Antti Leskelä Fortum Engineering Ltd PO Box 10, FORTUM, Finland Tel

Similar documents
[4] SA1.2 The student demonstrates an understanding of the processes of science by observing,

9.00 THE USE OF HUNTER LAND DRAINAGE PERFORATED PIPES. Hunter Underground Systems

Christine E. Hatch University of Nevada, Reno

A high-tech measurement system to evaluate river restoration

Treatment Practice for Controlling Water Damage in the Annular Space of Shaft Freezing Hole

METHOD OF TEST FOR DETERMINATION OF PERMEABILITY OF GRANULAR SOILS

WEATHERING, EROSION, AND DEPOSITION PRACTICE TEST. Which graph best shows the relative stream velocities across the stream from A to B?

Watershed Works Manual

Preventing water damage in the basement

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance

HEAT PUMP FOR DISTRICT COOLING AND HEATING AT OSLO AIRPORT, GARDERMOEN

EXPLAINING GROUNDWATER AND WATER WELLS

Soils, Foundations & Moisture Control

RIPRAP From Massachusetts Erosion and Sediment Control Guidelines for Urban and Suburban Areas

DETECTION AND LOCALIZATION OF MICRO LEAKAGES IN

Permeable Pavement Construction Guide

Attachment G-1: Pit Latrine Diagram. Fig E.1a: Pit Latrine. Fig E.1b: Plan View of Twin Pits

Emergency Spillways (Sediment basins)

STRUCTURES Excavation and backfill for structures should conform to the topic EXCAVATION AND BACKFILL.

Use of Fly ash from KKAB, for sealing of landfills

Engineering Geological Asset Management for Large Dams. Yasuhito SASAKI (1)

Fiberstars Mini Lighted Laminar Flow Fountains

Underground Injection Control Storm Water Information

Grade 4 Standard 1 Unit Test Water Cycle. Multiple Choice. 1. Where is most water found on Earth? A. in glaciers B. in lakes C. in rivers D.

Fiberstars Lighted Laminar Flow Fountain Installation Manual

Ontario Fire Code SECTION 5.13 DIP TANKS. Illustrated Commentary. Office of the Ontario Fire Marshal

Minimizes sediment and debris from entering storm drains that lead to waterways and watercourses.

The ATES Project at Stockholm Arlanda Airport - Technical Design and Environmental Assessment

MAINTENANCE OF SMALL WATER SUPPLY, SANITATION AND IRRIGATION SCHEMES

MOBILE HOME LAW. Revised November 2001

Name: PLSOIL 105 & 106 First Hour Exam February 27, Part A. Place answers on bubble sheet. 2 pts. each.

COSMOS 2012: Earthquakes in Action COSMOS 2012

WATER CONSERVATION TECHNICAL BRIEFS

N4385A / N4386A Distributed Temperature System (DTS)

2. THE TEORRETICAL OF GROUND PENETRATING RADAR:

Fiber Optics: Fiber Basics

Permeable Pavement Operation & Maintanence Guide

Investigations of a Long-Distance 1000 MW Heat Transport System with APROS Simulation Software

ASPHALT CORE DAMS An embankment dam with asphaltic concrete core is an appropriate dam type for the very highest future dams ICOLD Bulletin 84 (1992)

WHITE PAPER. Technical information. Installation instructions for outdoor electrical installations gesis IP+

Intelligent Solutions DTS Applications LNG Facilities

Specification Guidelines: Allan Block Modular Retaining Wall Systems

PRESENT ISSUES FOR CENTRE DE LA MANCHE DISPOSAL FACILITY

Site Grading and Drainage to Achieve High-Performance Basements

CONSTANT HEAD AND FALLING HEAD PERMEABILITY TEST

AS COMPETITION PAPER 2008

Indiana State Department of Health Construction Guidelines for Gravity and Flood-Dose Trench Onsite Systems

How To Use A Water Source Heat Pump

A guide to preventing structural damage

6.4 Taigas and Tundras

Safe & Sound Bridge Terminology

LNG Monitoring. Fiber-Optic Leakage Detection System. Pipeline leakage detection. Regasification and liquefaction monitoring

A CASE-STUDY OF CUA_DAT CFRD IN VIETNAM

Drayton Digistat +2RF/+3RF

The correct answers are given below. Some talking points have been added for the teachers use.

