CFX96 Real-Time PCR Detection System

Similar documents
CFX96 Real-Time PCR Detection System. Real-Time PCR: CFX96 System

amplification tech Optical Design of CFX96 Real-Time PCR Detection System Eliminates the Requirement of a Passive Reference Dye

Amplification: Thermal Cyclers. Bio-Rad Thermal Cyclers

MystiCq microrna cdna Synthesis Mix Catalog Number MIRRT Storage Temperature 20 C

Fast PCR: General Considerations for Minimizing Run Times and Maximizing Throughput

Essentials of Real Time PCR. About Sequence Detection Chemistries

Image Lab Software for the GS-900 Densitometer

Installation Qualification/Operational Qualification Protocols and Instructions. Experion Automated Electrophoresis Station and Software

How To Install A Gel Doc Xr+ Camera On A Computer Or Mouse Or Tv (For A Powerbook) With A Zoom Lens (For An Ipa) With An Iphone Or Ipa (For Mac) With The Zoom Lens

QIAsymphony RGQ Protocol Sheet

Real-Time PCR Vs. Traditional PCR

Quantitative PCR Systems

Image Lab Software How to Obtain Stain-Free Gel and Blot Images. Instructions

Quantifiler Human DNA Quantification Kit Quantifiler Y Human Male DNA Quantification Kit

Introduction To Real Time Quantitative PCR (qpcr)

TaqMan Fast Advanced Master Mix. Protocol

Highly specific and sensitive quantitation

SYBR Green Realtime PCR Master Mix -Plus-

Computer Specifications

Protocol. Introduction to TaqMan and SYBR Green Chemistries for Real-Time PCR

ab Hi-Fi cdna Synthesis Kit

Real-time quantitative RT -PCR (Taqman)

PicoMaxx High Fidelity PCR System

RT-PCR: Two-Step Protocol

Stratagene QPCR Mouse Reference Total RNA

LightCycler 480 Real-Time PCR System

Validating Microarray Data Using RT 2 Real-Time PCR Products

ProteinChip Energy Absorbing Molecules (EAM)

Factors Influencing Multiplex Real-Time PCR

Speed Matters - Fast ways from template to result

Absolute Quantification Getting Started Guide

The GeneAmp PCR System Results you can trust. A PCR platform you can grow with. GeneAmp. PCR System 9700

Transforming a ChromLab Software 2-D Purification Template into an Automated Multidimensional (Multi-D) Purification Workflow An Instructional Guide

Cell Sorting. S3e Cell Sorter Quick Guide

quantitative real-time PCR, grain, simplex DNA extraction: PGS0426 RT-PCR: PGS0494 & PGS0476

SYBR Green PCR Master Mix and SYBR Green RT-PCR Reagents Kit

RNA Extraction and Quantification, Reverse Transcription, and Real-time PCR (q-pcr)

Path-ID Multiplex One-Step RT-PCR Kit

Mir-X mirna First-Strand Synthesis and SYBR qrt-pcr

Power SYBR Green PCR Master Mix and Power SYBR Green RT-PCR Reagents Kit

REAL TIME PCR USING SYBR GREEN

Mir-X mirna First-Strand Synthesis Kit User Manual

Data Analysis on the ABI PRISM 7700 Sequence Detection System: Setting Baselines and Thresholds. Overview. Data Analysis Tutorial

Thermo Scientific DyNAmo cdna Synthesis Kit for qrt-pcr Technical Manual

Eco TM 48 Real Time PCR System. Fastest block-based qpcr. Four colour multiplexing. Supports all chemistries. Fast cycling protocols

Bio-Rad Laboratories. QC data management solutions. Introduce Your Laboratory to a Whole New World of Unity Data Management Solutions

Real-time PCR: Understanding C t

Plexor Systems Instrument Setup and Data Analysis for the Applied Biosystems 7300 and 7500 Real-Time PCR Systems

Plexor Systems Instrument Setup and Data Analysis for the Roche LightCycler 2.0 and LightCycler 1.5 Systems using LightCycler Software Version 4.

