100G Copper Proposal: Technical Feasibility From Connector Technology Standpoint. G. Oganessyan Jim McGrath MOLEX

Similar documents
Methode Electronics. DM-317-XXXX 40 Gbps QSFP+ Passive Cable RoHS COMPLIANT.

The ABC of Direct Attach Cables

HSSG copper objectives and five criteria

Quick Reference Guide High Speed Input/Output Solutions

Low Cost 100GbE Data Center Interconnect

Methode Electronics. DM-338-GG-XXXX Up to 120 Gbps CXP Passive Cable Assembly.

Uncompromising Integrity. Making 100Gb/s deployments as easy as 10Gb/s

Backplane Ethernet Study Group Market Drivers and Cost Considerations in Support of 40 inch average grade FR4 backplane links at 10Gb/s per lane

SO-CFP-ER-DWDM. CFP, 103/112 Gbps, DWDM tunable, SM, DDM, 20km SO-CFP-ER4-DWDM OVERVIEW PRODUCT FEATURES APPLICATIONS ORDERING INFORMATION

Transmission of High-Speed Serial Signals Over Common Cable Media

40 Gigabit Ethernet and 100 Gigabit Ethernet Technology Overview

100 GBE AND BEYOND. Greg Hankins NANOG52. Diagram courtesy of the CFP MSA. NANOG /06/14

Application Note. PCIEC-85 PCI Express Jumper. High Speed Designs in PCI Express Applications Generation GT/s

SO-QSFP28-LR4. QSFP, 100GBASE-LR, SM, DDM, 10km, LC SO-QSFP28-LR4 OVERVIEW PRODUCT FEATURES APPLICATIONS ORDERING INFORMATION DATASHEET 4.

Oracle Virtual Networking Overview and Frequently Asked Questions March 26, 2013

How to build a high speed PCI Express bus expansion system using the Max Express product family 1

Multi-Gigabit Interfaces for Communications/Datacomm

This application note is written for a reader that is familiar with Ethernet hardware design.

DTSB35(53)12L-CD20 RoHS Compliant 1.25G 1310/1550nm(1550/1310nm) 20KM Transceiver

Feasibility of 25 Gb/s Serial Transmission Over Copper Cable Assemblies

The Ethernet Roadmap Applications, servers, optics, and switches

Selecting the Optimum PCI Express Clock Source

10/100BASE-T Copper Transceiver Small Form Pluggable (SFP), 3.3V 100 Mbps Fast Ethernet. Features. Application

VPX Implementation Serves Shipboard Search and Track Needs

LONGLINE QSFP+ SR4. Features. Applications. Description. Page 1 of 13

XMC Modules. XMC-6260-CC 10-Gigabit Ethernet Interface Module with Dual XAUI Ports. Description. Key Features & Benefits

White Paper: CEI-25G-LR and CEI-28G-VSR Multi-Vendor Interoperability Testing at the 2012 ECOC Exhibition

Interfacing Intel 8255x Fast Ethernet Controllers without Magnetics. Application Note (AP-438)

MICRO SFP+ CONNECTOR & CABLE ASSEMBLY

xxx Dual AMC box Datasheet v1.1( )

PCIE 16X CONNECTOR BOARD ROUTING RECOMMENDATIONS TABLE OF CONTENTS

Advancements in Beamformer and Correlator Optical Backplane. Dr. Grant Hampson 11 th January 2013 URSI Boulder

PCI Express Impact on Storage Architectures and Future Data Centers. Ron Emerick, Oracle Corporation

LONGLINE 10Gbps 10km SFP+ Optical Transceiver

Evolution of Ethernet Speeds: What s New and What s Next

Direct Attach Cable with Micro Coaxial Wire for Data Center

OPT SERIAL TO FIBER OPTIC CONVERTER

EDUCATION. PCI Express, InfiniBand and Storage Ron Emerick, Sun Microsystems Paul Millard, Xyratex Corporation

Maximizing Server Storage Performance with PCI Express and Serial Attached SCSI. Article for InfoStor November 2003 Paul Griffith Adaptec, Inc.

