Configuration and Setup Guide. DICOM Image Viewer Version DICOM Recording Software on Flash IIP (CR-IR348CL)

Similar documents
9 Working With DICOM. Configuring the DICOM Option

CODESOFT Installation Scenarios

IT Quick Reference Guides Using Windows 7

Diamond II v2.3 Service Pack 4 Installation Manual

Network/Floating License Installation Instructions

Print Server Application Guide. This guide applies to the following models.

Gear View Basic. User Help. Version Written by: Product Documentation and R&D Date: August 2015 LX-DOC-GVB UH-EN-REVA

Allworx OfficeSafe Operations Guide Release 6.0

BSDI Advanced Fitness & Wellness Software

CENTRICITY WEB VERSION 3.0. Updated 11/24/2009 Medical Imaging IT Technical Support please call the Help Desk

Portions of this product were created using LEADTOOLS LEAD Technologies, Inc. ALL RIGHTS RESERVED.

ivms-4200 Client Software Quick Start Guide

MANUFACTURER RamSoft Incorporated 243 College St, Suite 100 Toronto, ON M5T 1R5 CANADA

NTI Backup Now EZ v2 User s Guide

BUS-WATCH R1001/R4001 Quick Guide Series

FaxFinder Fax Servers

Print Server Application Guide

Model 288B Charge Plate Graphing Software Operators Guide

File Management Utility. T u t o r i a l

ScanShell.Net Install Guide

STATISTICA VERSION 9 STATISTICA ENTERPRISE INSTALLATION INSTRUCTIONS FOR USE WITH TERMINAL SERVER

Infinity Web Viewer Reference Guide

Bosch ReadykeyPRO Unlimited Installation Guide, product version 6.5. This guide is item number DOC , revision 2.029, May 2012.

Table of Contents. CHAPTER 1 About This Guide CHAPTER 2 Introduction CHAPTER 3 Database Backup and Restoration... 15

JAVS Scheduled Publishing. Installation/Configuration... 4 Manual Operation... 6 Automating Scheduled Publishing... 7 Windows XP... 7 Windows 7...

Simple Computer Backup

STATISTICA VERSION 10 STATISTICA ENTERPRISE SERVER INSTALLATION INSTRUCTIONS

User Manual. Onsight Management Suite Version 5.1. Another Innovation by Librestream

How to use Backitup Modify Existing Schedule jobs

Lab: Data Backup and Recovery in Windows XP

Upgrading LytecMD from to 9.4 on Windows Server Best Practices. Revision Date: 7/29/2010 PLEASE READ:

Installation Instruction STATISTICA Enterprise Small Business

GUARD1 PLUS SE Administrator's Manual

How to use the VMware Workstation / Player to create an ISaGRAF (Ver. 3.55) development environment?

Now part of ALLSCRIPTS. HealthMatics EMR Input Manager

StrikeRisk v6.0 IEC/EN Risk Management Software Getting Started

Avalanche Remote Control User Guide. Version 4.1.3

Topaz Installation Sheet

Wireless Network Adapter Installation

Central Management Software CV3-M1024

NEWTECH INFOSYSTEMS, INC. NTI Backup Now EZ. NTI Backup Now EZ User's Guide

How schedule AccuTRConsole to run every hour

Motorola Phone Tools. Quick Start

efilm Scan 2.0 User Guide

MiraCosta College now offers two ways to access your student virtual desktop.

UltraBac Documentation. UBDR Gold. Administrator Guide UBDR Gold v8.0

Portions of this product were created using LEADTOOLS LEAD Technologies, Inc. ALL RIGHTS RESERVED.

Magaya Software Installation Guide

User Guide for Windows 10

Hosting Users Guide 2011

Head Office #5 Sugar Creek Road Piedmont, Missouri Tel: , option 2, sub-option 8 Fax: Dragonfly@avimark.net.

Quick Start Using DASYLab with your Measurement Computing USB device

JEROME COMMUNICATIONS SOFTWARE (JCS) INSTALLATION and OPERATION MANUAL V1.02 for Windows XP

AT&T Global Network Client v6.8.0 and Passport IP Setup Instructions for Broadband VPN Access

Specific Information for installation and use of the database Report Tool used with FTSW100 software.

