Rad-60. Users Guide. LAURUS Systems, Inc. - Ph: Fax:

Similar documents
DOSISYS DMC Dosimeters S, X, XB. User's Manual

User's Guide. Dosimeter Configuration Software ADR-1/60

RDS-31 S/R Multi-purpose Survey Meter User s Manual

User's Guide. Pinless Moisture Meter. Model MO257

MICROPROCESSOR HOME - SECURITY SYSTEM Home4

Atomic Alarm Clock Instruction Manual

SpO2 PULSE OXYMETER MD-300

Model: Manual DC: WIRELESS COLOR FORECAST STATION

MEMO ALARM CLOCK Operating Manual

User's Manual. Heavy Duty Dissolved Oxygen Meter Model

ATS-505. GB Version 1

INSTALLING A/C ADAPTER

Application Note. ipix A Gamma imager to support various applications

Drayton Digistat +2RF/+3RF

EzFlex Combustible Gas Leak Detector Model EZ40

Microwave Meter. Instruction Manual

1. SAFETY INFORMATION

Dual Laser InfraRed (IR) Thermometer

Dual Laser InfraRed (IR) Thermometer with Color Alert

Thermistor Thermometer MODEL NO

Automatic Phone-Out Home Monitoring Systems

Pocket Tach 99 (PT99) Non-Contact Tachometer

Temperature Humidity Meter

ER-1 Emergency Response System INSTALLATION & PROGRAMMING GUIDE

DUAL SENSING DIGITAL THERMOSTAT PRODUCT INSTRUCTIONS. Construction Automotive Industry

User s manual FLIR VP50/VP52 Non-contact AC voltage detector

RADIO CONTROLLED DIGITAL CLOCK MODELS / 88906

Light Meter (Foot Candles)

CQ-Series. User Manual. American Weigh Scales, Inc. CQ-350 (350x0.1g) CQ-500 (500x0.1g) Digital Pocket Scale . = + CALC AC CE % TARE OFF ON MC MR CALI

Control Location. Replacing Battery

notes MERRTT IS-302 Radiological Survey Instruments and Dosimetry Devices

IN-OUT Thermometer with Cable Free Sensor and Clock

User's Guide. Integrating Sound Level Datalogger. Model Introduction

microlife PF 100 Electronic Asthma Monitor Instruction Manual (1-15) Moniteur d'asthme électronique Mode d'emploi (16-31) Monitor electrónico para el

Mold Alert... Operation Manual P0270

SINGLE-CHANNEL GAS-DETECTOR GAS ALARM DG510/1P

Radio-Controlled Projection Clock with Indoor Temperature

Radiation Detector with USB port. Measures Radioactivity Easily and Reliably. gamma-scout.com

User Guide. Temperature and Humidity Datalogger. Model 42280

Programmable Room Thermostat 7 Day (5-2 Day) Models: / Power Supply: Battery / Mains

EK908FHL - Thermostat for floor heating

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

WEATHER STATION Instruction Manual Cat. No IT

G64 Area Gamma Monitor

Dual Laser InfraRed (IR) Thermometer

RS Stock No Instruction Manual RS-1340 Hot Wire Anemometer

REMOTE TERMOMETER TE 219 LED USER MANUAL

Atomic Projection Alarm with Indoor and Outdoor Temperature

User Guide. Heavy Duty Dissolved Oxygen Meter. Model

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Dual Laser InfraRed (IR) Thermometer

600-GD & 600-GDL 600 SERIES GAS DETECTOR

Milwaukee USER MANUAL

EL-USB-2-LCD FEATURES WINDOWS CONTROL SOFTWARE DISPLAY FUNCTIONS. Page 1 of 5

RF Projection Barometer With Remote Thermo Sensor

Model: v2 Quick Setup Guide DC: Atomic Projection Alarm with Indoor and Outdoor Temperature

User's Guide. Digital Psychrometer. Model RH390. F C WBT Dew Point MAX MIN

Use of the VALIDATOR Dosimetry System for Quality Assurance and Quality Control of Blood Irradiators

User Manual. Humidity-Temperature Chart Recorder. Model RH520

RomiApex A-15. APEX LOCATOR User Manual

LD2 One & Two Zone Water Detection Alarm Installation and Operation Manual

IPS Magneto-Thermal protection device for electric loads.