PL-277x Series SuperSpeed USB 3.0 SATA Bridge Controllers PCB Layout Guide

RoHS Compliant Copper Small Form Factor Pluggable (SFP) Transceiver for Gigabit Ethernet

Technical Innovation. Salland delivers fully Integrated Solutions for High Volume Testing of Ultra-fast SerDes Applications

HUBER+SUHNER AG Phil Ward

1000BASE-T and 10/100/1000BASE-T Copper SFP Transceiver

PCI Express IO Virtualization Overview

PRODUCT SPECIFICATION

DD160 and DD620 Hardware Overview

Produto: 1.25Gbps SFP Bi-Directional Transceiver, 10km Reach (1310nm TX/1550nm RX) Modelo: V7-WDM-0210AD Documentação: Técnica/Datasheet

How To Get 40G Over Copper (Wired) And 40G On Coaxian (Wireless) Cable (Wired Coaxian) (Wired Cable) (Wireline) (Powerline) And 50G Over Coaxian Cable (Wire Coaxian

Upgrading Path to High Speed Fiber Optic Networks

A+ Guide to Managing and Maintaining Your PC, 7e. Chapter 1 Introducing Hardware

PCIeBPMC (PCI/PCI-X Bus Compatible) Bridge based PCIe and PMC Compatible Adapter Carrier Front View shown with 1 installed fans model # PCIeBPMC-FAN2

XFP Optical Receiver, 80km Reach

10/100/1000BASE-T SFP Transceiver

Oracle Big Data Appliance: Datacenter Network Integration

PCI Express Impact on Storage Architectures. Ron Emerick, Sun Microsystems

Metallized Particle Interconnect A simple solution for high-speed, high-bandwidth applications

Oracle Exalogic Elastic Cloud: Datacenter Network Integration

PCI Express and Storage. Ron Emerick, Sun Microsystems

Datacenter Performance

155Mbps DFB SFP Optical Transceiver, 120km Reach

Cloud-Based Apps Drive the Need for Frequency-Flexible Clock Generators in Converged Data Center Networks

Explore Efficient Test Approaches for PCIe at 16GT/s Kalev Sepp Principal Engineer Tektronix, Inc

8 Gbps CMOS interface for parallel fiber-optic interconnects

AMP NETCONNECT Data Center Cabling Solutions

Migration Strategy for 40G and 100G Ethernet over Multimode Fiber

Security & Surveillance Cabling Systems

Welcome to Pericom s PCIe and USB3 ReDriver/Repeater Product Training Module.

Computer buses and interfaces

HIGHSPEED ETHERNET THE NEED FOR SPEED. Jim Duran, Product Manager - Americas WHITE PAPER. Molex Premise Networks

Route Processor. Route Processor Overview CHAPTER

Interposers, Probes and Adapters for Teledyne LeCroy PCI Express Systems

PHY Feasibility Study for One or Two pairs RTPGE

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

KOM200. Industrial Serial to Fiber Media Converter. User s Manual

10Gb/s SFP+ LRM 1310nm FP with PIN Receiver 220meters transmission distance

The migration path from 10G to 40G and beyond for InstaPATCH 360, InstaPATCH Plus and ReadyPATCH installations

LONGLINE 40km XFP Optical Transceiver

The Evolution of Copper Cabling Systems from Cat5 to Cat5e to Cat6 Copper Cabling Standards and Technical Aspects

Application Note: How to Connect a Lantronix Embedded Module to a Wired Ethernet Port

Active Optical Cables for InfiniBand QDR and FDR. SC11 Seattle, WA

Key features: About this backplane:

PCI EXPRESS: AN OVERVIEW OF PCI EXPRESS, CABLED PCI EXPRESS, AND PXI EXPRESS

DD670, DD860, and DD890 Hardware Overview

Product Specification. 1000BASE-T RoHS Compliant Copper SFP Transceiver FCLF8520P2BTL / FCLF8521P2BTL / FCLF8522P2BTL

PCI Express Impact on Storage Architectures and Future Data Centers. Ron Emerick, Oracle Corporation

First 40 Giga-bits per second Silicon Laser Modulator. Dr. Mario Paniccia Intel Fellow Director, Photonics Technology Lab

