Electric amplifier Types VT-VRRA1 and VT-VRPA1

Similar documents
Analog Command Value Card Type VT-SWKA-1

4/4-way servo solenoid directional control valves, directly operated, with electrical position feedback and on-board electronics (OBE)

Multi-function Card. 1 Description. 2 Technical data ESSK General. 1.2 Application example

2-way flow control valve Type 2FRM 6

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

EFC Frequency converters

Analog Amplifier Rexroth RA: Easy, user-friendly control of pumps and valves

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Pressure and flow control system

RISH CON - Hz. Salient Features : Application : Product Features: FREQUENCY TRANSDUCER

Steering unit. Table of contents. Features RE 11872/ Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min

Pressure reducing valve, direct operated, Type ZDR 6 D

Frequency Converter Fv

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

Option field bus: without bus with profibus DP. Design-Index (Subject to change)

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

Product Information Sheet UH28CS-12kV Hi Pot Tester

Heavy Duty Solenoid Controlled Access Lock. User Manual - Original Language Version

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

3-Way heavy duty flow control, with pressure compensated and solenoid controlled priority flow

2/2 and 3/2 Way Size 6 Seat Valves

Photovoltaic Solar Energy Unit EESFB

VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS

Fixed displacement vane pumps

Cable Plug acc. to DIN EN , Form A

Digital Clamp Axis Control for Hydraulic Molding Machines

MINI MCR-SL-R-UI(-SP)

Quick Connect. quick - simple - efficient.

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Three-phase monitoring relay CM-PFE

Combi switchbox with integrated 3/2 way pilot valve

Product Information Sheet UH36 Hi Pot Tester

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

Current and voltage measuring relays

Assisted lift operated 2/2-way solenoid valves Type EV250B

SWITCH-MODE POWER SUPPLY CONTROLLER PULSE OUTPUT DC OUTPUT GROUND EXTERNAL FUNCTION SIMULATION ZERO CROSSING INPUT CONTROL EXTERNAL FUNCTION

2-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

Disturbance Recoder SPCR 8C27. Product Guide

Example of use: Fuse for a solenoid valve. If the fuse is defective, no information is sent to the electronic component.

L-LAS-TB-CL serie. laser light curtains for inline measuring tasks

D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05

Combi B Alarm box. Mounting instructions

Power Supply and Indicator Unit Type Fig. 1 Type Mounting and Operating Instructions EB 9539 EN

Digital electronic drivers type E-RI-PES integral-to-valve format, for variable displacement axial piston pumps with alternate P/Q control

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

DCS Input/Output Relay Card Series

DSE5J /112 ED DIRECTIONAL VALVE WITH PROPORTIONAL CONTROL FEEDBACK AND INTEGRATED ELECTRONICS SERIES 10 SUBPLATE MOUNTING ISO (CETOP 05)

H/L = Power supply. FN = Nominal Frequency. RN = Rated value of output burden. UN = Nominal input voltage. IN = Nominal input current.

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

Electronic timer CT-AHD.12 OFF-delayed with 1 c/o (SPDT) contact

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

Diode Applications. by Kenneth A. Kuhn Sept. 1, This note illustrates some common applications of diodes.

Shutter Actuator Standard, 4-fold, 230 VAC, MDRC RA/S , GH Q R0111. ABB i-bus EIB

Inductive Proximity Sensors

Coils - Connectors. Coils Connectors. Summary. RE /03.16 Replaces: RE / Description

Controller Automation, Model II+

HERZ-Thermal Actuators

W150: Miniature photoelectric switch series with completely integrated electronics

HSP GmbH Zum Handwerkerhof Wendelstein Tel / Fax: / Web: HSP@hsshsp.de NTG-3000.

Automotive Sensor Simulator. Automotive sensor simulator. Operating manual. AutoSim

ACS-30-EU-EMDR-10-MOD

Hydraulic Control Technology for Wind Turbine Generators

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

CPU systron S S S 250c. systron S S S 250c. CPUs to the process modules. Stand-alone PLC

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Digital Pressure Measuring Instrument MDR480

Computer Controlled Generating Stations Control and Regulation Simulator, with SCADA SCE

Tilt switches N3 / N4... MEMS technology, one or two axis. Use. Options. + long lifetime and highly reliability due to mechanism-free MEMS technology

Electronics. Discrete assembly of an operational amplifier as a transistor circuit. LD Physics Leaflets P

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

Single sub-base valve

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

OPERATION MANUAL VALVE CHECKER G

SIMATIC. ET 200S distributed I/O 2AO I ST analog electronic module (6ES7135-4GB01-0AB0) Preface. Properties 1. Parameters 2.

Technical Information POWER PLANT CONTROLLER

Research RF Sputtering Packages

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

DALI DIM/CONVERTER CONTROL (DC NV) 1 10V (0-10 V) analog DALI Converter with (Multi-) Sensor-control and 1 and 2-Switch dim functions

NGSS Data Consolidator (DC)

Product data sheet. JUMO MIDAS Pressure Transmitter. Sales No. Order code JUMO AS /

Electric Rotary Actuator - On/Off or programmable control actuator

650W Single Output Power Supply

Electrical connection technologies Electrical connectors Electrical connectors with cable, series. Brochure

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

DEK-REL- 24/1/SEN. Extract from the online catalog. Order No.:

Product and functional description

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

mpm DIN CONNECTORS

SD Series. SD Series Rectifiers. EPC Energy & Power Conversion

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

Electronic Control Devices The European Product Catalogue 2007

Smart DeviceNet Remote I/O Terminals

Electronic timer CT-VBS OFF-delayed without auxiliary voltage, for DC contactors Data sheet