Lockout Specification BW Clip Maintenance-free single gas detector

INSTRUCTIONS FOR VOICE CONTROLLED TALKING ALARM CLOCK

User's Guide. Digital Sound Level Meter. Model

4-Channel Thermometer / Datalogger

TMS TANK MANAGEMENT SYSTEM

Laser Distance Meter Laser-Distanzmesser Laser distance-mètre Metro di distanza laser Medidor Láser de Distancia User Manual

Quick start: Panic Watch EU

Automatic Wrist Blood Pressure Monitor with

Ultrasound Technologies. PD1v. vascular pocket doppler. Operating Instructions

Talking Atomic Alarm Clock Instructions

ODYSSEY. Security System Owner s Manual. Kit No. 08E51-SHJ E55-SHJ American Honda Motor Co., Inc. - All Rights Reserved.

Operating Manual Remote Cost Control Monitor

PR-2500 Portable Receiver. Owner s Manual

VOLTAGE/CURRENT CALIBRATOR ISO-TECH ILC-421

Reizen Atomic Talking Analog Alarm Clock Item # Instruction Manual

CAD-05 Kit GSM Auto Dialer. Owner s Manual

Car Alarm Series 2 B 2 Buttons

WIRELESS HOME ALARM SYSTEM (WHA1)

How To Use A Meter

BEP FD-2 CONTOUR MATRIX FUME DETECTOR

The Weather Station. Hanging Hole. LCD Display Battery Cover. Function Keys. Detachable Stand

User's Guide Integrating Sound Level Datalogger Model

MAKING MODERN LIVING POSSIBLE. living connect. Installation and User Guide. Danfoss heating

Milwaukee USER MANUAL. Milwaukee. Smart DO Meter PORTABLE DISSOLVED OXYGEN METER MODEL: SM600. Authorized Dealer: ISMIL600 11/01

Back-UPS Pro 1300/1500 Installation and Operation

INSTRUCTION MANUAL DTH Fax: (503)

AD-01 Slave Auto Dialer. Owner s Manual

e I N S T RUC TION M ANU A L

Vibrating Alarm Clock. Model VA-3

WIRELESS SENSOR BATTERY REPLACEMENT INSTRUCTIONS For Safewatch Residential Control Panels

323/324/325. Calibration Manual. Clamp Meter

9452/9453 Installation and User Guide

evohome Wireless Radiator Zoning Kit Installation & User Guide

Automatic Telephone Dialer TD-101(W)

User s Manual AURORA 1.2K/2.2K

Optical Power Meter. Specification & User Manual

INSTRUCTION MANUAL. NC-500 NETcat Pro Wiring Tester

How To Program An Autodialer

Transcription:

Rad-60 Users Guide LAURUS Systems, Inc. - Ph: 410-465-5558 - Fax: 410-465-5257 - www.laurussystems.com

2 RAD-60 DOSIMETER USER S GUIDE The RAD-60 is a Digital Pocket Alarm Stand Alone Dosimeter designed for use by people who may be exposed to gamma and X-ray radiation during their work. It provides programmable dose rate and dose alarms. RAD-60 is microprocessor controlled and is operated using the display and the push button. The push button gives a bleep each time it is pressed. To complete an action, release button or press again (bleep) and hold down until a second bleep is heard. The three digit display shows dose, dose rate and various messages. The display and sound signal are used to indicate alarms (dose, dose rate, low battery, defect, dose/dose rate overflow). The RAD-60 is ready for use after the battery has been installed. It must be worn in the chest area such as a chest pocket (pocket clip on the outside) with no metal objects in the same pocket. RAD-60 Top view Switch on Press push button until all segments are displayed. -The dose/dose rate is displayed within 5 seconds. Change display (dose/dose rate) Press push button once. -Display changes to dose/dose rate for 10 seconds. Change display mode permanently (dose/dose rate) Press push button once. -Display changes to dose/dose rate. -The display mode is now changed. 1

Switch off (OFF) 3 -Display changes to OFF. -The display goes blank. Chirp on/off (CHr) -Display changes to CHr. -The chirp is activated/deactivated. -The mark is displayed when the chirp is active. Reset cumulative dose (CLr) -Display changes to CLr. -Display blinks cumulative dose. -The cumulative dose is now reset. Show dose alarm level (dal) -Display changes to dal. -Current alarm level is displayed. Wait for return to dose/dose rate display. Change dose alarm level (dal) There are 6 different levels for dose alarm: 10 µsv, 100 µsv, 1 msv, 10 msv, 100 msv, 1 Sv or 1 mr, 10 mr, 100 mr, 1 R, 10 R, 100 R and 0. User can select any of these for alarm level. If 0 is selected then alarm is deactivated. -Display changes to dal. -Current dose alarm level is blinking. -Select alarm level by short pushes. -Confirm the selected level with long push until a long bleep occurs. 2

