EU Declaration of Conformity

Similar documents
What is ATEX? The European Regulatory Framework for Manufacture, Installation and Use of Equipment in Explosive Atmospheres

Fisher 3610J and 3620J Positioners and 3622 Electro-Pneumatic Converter

Fisher 3710 and 3720 Positioners and 3722 Electro-Pneumatic Converter

BULLET. Description. Features. WirelessHART Adapter for Use with Wired HART Field Devices

FGM 160 ATEX EC type examination certificate

Fisher 846 Electro-Pneumatic Transducer


Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

2.12. page Products for Explosion hazardous Environment

SEISMIC VELOCITY TRANSDUCER T1-40

Terminal Boxes in Glass Fiber Reinforced Polyester (GRP)

Rosemount 752 FOUNDATION fieldbus Remote Indicator

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

EXPLOSION-PROOF EMERGENCY LIGHTING FIXTURE FOR FLUORESCENT LAMP EVF-..-EL SERIES

Floodlight Range Installation Guide

FCS-MBx-SG Megablock series*

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Inductive slot sensor

LeI E. Henri CERVELLO

Fisher D3 Control Valve

Retractable Housings. InTrac 781 / 784 Versatile and Rugged For the Toughest Process Conditions INGOLD

Technical Data. Dimensions

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0


Compact pressure switch Flameproof enclosure Ex d Model PCA

Technical Data. General specifications Switching element function Rated operating distance s n 15 mm

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

CERTIFICATE OF COMPLIANCE

Instructions for Safe Use

3500/15 Power Supply Bently Nevada* Asset Condition Monitoring

ATEX Installation Instructions for Micro Motion ELITE CMFS Sensors

Hazardous Area Classifications and Protections

and Accelerometers

Fisher 657 and 667 Diaphragm Actuators

Control and Distribution Boxes made of Stainless Steel Series 8150

Series 8146/5-V37 and Series 8150/5-V37

IECEX CERTIFICATION SCHEMES VERSUS ATEX DIRECTIVES

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 8 mm

Ex q Powder Filling. This is a technique primarily used for oil filled switch-gear. The spark is formed under oil and venting is controlled.

UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard.

EX-TECH SAS CP/PB 150 EXPLOSIONPROOF MANUAL CALL POINT/ PUSH BOTTON TECHNICAL MANUAL

Series 3730 Type Electropneumatic Positioner

Control- and feedback head for integrated mounting on Robolux valves Type 2036

SELECTION GUIDE. bzg - Zener Barrier.

Making sense of Intrinsic Safety and Intrinsically Safe Tools

Threaded resistance thermometer Model TR10-C, with protection tube

Fisher 646 Electro Pneumatic Transducer

Series 3730 Type Electropneumatic Positioner with FOUNDATION fieldbus communication

Plug and Socket Devices CES 63 A Series 8579

Flameproof Audible Signal 115 db (A) Series YA90

Machinery Directive EMC Directive Low Voltage Directive /EN/1096/B

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Hazardous Area Classifications and Protections

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

Brochure. Light fittings, floodlights and beacons New LED range for hazardous areas

Linear Luminaire with LED Series EXLUX 6402/2

97300 NAMUR series, 3/2 & 5/2 Indirect solenoid actuated spool valve

Baumann Little Scotty Bronze Control Valve

IIB+H2 Flameproof Ex d enclosures EJB Aluminium & Stainless steel

Inductive sensor NI10-M18-Y1X-H1141

Flow switches Series AD/VH

Fisher 3582 and 3582i Positioners and 582i Electro-Pneumatic Converter

Hazardous Locations Training

Terminal Box. Specifications TNCN

Fisher 2625, 2625SST, and 2625NS Volume Boosters

EX 2000/EX 2000 C/ GD 2000/GDP

Technical Data. Dimensions

Comparison Between ATEX 94/9/EC. and NFPA 85

2/2 and 3/2 Solenoid Control Valves

ATEX 94/9/EC Directive Declaration of Conformity: Tips and FAQ s

David O Brien, CMP Products (David.OBrien@cmp-products.com)

CUSTOMS UNION. CUSTOMS UNION CERTIFICATE OF CONFORMANCE No. RU C-DE.ГБ05.В Series RU No

Latest news on explosion protection

Rosemount 248 Temperature Transmitter

M Series Manual Handwheel Gear Actuators for Fisher Butterfly Valves

Explosion Protection. Industrial Automation and Drive Technologies. Products and systems for use in hazardous areas. Brochure April 2008