Backing Up and Deleting Files

You can find the installer for the +Cloud Application on your SanDisk flash drive.

Lab - Data Backup and Recovery in Windows XP

User s Manual. Management Software for ATS

Step-by-Step Setup Guide Wireless File Transmitter

Introduction CDR Dicom for Windows is designed as a fully functional DICOM (Digital Imaging Communications of Medicine) based client-server

TOSHIBA GA Printing from Windows

Wireless USB Adapter

TECHNICAL BULLETIN. Configuring Wireless Settings in an i-stat 1 Wireless Analyzer

The following items are trademarks or registered trademarks of Kaba Mas in the United States and/or other countries. GITCON

Vess A2000 Series. NVR Storage Appliance. Windows Recovery Instructions. Version PROMISE Technology, Inc. All Rights Reserved.

Auto Archiving Folders in Outlook XP

Document Management System

Hi-Speed USB Flash Disk User s Manual Guide

Updates Click to check for a newer version of the CD Press next and confirm the disc burner selection before pressing finish.

SOFTWARE INSTALLATION INSTRUCTIONS

InventoryControl for use with QuoteWerks Quick Start Guide

Installing LearningBay Enterprise Part 2

ESET REMOTE ADMINISTRATOR. Migration guide

PN-L702B LCD MONITOR TOUCH PANEL DRIVER OPERATION MANUAL. Version 2.1

LPR for Windows 95/98/Me/2000/XP TCP/IP Printing User s Guide. Rev. 03 (November, 2001)

STATISTICA VERSION 12 STATISTICA ENTERPRISE SMALL BUSINESS INSTALLATION INSTRUCTIONS

64-Bit Compatibility with Micromeritics Applications

Chapter 4. Backup / Restore

Installation Guide v1.11 and Higher

BIGPOND ONLINE STORAGE USER GUIDE Issue August 2005

Secure Perfect RAID Recovery Instructions

TimeValue Software Due Date Tracking and Task Management Software

NAS 253 Introduction to Backup Plan

BankLink Books Clients

Guide to Installing BBL Crystal MIND on Windows 7

WA1826 Designing Cloud Computing Solutions. Classroom Setup Guide. Web Age Solutions Inc. Copyright Web Age Solutions Inc. 1

Image Backup and Recovery Procedures

i -CEN S USER S Manual

C6 Easy Imaging Total Computer Backup. User Guide

ScanWin Installation and Windows 7-64 bit operating system

ILTA HANDS ON Securing Windows 7

FrontDesk Installation And Configuration

IPRO Viewer. Installation

BSDI Advanced Fitness & Wellness Software

TSM for Windows Installation Instructions: Download the latest TSM Client Using the following link:

Dell Statistica Statistica Enterprise Installation Instructions

Moxa Device Manager 2.0 User s Guide

Loss of data can happen in many ways. One of the most common causes is hard drive failure. Hard drives can die without warning.

Practice Fusion API Client Installation Guide for Windows

Transcription:

Configuration and Setup Guide DICOM Image Viewer Version 3.0.0.7 DICOM Recording Software on Flash IIP (CR-IR348CL) Document No. INT-0011743-E Third Edition:

2 CONTROL SHEET Issue Date Revision# Reason Pages Affected 10.7.2010 00 DICOM CD/DVD burning software for the Flash IIP on Dell GX780 or newer. All Pages Copyright FUJIFILM Corporation 2009 All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by means, electronic, mechanical, photocopying, recording or otherwise, without the prior written permission of FUJIFILM Corporation, FUJIFILM Medical Systems USA division. 2 - DICOM Image Viewer V3.0.0.7 Configuration & Setup Guide INT-0011743-E

3 CONTENTS DICOM Image Viewer Software...4 1. Overview...4 2. Installing DICOM Viewer...5 3. Install HASP Driver...8 Configuring the Flash IIP for the DICOM Image Viewer...11 1. Entering the Flash IIP Service Utility mode...11 2. Setup This Host...12 3. Create New Node...14 4. Setup AE title and port...15 5. Create Abstract Syntax CRImageStorage...16 6. Create Abstract Syntax: Verification...19 7. Adding the LUT...20 8. Configuring DICOM Image Viewer to launch with Windows...21 9. Sending an image to the DICOM Image Viewer...25 Using DICOM Image Viewer...28 1. How to Burn CDs & DVDs using the DICOM Image Viewer software....28 2. Simple Viewer Patient List...29 3. Simple Viewer Image Window...30 INT-0011743-E DICOM Image Viewer V3.0.0.7 Configuration & Setup Guide - 3