Foreign Taxes Paid and Foreign Source Income INTECH Global Income Managed Volatility Fund

Technical Note. Roche Applied Science. No. LC 19/2004. Color Compensation

Application Note. Single Cell PCR Preparation

TITRATION OF raav (VG) USING QUANTITATIVE REAL TIME PCR

Expression Proteomics // Tools for Protein Separation and Analysis. 2-D Electrophoresis. Tools for Rapid, High-Resolution Protein Separations

Absolute Quantitation Using Standard Curve Getting Started Guide

2.500 Threshold e Threshold. Exponential phase. Cycle Number

User Bulletin #2 ABI PRISM 7700 Sequence Detection System

Reconstituting and Diluting Primers and TaqMan Probes

Gene Expression Assays

DyNAmo cdna Synthesis Kit for qrt-pcr

Quantitative Real Time PCR Protocol. Stack Lab

PrimeSTAR HS DNA Polymerase

360 Master Mix. , and a supplementary 360 GC Enhancer.

Supplemental Material. Methods

BacReady TM Multiplex PCR System

C1000 Touch Thermal Cycler Instruction Manual

Technical Note. Roche Applied Science. No. LC 18/2004. Assay Formats for Use in Real-Time PCR

Table of Contents. I. Description II. Kit Components III. Storage IV. 1st Strand cdna Synthesis Reaction... 3

Real time and Quantitative (RTAQ) PCR. so I have an outlier and I want to see if it really is changed

HiPer RT-PCR Teaching Kit

QPCR Applications using Stratagene s Mx Real-Time PCR Platform

Configuring DHCP for ShoreTel IP Phones

Fluorescent dyes for use with the

QuantiFast Multiplex PCR Handbook

Reverse Transcription System

Application Note. Biotechnology Explorer Crime Scene Investigator PCR Basics. Kit: A Real-Time PCR Extension

RevertAid Premium First Strand cdna Synthesis Kit

NI USB-6008/6009 OEM USER GUIDE

Real-Time Quantitative PCR Instruments and Consumables

Absolute Quantifi cation of Gene Expression using SYBR Green in the Eco Real-Time PCR System

User Manual/Hand book. qpcr mirna Arrays ABM catalog # MA003 (human) and MA004 (mouse)

DNA Integrity Number (DIN) For the Assessment of Genomic DNA Samples in Real-Time Quantitative PCR (qpcr) Experiments

Quando si parla di PCR quantitativa si intende:

RT rxns. RT rxns TRANSCRIPTME Enzyme Mix (1) 40 µl 2 x 50 µl 5 x 40 µl

MANUFACTURING DATA MANAGEMENT FOR MASTERCAM

PCR Instruments and Consumables

StepOne and StepOnePlus Real-Time PCR Systems

MiniOpticon System. Instruction Manual. For MiniOpticon real-time PCR detection system with CFX Manager software.

Brilliant III Ultra-Fast SYBR Green QRT-PCR Master Mix

Relative Quantification Applied Biosystems 7300/7500 Real Time PCR System

Applied Biosystems 7500/7500 Fast Real-Time PCR Systems. SUBJECT: Memory Upgrade Requirements for 7500 Software v2.0

Quantum View Manage Administration Guide

Guide to using the Bio Rad CFX96 Real Time PCR Machine

PowerPac Universal and PowerPac HV Power Supply Data Transfer Software. Instruction Manual

1.5 GHz Active Probe TAP1500 Datasheet

MERCER S COMPENSATION ANALYSIS AND REVIEW SYSTEM AN ONLINE TOOL DESIGNED TO TAKE THE WORK OUT OF YOUR COMPENSATION REVIEW PROCESS

High-Speed Inter Connect (HSIC) Solution

Global Economic Briefing: Global Inflation

User Manual. CelluLyser Lysis and cdna Synthesis Kit. Version 1.4 Oct 2012 From cells to cdna in one tube

[ Care and Use Manual ]

Transcription:

Real-Time PCR: CFX96 System CFX96 Real-Time PCR Detection System Designed for the Way You Work

