Piling /

Existing Methods and Theory Jackson, A. Pile Jacking in Sand and. 7. The UWA-5 method () uses the results of cone penetration tests (CPTs) to predict pile capacity. Simplified forms of the UWA-5 expressions to relate the total base and shaft resistances Q b and Q s for a closed-ended tubular pile (Figure 3) to the modified CPT Area resistance q t are: A b Ground Q b = q A b = α q t b Equation 1 Q s LP = τ s = 1 h=l a q L t max h c D, tan δ dh Equation h= δ is the angle of friction between the soil and the pile shaft. α, a and c are empirical parameters which require calibration. The UWA-5 method provides values of the parameters to predict the medium-term capacity of driven tubular piles in sand, calibrated against a large database of load tests. This is currently the only case for which the method is validated. However, the equations and parameters can be attributed to physical phenomena occurring during installation and loading, so it is expected that other installation, soil and loading conditions can be considered by appropriate variation of these parameters (5). Embedded length L Height h above tip Perimeter P Diameter D Shaft resistance Q s Base resistance Q b Figure 3: Definition of Terms One phenomenon which may cause the parameters to vary in soil conditions other than sand is partial drainage. In low-permeability soils, installation of a pile induces excess pore water pressure around the pile tip. The magnitude of the induced pressure is dependent on the installation velocity, and it affects the base and shaft resistance. For example, positive excess pore water pressures generated by partially drained compression of the soil under the pile base will reduce the effective stress in the soil around the pile, and thus reduce the shear stress which can be mobilised. Figure shows how the pile installation resistance (point A) may therefore be different from the long-term drained capacity (point B), and may depend on the installation velocity v, the soil property c h (the coefficient of horizontal consolidation), and the pile diameter D. Whilst other phenomena such as viscous behaviour may cause the installation resistance to differ from the medium-term resistance, partial drainage is expected to be the primary cause of such behaviour in the soils considered in this project. 1 Normalised resistance: q b / q b,drained q t / q t,drained τ s / τ s,drained C B A Drained load test after dissipation Set-up Partially drained installation A B C Pile installation resistance Pile mediumterm capacity CPT installation resistance Normalised penetration velocity: vd/c h Figure : Variation of Installation Resistance with Installation Velocity (after ()) Partial drainage also provides a mechanism for the variation of capacity with time discussed above. After installation the induced pore water pressures dissipate away, reducing their affect on the pile capacity. This is represented by the transition from point A to point B in Figure. Again, other phenomena such as creep, aging and corrosion can cause the pile capacity to change with time, but 3/

Jackson, A. Pile Jacking in Sand and. 7. partial drainage is expected to be the primary cause of such behaviour in the soils and relatively short timescales considered in this project. Finally, the cone penetration test itself may also be partially drained, affecting its resistance q t (point C on Figure ). In general, a jacked pile designer therefore needs to be able to predict point A, point B and the behaviour in between, using information such as that provided by point C. A modified form of the UWA-5 method, adapted to account for the partially-drained behaviour shown in Figure, is suggested. This paper concentrates on predicting the partially-drained installation resistance (point A) from partially-drained CPT data (point C). Test Methodology Field tests were conducted at the Takasu test site in Kochi, Japan during July and December. 15m-long closed-ended cylindrical piles with an external diameter of 31.5mm were used. During each test, a pile was installed and extracted using an AT15 piler specially modified for these tests by Giken Seisakusho (Figure 5). The axial ground resistance was calculated using measurements from calibrated pressure cells in the hydraulic circuit driving the hydraulic cylinders of the piler, with a correction applied to account for the measured pile weight and hydraulic losses. Some of the tests used an instrumented pile in which a load cell in the pile base plate measured the base resistance separately from the shaft resistance, and pore pressure transducers measured the pore water pressures near the pile base. Pressure cells in hydraulic circuit measure force exerted by piler Data to datalogger Each test took place at an undisturbed part of the site. Figure shows the results of ground investigations conducted at the site. All the data suggests a transition at approximately 1.5m below ground; above this level the soil is primarily sand, and below it is primarily silt. Wall of pre-installed sheet piles provides reaction to test pile loads m BG 1..3 3. 5. q t [MPa] 1 Made ground Sandy gravel y sand u [MPa]. Sand 9. 1.5 y sand Piler chuck grips pile Coiled wire extensometer measures penetration of pile Figure 5: Test Arrangement Figure : Ground Investigation Data Further details of the test methodology and site conditions are given in (7) and (). 15. Sandy gravel 1m BG /

