The Figulla Flex II device. Carlos AC Pedra, MD, PhD, FSCAI



Similar documents
Effectiveness of the Amplatzer device for Transcatheter Closure of an Ostium Secundum Atrial Septal Defect

Kompleks Atriyal Septal Defektlerin Perkutan Kapatılmasına Uygun Hasta Seçiminde Gerçek Zamanlı Üç Boyutlu Transözafajeal Ekokardiyografinin Rolü The

Overview of Newer Stent Devices for Aneurysm Treatment

Percutaneous closure of paravalvular leaks EULOGIO GARCIA MD MADRID ~ SPAIN

Tracheal Stent System

Confirmed CCHD What next?

Step-by-step Approach to Paravalvular Leak Closure

Deflectable & Steerable Catheter Handbook

2015 WATCHMAN Left Atrial Appendage Closure Device (The WATCHMAN Device) Coding Guide- Structural Heart Contents

MEDICAL POLICY No R1 DRUG-ELUTING STENTS FOR ISCHEMIC HEART DISEASE

Ostial LAD: Single stent approach is the best. Antonio A. Pocoví, MD, FSCAI, MTSAC, Advisory Council Member, CACI

Answers to commonly asked questions from patients with metal-on-metal hip replacements / resurfacings. Contents

WallFlex Biliary RX Stent. Fully, Partially and Uncovered Self-Expanding Metal Stents

BSI Road Show: September 8 th to 15 th, 2014

Solid-State Relays (SSRs) vs Electromechanical Relays (EMRs)

Medical Devices. Driving Growth With Transformational Technology

.URGENT DEVICE CORRECTION

Clinical Commissioning Policy Statement: Percutaneous mitral valve leaflet repair for mitral regurgitation April Reference: NHSCB/A09/PS/b

Common types of congenital heart defects

Contraindications: Malign or benign strictures in the upper part of esophagus close to the cricopharyngeal muscle.

RECALLS in EUROPE. Past, present, near & further future. Gert Bos BSI Medcon May 2012

Quality Management System Certification. Understanding Quality Management System (QMS) certification

Degenerative Spine Solutions

PIHRATE Trial. Polish-Italian-Hungarian Randomized ThrombEctomy Trial. Dariusz Dudek MD, PhD. On behalf PIHRATE investigators

NEW HORIZONS IN CORNEAL SURGERY VERSATILE FEMTOSECOND LASER WORKSTATION WE FOCUS ON PERFECTION

Endoscopic therapy for obesity and complications of bariatric surgery

Worksoft Case Study 1

Questions FOETAL CIRCULATION ANAESTHESIA TUTORIAL OF THE WEEK TH MAY 2008

Majestic Trial 12 Month Results

LOMAS / MONDEFIT ORTHODONTICS. The most innovative anchorage method for tooth correction

Instructions for Use. Device Description The AMPLATZER Vascular Plug II is a self-expandable nitinol mesh occlusion device (see Figure 1).

6000 Series Buccaneer

OVER 45 YEARS TEXTILE GRAFT TECHNOLOGY EXPERIENCE MAQUET THE GOLD STANDARD

EndoWorld GYN 37-1-E/ TROPHYscope CAMPO Compact Hysteroscope

The Essential Role of CT Planning and TEE Guidance to Optimize Device Deployment

SAMPLE. Asia-Pacific Interventional Cardiology Procedures Outlook to Reference Code: GDMECR0061PDB. Publication Date: May 2014

Long-term follow-up after closure of patent foramen ovale

JUL Ms. Kendra Basler Regulatory Affairs Associate Abbott Vascular Cardiac Therapies 3200 Lakeside Drive Santa Clara, CA

The New Standard of Excellence, Redefining Deliverability, Versatility and Control

Real-Time 3-Dimensional Transesophageal Echocardiography in the Evaluation of Post-Operative Mitral Annuloplasty Ring and Prosthetic Valve Dehiscence

Tissue Reinforcement with Strattice Reconstructive Tissue Matrix following Correction of Severe Breast Deformity

FACTS about. MENTOR MemoryGel. Silicone Gel Filled Breast Implants

Atrial Septal Aneurysm: A Study in Five Hundred Adult Patients

Vigilance Reporting. Vicky Medley - Head of QMS, Medical Devices. September Copyright 2015 BSI. All rights reserved.