Show dose rate alarm level (dra) 4 -Display changes to dra. -Current alarm level is displayed. Wait for return to dose/dose rate display. Change dose rate alarm level (dra) There are 6 different levels for dose rate alarm: 10 µsv/h, 100 µsv/h, 1 msv/h, 10 msv/h, 100 msv/h, 1 Sv/h or 1 mr/h, 10 mr/h, 100 mr/h, 1 R/h, 10 R/h, 100 R/h and 0. User can select any of these for alarm level. If 0 is selected then alarm is deactivated. -Display changes to dra. -Current dose rate alarm level blinks. -Select alarm level by short pushes. -Confirm the selected level with long push until a long bleep occurs. Battery and display test (dia) -Display changes to dia. -The alarm sounds for 5 seconds. -If the battery symbol occurs on the display after the test, then the battery is weak and shall be replaced. Low battery, normal operation The battery symbol is blinking all the time and the audible alarm is a long bleep once an hour. The dose measurement is continued. Note! Push button functions are disabled during low battery. Low battery when switched on (Lob) The display shows Lob and the battery symbol is blinking. Audible alarm is short bleep once a second. The dose measurement is prevented. 3

Dose alarm or Dose rate alarm (Blinking display) 5 The dose/dose rate display is blinking and the continuos audible alarm is on. The dose alarm can be reset by pressing the push button. The display changes to previously selected mode. Audible alarms Dose rate: - - - - (4 bleeps each second) Dose: (1 bleep in two seconds) Simultaneous Dose and Dose rate alarm The dose rate display is blinking and the continuous audible alarm is on. The dose rate alarm is dominating. Reset the alarm by pressing the push button. The display changes to previously selected mode. Dose overflow alarm (doo) Dose rate overflow alarm (dro) When measurement limits are exceeded, display shows: doo dose overflow alarm dro dose rate overflow alarm Audible alarms Dose rate OFL:........ (8 bleeps each second) Dose OFL: (2 bleeps each second) Overflow alarms cannot be reset. Error (DEF/Er) The display blinks between text DEF and Er+number. The continuous audible alarm is on. The dose measurement is prevented. If there is only blinking Er+number text on the display, the dose measurement may be continued. Only visual alarm is given, no audible alarm. Error codes and types Er1 = Calibration Er3 = Detector Er2 = NVRAM Er4=RAM memory If error should occur write down the Error number (Er+number) and return the dosimeter for servicing. 4

Maintenance and Decontamination 6 No specific maintenance is required except for periodic check of calibration. Cleaning and decontamination may be done with decontamination solutions suitable for use with ABS polymer and polycarbonate materials. Replacement of the alkaline battery Open the battery compartment cover with a coin or small screwdriver. Remove the old battery and replace with new one. The + pole goes in first. Use only AAA alkaline battery (IEC LR03). Close the cover. After battery replacement the dosimeter automatically turns on. Note! After fitting a fresh battery it is recommended to perform the functional test (dia). If the battery symbol appears on the display after the test, refit the battery. Specifications Specifications Radiation detected: Gamma and X-rays Measurement range: dose 1 µsv - 9.99 Sv 0.1 mrem - 999 rem dose rate 5 µsv/h - 3 Sv/h 0.5 mrem/h - 300 rem/h Measurement accuracy: better than ±5% (Cs-137, 662 kev) Energy response: 60 kev - 3 MeV, better than ±25% Dose rate linearity: better than ±15% Operational temperature range: -20 C to +50 C Operational humidity: 10-90% RH Dimensions: 78 * 67 * 22 mm, excluding pocket clip. Weight: 80g, including battery For questions on sales service repair calibra Contact: LAURUS Systems, Inc Attn: Laura Lynch 8779 Autumn Hill Drive Ellicott City, MD 21043 Ph: 410-465-5558 FX: 410-465-5257 Email: LauraLynch@Lauru URL: http://www.laurussy LAURUS Systems, Inc. - 3505 Ellicott Mills Dr, B-1, - Ellicott City, MD - 21043 - Ph: 410-465-5558 - Fax: 410-465-5257 - www.laurussystems.com LAURUS Systems, Inc. - Ph: 410-465-5558 - Fax: 410-465-5257 - www.laurussystems.com 5