4 DICOM Image Viewer Software 1. Overview DICOM Image Viewer is a software program that receives DICOM images from Fuji s Flash IIP software. All images are then added to a local database which can be queried by using usercustomized filter windows. The software allows you to archive patient exams by creating both CDs and DVDs. You may choose to create single patient CDs with a mini-viewer for referrals as well as archive multiple patients onto DVD with a DICOM directory for disaster recovery, or transfer to another PACS. The FMSU software part number is X-CD-VWR-SW-03. The new DICOM Image Viewer software does not require the installation of Nero Burning Software. 4 - DICOM Image Viewer V3.0.0.7 Configuration & Setup Guide INT-0011743-E

5 2. Installing DICOM Viewer 1. Insert the CD labeled DICOM Image Viewer Installation CD NOTE: If CD does not automatically load, click Start, All Programs, My computer and doubleclick on FujiCDCreator 2. You should see these files: DICOM Image Viewer the software program to burn CDs & DVDs HASP USB Setup the software program to recognize USB security dongles Version3.0.0.7 INT-0011743-E DICOM Image Viewer V3.0.0.7 Configuration & Setup Guide - 5

6 3. Double-click DICOM Image Viewer 4. Click [Next] to continue 5. Click [Yes] to continue 6 - DICOM Image Viewer V3.0.0.7 Configuration & Setup Guide INT-0011743-E

7 6. Click [Next] to continue 7. Progress Bar will display in next window 8. Click [Finish] upon completion NOTE: If you received a USB security dongle as part of your installation package, you must continue to step 3 to load the HASP driver for the software to operate when the security USB dongle is plugged into a USB port on the Flash IIP workstation. If you did not receive a USB security dongle, you will be prompted to license the software manually by email or phone when you run the software for the first time. INT-0011743-E DICOM Image Viewer V3.0.0.7 Configuration & Setup Guide - 7

8 3. Install HASP Driver 1. To load the HASP driver, double-click HASP USB Setup 2. HASP device driver screen will appear 3. Click [Next] to begin installation 8 - DICOM Image Viewer V3.0.0.7 Configuration & Setup Guide INT-0011743-E

9 4. Select I accept the license agreement and then click [Install] 5. Please wait for the drivers to install 6. To complete installation, click [Finish] 7. A license code must be provided by 1 of 2 methods: Code supplied by Genesis This can be obtained by sending an email to or calling Genesis with the License Key provided by the application. INT-0011743-E DICOM Image Viewer V3.0.0.7 Configuration & Setup Guide - 9

10 E-mail: Sales@genesisdigital.com Phone: 1-888-436-3444 USB Dongle If you received a USB security dongle as part of your installation package, plug it into a USB port on the Flash IIP workstation, the HASP driver will recognize it and open the program. 8. Remove the CD from the CD-ROM drive. 10 - DICOM Image Viewer V3.0.0.7 Configuration & Setup Guide INT-0011743-E

11 Configuring the Flash IIP for the DICOM Image Viewer 1. Entering the Flash IIP Service Utility mode 1. From the Flash IIP desktop, double-click the FCR Icon 2. Within a period of 5 seconds after the application splash screen window opens, sequentially click the upper left then upper right corners of the window. 3. The Service Utility mode will start and the IIP Service Utility window opens. A password is required for version 7.0 or higher. REFERENCE If you cannot complete step (2) above from the initial window within a 5 second period and allow the AP to start up, perform the following steps to start the Service Utility mode. To exit the AP, hold down the <Shift> key and select Shut Down on the FUJIFILM menu and repeat steps 1 and 2 above. INT-0011743-E DICOM Image Viewer V3.0.0.7 Configuration & Setup Guide - 11