Results Jackson, A. Pile Jacking in Sand and. 7. Figure 7 shows the results of the field tests on the instrumented pile. These suggest the following observations: The measured base resistance is very consistent between tests, suggesting that the site is laterally homogeneous. However, there is a much greater variation in the shaft resistance. Other research (7) has shown that the shaft resistance is sensitive to small discrepancies in the installation process. For example, the variation may be caused by horizontal movements of the piler chuck imposed by the piler operator during installation to correct any minor misalignment of the pile (). Both the base and shaft resistance show a significant difference between the results in the sand and silt. Q b [kn] Q s [kn] 5 1 15 5 3 1 3 5 Tip Depth L [m] 1 1 1 1 Sand 1 1 a) Base Resistance b) Shaft Resistance Figure 7: Results of Tests on Instrumented Pile Figure shows the results of tests on piles installed at different velocities. As suggested by Figure, faster installations (in which the induced pore water pressures are expected to be higher) appear to mobilise a lower resistance. The long-term capacity after the excess pressures have dissipated is therefore expected to be higher than the installation resistance (set-up). Other tests not documented here did indeed show set-up occurring at the site (7). Pore pressure transducers on the instrumented pile also showed positive excess pressures; as described previously, this is consistent with a reduced resistance during installation. In the following section, the influence of soil condition is considered in more detail for the base and shaft resistance. Tip Depth [m] Average installation resistance of eight monotonic tests installed at v=mm/s. Average installation resistance of eleven monotonic tests installed at v=3mm/s. 1 1 Q b +Q s [kn] Figure : Results of Tests at Different Installation Velocities 5/

Analysis Jackson, A. Pile Jacking in Sand and. 7. The suitability of the modified UWA-5 method for predicting the installation resistance can be assessed by back-analysing the test results. Firstly, consider the base resistance. Figure 9 shows a plot of a rearrangement of Equation 1 using the measured installation base resistance. A value of the parameter c =. is assumed. Ignoring the data for very shallow installation, where the ground is expected to be variable, the results are reasonably consistent with an assumption of a single value of the parameter α for the sand stratum above 1.5mBG and another for the silt stratum below 1.5mBG. In both strata, the ratio of pile base to CPT resistance α is consistently less than predictions of the medium-term base resistance in sand from the UWA-5 method and by other researchers (9). This agrees with the general behaviour shown in Figure ; partial drainage reduces the pile resistance Tip Depth L [m] 1 1 1 α=q b /Aq t.... 1 Sand average average UWA-5 White & Bolton Sand Figure 9: Back-Analysis of the Base Resistance in comparison with the CPT resistance. The difference in the ratios between the sand and the silt is caused by the different relative positions of their CPT and pile installations on Figure. Back-analysis and predictions of the shaft resistance are more complicated than that of the base resistance, because the total shaft resistance is influenced by more than one stratum of soil. Each stratum has a different strength and drainage behaviour, and has had a different time for the dissipation of excess pore water pressures since their generation as the pile tip passed. However, an initial simplifying assumption is that the base and shaft resistances contributed by a given stratum of soil are influenced to the same extent by the local excess pore water pressure. This is logical, since it is the high stresses generated around the pile tip which cause both the base resistance and, to a large degree, the shaft resistance. Based on this approach, Equations 1 and can then be combined to give Equation 3, which analyses the shaft resistance a tan δ/α in terms of the measured base resistance in an.1..3. attempt to eliminate the effects of differences between pile and CPT installation: Tip Depth L [m] 1 1 1 c=-. Sand UWA-5 Figure 1: Back-Analysis of Shaft Resistance a tan δ α = P A b h=l h= Q s Q b max h D, c dh 1. Equation 3 Figure 1 shows values of the parameter a tan δ α derived from Equation 3 using the measured installation resistances. Scatter in the shaft resistance makes accurate analysis difficult. The ratio is close to that for medium-term resistances derived from the UWA-5 method, because the effect of partial drainage has been eliminated, leaving only the soil strength parameters. The small variation with depth is primarily due to a variation in soil strength rather than /

