Ensure safer & longer trips by choosing the right battery

Similar documents
By Exide Technologies /

If you accidentally get battery acid on your skin, flush it with lots of water

Optimising the daily operation of industrial trucks

Uptimax New Generation Ni-Cd battery. Maintenance-free solution for backup power applications

Battery Model: 25 Part Number: Nominal Voltage: 12 volts NSN: Number applied for, product currently available

Cat Batteries. Cat Batteries Greater Starting Power Lower Maintenance Longer Life

Small Traction powerbloc powerbloc dry Hawker XFC TM

THE FIRST NAME IN BATTERIES

ACHIEVING CHARGE QUALITY FOR LEAD ACID BATTERIES IN INDUSTRIAL MOTIVE APPLICATIONS

The most complete line of premium quality marine batteries in the industry FLOODED AGM GEL

MANUAL D250S DUAL. Solar panel + Vehicle ground/solar panel

Constant Voltage Charger Selection for VRLA Batteries

NP Series VALVE REGULATED LEAD-ACID BATTERIES

SPECIFICATIONS. Recommended Battery sizes (Maintenance) AUTOMOTIVE CCA CCA MARINE MCA MCA DEEP CYCLE 17 55Ah 17 80Ah

Tel.X Ni-Cd battery. The compact maintenance-free solution for telecom networks

Bosch C3 and C7 Battery Chargers: Smart, safe and simple to use

Tel.X Ni-Cd battery. The compact solution for stationary applications

Evolion Li-ion battery. Saft s proven ultra-compact solution for telecom applications

1. Connect the charger to the battery. 2. Connect the charger to the wall socket. 3. Press the MODE-button to select charging program.

RENEWABLE BROCHURE. World Class Battery Engineering Flooded & AGM Batteries

MANUAL. * Supply plugs may differ to suit your wall socket. EN 3. Continue to press the MODE-button to combine charging program with charging options.

Charge Regulator SCR 12 Marine

BATTERY BASICS. This Automotive Series 12-volt Lead Acid BATTERY BASICS has been developed by. Kevin R. Sullivan

RO 340 ECO. The challenge of obtaining maximum energy efficiency has been overcome with the following: Maximum efficiency of each of its components:

TROJAN BATTERY USER S GUIDE

OESAA Original Equipment Suppliers Aftermarket Association

Industrial Batteries / Motive Power Chargers 2100.NET.»For improved efficiency and durability«

Saft stationary batteries. A wide offer of reliable, long-life solutions

Switch Mode, Automatic, Lead Acid Battery Charger 3 Stage (IUoU)

The Critical Role of AGM Separators in VRLA Car Battery Performance. By George Zguris

Battery Product Line Complete Attention To Customer Satisfaction and World Class Efficiency!

LIST OF CONTENTS STARTING DEVICES. Bull Starter 12V Bull Starter 12/24 V Genesis EP16 Memory Saver P 3 Professional Booster Cables for Car and Truck

DataSafe HX Top Terminated Batteries 6 and 12 Volt HX

Industrial Batteries System solutions for railways.

Catalogue. 2 Wheel Drive Tow Carts Model Part No Picture Description Packaging. info@helitowcart.com

OUTPUT CABLE CONNECTIONS:

Simply the most user friendly battery charger in the world. now everyone can recharge their own batteries

Golf / Utility Vehicles

Industrial Batteries Network Power Sonnenschein Solar Safe storage capacity for renewable energy. Specifications

MANUAL EN 3. Continue to press the MODE-button to combine charging program with charging options.

Instructions: Retain these instructions for future reference SmartChargePro35 RSCPR35-12v, 2 / 8 / 16 / 35A

BATTERY SERVICE. This Automotive Series BATTERY SERVICE has been developed by. Kevin R. Sullivan. Professor of Automotive Technology Skyline College

THE BATTERY THAT GOES TO EXTREMES

Height w/o Terminals (in)

STARTER BATTERIES TRUCK BATTERIES NEW

MANUAL EN 3 SUPPLY PLUG* MAINS CABLE CTEK COMFORT CONNECT ABSORPTION, READY TO USE ANALYSE FLOAT, FULLY CHARGED PULSE, MAINTENANCE CHARGING

Charger Output AC Ripple Voltage and the affect on VRLA batteries

Battery guide. ResMed Ltd 1 Elizabeth Macarthur Drive Bella Vista NSW 2153 Australia Tel: Fax: ABN