LIFE SCIENCE. Hoop House Construction for New Mexico: 12-ft. x 40-ft. Hoop House BRINGING TO YOUR HOME ECONOMICS COLLEGE OF AGRICULTURE AND

Failing Culverts Structural Problems & Economic Considerations

Construction sites are dewatered for the following purposes:

Earth Science Landforms, Weathering, and Erosion Reading Comprehension. Landforms, Weathering, and Erosion

PILE FOUNDATIONS FM 5-134

The University of Toledo Soil Mechanics Laboratory

Storm Drain Inlet Protection

Outlet stabilization structure

Text and photos: Juha Siekkinen, Life+ Return of Rural Wetlands Cover drawing: Jari Kostet Maps and aerial photos: National Land Survey of Finland

Experiment (13): Flow channel

Removable Aluminium posts

Chapter D9. Irrigation scheduling

Moving Small Mountains Vesuvius Dam Rehab

This paper describes an instrumentation system concept which should be capable of early detection of a leak-before* break in main steam lines.

The Water Cycle Now You See It, Now You Don t

APPLICATION PROCEDURES FOR PLACEMENT OF UNDERGROUND WATER AND SEWER PIPELINES IN THE VICINITY OF TRANSPORTATION FACILITIES UNDER THE

(1) Discuss the determination of the need for public visitation. Visitor center density within 100 miles.

CABLE ASSET MANAGEMENT PREDICT WITH CERTAINTY. Kuljit Singh BSc Honours MIEE(IET,UK) 5 June 2014

Index. protection. excavated drop inlet protection (Temporary) Block and gravel inlet Protection (Temporary)

Cold Weather Concrete Practices

EXCAVATION AND PILING NEAR SEWERS, STORMWATER DRAINS AND WATER MAINS

CABLE MONITORING SOLUTION

International Greenhouse Company

Guidelines for Durable Driveways, Carports Patios, Walks, Garage Floors

UNDER DRAINAGE AND FILTER DESIGN

6. Base your answer to the following question on the graph below, which shows the average monthly temperature of two cities A and B.

METHOD A10 (a) THE DETERMINATION OF THE IN-PLACE DRY DENSITY OF SOIL OR GRAVEL BY THE SAND REPLACEMENT METHOD

ETL listed for installations within 5 ft. (1.5M) of outer edge of water Rev E Page 1 of 10

3. Contractor shall ensure that all permits are obtained prior to any construction. Contractor shall be responsible for all utility fees.

Septic Tank Use & Maintenance Tips

Homeowner s Guide Foundation Water PenetrationTips TIPS TO IDENTIFY WATER PENETRATION PROBLEMS / CRACKING BASEMENTS

RIEGL VZ-400 NEW. Laser Scanners. Latest News March 2009

AWWA Small Systems Pipe Repair Checklist, as published in July 2008 Opflow Question of the Month

Fibre Bragg Grating Sensors An Introduction to Bragg gratings and interrogation techniques

(

Frost Damage of Roof Tiles in Relatively Warm Areas in Japan

How To Use A Fibre Optic Temperature Sensor

Flash Flood Science. Chapter 2. What Is in This Chapter? Flash Flood Processes

Dimensional and Structural Data for Elliptical Pipes. PD 26 rev D 21/09/05

PERMEABILITY TEST. To determine the coefficient of permeability of a soil using constant head method.