Vaginal Mesh: The FDA Decision and Repurcussions. Roger Dmochowski MD, FACS Dept of Urology Vanderbilt University Medical Center Nashville, TN

MЬKEMMEL MUTFAKLAR YARATIR CREATING THE PERFECT KITCHEN TЬV-CB ISO 9000 QUALITY MANAGEMENT SYSTEM TURKEY PRODUCT CETIFICATE RUSSIA PRODUCT

frequently asked questions Knee and Hip Joint Replacement Technology

Stilling Well Recommendations

Index. Registry Report

NATIONAL INSTITUTE FOR HEALTH AND CLINICAL EXCELLENCE. Health Technology Appraisal

Vinfoil Infigo SF110 UFC module for UV Film Casting application

Accelerating Light. Copper Cabling Solutions. Category 6A

Pulmonary Atresia With Intact Ventricular Septum - Anatomy, Physiology, and Diagnostic Imaging

Oil and Gas Pipeline Design, Maintenance and Repair

WSSC Ad-Hoc Committee on Large Diameter Water Mains. August 2, 2013

The Captivator II Snares are the first line of stiff and rounded snares available in multiple sizes with both a hot and cold snaring indication.

Regions Hospital Delineation of Privileges Cardiology

Treatment of Maxillary Sinusitis Using the SinuSys Vent-Os Sinus Dilation System

Airways Resistance and Airflow through the Tracheobronchial Tree

What do I need to know about Mesh Implants in Prolapse Surgery?

COATED CARBIDE. TiN. Al 2 O 3

Important Information: Complete Terms and Conditions are printed on sales invoices

PATIENT INFORMATION BOOKLET

Captivator II. Single-Use Snares

November 20, Vascular Flow Technologies Ltd. Edwin Lindsay VP of QA/RA Prospect Business Centre, Gemini Cresent Dundee DD2 1TY United Kingdom

Anticoagulation: How Do I Pick From All the Choices? Jeffrey H. Neuhauser, DO, FACC BHHI Primary Care Symposium February 28, 2014

Product Brief. DC-Protect. Content based backup and recovery solution. By DATACENTERTECHNOLOGIES

Scuffing Measurement Methodology and Improved Film Coating Systems

020 // Congenital Heart Disease

Product Innovations 2014/2. A Company of the SWAROVSKI Group

Endovascular Repair of an Axillary Artery Aneurysm: A Novel Approach

Case Study. Performance Testing of Medical Association Builder Portal. Case Study. US-based Non-profit Medical Association (Healthcare)

Precision Vise Combinations

Typical TIG-plasma solutions

2015 European Coronary Stent New Product Innovation Award

Single Mode Fiber Lasers

Guidance Notes for Applicants of the Certificate for Clinical Trial on Medical Device

Suffering from varicose veins? Patient Information. ELVeS Radial Minimally invasive laser therapy of venous insufficiency

Yukon Choice DES + Translumina - The polymer-free DES solution. Coronary Stent System for Drug Application

Program Design and Engineering Key to Infrastructure Replacement and Cost Containment

CPRD Clinical Practice Research Datalink Scotland Meeting May 2012

Cat7/Class F New Installation Concept New infrastructure. Handbook

Miniaturizing Flexible Circuits for use in Medical Electronics. Nate Kreutter 3M

Models SFP33 & SFP32 Pressure Transmitters

Overview. Total Joint Replacement in the U.S. KP National Total Joint Registry EMR Tools and Outcome Assessment: A Model for Vascular Surgery?

The Quality Connection. High Performance Cable Solutions for the World of Semiconductors

The Quality Connection. High Performance Cable Solutions for the World of Semiconductors

The High Cost of a Low-Cost Cable Certification Tester

Understanding changes to the Trust Services Principles for SOC 2 reporting

New and Improved Femtosecond Laser Applications. Karl Stonecipher, MD Wavefront Congress 2008

Talent Thoracic Stent Graft with THE Xcelerant Delivery System. Expanding the Indications for TEVAR

Transcription:

The Figulla Flex II device Carlos AC Pedra, MD, PhD, FSCAI

Flex II background The Flex II (ASD and PFO devices) represent the third generation of Occlutech ASD and PFO occluders following the Figulla N (CE marked in May 2007) and the Flex I device. 20000 implants have been performed worldwide with the Figulla family of ASD and PFO occluders. CONFIDENTIAL - Occlutech 2012. All rights reserved. www.occlutech.com 2