The CFX96 System Designed for the Way You Work Bio-Rad s 00-series PCR instruments meet all your PCR needs whether you are designing your first experiment or running a high-throughput laboratory and analyzing large gene expression studies. The CFX96 real-time PCR detection system builds on the power and flexibility of the C00 thermal cycler, adding an easy-to-install interchangeable reaction module to create an exceptional real-time PCR system. The system s unsurpassed thermal performance plus its innovative optical design produce accurate, reliable data, and the powerful yet intuitive software accelerates every step of your real-time PCR research, shortening the time between getting started and getting great results. With the CFX96 system, you can: n Get great results right away quick installation and factory-calibrated optics let you set up the system in seconds n Fit experiments into your schedule fast thermal cycling produces results in <30 minutes n Save research time thermal gradient feature lets you optimize reactions in a single experiment n Minimize sample and reagent usage reliable results obtained with sample volumes as low as µl n Rely on performance innovative technologies with long-lasting LEDs and solid-state components provide maximal reliability and optimal quantitative results n Analyze results when and where you want software can send e-mail notification with attached data file when the run is finished n Easily expand your throughput when you need to up to 4 instruments can be controlled by a single computer

Genomic Research Solutions From Bio-Rad Bio-Rad s PCR instruments, reagents, and plastics are powerful building blocks for your genomic research, providing the flexibility and reliability you need to accelerate discovery. Reagents That Provide Optimal Performance Bio-Rad reagents demonstrate best-of-class performance over a wide dynamic range of input RNA, cdna, and genomic DNA. iscript cdna synthesis kits and iscript one-step RT-PCR kits minimize the potential for primer-dimer formation and other nonspecific PCR artifacts, delivering maximum sensitivity and consistent results every time. iq multiplex powermix makes multiplex real-time PCR easier by minimizing the need to optimize buffer, enzyme, or primer concentrations. Don t Worry About Your Consumables Bio-Rad s full line of plastic consumables has been validated to deliver reliable, reproducible results, leaving you one less thing to worry about. Each box of Bio-Rad tubes, plates, and caps is process-sampled and tested to be negative for DNase, RNase, and DNA. Successful Gene Expression Striving to make genomic technologies accessible to every researcher, Bio-Rad offers a complete line of products to ensure successful target quantitation, whether you are determining the number of microbes in a given amount of soil or measuring the fold change of an sirna target in response to knockdown using RNAi. Identify the role of target genes in specific cellular processes or signaling pathways using a combination of genomic and proteomic analysis tools from Bio-Rad. 0 30 40 Normalized fold expression 1 0-1 -2 IL1-b Target Tubulin 0 Hr 1 Hr 2 Hr Accurate five-target multiplex gene expression. Human spleen RNA was transcribed into cdna using the iscript cdna synthesis kit. 50 ng cdna was amplified in four replicate 50 μl reactions using five reporter dyes to monitor fluorescence data from five targets. n, FAM/actin (18.02 ± 0.02); n, Cy5/tubulin (20.07 ± 0.03); n, HEX/GAPDH (22.81 ± 0.02); n, Quasar 705/IL1-b (26.39 ± 0.04); n, Texas Red/IL2 (29.17 ± 0.07). Average values are shown in parentheses., relative fluorescence units. Decrease in IL1-b expression and increase in tubulin expression over experiment time-course. The built-in gene expression analysis module in CFX Manager software lets you immediately turn your results into answers, without data export.