PCI Express Supersedes SAS and SATA in Storage

Ethernet 301: 40/100GbE Fiber Cabling and Migration Practices

Chapter 5 Cubix XP4 Blade Server

Next Generation 100G Client Optics

Managing Connector and Cable Assembly Performance for USB SuperSpeed

Bus Interconnect Evolution in embedded computing

Optical Interconnect Technology for High-bandwidth Data Connection in Next-generation Servers

Auxiliary equipment for communication with the EuroProt protective devices

SFP+ DWDM Dual LC 10G SMF 40km Transceiver. Features. Applications APPLIED OPTOELECTRONICS, INC. A7ELXDxxEDMA0609

10GBASE-T SFP+ Transceiver Module: Get the most out of your Cat 6a Cabling

40 Gigabit Ethernet and 100 Gigabit Ethernet Technology Overview

155Mbps/1250Mbps SFP Bi-Directional Transceiver, 40km Reach 1310nm TX / 1550 nm RX

Transcription:

100G Copper Proposal: Technical Feasibility From Connector Technology Standpoint G. Oganessyan Jim McGrath MOLEX March 2007

Background To facilitate next generation Ethernet, all parts of the system must be considered Data center links must be included to fully facilitate next generation Ethernet Data center links are typically implemented with copper cable Copper interconnect technology is currently available operating at 10 Gbps per differential pair This presentation provides an overview of this technology and available form factors

Overview of Current Technology Interconnect technology has demonstrated 10 Gbps per pair capability Copper cables can be plugged directly to the host connector for data center links For longer runs, a fiber transceiver can be plugged into the copper host connector providing capability for a fiber link

Overview of Current Technology Solutions currently exist enabling 10 Gbps serial lane rates over 10m Twinax cable: QSFP Pluggable (electrical/optical) 4x10 Gbps in a small form factor. 10x10 Gbps Pluggable Interconnect (demonstrated up to 10 m)

4 Lane Form Factor (40G 4x10 available today, extendable to 100G 4x25)

QSFP Quad Small Form-factor Pluggable The QSFP MSA was released 12/4/2006 -The MSA defines an 8 Differential Pair (4x) Pluggable Copper Cable & Optical Module - Each pair is 10Gb capable 38 ckt Connector (same as PCI Express 4x) 4x Optical Module 4x Passive Pluggable Cable 4x Active Pluggable Cable

QSFP 1U Rack Mount Enclosure 16 x 4 = 64 1x Lanes 16 over 16 = 32 x 4 = 128 1x Lanes 16.00 1.75

10 Lane Form Factor (100 Gbps 10x10 solution)

10 Lane Pluggable Interconnect 80 ckt integrated press-fit connector/cage assembly provides 12 differential channels: 10 lanes of 10 Gbps, as well as additional circuits for power, sidebands, coding, clocks, etc. Host interconnect can accept copper or optical cable solutions EMI performance proven to 10 Gbps. Receive Group Transmit Group

10 Lanes On a 1U Blade Figures compare the number of available lanes that fit within a typical 1U panel 406.4 mm (16 ) width PCB 44.45 mm (1.75 ) standard 1U overall height Pluggable 80 ckt. connectors utilize 1/3 of the rack space of traditional I/O s 240 lanes in 1U form factor (24) 80 Ckt. Connectors Yields 240 1x lanes per 1U 1.75 240 1X Lanes per 1U 16.00