Figulla N and I Experience at IDPC and HCor 127 ASDs and 27 PFOs 1 embolization/1 mal position: retrieval No erosion 2 residual leaks (additional small defects) Pedra CAC, Braga SLN, Pedra SRFF, Costa RN, Braga SLN, Esteves CA, Fontes VF. Experiência Inicial no Fechamento Percutâneo da Comunicação Interatrial Tipo Ostium Secundum com a Prótese. Rev Bras Cardiol Inv 2010; 18: 81 88. 3

Use in challenging scenarios Pedra CAC, Pedra SF, Costa RN, Ribeiro M. The Occlutech Figulla Device. In: Sievert H, Qureshi S, Wilson N, Hijazi ZM, Franke J, Bertog S (eds.). Percutaneous Interventions in Structural, Valvular and Congenital Heart Disease. 2nd edition. Informa Healthcare. Oxford, UK. 2014. CONFIDENTIAL - Occlutech 2012. All rights reserved. www.occlutech.com 4

Use in challenging scenarios CONFIDENTIAL - Occlutech 2012. All rights reserved. www.occlutech.com 5

Use in challenging scenarios CONFIDENTIAL - Occlutech 2012. All rights reserved. www.occlutech.com 6

Use in challenging scenarios CONFIDENTIAL - Occlutech 2012. All rights reserved. www.occlutech.com 7

Use in challenging scenarios CONFIDENTIAL - Occlutech 2012. All rights reserved. www.occlutech.com 8

Use in challenging scenarios CONFIDENTIAL - Occlutech 2012. All rights reserved. www.occlutech.com 9

Use in challenging scenarios CONFIDENTIAL - Occlutech 2012. All rights reserved. www.occlutech.com 10

Use in challenging scenarios CONFIDENTIAL - Occlutech 2012. All rights reserved. www.occlutech.com 11

Use in challenging scenarios CONFIDENTIAL - Occlutech 2012. All rights reserved. www.occlutech.com 12

Figulla N and I Personal impressions Flexible device (larger sizes) No need for fancy maneuvers Excellent for large defects in adults Oversizing less of a problem? Pedra CAC, Braga SLN, Pedra SRFF, Costa RN, Braga SLN, Esteves CA, Fontes VF. Experiência Inicial no Fechamento Percutâneo da Comunicação Interatrial Tipo Ostium Secundum com a Prótese. Rev Bras Cardiol Inv 2010; 18: 81 88. 13

Use in challenging scenarios CONFIDENTIAL - Occlutech 2012. All rights reserved. www.occlutech.com 14

Use in challenging scenarios CONFIDENTIAL - Occlutech 2012. All rights reserved. www.occlutech.com 15

Use in challenging scenarios CONFIDENTIAL - Occlutech 2012. All rights reserved. www.occlutech.com 16

Devices features The device design that contain less metal gives more device flexibility and less cutting edges CONFIDENTIAL - Occlutech 2012. All rights reserved. www.occlutech.com 17

Device features The ceramic titanium oxide surface gives the golden aspect of the nitinol wires The nitinol wires used for ASD/PFO devices are 40-200 microns in diameter. The patch material is PET CONFIDENTIAL - Occlutech 2012. All rights reserved. www.occlutech.com 18

Device features The hubless left disc offers an atraumatic distal end entering the LA CONFIDENTIAL - Occlutech 2012. All rights reserved. www.occlutech.com 19

Bioptome-type delivery system Allows a full circular movement of the device Lower tension in the delivery system means that you see what you get CONFIDENTIAL - Occlutech 2012. All rights reserved. www.occlutech.com 20

Angled delivery system Less tension in the delivery cable means less flicking effect upon device release Less need to force the septum as the 50 degree angle allows adaptation to a large portion of septal anatomies CONFIDENTIAL - Occlutech 2012. All rights reserved. www.occlutech.com 21

Shapeable cable CONFIDENTIAL - Occlutech 2012. All rights reserved. www.occlutech.com 22

Proprietary braiding technology The proprietary braiding technology of Occlutech gives a device that looks and behaves distinctly different from other self-centering nitinol occluders CONFIDENTIAL - Occlutech 2012. All rights reserved. www.occlutech.com 23

Devices features The Occlutech devices are less prone by design for mushroom effects upon oversizing, hence the 3 mm increments of size CONFIDENTIAL - Occlutech 2012. All rights reserved. www.occlutech.com 24