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

Fisher FIELDVUE DVC2000 Digital Valve

EC Declaration of Conformity March 15, Series 100 and 200 High Performance Current & Voltage Pressure Transducers

ATEX GUIDELINES (FIRST EDITION)

1756 ControlLogix Chassis Specifications

Technical data sheet TDS0070

RTX 1000 Series. Versatile Transmitters for a World of Pressure. GE Measurement & Control Solutions. Features

Rosemount 751 Field Signal Indicator

Connection technology from ifm.

Solenoid Valve Island Type 3965

1788 Linking Device Specifications

TX2123 RS485 TO ETHERNET ADAPTOR

3500/62 Process Variable Monitor

Fisher FIELDVUE DVC6200 SIS Digital Valve Controller for Safety Instrumented Systems (SIS)

Dräger Communication Systems

Explosion proof enclosures

ngenieros Ingenieros Asociados De Control S.L.


AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

Plug and Socket Devices SolConeX 16 A Series 8570

Worcester DS/DM Series UltraSwitch Switch box

Fluxi 2000/TZ Turbine Gas Meter

S-series SQ Controller

Rosemount 3051 Pressure Transmitter. Rosemount 3051CF Series Flowmeter Transmitter

Transcription:

EU Declaration of Conformity We, the manufacturer, Emerson Process Management Fisher Controls International LLC 205 South Center Street Marshalltown, Iowa 50158 USA declare under our sole responsibility that the following products considered as, Non-electrical instrumentation (pneumatic positioners, controllers, transmitters, volume boosters, and switches) to which this declaration relates, is in conformity with the provisions of the following European Community Directives, including the latest amendments, as shown in the attached schedule. Assumption of conformity is based on the application of the harmonized standards and, when applicable or required, a European Community Notified Body certification, as shown in the attached schedule. Danny Nelson Vice President Instrument Business Unit 14-March-2016 Date European Contact Emerson Process Management Group Services SAS Rue Paul-Baudry B.P. 10 68701 Cernay Cedex France EDOCS ID: FCS_22 Page 1 of 2

ATEX Directive 2014/34/EU (Applicable only if this mark appears on the product) Non-electrical instrumentation Group II Category 2 GD Equipment is marked as follows: II 2 G D TX Standards used: EN13463-1:2009, EN1127-1:2011 The Technical Documentation has been submitted and retained by the Notified Body: SGS Baseefa Limited Notified Body Number: 1180 Rockhead Business Park Staden Lane, Buxton, Derbyshire SK17 9RZ United Kingdom PED Directive 2014/68/EU Declaration of SEP Models: Non-electrical instrumentation (pneumatic positioners, controllers, transmitters, volume boosters, and switches) The above equipment was designed and manufactured in accordance with Sound Engineering Practice (SEP) and is in compliance with Article 4 paragraph 3 of the PED Directive. Therefore the equipment cannot bear the CE mark related to PED compliance. However, the equipment may bear the CE mark to indicate compliance with other applicable EU Directives. EDOCS ID: FCS_22 Page 2 of 2

EU Declaration of Conformity We, the manufacturer, Emerson Process Management Fisher Controls International LLC 205 South Center Street Marshalltown, Iowa 50158 USA declare under our sole responsibility that the following product(s); Electro-pneumatic Converters 3622, 3722 582i Electro-pneumatic Transducer 646 Electro-pneumatic Positioner 3661 to which this declaration relates, is in conformity with the provisions of the following European Community Directives, including the latest amendments, as shown in the attached schedule. Assumption of conformity is based on the application of the harmonized standards and, when applicable or required, a European Community Notified Body certification, as shown in the attached schedule. Danny Nelson Vice President Instrument Business Unit 14-March-2016 Date European Contact Emerson Process Management Group Services SAS Rue Paul-Baudry B.P. 10 68701 Cernay Cedex France EDOCS ID: FCS_29 Page 1 of 3