Fast Thermal Cycling Superior Uniformity The rate and efficiency of PCR depend critically on the precision of the temperature steps. To obtain reliable, consistent results, all sample wells must maintain proper temperature throughout each incubation step. The CFX96 system uses six independently controlled thermal electric modules (TEs), the heating and cooling elements of the thermal cycler, to maintain tight temperature uniformity at all points during the run even while ramping. Rapid Arrival at Target Temperature A key component of overall protocol run time is the time to reach target temperature, which is determined by the average ramp rate and the time for the sample block to reach thermal uniformity. Maximum ramp rate is less important, because it can fluctuate significantly during the ramp. The CFX96 system s temperature control produces high average ramp rates and tight uniformity during ramping, to yield fast time to target temperature and faster protocol run times. Run times can be dramatically shortened to less than 30 minutes while still producing accurate quantitative results. Now you can tailor your runs around your schedule, instead of tailoring your schedule around your runs. 90 85 Temperature, C 80 75 70 65 60 The patent-pending reduced-mass sample block heats and cools more quickly than standard blocks, so average ramp rates are increased and overall run times are reduced. 55 0 20 40 60 80 0 120 140 160 180 200 Time, sec Rapid arrival at target temperature and superior uniformity. 00-series thermal cyclers exhibit high average ramp rates, rapid settling time, and tight thermal uniformity throughout the ramp. This graph shows the temperature measured by probes in 15 wells across a sample block. The traces are nearly indistinguishable due to the tight uniformity. Note the consistent ramp rate throughout heating and cooling. 16 18 20 22 24 26 28 30 0 0 30 40 Precise target discrimination. One-cycle spacing Excellent uniformity. IL1-b plasmid template between threshold cycle ( ) values is precisely maintained diluted to 5 copies/reaction amplified in the in a series of 2-fold dilutions of human genomic DNA presence of a FAM-labeled detection probe with from 120 to 15 ng. IL1-b target was amplified using a FAMlabeled iq supermix. Graph shows 96 replicates of μl detection probe with iq supermix. Graph shows reactions. Average = 19.81 ± 0.. 8 replicates for each dilution with the following average values: 22.15 ± 0.02, 23.14 ± 0.04, 24.28 ± 0.03, 25.41 ± 0.04., relative fluorescence units. 0 5 15 20 25 30 High speed performance. Precise spacing between values is maintained for a -fold serial dilution of tubulin plasmid target amplified using iq SYBR Green supermix. Data was acquired using the CFX96 system s fast scan mode in a two-step protocol that took less than 25 min for the amplification. Graph shows 4 replicates for each dilution.

Innovative Optical Design The CFX96 system s solid-state optical technology (six filtered LEDs and six filtered photodiodes) provides sensitive detection for precise quantitation and target discrimination. Scanning just above the sample plate, the CFX96 optics shuttle individually illuminates and detects fluorescence from each well with high sensitivity and no cross talk. The optical system automatically collects data from all wells during data acquisition, so you can enter or edit well information on your own schedule. True Five-Target Multiplexing The CFX96 system can discriminate up to five targets in a single reaction well. The optical filter sets are designed to maximize fluorescence detection for specific dyes in specific channels. At every position and with every scan, the CFX96 optics shuttle is reproducibly centered above each well, so the light path is always optimal and there is no need to sacrifice data collection in one of the channels to normalize to a passive reference. Fast Scan Option You can complete SYBR Green I and single-color FAM protocols even faster using the fast scan mode, which reads single-channel fluorescence from all 96 wells in just 3 seconds. Fluorescence Resonance Energy Transfer (FRET) The CFX96 system s optics shuttle includes one channel with an LED-filter photodiode combination dedicated for FRET singleplex experiments, further expanding your experimental options. As the CFX96 optics shuttle travels across the plate, light is focused directly into the center of each sample well. A C B 0 0 30 40 0 0 30 40 D 0 0 30 40 0 0 30 40 E F 0 0 30 40 35 30 25 20 15 2 3 4 5 6 7 8 log starting quantity Six-channel optics shuttle of the CFX96 system. Linearity of five-target multiplex detection. A E, fluorescence data from a series of -fold dilutions of plasmid DNA ( 8 copies) amplified using reporter dyes to monitor five targets. n, FAM/actin; n, HEX/GAPDH; n, Texas Red/cyclophilin; n, Cy5/tubulin; n, Quasar 705/IL1-b; F, standard curves generated from data in A-E, reaction efficiencies range from 97% to 3%., threshold cycle., relative fluorescence units.

Powerful Software CFX Manager software is powerful software for a powerful instrument. It accommodates user needs and different types of experiments with intuitive navigation and customizable settings, including unique log-in names, gene and sample name libraries, and data analysis preferences. Getting Started CFX Manager software s convenient wizards and intuitive navigation make it easy to get started and to get great real-time PCR results. You can use the express-loading feature to instantly access your experiment files and files that are preloaded in the software. To further speed up your process, get the experiment started with the Quick Plate feature, and then enter or edit well information on your own schedule before, during, or after the run has finished. Getting Answers CFX Manager software can send e-mail notification with an attached data file when the run is finished, so you can analyze your results when and where you want. The software has built-in data analysis modules with automatic baseline subtraction and threshold setting. You can easily customize how your data are analyzed and displayed, and you can use 1-step export from any graph or table to export results or images to Excel spreadsheets or PowerPoint presentations. A well-grouping feature is available to analyze multiple experiments from a single plate. CFX Manager software lets you take your results a step further without having to export data and set up your own analysis macro. Perform gene expression analysis by relative quantity ( ) or normalized expression ( ) using multiple reference genes and individual reaction efficiencies. If you are performing a comprehensive study with multiple experiments, you can use CFX Manager software to combine and analyze all data at once. CFX Manager software main application window launched with the Startup Wizard and one attached instrument. CFX Manager software data analysis module, showing well C6 highlighted.