SEPTIC SYSTEM CONSTRUCTION REQUIREMENTS ST. MARY S COUNTY HEALTH DEPARTMENT

ARCHITECTURAL TECHNOLGY 4 ADVANCED CONSTRUCTION TECHNOLOGY BASEMENT CONSTRUCTION YEAR 3 SEMESTER 1 AIDAN WALSH R Lecturer: Jim Cahill

The rock cycle. Introduction. What are rocks?

Sample Punch List. Garth Ruffner Landscape Architect (916) Page 1 of 5

Solar air collectors for industry and larger halls S Ø. Efficient dehumidification and air heating for free...

Transcription:

1 (7) DAM MONITORING USING A FIBRE-OPTIC TEMPERATURE SENSOR Marja Englund, Ari Ipatti, Paavo Patrikainen Fortum Power and Heat Oy PO Box 20, 00048 FORTUM, Finland Tel. +358 10 4511 Antti Leskelä Fortum Engineering Ltd PO Box 10, 00048 FORTUM, Finland Tel.+358 10 45 32339 Henry Ketolampi, Ilkka Kylmänen Kemijoki Oy PO Box 8131, FIN-96101 ROVANIEMI Tel. +358 16 7401 ABSTRACT In this work the suitability of fibre-optic methods in the monitoring of an earth dam was tested. The purpose of the work was to obtain information on the water flow inside a soil structure and to measure the temperature distribution of an old earth dam during thawing using a fibre-optic system based on the Raman backscatter technique. 1 INTRODUCTION During floods, earth dams are under the greatest stress, and their shoulder parts are at their weakest due to rain or frost. Especially in these kinds of extreme weather conditions, the observation of earth dams and spillways should be increased in order to ascertain the safety of the dams. Statutory dam safety monitoring puts pressure on the creation of monitoring systems that require less and less manpower. To this end, fibre-optic measuring systems are potential new methods. The attractiveness of these monitoring methods lies in the advantageous price of optical fibre, the possibility to use the fibre as a measuring sensor of hundreds of metres in length, and the possibility to implement the monitoring automatically either as a continuously operating solution or, e.g., a method that gives an alarm signal.

2 (7) This paper presents experimental results that demonstrate the usability of a distributed fibre-optic temperature measurement system in monitoring an earth dam. Optical fibres were installed in two different test sites. The first one was a soil material test structure where the purpose was to obtain information on the water flow inside the test structure. The second site was an old earth dam where optical cables were installed in order to measure the temperature distribution during thawing. 2 MEASUREMENT METHOD A distributed fibre-optic system consists of an optical fibre for temperature sensing and a measuring unit. A short laser pulse is sent into the sensing fibre. As a result of spontaneous Raman scattering, some anti-stokes and Stokes photons are generated along the fibre. A fraction of these scattered photons is captured in guided modes of the fibre and then propagated back and detected by a fast photodetector. The generation of Stokes photons involves the creation of optical photons, which is slightly temperature sensitive. On the other hand, the generation of anti-stokes photons involves the annihilation of photons. Since photon distribution is temperature dependent, the number of anti-stokes photons is very temperature sensitive. By measuring the signal received at differing times after the pulse is sent and relating this to the speed of light, it is possible to identify which part of the fibre the backscattered light came from (Fig 1). Back-scattering light Optical fibre Light beam Distance x = v * t/2 v = velocity of light in an optical fibre Fig.1 Operation principle of a fibre optic temperature sensor. 3 SOIL TEST AND FIBRE-OPTIC MONITORING When studying the soil material of the earth dam to be built in Northern Finland, it was found out that there was enough moraine material needed for the building of the dam in the vicinity of the construction site. However, finding filter material with properties that meet the standard values, which is important in respect of the functioning of earth dams, has turned out to be a problem. There are gravel and sand formations in the area, but for the majority, their fine aggregate content (d < # 0.06 mm) has been found to be too high in view of the general filter structure criteria. The high fine-aggregate content also means that the water permeability of the materials is insufficient to dry the amount of water that is filtered through the compaction part.