Example HSSG 10 Lane Pin Out 80 Vcc 78 Rxp10 76 Rxn8 74 Vcc 72 Rxp6 70 Rxn4 68 Vcc 66 Rxp2 64 62 Vcc ID3 79 Rxn10 77 Vcc 75 Rxp8 73 Rxn6 71 Vcc 69 Rxp4 67 Rxn2 65 Vcc 63 61 SLOT B 60 G 58 Rxp9 56 Rxn7 54 G 52 Rxp5 50 Rxn3 48 G 46 Rxp1 44 42 G (upper) ID2 59 Rxn9 57 G 55 Rxp7 53 Rxn5 51 G 49 Rxp3 47 Rxn1 45 G 43 41 40 G 38 Txp10 36 Txn8 34 G 32 Txp6 30 Txn4 28 G 26 Txp2 24 22 G ID1 39 Txn10 37 G 35 Txp8 33 Txn6 31 G 29 Txp4 27 Txn2 25 G 23 21 SLOT A 20 G 18 Txp9 16 Txn7 14 G 12 Txp5 10 Txn3 8 G 6 Txp1 4 2 G (lower) ID0 19 Txn9 17 G 15 Txp7 13 Txn5 11 G 9 Txp3 7 Txn1 5 G 3 1 Transmit Receive Power Side Bands Transmit pairs could be aggregated in lower slot A to optimize isolation within the channel Signal pairs can be optimized for direct ASIC routing from the connector Power pins in upper slot B could enable active-equalized cable assemblies Twelve sideband signal pins provide capability for cable identification, clocks or other functionality

Link Reach Extension (Active) Link extensions to up to 30m have been demonstrated using active RX equalization and/or EDC in the module. Several vendors (Quellan, Phyworks, Vitesse, TI, Scintera, others) have lowpower solutions that have been shown to work successfully. See Appendix for details. An example of 25-30m 10G serial link solution would be a QSFP module with a lane extender module and a high-performance 24 AWG cable.

Doing 100 Gbps 100 Gbps with small number of aggregate lanes (5x20 or 4x25) is possible using current hardware by employing signaling schemes alternative to NRZ. PAM4 and Duobinary are possible candidates. Signal Integrity/Crosstalk data supports 10 Gbps NRZ operation, extendable to 20-25 Gbps Duobinary seems particularly promising: it allows 20-25 Gbps transmission over 10-12 Gbps NRZ channels, with low coding, power and SNR penalty. For details refer to: 25 Gbit/s electrical duobinary transmission over FR-4 backplanes Adamiecki, A. Duelk, M. Sinsky, J.H. Lucent Technol., Bell Labs., Holmdel, NJ, USA; Electronics Letters, Volume: 41, Issue 14.

Conclusion 100 Gbps copper Ethernet within data center is feasible in a cost-effective solution. Currently available interconnect hardware providing 10 Gbps serial links can be utilized in parallel for copper 100G Ethernet by using high-performance components and adjusting the signaling scheme.

APPENDIX A: Crosstalk data for 4 Lane and 10 Lane Solutions

10 Lane Crosstalk Data: Test Setup Tested Implementation: x16 PCIe (ipass + ) connector

10 Lane Crosstalk Data: NEXT (7m 24 AWG Cable)

10 Lane Crosstalk Data: FEXT (7m 24 AWG Cable)

10 Lane Crosstalk Data: Power-Sum Xtalk PSXT (7m 24 AWG Cable)

10 Lane Crosstalk Data: ICR (7m 24 AWG Cable)

4 Lane Crosstalk Data: NEXT & FEXT (10m 24 AWG Cable) NEXT FEXT

APPENDIX B: An Example of EDC Technology Enabling 10G Serial Transmission Materials courtesy of Phyworks LTD

~26 db Cable Loss (28AWG, 10m @ 5Ghz) Data from Chris DiMinico MC Communications

~25 db Backplane loss 1m @ 5Ghz 2 Molex I-Trac Connectors Molex Reference Backplane Port E2 left, G2 right Similar Loss Characteristic to 10m Cable

Available Measurements Molex Reference Backplane Channel 25 db loss at 5 GHz 3 NEXT interferers 1 FEXT interferer Phyworks 1066 Pre-emphasis TX (fixed no training) Same pre-emphasis setting provides error free back to back case Blind adaptive equalizing RX Channel Reasonably Comparable to 10m Cable Further work planned with actual cables

Channel Output No Pre-Emphasis

Channel Output With Pre-Emphasis

BER Contour Eye (10-3, 10-6, 10-9 ) No Errors in >10 14 Bits Eye Opening Extracted at Slicer Output of equalizer Sampling level and time adjusted and BER measured PRBS31

Summary Silicon technology for 10 Gbps is available today Measurements of correlated channel encouraging Longer cable reaches and higher data rates merit further investigation For more information contact Paul Denny paul.denny@phyworks-ic.com