EMC Directive 2014/30/EU All models EN 61326-1:2013 PED Directive 2014/68/EU Declaration of SEP Models: 3622, 3722, 582i, 646, 3661 The above equipment was designed and manufactured in accordance with Sound Engineering Practice (SEP) and is in compliance with Article 4 paragraph 3 of the PED Directive. Therefore the equipment cannot bear the CE mark related to PED compliance. However, the equipment may bear the CE mark to indicate compliance with other applicable EU Directives. ATEX Directive 2014/34/EU (Applicable only if this mark appears on the product) Certificate LCIE03ATEX6001X Group II Category 1 GD Intrinsically Safe & Dust 3622, 3722 Ex ia IIC T4(Ta 82 C), T5(Ta 62 C), T6(Ta 47 C) Ga Ex ia IIIC T120ºC(Ta 82 C) / T100ºC(Ta 62 C) / T85ºC(Ta 47 C) Da, IP64 582i Ex ia IIC T4(Ta 71 C), T5(Ta 62 C), T6(Ta 47 C) Ga Ex ia IIIC T109ºC(Ta 71 C) / T100ºC(Ta 62 C) / T85ºC(Ta 47 C) Da, IP64 646 Ex ia IIC T4(Ta 71 C), T5(Ta 40 C) Ga Ex ia IIIC T155ºC(Ta 71 C) / T124ºC(Ta 40 C) Da, IP64 3661 Excludes Dust Ex ia IIC T4(Ta 82 C), T5(Ta 62 C), T6(Ta 47 C) Ga Standards used: EN60079-0:2012, EN60079-11:2012 Certificate KEMA04ATEX2137X Group II Category 2 GD Flameproof & Dust 582i, 646 Ex d IIC T6(Ta 71ºC) Gb Ex tb IIIC T74ºC(Ta 71ºC) Db 3622, 3722 Ex d IIC T5(Ta 82ºC) Gb Ex tb IIIC T82ºC(Ta 79ºC) Db Standards used: EN60079-0:2012, EN60079-1:2007, EN60079-31:2009 Certificate LCIE03ATEX6002X Group II Category 3 GD Type n & Dust 3622, 3722 Ex na IIC T6(Ta 82 C) Gc Ex tc IIIC T85ºC(Ta 82 C) Dc, IP64 582i Ex na IIC T6(Ta 71 C) Gc Ex tc IIIC T85ºC(Ta 71 C) Dc, IP64 646 Ex na IIC T6(Ta 71 C) Gc Ex tc IIIC T85ºC(Ta 71 C) Dc, IP64 3661 Excludes Dust Ex na IIC T6(Ta 82 C) Gc Standards used: EN60079-0:2012, EN60079-15:2010, EN60079-31:2009 ATEX Notified Body for EC-Type Examination Certificate(s) LCIE Laboratoire Central des Industries Electriques Notified Body Number: 0081 33 Avenue du General Leclerc BP 8 F92233 Fontenay-aux-Roses cedex EDOCS ID: FCS_29 Page 2 of 3

France DEKRA Certification B.V. Notified Body Number: 0344 Utrechtseweg 310 6812 AR Arnhem P.O. Box 5185 6802 ED Arnhem The Netherlands ATEX Notified Body for Quality Assurance SGS Baseefa Limited Notified Body Number: 1180 Rockhead Business Park Staden Lane, Buxton, Derbyshire SK17 9RZ United Kingdom EDOCS ID: FCS_29 Page 3 of 3

EU Declaration of Conformity We, the manufacturer, Emerson Process Management Fisher Controls International LLC 205 South Center Street Marshalltown, Iowa 50158 USA declare under our sole responsibility that the following product; Digital Level Controller DLC3020F to which this declaration relates, is in conformity with the provisions of the following European Community Directives, including the latest amendments, as shown in the attached schedule. Assumption of conformity is based on the application of the harmonized standards and, when applicable or required, a European Community Notified Body certification, as shown in the attached schedule. Danny Nelson Vice President Instrument Business Unit 14-March-2016 Date European Contact Emerson Process Management Group Services SAS Rue Paul-Baudry B.P. 10 68701 Cernay Cedex France EDOCS ID: FCS_38 Page 1 of 2