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Modular I/O System Analog and Digital Interface Modules

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Transcription:

Industrial Electric Drives Linear Motion and Service Mobile Hydraulics and Controls Assembly Technologies Pneumatics Automation Hydraulics RE 30 041/11.03 Replaces: 11.02 Electric amplifier Types VT-VRRA1 and VT-VRPA1 Series 2X Type VT-VRRA1 List of contents Contents Page Features 1 Ordering data 2 Preferred types 2 Front panel 2 Block diagram 3 Technical data 4 Device dimensions 5 Features Suitable for actuating directly operated servo solenoid valves with linear curve (type 4WRPH...L, series 2X, type 5WRP10...L, series 2X) Analog amplifiers in Eurocard format for installation in 19 rack Output stage with closed-loop control Enabling input Short-circuit-proof outputs Adjustment possibilities: valve zero Open-circuit detection for feedback signal cable Closed-loop position control with PID action Testing and service equipment Test box type VT-PE-TB2, see RE 30 064 Test adapter type VT-PA-3, see RE 30 070 2003 by Bosch Rexroth AG, Industrial Hydraulics, D-97813 Lohr am Main All rights reserved. This work may not be reproduced, stored, edited, copied or circulated in whole or in part, by electronic means or otherwise, without the prior written consent of Bosch Rexroth AG. Violations will result in liability for damages. This work has been compiled with the greatest care, and all the information therein has been checked to ensure correctness. We must reserve the right to make changes on the grounds of continual product development. No liability can be accepted for incomplete or inaccurate information. VT-VRRA1; VT-VRPA1 1/6 RE 30 041/11.03

Ordering data VT- V R A 1 - - / Hydraulic component For valves with electrical feedback = R V0 = Customer version Catalogue version Valve type p/q valve Servo solenoid valve = P = R Series 2X = Series 20 to 29 Actuation Analog = A Serial numbers for types 527 = NG 6 537 = NG 10 Preferred types (available at short notice) Material no. Type VT-VR.A1 For valve types 0 811 405 060 VT-VRRA1-527-20/V0 4WRPH 6 L-2X 0 811 405 061 VT-VRRA1-537-20/V0 4WRPH 10 L-2X 0 811 405 062 VT-VRPA1-537-10/V0 5WRP 10 L-2X Front panel RE 30 041/11.03 2/6 VT-VRRA1; VT-VRPA1

Block diagram with terminal assignment VT-VRRA1; VT-VRPA1 3/6 RE 30 041/11.03

Technical data (For device applications beyond the stated values, please consult us!) P.C.B. format (100 x 160 x approx. 35) mm (W x L x H) Europe format with front panel (7 modular spacings) Plug connector DIN 41 612 F 32 Ambient temperature 0 C +70 C, storage temperature min. 20 C; max. +70 C Weight m 0.25 kg Power supply U B to z 2 b 2 24 V DC nominal Battery voltage 21 40 V Rectified AC voltage U eff = 21 28 V (single-phase, full-wave rectification) Smoothing capacitor, separately to b 4, z 4 4,700 µf/63 V DC, only required if U B ripple >10 % Valve solenoid A/VA max. 2.7/40 (NG 6) 3.7/60 (NG 10) Current rating 1.7 A 2.7 A The current rating can rise at min. U B and long cable length to control solenoid Power consumption (typical) 37 W 55 W Input signal (setpoint) b 20: 0 ±10 V z 20: 0 ±10 V Difference amplifier (R i = 100 kω) Signal source Potentiometer 10 kω, ±10 V supply from b 32, z 32 (10 ma) or external signal source Output stage enable To z 16, U = 8.5 40 V, R i = 100 kω, LED (green) on front panel lights up Position transducer Supply b 30: 15 V z 30: +15 V Feedback signal b 22: 0 ±10 V, R i = 20 kω Feedback reference b 24 Solenoid output Clocked current regulator b 6 b 8 I max. = 2.7 A I max. = 3.7 A Length of amplifier to valve cables Solenoid cable: up to 20 m 1.5 mm 2 20 to 60 m 2.5 mm 2 Position transducer: 4 x 0.5 mm 2 (screened) Special features Open-circuit protection for feedback signal cable Closed-loop position control with PID action Clocked output stage Rapid energizing and de-energizing for fast response times Short-circuit-proof outputs Adjustment Zero via trimming potentiometer ±5 % LED displays Green: Enable Yellow: Feedback signal open circuit Red: Undervoltage (U B zu too low) Fault signal z 22: Open collector output to +U K Feedback signal open circuit max. 100 ma; no fault: +U K U B too low ±15 V stabilization Note Connect power zero b 2 and control zero b 12, b 14 or z 28 separately to central ground (neutral point). RE 30 041/11.03 4/6 VT-VRRA1; VT-VRPA1

Device dimensions (in mm) Connector DIN 41612 F 32 VT-VRRA1; VT-VRPA1 5/6 RE 30 041/11.03

Notes Bosch Rexroth AG Industrial Hydraulics D-97813 Lohr am Main Zum Eisengießer 1 D-97816 Lohr am Main Telefon 0 93 52/18-0 Telefax 0 93 52/18-23 58 Telex 6 89 418-0 email documentation@boschrexroth.de Internet www.boschrexroth.de The information contained herein is intended to serve purely as a product description. The information we have provided cannot be used as evidence of a particular aspect or of suitability for a particular purpose. Please note that our products are subject to the natural processes of ageing and wear. RE 30 041/11.03 6/6 VT-VRRA1; VT-VRPA1