Jackson, A. Pile Jacking in Sand and. 7. in drainage condition. The assumption that the shaft resistance is affected by partial drainage to the same degree as the base resistance seems to give reasonable results. Conclusions and Recommendations Partially drained behaviour does appear to affect the installation resistance of jacked piles in sand and silt. Evidence for this is provided by observed differences between predicted medium-term capacities and measured installation resistances and by an observed influence of installation velocity on installation resistance. Whilst geotechnicians are used to considering the influence of partial drainage on silts, the influence on sands is less common and is caused by the relatively high speed of the installation process. In the soils tested, partial drainage during installation causes the installation resistance to be less than standard predictions of the medium-term pile capacity assuming drained sand conditions. A framework for understanding and predicting jacked pile installation resistance, based on the UWA-5 method, has been presented. A partial drainage curve, which is expected to look like Figure but which must be measured for all the soils involved, is used to predict a modified value of α at each tip depth. This allows each base resistance to be predicted from the corresponding CPT resistance using Equation 1. The shaft resistance is then predicted from an integration of this value along the pile shaft using Equation 3. As with the UWA-5 method, empirical calibration factors are required. Further research is needed to establish these values, but it is believed that much of the variation in the parameters can be obtained from site-specific ground investigations, leaving only CPT-to-pile conversion factors similar to those detailed in the UWA-5 method to be specified elsewhere. For example, measurement of the partial drainage behaviour is not currently common practice during site investigations, but it is readily achievable using modifications of CPT installations to include variable-rate or twitch tests (). An understanding of the partially drained installation also helps predict the longer term behaviour. It should be recognised that the reduction of the installation resistance to less than longer-term values is dependent on the installation rate used; installing more slowly, or including a delay in installation during which excess pore water pressures can dissipate, will increase the installation resistance. In low permeability soils even the CPT resistance may have been reduced by partial drainage during its installation, so the medium-term pile resistance may be higher than standard predictions from the CPT data assuming drained conditions. Other research not described here (7) has shown that very significant increases in capacity can occur within a few hours of installation. Partial drainage curves could be used to predict the significance of this behaviour for a new site. To summarise the findings directly relevant for pile designers and piler operators: Pile designers should be aware that the resistance to installing a pile is likely to be different from their predictions of the medium-term axial capacity. In soils undergoing set-up such predictions are likely to be a conservative (high) prediction of the installation resistance for specifying pilers, but they may be unconservative in some soils. Conversely, pile designers and operators should be aware that the practice of using the installation resistance as an indicator of the medium-term capacity may often be oversimplistic; in the soils tested it would be conservative (low), but in others it may not. Pile designers should be aware that further site investigation can be used to better understand the installation behaviour at sites where it is likely to be critical. 7/

Jackson, A. Pile Jacking in Sand and. 7. Piler operators should be aware of the possibility for set-up during delays to cause refusal or trapped piles, and partial drainage curves could be used to predict the significance of this behaviour for a new site. Piler operators should be aware that, somewhat counter-intuitively, faster installation causes a lower installation resistance. Acknowledgments The author would like to thank the following people for their contribution to the research: Dr D.J. White, Prof M.D. Bolton, Mr A.D. Deeks, Mr M. Gillard, Miss H. Dingle, Mr T. Nagayama, and all the staff and engineers at Giken who provided assistance, advice and support. This research was funded by Giken Seisakusho Ltd. as part of a long-term research collaboration with Cambridge University Engineering Department, which forms part of the activities of the International Press-in Association (www.press-in.org). References 1. [Online] http://www.giken.com.. [Online] http://www.grandarcade.co.uk/scheme/construction/vibration.htm. 3. White, D.J. and Deeks, A.D. Recent research into the behaviour of jacked foundation piles. Yokosuka. Proceedings of the International Workshop on Recent Advances of Deep Foundations. 7. pp. 3-.. Lehane, B.M., Schneider, J.A. and Xu, X. The UWA-5 method for prediction of axial capacity of driven piles in sand. Perth. Proceedings of the International Symposium on Frontiers in Offshore Geotechnics. A A Balkema, 5. pp. 3-9. 5. White, D.J. A general framework for shaft resistance on displacement piles in sand. London : Proceedings of the International Symposium on Frontiers in Offshore Geotechnics (ISFOG). Taylor & Francis, 5. pp. 97-73.. Silva, M.F. Numerical and physical models of rate effect in soil penetration. Cambridge University Engineering Department. 5. PhD Thesis. 7. Jackson, A. The Setup of Jacked Piles. Cambridge University Engineering Department. 7. MEng Thesis.. Dingle, H. The testing and analysis of jacked foundation piles. Cambridge University Engineering Department.. MEng Thesis. 9. White, D.J. and Bolton, M.D. Comparing CPT and base resistance in sand. Proceedings of the Institution of Civil Engineers: Geotechnical Engineering, Vol. 15(GEI). 5. pp. 3-1. /