EMC Directive 2014/30/EU All models EN 61326-1:2013 EN61326-2-3:2006 ATEX Directive 2014/34/EU (Applicable only if this mark appears on the product) Certificate LCIE10ATEX3091X Group II Category 1 GD Intrinsically Safe & Dust DLC3020F Ex ia IIC T5(Ta 80 C), T6(Ta 73 C) Ga Ex ia IIIC T87ºC(Ta 80 C) / T80ºC(Ta 73 C) Da, IP66 Standards used: EN60079-0:2012 + A11:2013, EN60079-11:2012 Certificate LCIE10ATEX3076 Group II Category 2 GD Flameproof & Dust DLC3020F Ex d IIC T5(Ta 80ºC), T6(Ta 73 C) Gb Ex tb IIIC T87 C(Ta 80 C) / T80 C (Ta 73 C) Db, IP66 Standards used: EN60079-0:2012 + A11:2013, EN60079-1:2007, EN60079-31:2014 Certificate LCIE10ATEX1010 Group II Category 3 GD Type n & Dust DLC3020F Ex na IIC T5(Ta 80 C), T6(Ta 73 C) Gc Ex tc IIIC T87 C(Ta 80 C) / T80 C(Ta 73 C) Dc, IP66 Standards used: EN60079-0:2012 + A11:2013, EN60079-15:2010, EN60079-31:2014 ATEX Notified Body for EC-Type Examination Certificate(s) LCIE Laboratoire Central des Industries Electriques Notified Body Number: 0081 33 Avenue du General Leclerc BP 8 F92233 Fontenay-aux-Roses cedex France ATEX Notified Body for Quality Assurance SGS Baseefa Limited Notified Body Number: 1180 Rockhead Business Park Staden Lane, Buxton, Derbyshire SK17 9RZ United Kingdom EDOCS ID: FCS_38 Page 2 of 2

EU Declaration of Conformity We, the manufacturer, Emerson Process Management Fisher Controls International LLC 205 South Center Street Marshalltown, Iowa 50158 USA declare under our sole responsibility that the following product(s); Electric Actuator easy-drive to which this declaration relates, is in conformity with the provisions of the following European Community Directives, including the latest amendments, as shown in the attached schedule. Assumption of conformity is based on the application of the harmonized standards and, when applicable or required, a European Community Notified Body certification, as shown in the attached schedule. Michael W McCarty Vice President Advanced Research and Marketing 26-May-2016 Date European Contact Emerson Process Management Group Services SAS Rue Paul-Baudry B.P. 10 68701 Cernay Cedex France EDOCS ID: FCS_55 Page 1 of 2

EMC Directive 2014/30/EU All models EN 61326-1:2013 ATEX Directive 2014/34/EU (Applicable only if this mark appears on the product) Certificate SIRA12ATEX1168X Group II Category 2 G Flameproof easy-drive Ex db IIA T670ºC) Gb Standards used: EN60079-0:2012/A11:2013, EN60079-1:2014 ATEX Notified Body for EC-Type Examination Certificate(s) SIRA Certification Service Notified Body Number: 0518 Unit 6, Hawarden Industrial Park, Hawarden, CH5 3US United Kingdom ATEX Notified Body for Quality Assurance SGS Baseefa Limited Notified Body Number: 1180 Rockhead Business Park Staden Lane, Buxton, Derbyshire SK17 9RZ United Kingdom EDOCS ID: FCS_55 Page 2 of 2

EU Declaration of Conformity We, the manufacturer, Emerson Process Management Fisher Controls International LLC 205 South Center Street Marshalltown, Iowa 50158 USA declare under our sole responsibility that the following product(s); Electro-pneumatic Transducer 546, 546NS to which this declaration relates, is in conformity with the provisions of the following European Community Directives, including the latest amendments, as shown in the attached schedule. Assumption of conformity is based on the application of the harmonized standards and, when applicable or required, a European Community Notified Body certification, as shown in the attached schedule. Josh Wilford Vice President Engineered Products 11-July-2016 Date European Contact Emerson Process Management Group Services SAS Rue Paul-Baudry B.P. 10 68701 Cernay Cedex France EDOCS ID: FCS_67 Page 1 of 2

EMC Directive 2014/30/EU All models EN 61326-1:2013 PED Directive 2014/68/EU Declaration of SEP Models: 546, 546NS The above equipment was designed and manufactured in accordance with Sound Engineering Practice (SEP) and is in compliance with Article 4 paragraph 3 of the PED Directive. Therefore the equipment cannot bear the CE mark related to PED compliance. However, the equipment may bear the CE mark to indicate compliance with other applicable EU Directives. EDOCS ID: FCS_67 Page 2 of 2