Industry Alert. External walls and BCA compliance. Issued 24 February 2016I(Updated 28 June 2016)

Similar documents
Australian/New Zealand Standard

Practice Note

Fire 2This Technical Bulletin has been commissioned by the UK SIP Association in

fire separating walls #2

A GUIDE TO WINDOW AND DOOR SELECTION

FIRE SAFETY GUIDELINE

Release: 1. CPCCBS6010 Conduct and report on building surveying audits of residential buildings up to three storeys

Excerpts from the Canadian National Building Code (NBC)

EXPANDED POLYSTYRENE (EPS) INSULATION BOARD SPECIFICATIONS

The compliance of a roof to part of a new house at 28D Rata Street, Oxford, Waimakariri

Australian Transport Council. National Standard for the Administration of Marine Safety SECTION 4 SURVEYS OF VESSELS

FIRE LOSS STATISTICAL CONSIDERATIONS IN RELATING FAILURE AND BUILDING DAMAGE TO THE BUILDING CODE OBJECTIVES

Information Bulletin. Sprinkler System Component Fault Monitoring. Version 1.1 Approved for release September 2013

LIFE SAFETY UPDATE. FULL SPRINKLERING OF ALL NURSING FACILITIES ADDITIONAL CLARIFICATIONS Prepared by Eric Rosenbaum, P.E. Hughes Associates, Inc.

Approved Document Q: Security

Ai Group Submission. in response to the. ACCC Consultation on Evaporative Air Conditioners in Bushfire Prone Zones

CHAPTER 6 CONSTRUCTION TYPES

Multi-storey residential buildings - warranty insurance exemption. This updates the previous Practice Note issued June 2006

Nationwide House Energy Rating Scheme (NatHERS)

How To Build A Two Hour Firewall In Calgary

Building Code Clarifications - 7. Fire Resistance

Building Envelope Design by Roxul (BEDR ) FireWall and Roxul Plus MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

PROPOSED SPECIFICATION FOR ALUCOBOND PLUS Aluminium Composite Panel Cladding System Fixed Watertight Cassette Panel System - 4mm thick

Rockwool Cladding Roll

Fire Safety Requirements for Child Care Centre

Decree of the Ministry of the Environment on fire safety of ventilation systems

Standard the the Raising

New Zealand Fire Service. Design Review Unit. Audit

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

Know the Code: Using Spray Foam Insulation In Attics and Crawl Spaces

Practice Note

Assessing energy equivalence using the peer review process. Peer review guideline

Composite Panel Firewall Systems

Guidance on loft conversions in two-storey houses

Practice Note

Fire testing for BCA compliance

BS 476: Part 7: Method For Classification Of The Surface Spread Of Flame Of Products. A Report To: Gurit (UK) Ltd. Document Reference:

Number of Sides Required to Have a Handrail

FIRE AND SMOKE PROTECTION FEATURES

Building Permit Audit

SOUND INSULATION FOR EXTERIOR WALLS AND FACADE SYSTEMS

Services Enclosures and Protected Shafts - Maintaining Compartmentation

Building Envelope Design using ROXUL. FIREWALL and ROXUL PLUS MB. Fire Rated Board Insulation for Pre-Engineered Metal Buildings

Fiberglas, Exterior Wall Thermal Insulation

PB301 July Lightweight Building Solutions. Bushfire Protection.

Section 2.4. Built-up Metal Roofs. Rail and bracket system. Standing seam system. Bu02. Product: Earthwool FactoryClad range Bu01

Terms and Definitions In Canada

Document type: Practice Note Title: External and internal membranes Document number: AC2234 Version: Purpose

Installation Instructions

NRG 75 CRF NRG GREENBOARD WALL SYSTEM

Fire safety in buildings and implementation of European fire test standards

COMMERCIAL COOKING HOODS, VENTILATION & FIRE SUPPRESSION SYSTEM GUIDELINES AND PROCEDURES

DESIGNERS GUIDE TO DOMESTIC CONSERVATORIES

IMPACT DAMAGE RESISTANT WALL SYSTEMS

Understanding BS EN 771-3: Aggregate concrete masonry units

New Ontario Building Code Requirements for Mid-rise Wood Frame Buildings

Meeting the Fire Code with Continuous Foam Plastic Insulation

Rockwool Flexi Insulation Application Guide

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC CALIFORNIA BUILDING CODE 199

FIRE AND SMOKE PROTECTION FEATURES

Loss Prevention Standard

Requirements for Fire Protection of Light Weight Floor Systems **Act 1 Revisited**

Insulated Roof & Wall Panels. Product Data Sheet. Trapezoidal Insulated Roof Panels KS1000 RW