12 4. Select the Setup Configuration button. 2. Set up This Host 1. Select NETWORK CONFIG, then DICOM, and highlight FCR-CSL. 2. Click on [New] 3. Choose [CRImageStorage] for [Abstract Syntax] and choose [SCU] for [Role] and click [OK] 12 - DICOM Image Viewer V3.0.0.7 Configuration & Setup Guide INT-0011743-E

13 4. Click on [New] 5. Choose [Verification] under [Abstract Syntax] and Choose [SCU] for [Role] and click [OK] 6. Click [Config] in top left corner and choose [Save] INT-0011743-E DICOM Image Viewer V3.0.0.7 Configuration & Setup Guide - 13

14 3. Create New Node 1. Click on the plus sign next to NETWORK CONFIG if not opened 2. Click on ALL OTHER NODES (which is under NETWORK CONFIG) until highlighted 3. Click NEW to bring up New Node box 4. In the field for HostName type OMNIVUE 5. In the field for IP address type the local IP address NOTE: To identify the IP address, first go to Start and then Run. Type in [cmd] and hit Enter and a box with a DOS prompt will pop up. Type in [ipconfig] and hit Enter. Your IP address will then be displayed. Close out of the box. 6. Choose the radio button DICOM 7. Click OK to bring up Application Entity List Box 14 - DICOM Image Viewer V3.0.0.7 Configuration & Setup Guide INT-0011743-E

15 4. Setup AE title and port 1. In the Application Entity Name field type OmniVue 2. In the Port Number field type 4810 3. Click [New] to bring up DICOMSetup Box INT-0011743-E DICOM Image Viewer V3.0.0.7 Configuration & Setup Guide - 15

16 5. Create Abstract Syntax CRImageStorage 1. In the Abstract Syntax drop down box choose: CRImageStorage 2. For the Role radio button choose: SCP 3. In the Transfer Syntax drop down box choose: ImplicitVRLittleEndian 16 - DICOM Image Viewer V3.0.0.7 Configuration & Setup Guide INT-0011743-E

17 4. In the Acceptable Density field choose: ST & HQ & SH 5. In the Default Output Density field choose: HQ/SH 6. In the Image Processing field choose: PROC INT-0011743-E DICOM Image Viewer V3.0.0.7 Configuration & Setup Guide - 17

18 7. In the LUT Operation field choose: Apply LUT correction process to the image NOTE: If the IIP application software is V5.0 or earlier, choose 10-bit from the bit field box. Recommend use of 12-bit for V5.0. 8. Click OK to go to the Application Entity List Box 18 - DICOM Image Viewer V3.0.0.7 Configuration & Setup Guide INT-0011743-E

19 6. Create Abstract Syntax: Verification 1. Click New to bring up DICOM Setup Box 2. In the Abstract Syntax drop down box choose: Verification 3. In the Role radio button field choose: SCP INT-0011743-E DICOM Image Viewer V3.0.0.7 Configuration & Setup Guide - 19

20 4. Click OK go to the Application Entity List Box 5. Choose OK again to go to Setup Configuration Box 6. Click Config, Close and Save 7. Close out of Service Utility 7. Adding the LUT 1. Go to C:\Program Files\FujiFilm\IIP\CrtLut 2. If the IIP application software is V4.1, choose mono_pl300 LL.lut and copy and paste and rename in same folder to the AE title which is OmniVue.lut 20 - DICOM Image Viewer V3.0.0.7 Configuration & Setup Guide INT-0011743-E

21 3. If the IIP application software is V5.0, and 12 bit is selected, choose mono_pl300_ll_16.lut and copy and paste and rename in same folder to the AE title which is OmniVue.lut 8. Configuring DICOM Image Viewer to launch with Windows 1. From the Windows desktop, right click the My Computer Icon and select Explorer INT-0011743-E DICOM Image Viewer V3.0.0.7 Configuration & Setup Guide - 21

22 2. Once in Windows Explorer, navigate to: C:\Documents and Settings\All Users\Start Menu\Programs\Startup 3. From the Desktop, right click the OmniVue icon and select Copy. 22 - DICOM Image Viewer V3.0.0.7 Configuration & Setup Guide INT-0011743-E

23 4. From inside the Startup folder, right mouse click and paste the OmniVue shortcut if not already there. 5. When complete, you should see the shortcut in the Startup folder as shown. INT-0011743-E DICOM Image Viewer V3.0.0.7 Configuration & Setup Guide - 23