Sizes CONFIDENTIAL - Occlutech 2012. All rights reserved. www.occlutech.com 25

Sizes CONFIDENTIAL - Occlutech 2012. All rights reserved. www.occlutech.com 26

Sizes CONFIDENTIAL - Occlutech 2012. All rights reserved. www.occlutech.com 27

Multifenestrated defects. Flex Uni CONFIDENTIAL - Occlutech 2012. All rights reserved. www.occlutech.com 28

Multifenestrated defects. Flex Uni CONFIDENTIAL - Occlutech 2012. All rights reserved. www.occlutech.com 29

Sheath compatibility The Flex II braiding technique reduces sheath requirements on average 20% as compared to Flex I. This means the ASD range going from 8-14 Fr to 7-12 Fr CONFIDENTIAL - Occlutech 2012. All rights reserved. www.occlutech.com 30

Sheath compatibility Pedra CAC, Pedra SF, Costa RN, Ribeiro M. The Occlutech Figulla Device. In: Sievert H, Qureshi S, Wilson N, Hijazi ZM, Franke J, Bertog S (eds.). Percutaneous Interventions in Structural, Valvular and Congenital Heart Disease. 2nd edition. Informa Healthcare. Oxford, UK. 2014. 31

Device features A dedicated Occlutech Delivery system, including a braided delivery sheath, is available Perfecting Performance Occlutech Delivery Set CONFIDENTIAL - Occlutech 2012. All rights reserved. www.occlutech.com 32

Fenestrated device CONFIDENTIAL - Occlutech 2012. All rights reserved. www.occlutech.com 33

Use in challenging scenarios Pedra CAC, Pedra SF, Costa RN, Ribeiro M. The Occlutech Figulla Device. In: Sievert H, Qureshi S, Wilson N, Hijazi ZM, Franke J, Bertog S (eds.). Percutaneous Interventions in Structural, Valvular and Congenital Heart Disease. 2nd edition. Informa Healthcare. Oxford, UK. 2014. CONFIDENTIAL - Occlutech 2012. All rights reserved. www.occlutech.com 34

Use in challenging scenarios CONFIDENTIAL - Occlutech 2012. All rights reserved. www.occlutech.com 35

Use in challenging scenarios CONFIDENTIAL - Occlutech 2012. All rights reserved. www.occlutech.com 36

Can design features affect the rate of EROSION? Erosion is a rare but potentially catastrophic complication of ASD/PFO closure The literature and the MAUDE data base puts the incidence at 1-2/1000 (ASO devices), i.e. 0.1-0.2% (FDA erosion panel) CONFIDENTIAL - Occlutech 2012. All rights reserved. www.occlutech.com 37

Occlutech erosion statistics With twenty thousand implants the real incidence should be 40 cases of erosions The reported number of erosions of the Figulla ASD/PFO occluders is ZERO. As a European manufacturer following CE/ISO rules, there is a complaint reporting system in place. CONFIDENTIAL - Occlutech 2012. All rights reserved. www.occlutech.com 38

Ways to further investigate these data Due to the rarity of erosion, it may not be feasible to do a randomized trial. Also difficult with registries. An independent third party could audit operators/hospitals and gather the data. The company could also initiate a registry for ASD implants with deficient rims. CONFIDENTIAL - Occlutech 2012. All rights reserved. www.occlutech.com 39

Future improvement potential of ASD/ PFO devices Reduce metal content and still provide an easy to use and intuitive device. Endothelial accelerator coating CONFIDENTIAL - Occlutech 2012. All rights reserved. www.occlutech.com 40

Thank you for your attention! CONFIDENTIAL - Occlutech 2012. All rights reserved. www.occlutech.com 41

Flex II background The Flex II (ASD and PFO devices) represent the third generation of Occlutech ASD and PFO occluders following the Figulla N (CE marked in May 2007) and the Flex I device. 20000 implants have been performed worldwide with the Figulla family of ASD and PFO occluders. Pedra CAC, Pedra SF, Costa RN, Ribeiro M. The Occlutech Figulla Device. In: Sievert H, Qureshi S, Wilson N, Hijazi ZM, Franke J, Bertog S (eds.). Percutaneous Interventions in Structural, Valvular and Congenital Heart Disease. 2nd edition. Informa Healthcare. Oxford, UK. 2014. 42

Time from implant to erosion Erosion data ;ASO devices (FDA erosion panel) CONFIDENTIAL - Occlutech 2012. All rights reserved. www.occlutech.com 43