OWNER S MANUAL THE BATTERY THAT GOES TO EXTREMES

The new era. The new Active Line

EN 3 ABSORPTION, READY TO USE ANALYSE BULK DESULPHATION SOFT START. L: 2000 mm MODE- BUTTON SUPPLY PLUG* SUPPLY

MXS 3. MANUAL FULLY CHARGED PULSE, MAINTENANCE CHARGING EN 3 SUPPLY PLUG* MAINS CABLE CTEK COMFORT CONNECT CHARGE CABLE ERROR LAMP MODE- BUTTON

BATTERY BOX INSTALLATION WARNING WARNING CAUTION ATTENTION AVERTISSEMENT ADVERTENCIA PRECAUCIÓN SOLBBOX12V CARTON INVENTORY COMPLETED OVERVIEW

Lead Acid Battery Terminology Glossary

Sunica.plus Ni-Cd batteries. The robust daily cycling solution for off-grid solar PV systems

LEAD CRYSTAL. User Manual. Valve-regulated lead-crystal batteries Energy storage Cells

A reasonable, new furnace (mid efficiency) has the following electrical requirements:

Maintenance-free sealed lead accumulators. HAGEN drysafe

A comparative analysis of Lithium Iron Phosphate and Lead-Acid (flooded, gel and AGM) battery technology for marine applications

Saft railway batteries. Solutions for a world in motion

The ebike Rechargeable Battery Guide

LITHIUM-ION ENERGY MODULES HEM & HPM SERIES

Battery charger. Art.no Model CB5-5L-BS1 ENGLISH SVENSKA NORSK SUOMI. Ver Original instructions

REDI-LINE ELECTRIC GENERATORS USER'S GUIDE. Rugged, Reliable, DC to AC Power Conversion

Energy Unlimited. Reinout Vader

T-SERIES INDUSTRIAL INCLINOMETER ANALOG INTERFACE

Technical Manual. Powersports Batteries

THE U.S. ARMY BATTERY MAINTENANCE MANAGEMENT PROGRAM BATTERY MAINTENANCE MANAGEMENT PROGRAM

Cabela's Advanced Angler Prosport II Chargers. Set Number SKU

SELECTION GUIDE FIFTH EDITION

Industrial Batteries Network Power Sonnenschein Solar Safe storage capacity for renewable energy. Specifications

Hand Crank Generator (9 May 05) Converting a Portable Cordless Drill to a Hand Crank DC Generator

LEAD ACID BATTERY working LIFETIME STUDY

Height w/o Terminals (in)

SOLAR POWER - THE NEW WAY TO RV!

Effects of AC Ripple Current on VRLA Battery Life. A Technical Note from the Experts in Business-Critical Continuity

EXTREME POWER AND ENDURANCE

DC Electronic Loads 8500 series

BATTERY CHARGER OPERATOR'S MANUAL

MULTI XS Battery charger. For lead-acid batteries 1,2-120Ah

BATTERY CHARGING GUIDELINES FOR 6-VOLT DEEP CYCLE BATTERIES

XDOC-MK-05 June 2011english. H y b r i d S y s t e m

875 Dearborn Drive Columbus, Ohio Tel: (614) Fax: (614)

6 CHARGE & START. ALTERNATORS STARTERS BATTERIES Cables Terminals ConneCTors. Parts for Trucks, Trailers & Buses

1. Safe Operation - Please be careful while operating the Rickshaw: the motor is fairly strong so be cautious while engaging the throttle.

AND VARTA REPRESENTS TRUE STRENGTH. 2010/2011 AUTOMOTIVE CATALOGUE. Thanks go to Peugeot,

Solar Wind Microhydro Water Pumping Inverters Batteries Professional system design and installation

Before installing unit, please carefully look over Installation Guide.