24 6. Restart the PC and allow it to launch to IIP. Verify the DICOM Image Viewer software starts automatically by pressing [Alt] and [Tab] simultaneously. If the software did not start review section 2.8. 7. Be sure the dongle is attached if one was sent. If not, enter license code and when prompted log on with Genesis as the password. 24 - DICOM Image Viewer V3.0.0.7 Configuration & Setup Guide INT-0011743-E

25 9. Sending an image to the DICOM Image Viewer 1. Open the IIP application and choose the [All] Tab. 2. Select and open a study from worklist. 3. Click the [Delivery] tab and click the computer icon. INT-0011743-E DICOM Image Viewer V3.0.0.7 Configuration & Setup Guide - 25

26 4. Click the computer icon with the plus sign. 5. Choose OmniVue. 26 - DICOM Image Viewer V3.0.0.7 Configuration & Setup Guide INT-0011743-E

27 6. Click OK, and OK. 7. Click Deliver Study icon. INT-0011743-E DICOM Image Viewer V3.0.0.7 Configuration & Setup Guide - 27

28 Using DICOM Image Viewer 1. How to Burn CDs & DVDs using the DICOM Image Viewer software. Follow the steps as outlined below using the provided screen captures. 1. Search Field(s) and enter patient information (Sex, Patient ID, Modality, Disease, Study Description, Study Date Range, etc.) 2. Search button will display a patient list that matches the Search Fields you have chosen 3. Select Exam(s) from patient list (to select multiple exams use Shift or Ctrl key) 4. Compression Level can be selected from the drop-down menu (see diagram) 5. Copy or Move and add Copy Simple Viewer and Include DICOM DIR NOTE: The Move option is the preferred method to ensure the images are deleted from OmniVue or it will fill up the IIP HDD making the IIP inoperable. Copy will burn a copy of the selected exams to CD/DVD and leave the originals in the Omni-Vue patient list Move will burn all selected exams to CD/DVD and delete the originals from the Omni-Vue patient list Simple Viewer will add an application that will self load when the CD is loaded on another computer and allow image manipulation. This is most commonly used when Copy and Simple Viewer are selected together to burn single patient exams onto CD for referrals Include DICOM DIR will add a DICOM Directory of patient data so the selected exams can be loaded onto other DICOM viewers and PACS systems. This is most commonly used when Move and Include DICOM DIR are selected together to create an archival DVD backup of selected images to be stored at another location for disaster recovery 6. Backup will start the burning process 28 - DICOM Image Viewer V3.0.0.7 Configuration & Setup Guide INT-0011743-E

29 2. Simple Viewer Patient List When Copy Simple Viewer is selected during CD burning, it will launch the Simple Viewer application automatically when the patient CD is inserted into the CD drive of a Windows XP or Vista computer system. Simple Viewer is a DICOM viewing application that allows you to view and manipulate images saved onto the CD database. 1. When the CD is inserted, it will Autoplay and automatically display the Patient Exams burned onto the CD 2. To narrow the selection of displayed patient exams, you may select your Search Field(s), enter patient information and then click Search button to display a patient list that matches the Search Fields you have chosen 3. Select Exam(s) from patient list (to select multiple exams use Shift or Ctrl key) 4. Click Open to view images in the Simple Viewer image window (or double-click Exams) 5. As an option, you can select Send to use DICOM Storage Class User to send exams to another PACS or Viewer location INT-0011743-E DICOM Image Viewer V3.0.0.7 Configuration & Setup Guide - 29

30 3. Simple Viewer Image Window Viewing Options Include: Image Manipulation Options Include: Chest CT Window Level Scout Auto Window Level Stack/Tile Inversion 2 Vertical Display Real Size 2 Horizontal Rotation CW, CCW 2x2 Flip Horizontal, Vertical DICOM Header Zoom Pan Magnifying Glass Length Measurement Angle Measurement Compare Measure Cobb Angle ROI (4 formats) Annotation Pick Profile Pixel View 30 - DICOM Image Viewer V3.0.0.7 Configuration & Setup Guide INT-0011743-E

INT-0011743-E FUJIFILM Medical Systems USA, Inc. 419 West Avenue, Stamford CT 06902