3 (7) A test structure was designed to test the functioning of the soil structures. The tests were performed during unfrozen periods in 1998, 1999 and 2000. A cross-section of the test structure under water pressure can be seen in Fig. 2 a). The objective of the tests carried out in this structure was to determine the actual mutual functioning of local materials and the possible use of various synthetic materials in the filter structures. The suitability of fibre-optic methods in the constant monitoring of an earth dam was tested the first time in 1999. The purpose was to obtain information on the water flow inside the test structure. 3.1 Installation of an optical sensor The water flow inside the soil test structure was indirectly observed by measuring the water-induced temperature distribution of the soil layers with an optical sensor cable. To better illustrate water migration it was decided to heat the water used in the test. An optical cable was installed in four layers in the soil structure that had been compacted in layers. The total length of the sensor cable was over 350 m. In each layer, there were about 10 metres of cable (Fig 2b). The total length of the cable installed in the soil structure was 48 m (269 m to 317 m). The position of the cable was documented at every one-meter distance during installation. 2a) 2b) Optical cable 1. layer Fortroc-geogrid Movable cover costant pressure water inlet 2. layer Gravel Moraine 4. layer Enkadrain-carpet 3. layer 1. layer Pipe to a measuring tank 6000 Optical cable 4. layer Fig. 2 a) A cross-section of the test structures, and b) An optical cable installed in four different layers in the soil structure.

4 (7) 3.2 Measurement results The temperature measurement took place from 16 26 September 1999 and information was collected at 20 minute intervals. The water pressure test started on 20 September 1999. The first detected changes in the temperature took place on 21 September 1999 at about 3:30 a.m. in the range of about 302 and 303 metres. At about 6 p.m. of the same day, temperature changes were also detected at points 282 m and 283 m (Fig 3). Warm water entered the soil first at a point that was at a height of about 1 m (corresponding to the 3 rd installation layer), and viewed from the filter side on the lefthand edge. In the afternoon, the water drained to the front edge of the second layer on the left-hand side (Fig 2 and Fig 3). 16.9.1999 16:21:38 Temperature [ C] 25.9.1999 18.9.1999 8:34:18 20 19.9.1999 4:42:39 20.9.1999 26.9.1999 20:56:40 15 21.9.1999 16:32:38 24.9.1999 22.9.1999 12:38:21 23.9.1999 10 9:44:58 1. 2. 3. 4. 24.9.1999 6:20:09 25.9.1999 5 30cm high 60cm high 120cm high 150cm high 2:56:39 30cm high 150cm high 25.9.1999 23:03:37 26.9.1999 11:38:11 0 265 270 275 280 285 290 295 300 305 310 315 [ 320 m] Fig. 3 The total length of the cable installed in the soil structure was 48 m (from 269 m to 317 m). The first detected changes in the temperature took place on 21 September 1999 at about 3:30 a.m. in the range of 302 and 303 metres.

5 (7) It can be seen in the measurement data that the temperature continues to spread evenly, first through the front edge of the third installation layer to the front edge of the fourth layer (about 1.5 m high) and to the left-hand side of the layer. At about the same time, also the front edge of the second and first layer is warmed up. It is also noteworthy that the fibre hardly warms up in the range 287 297 m, 268 277 m and 310 318 m. This probably means that the water cannot get to the fibre sides of the first, second, and third layers. If the test had continued further, the water would evidently have warmed the filter side of the fourth layer, because the temperature rise in the fibre from 308 m onwards was significant compared with the temperature of the rest of the fibre. 3.3 Conclusions on the soil test The temperature distribution obtained from the optical fibre showed that in the soil test structure there was an area near the edges that permeates water significantly better than the rest of the area, although efforts have been made to make it smaller with surface roughing. The greater permeability is caused, in addition to the interface, because the waterproofing in the edge area cannot be as efficient as elsewhere. It can be estimated that about 80% of the water that penetrated the test structure comes from both edge zones (1/3 of the chute width). The greater water permeability of the edge zones can be detected in some measurements carried out on the surface of the test structure during the tests. However, there are some fluctuations in the measurements, and in some tests it seems that only the other edge was clearly more permeable in the middle section. 4 MONITORING OF OLD DAM WITH FIBRE-OPTIC SENSOR Optical cables were installed in an old earth dam situated in the Northern Finland in order to measure the temperature distribution of the dam structure during thawing. Another purpose of the measurement was to ascertain the changes in the water flow inside the dam structure at different times of year. In the autumn, six almost 20-m-deep holes with a diameter of about 20 cm were drilled into the earth dam structure of the hydro power plant directly from the surface of the earth dam all the way down to the bedrock. Three holes were drilled on the poolside edge of the road on top of the dam and three on the sluice river edge symmetrically, see Figure 4.