12-Volt Negative Ground Installation Instructions

CHARGING SYSTEMS INTERNATIONAL

400 Amp Rechargeable Jump Start System RAC-HP082

Maxi Sky 2 Plus The complete ceiling lift system

Temperature Compensated Charging of Lead Acid Batteries

Table Of Contents

Proposed Project For Exide Technologies Bristol, Tennessee - New NEPA Analysis

Substation Battery & Charger Maintenance

RADIANT PLASMA 4700 Plasma Spark Generator

AUTO CHARGE 3 STEP AUTOMATIC BATTERY CHARGER

12V Battery Charger & Engine Starter

Battery Handbook. By: RON SMITH

Transcription:

Ensure safer & longer trips by choosing the right battery On board, safety and comfort during navigation depend on the electrical supply to boat equipment. Usually provided by batteries, the supply is capable of powering key operations such as engine start, radio/gps supply and navigation lighting. As efficient energy storage is crucial to keep the boat moving, EXIDE presents the new battery offer, able to cover all the energy needs of both professional installers and private users. How to select the best battery solution in three steps By choosing the right battery, the electrical supply will last longer, ensuring enhanced trip duration and comfort. 1 Identify the boat s energy needs New premium batteries are also a preferred choice for boat builders. Thanks to DNV approval, it is simpler to get authority in accordance with European naval regulations for newly built boats. 2 Identify the boat s electrical configuration to find the right battery combination 3 Select the best battery technology according to its conditions of use

1 Identify the boat s energy needs Three basic energy needs are involved in marine battery uses ENGINE START NEED Supplied Power Power for starting a combustion engine requires high peaks of power during a short time, leaving batteries unused for the rest of the journey. The electrical unit used to measure engine start need is MCA* Journey duration DUAL SUPPLY NEED Supplied Power Power for starting together with the supply to other electrical equipment requires high peaks of power but also a variable power drain, causing battery discharge during the journey. The electrical unit used to measure dual supply need is Wh* Journey duration SUPPLY NEED Supplied Power An uninterrupted supply to emergency or comfort equipment uses power at high levels consistently, causing deep battery discharge during the journey. The electrical unit used to measure equipment supply need is Wh* Journey duration *MCA = BCI Marine Cranking power in Amps at 0ºC *Wh = Available Watt x hour at 20h rate from a battery, without exceeding its recommended depth of discharge

2 Identify the boat s electrical configuration to find the right battery combination The boat s electrical configuration determines the battery combination A. Engine only Boats for which batteries are applied to engine start only, with electrical equipment not supplied when the engine is switched off. This configuration corresponds to Engine start need. B. Engine & Equipment Boats for which one unique bank of batteries has to supply power for engine start but also for electrical equipment. This configuration corresponds to Dual supply need. C. Engine + Equipment Boats for which 2 separated banks of batteries are dedicated to supply power, one for engine start and the other for electrical equipment. This configuration corresponds to two needs: Engine start plus Equipment supply. In consequence, 2 different battery solutions are required. D. Engine + Equipment + Other Boats for which, in addition to 2 main battery banks (engine + equipment), other batteries are installed to supply power directly to electrical winches, thrusters or trolling motors. This configuration corresponds to three needs: Engine start plus Equipment supply plus Dual supply. In consequence, 3 different battery solutions are required.

Each energy need has its optimal battery option ENGINE START NEED START battery range is designed to supply high power for engine start when installed alone for basically equipped boats (case A) but can also be used when included in engine dedicated battery banks for the most sophisticated yachts (cases C&D). This engine start need keeps batteries normally charged during use as the alternator quickly returns consumed power. The START design provides good performance and service life duration. START battery range, with MCA* performance from 500A to 1400A, is the choice to cover all engine start needs from small outboards to big sterndrives. START DUAL SUPPLY NEED DUAL battery range is designed to supply power for boats having one battery bank for all consumers (case B) but is also suitable for additional batteries directly applied to electrical winches, thrusters and trolling motors (case D). This dual supply need holds batteries partially discharged during use so DUAL reinforced design, together with a good recharging procedure, is key to providing the best result and service life duration. DUAL battery range, with Wh* performance from 350Wh to 2100Wh, is the choice to cover all dual supply needs for the most popular recreational boats. DUAL SUPPLY NEED battery range is designed to supply power for boats with dedicated battery banks for equipment with applications such as navigation, emergency, safety and comfort (cases C&D). This equipment supply need keeps batteries partially or even deeply discharged during use so the special design, together with a good recharging procedure, is key to providing the most reliable result and service life duration. range, with Wh* performance from 290Wh to 2400Wh, is the choice to cover all equipment supply needs, from small electronics to emergency power. *MCA = BCI Marine Cranking power in Amps at 0ºC *Wh = Available Watt x hour at 20h rate from a battery, without exceeding its recommended depth of discharge