Efficient Optimization Thermal Gradient Determining the optimal temperature for primer annealing is crucial for efficient and specific amplification of product. With the CFX96 system s thermal gradient feature, you can determine the optimal temperature for primer annealing in a single experiment, minimizing the use of precious samples and reagents and saving valuable research time. At any step in a protocol, you can program a temperature gradient of up to 24 C across the reaction block. The thermal cycler provides exceptional temperature uniformity and reproducibility within each gradient zone, and the temperatures can easily be programmed and viewed onscreen in the software, so you can quickly identify the optimal incubation temperature. 67 C 62 C 0 0 30 40 0 0 30 40 40 SYBR Green: E = 68.3% 35 30 25 20 1 2 3 4 5 6 30 SYBR Green: E = 98.7% 25 20 15 1 2 3 4 5 6 56 C SYBR Green: E = 93.6% 15 0 0 30 40 1 2 3 4 5 6 log starting quantity 30 25 20 Thermal gradient experiment for optimizing annealing temperature. A -fold dilution series ( 6 to copies) of plasmid containing GAPDH template was amplified in the presence of SYBR Green dye using a protocol with an annealing thermal gradient ranging from 55 to 68 C. Results are presented for three temperatures, showing 62 C as the optimal in this case, with early threshold cycle ( ) values and the highest standard curve efficiency., relative fluorescence units. A System That Grows With Your Research The flexibility of the 00-series platform allows your setup to grow and evolve as your needs change. Adding more instruments to increase throughput or expand options is as easy as connecting a USB cable. CFX Manager software can independently run four instruments, including a combination of CFX96 real-time instruments and C00 or S00 thermal cyclers. You may start a run on one instrument while another is running a different experiment, or you can start the same experiment on all four instruments at once. PC CFX96 CFX96 CFX96 CFX96