6 (7) Six 16 m - 20 m deep holes high +248 0 Fibre Optic Cable 1-18.40 Fig. 4 An optical cable was installed in each of the six holes. The holes were filled alternately to make water permeable and impermeable layers. The total length of each cable installed into the holes was about 20 m. The cable used was NK Cables underground cable, which, due to its strong cable clamp, was estimated to withstand the strain required by the installation work, water and frost. Shrink stoppers were installed in the cut end of the cable to protect the fibres. The cables were installed into the holes, and the holes were filled alternately to make water permeable and impermeable layers. The cables were led to the nearest cable chute leading to the dam gate control house next to the road on top of the dam. 4.1 Temperature measurements When the cables had been led to the terminal boxes, an installation inspection and temperature signal positioning measurement were carried out. The purpose was to measure the fibres in the cable using the so-called "cut-off fibre measurement" principle, because the cables ended on the bottom of the drill-holes. The equipment usually carries out the measurement as a loop, so by combining the cables suitably, it is possible to measure all the cables simultaneously. The cables that were installed symmetrically on the opposite sides of the road were chosen as the measurement pairs (measurement loop). Cables 1 and 4 were in the drill-holes at a distance of about 2.5 m from the concrete wall. Cables 2 and 5 were at a distance of 2.5 m from cables 1 and 4, and cables 3 and 6 were at a distance of about 10 m from cables 1 and 4.

7 (7) The measurements were continued during the winter and spring. The first measurement was taken at the end of 1999. After that, there was one more wintertime measurement and a continuous measurement that was carried out in the spring (April- June) at the time the snow was melting (Fig 5). 15 Temperature [ C] ground ground 10 9.9.1999 5 4.7.2000 Cable1 Cable 4 27.1.2000 0 84 89 94 99 104 109 114 119 2.3.2000 [ m ] -5 5.4.2000 bottom -10 Fig. 5 The temperature distribution of the earth dam (cables 1 and 4) 9 September 1999, 27 January, 2 March, 6 April and 4 July 2000. Cables 1 and 4 were symmetrically installed on the opposite sides of the road and were chosen as the measurement pairs (measurement loop). The total length of each cable installed in the holes was about 20 m. 5 CONCLUSIONS The results obtained in this work indicated that fibre-optic temperature measurement is suitable for testing the functioning of earth dam structures and the long-term monitoring of a dam. This method is particularly suitable for northern dams, as in the north the varying seasons result in extensive temperature differences between soil structures and water. The temperature measurements made it possible to monitor water flow inside the soil structures and the thawing of ground frost. The temperature measurements taken in the first year in the old earth dam do not confirm or eliminate the possible risk of dam core erosion due to freezing and thawing near the concrete structure (the winter was not particularly severe), but they indicate that the rock foundation downstream can be frozen at least below the downstream shoulder. However, it seems more probable that the springtime groundwater well fluctuations are due to periodical changes in fissure permeability, rather than due to moraine erosion in the concrete contact.