3 Select the best battery technology according to its conditions of use Battery conditions of use determine the right battery technology ENGINE START NEED 2 technologies with specific features & benefits are available for engine start need. START START AGM START & START AGM Marine cranking power coverage at 0ºC* MCA START START AGM 1500A (wide box) 1000A 500A (narrow box) * Referred to BCI standard for Marine Cranking Amperes (MCA) Low Low Low Gas Emission Low Gas Emission 25 Slight Inclination Low maintenance Located in special container Upright mount Free Free 90 Absolutely maintenance free Suitable for long resting periods Euis non utpatuerit No location constraints (safe for cabin mount) Safe and clean (spark & spill-proof) Euis non utpatuerit Suitable for side mount High vibration & tilt resistant Euis non utpatuerit 13,0V 12,3V Open Circuit Voltage START & START AGM Shelf life at 20ºC START START AGM 12 24 START & START AGM Vibration resistance at 6g/35Hz* Month Slight Inclination Up to 50% time for recharge saved START AGM ORBITAL Faster Recharge Faster Recharge Euis non utpatuerit START AGM FLAT START Lead/Acid flooded in Ca/Ca alloy up to 850A or Sb/Ca above with plug venting AGM Flat plate or Orbital plate in Ca/Ca alloy with VRLA venting 2 20 60 Hours * Referred to EN50342

DUAL DUAL SUPPLY NEED 2 technologies with specific features & benefits are available for dual supply need. DUAL AGM DOD 100% DUAL & DUAL AGM Depth of discharge at 20ºC 50% DUAL DUAL AGM 250 500 750 Cycles Low Low Low Gas Emission Low Gas Emission 45 Med Inclination Low maintenance Located in special container Spark arrestor & central degassing for safe gas conduction Upright mount Medium vibration & tilt resistant Free Free 90 Absolutely maintenance free Suitable for long resting periods No location constraints (safe for cabin mount) Safe and clean (spark & spill-proof) Suitable for side mount High vibration & tilt resistant 13,0V 12,3V Open Circuit Voltage DUAL & DUAL AGM Shelf life at 20ºC DUAL DUAL AGM 12 24 Month DUAL & DUAL AGM Vibration resistance at 6g/35Hz* Med Inclination Top Charge Indicator Top indicator for electrolyte & charge inspection Faster Recharge Faster Recharge Up to 50% time for recharge saved DUAL AGM FLAT DUAL DUAL AGM ORBITAL Lead/Acid flooded in Sb/Ca alloy with central degassing AGM Flat plate or Orbital plate in Ca/Ca alloy with VRLA venting 2 20 60 Hours * Referred to EN50342

SUPPLY NEED 2 technologies with specific features & benefits are available for equipment supply need. GEL & GEL Depth of discharge at 20ºC DOD 100% GEL 50% 250 500 750 Cycles Low Low maintenance Free Absolutely maintenance free Suitable for long resting periods & GEL Shelf life at 20ºC Open Circuit Voltage Low Low Gas Emission Low Gas Emission 45 Med Inclination Located in special container Upright mount Medium vibration & tilt resistant Free 90 No location constraints (safe for cabin mount) Safe and clean (spark & spill-proof) Suitable for side mount High vibration & tilt resistant 13,0V 12,3V GEL 12 24 Month & GEL Vibration resistance at 6g/35Hz* Med Inclination Up to 30% space for batteries saved GEL Compact Size Compact Size Lead/Acid flooded in Sb alloy and glass mat separators with plug venting GEL (jellified electrolyte) flat plate in Ca/Ca alloy with VRLA venting 2 20 60 Hours * Referred to EN50342