Specifications Thermal Cycler Chassis C00 Maximum ramp rate 5 C/sec Average ramp rate 3.3 C/sec Heating and cooling method Peltier Lid Heats up to 5 C Temperature Range 0 0 C Accuracy ±0.2 C of programmed target at 90 C Uniformity ±0.4 C within sec of arrival at 90 C Gradient Operational range 30 0 C Programmable span 1 24 C Optical Detection Excitation 6 filtered LEDs Detection 6 filtered photodiodes Range of excitation/emission 450 730 nm wavelengths Sensitivity Detects one copy of target sequence in human genomic DNA Dynamic range orders of magnitude Scan time All channels 12 sec FAM/SYBR Green only 3 sec Software Operating systems Multiplex analysis Data analysis modes Windows XP, Windows Vista Up to 5 targets per well PCR quantitation with standard-curve and melt-curve analysis Gene expression analysis by or with multiple reference genes and individual reaction efficiencies Multiple file gene expression analysis Allelic discrimination Endpoint analysis Data export Save, copy, and print all graphs and spreadsheets from right-click menu Export results to Microsoft Excel Copy and paste directly into Microsoft Excel, Word, or PowerPoint files Customizable reports containing run settings, data graphs, and spreadsheets can be directly printed or saved as PDFs System Licensed for real-time PCR Yes Sample capacity 96 wells Sample size 1 50 µl (recommend 25 µl) Communications USB 2.0 Electrical approvals IEC, CE Dimensions (W x D x H) 13 x 18 x 14" (33 x 46 x 36 cm) Weight 21 kg (47 lb) Ordering Information Catalog # Description 184-00 C00 Thermal Cycler Chassis, includes USB flash drive, power cord, instructions; does not include reaction module 184-5096 CFX96 Optical Reaction Module, includes CFX96 optics shuttle, CFX Manager software, communication cable, reagent and consumable samples, instructions 185-5096 CFX96 Real-Time PCR Detection System, includes C00 thermal cycler chassis, CFX96 optical reaction module, CFX Manager software, communication cable, power cord, reagent and consumable samples, instructions 184-5000 CFX Manager Software, includes installation CD, instructions 184-5001 CFX Manager Software, Security Edition, includes 1 user license, installation CD, HASP HL key, instructions 184-50 CFX Manager Software, Security Edition, includes user licences, installation CDs, HASP HL keys, instruction manuals 170-8890 iscript cdna Synthesis Kit, 25 x 20 µl reactions, includes 5x iscript reaction mix, iscript reverse transcriptase, nuclease-free water 170-8892 iscript One-Step RT-PCR Kit With SYBR Green, 50 x 50 µl reactions, includes iscript reverse transcriptase for one-step RT-PCR, 2x SYBR Green RT-PCR reaction mix, nuclease-free water 170-8894 iscript One-Step RT-PCR Kit for Probes, 50 x 50 µl reactions, includes iscript reverse transcriptase for one-step RT-PCR, 2x probes RT-PCR reaction mix, nuclease-free water 172-5848 iq Multiplex Powermix, 50 x 50 µl reactions, 2x mix contains dntps, 11 mm MgCl 2, itaq DNA polymerase, stabilizers Cy is a trademark of GE Healthcare group companies. Excel, Microsoft, PowerPoint, Windows Vista, and Windows XP are trademarks of Microsoft Corporation. Quasar is a trademark of Biosearch Technologies, Inc. SYBR and Texas Red are trademarks of Invitrogen Corporation. Bio-Rad Laboratories, Inc. is licensed by Invitrogen Corporation to sell reagents containing SYBR Green I for use in real-time PCR, for research purposes only. Practice of the patented 5' Nuclease Process requires a license from Applied Biosystems. The purchase of these products includes an immunity from suit under patents specified in the product insert to use only the amount purchased for the purchaser s own internal research when used with the separate purchase of Licensed Probe. No other patent rights are conveyed expressly, by implication, or by estoppel. Further information on purchasing licenses may be obtained from the Director of Licensing, Applied Biosystems, 850 Lincoln Centre Drive, Foster City, California 94404, USA. Purchase of this instrument conveys a limited non-transferable immunity from suit for the purchaser s own internal research and development and for use in applied fields other than Human In Vitro Diagnostics under one or more of U.S. Patents Nos. 5,656,493, 5,333,675, 5,475,6 (claims 1, 44, 158, 160 163 and 167 only), and 6,703,236 (claims 1 7 only), or corresponding claims in their non-u.s. counterparts, owned by Applera Corporation. No right is conveyed expressly, by implication or by estoppel under any other patent claim, such as claims to apparatus, reagents, kits, or methods such as 5' nuclease methods. Further information on purchasing licenses may be obtained by contacting the Director of Licensing, Applied Biosystems, 850 Lincoln Centre Drive, Foster City, California 94404, USA. Bio-Rad s real-time thermal cyclers are licensed real-time thermal cyclers under Applera s United States Patent No. 6,814,934 B1 for use in research and for all other fields except the fields of human diagnostics and veterinary diagnostics. Bio-Rad Laboratories, Inc. Life Science Group Web site www.bio-rad.com USA 800 4BIORAD Australia 61 02 9914 2800 Austria 01 877 89 01 Belgium 09 385 55 11 Brazil 55 21 3237 9400 Canada 905 364 3435 China 86 21 6426 0808 Czech Republic 420 241 430 532 Denmark 44 52 00 Finland 09 804 22 00 France 01 47 95 69 65 Germany 089 318 84 0 Greece 30 2 777 4396 Hong Kong 852 2789 3300 Hungary 36 1 455 8800 India 91 124 4029300 Israel 03 963 6050 Italy 39 02 216091 Japan 03 6361 7000 Korea 82 2 3473 4460 Mexico 52 555 488 7670 The Netherlands 0318 540666 New Zealand 0508 805 500 Norway 23 38 41 30 Poland 48 22 331 99 99 Portugal 351 21 472 7700 Russia 7 495 721 14 04 Singapore 65 6415 3188 South Africa 27 861 246 723 Spain 34 91 590 5200 Sweden 08 555 12700 Switzerland 061 717 95 55 Taiwan 886 2 2578 7189 United Kingdom 020 8328 2000 Bulletin 5589 US/EG Rev A 07-0327 0308 Sig 1207