Technical specifications START AGM START CODE GEL TECHNOLOGY PERFORMANCES DIMENSIONS TECHNICAL CHARACTERISTICS AGM Flat AGM Orbital MCA* A (BCI) Capacity Ah (20h) CCA A (EN) L EM 900 900 42 700 230 173 206 1 Standard + Threaded 16 G86 EM1000 1000 50 800 260 173 206 1 Standard + Threaded 18 G34 EM1100 1100 100 925 330 173 240 9 Standard + Threaded 33 G31 EN 500 500 50 450 210 175 190 0 Standard 13 L01 EN 600 600 62 540 242 175 190 0 Standard 15 L02 EN 750 750 74 680 278 175 190 0 Standard 18 L03 EN 850 850 110 750 350 175 235 1 Standard 28 D02 EN 900 900 140 800 513 189 223 3 Standard 37 D04 EN1100 1100 180 1000 513 223 223 3 Standard 45 D05 EN1400 1400 225 1300 518 279 240 3 Standard 60 D06 W H Polarity Terminal Weight (kg) Box DUAL AGM DUAL GEL VINTAGE CODE GEL TECHNOLOGY PERFORMANCES DIMENSIONS TECHNICAL CHARACTERISTICS AGM Flat AGM Orbital Wh* Capacity Ah (20h) CCA A (EN) L EP 450 450 50 750 260 173 206 1 Standard + Threaded 19 G34 EP 900 900 100 720 330 173 240 9 Standard + Threaded 32 G31 EP1200 1200 140 700 513 189 223 3 Standard 45 D04 EP1500 1500 180 900 513 223 223 3 Standard 55 D05 EP2100 2100 240 1200 518 279 240 3 Standard 72 D06 ER 350 350 80 510 260 175 225 1 Standard 19 D26 ER 450 450 95 650 310 175 225 1 Standard 23 D31 ER 550 550 115 760 350 175 235 1 Standard 29 D02 ER 650 650 142 850 350 175 290 1 Standard 35 D03 ES 290 290 25 165 175 125 0 Flat Lug (M5) 10 P24 ES 450 450 40 210 175 175 0 Flat Lug (19) 15 LB1 ES 650 650 56 278 175 190 0 Standard 21 L03 ES 900 900 80 350 175 190 0 Standard 27 L05 ES 950 950 85 350 175 235 1 Standard 30 D02 ES1000-6 1000 190 (6V) 245 190 275 0 Standard 29 GC2 ES1100-6 1100 200 (6V) 245 190 275 0 Threaded insert 32 GC2 ES1200 1200 110 285 270 230 2 Standard 39 D07 ES1300 1300 120 350 175 290 0 Standard 39 D03 ES1350 1350 120 513 189 223 3 Standard 40 D04 ES1600 1600 140 513 223 223 3 Standard 47 D05 ES2400 2400 210 518 279 240 3 Standard 67 D06 ET 650 650 90 350 175 190 0 Standard 27 L05 ET 700-6 700 195 (6V) 245 190 275 0 Standard 30 GC2 ET 950 950 135 513 189 223 3 Standard 40 D04 ET1300 1300 180 513 223 223 3 Standard 50 D05 ET1600 1600 230 518 279 240 3 Standard 65 D06 Complementary range for old fitments. EU 72 72 620 491 111 249 1 Standard 16 3ET EU 77-6 77 (6V) 360 215 169 184 0 Standard 18 H02 EU 80-6 80 (6V) 600 158 165 220 0 Standard 11 M02 EU 140-6 140 (6V) 900 257 175 236 0 Standard 19 M04 EU 165-6 165 (6V) 900 330 174 234 0 Standard 25 M05 EU 200-6 200 (6V) 1150 398 174 234 0 Double 28 M06 EU 220 220 950 450 395 280 1 Standard 55 W00 EU 260-6 260 (6V) 1300 350 175 290 0 Standard 40 M08 W H Polarity Terminal Weight (kg) Box *MCA = BCI Marine Cranking power in Amps at 0ºC *Wh = Available Watt x hour at 20h rate from a battery, without exceeding its recommended depth of discharge i i To support distributors on battery dimensions and type recommendation, a CD-ROM is available to calculate Wh consumptions, series/parallel connections and required space for batteries. Jet-Ski or Scooters often used as service vehicles are fit by the EXIDE BIKE offer. E M 1000 CODE STRUCTURE BRAND RANGE NAME ELECTRICAL UNIT PERFORMANCE E EXIDE M START AGM MCA* 1000 1000 A NP START MCA* 1000 1000 A DUAL AGM Wh* 1000 1000 Wh R DUAL Wh* 1000 1000 Wh ST GEL Wh* 1000 1000 Wh Wh* 1000 1000 Wh U VINTAGE C20h 100-6 100 Ah/ 6V

By Exide Technologies / www.exide.com Exide Technologies SAS 5, allée des Pierres Mayettes 92636 Gennevilliers Cedex France Tél. : (33) 01 41 21 23 00 - Fax. : (33) 01 41 21 26 93 Société par Actions Simplifiée au capital de 38 524 860 R.C.S Nanterre B 682030895