Enclosures DuraSystems Barriers, Inc. The Passive Fire Protection Specialists

Performance Standard for Secondary Containment

Planning for Bushfire Risk Mitigation General Code

The BASA Guide to the ISO Classification of Sealants for Building Construction

INSULATION FOR PRE-ENGINEERED METAL BUILDINGS. ROXUL SAFE 55 & 65 and ROXUL PLUS MB. Insulation for Pre-Engineered Metal Buildings

GYPSUM AREA SEPARATION FIREWALLS GA

H-Stud Area Separation Wall System

BUILDING CONTROL GUIDANCE SHEET REPLACEMENT WINDOWS AND DOORS Last updated 16/11/2010

THERMAL BARRIERS FOR THE SPRAY POLYURETHANE FOAM INDUSTRY

INTERNATIONAL ASSOCIATION OF CLASSIFICATION SOCIETIES. Interpretations of the FTP

Executive Summary Inclusion of Current Firewall Requirements in NBCC

Mansion on Bourke. 2 Mansion on Bourke Case Study S E R V I C E D A P A R T M E N T S

Loss Prevention Standard

SOUND INSULATION FOR GLAZED DOORS AND STANDARD DOORS

NATIONAL WORKERS COMPENSATION AND OCCUPATIONAL HEALTH AND SAFETY FRAMEWORKS

- 5 - Table1. Maximum Compartment Volumes

RISK MANAGEMENT FRAMEWORK

Colorcoat Technical Paper Fire performance of pre-finished steel cladding systems

Steel-framed Walls. Insulation

INFORMATION HANDBOOK. Applying energy efficiency provisions to new building work associated with existing Class 2 to 9 buildings

New Ontario Building Code Highlights

Test Report: ICL/H11/979. BS 7837: 1996 Flammability performance for textiles used in the construction of marquees and similar textile structures.

COMMERCIAL BUILDING APPLICATIONS

How to Install Modular Wiring, Cabling and Air Distribution Devices beneath a Access Floor without a Fire Suppression System

Auditing Health and Safety Management Systems. 4th Edition

FIREPROOF Panels Trimoterm

Gridstone Gypsum Ceiling Panels

3 Masonry and Manufactured Stone (Interior and Exterior)

What you need to know about. Being an owner-builder

Dubai Municipality Standard DMS 1: Part 5: 2004

MAJESTIC. OUTDOOR / INDOOR WOOD FIREPLACES Model: ODSR36A OWNERS INSTALLATION & OPERATING INSTRUCTIONS. KEEP THESE INSTRUCTIONS FOR FUTURE REFERANCE.

INSTRUCTIONS FOR COORDINATION SECTION SOLID SURFACE FABRICATIONS

Code Requirements for Existing Buildings

Certification: Building Plans Examiner. Exam ID: B3

Introduction. Facade Fire Test on PUR External Thermal Insulation Composite System (ETICS)

Contents. Finding A Builder...9. Subcontractors...9 Quotes And Estimates Owner Builders...11 Once Decided On A Builder...11

Fire-resistance test on fire collars protecting a concrete slab penetrated by services

Transcription:

I() External walls and BCA compliance Updated to include reference to the publication of AS 5113 Fire propagation testing and classification of external walls of buildings, and clarification of the meaning of external wall. Some terms are used in this Industry Alert which are common building terms but are not defined in the Building Code of Australia. For clarity, the meanings of terms used for the purpose of this Industry Alert are: Attachment means: A supplementary element attached to an external wall or other complete building element. BCA means: Volume One of the National Construction Code. Cladding means: A non-loadbearing covering of a wall system which contributes to the functionality of the external wall, usually but not limited to weatherproofing. (Note: This aligns with common dictionary meanings. External wall means: The entire wall system which separates the interior air space of the building with the outside air space including any componentry or elements necessary for the external wall to achieve the requirements for structural performance, weather tightness, thermal performance, noncombustibility and required FRL if required by the type of construction, and any other functionality required under the BCA. This definition excludes any linings, materials and assemblies complying with Clause C1.10 or attachments complying with Specification C1.1 Clause 2.4 that may be applied to the inner or outer surface of the already fully compliant wall. Lining means: Sheet material fixed as an attachment to the external face of an external wall. Except for external wall, terms in italics have the same meaning as in the BCA. PURPOSE Following the release of the Metropolitan Fire Brigade s post incident analysis report into the Lacrosse apartment fire and the completed Victorian Building Authority s (VBA) audit of Class 2, 3 and 9 buildings the VBA has become aware of considerable variation in industry understanding regarding the use of aluminium composite panels (ACP) and other combustible materials in the construction of external walls. The audit identified that combustible materials including ACP have been used in a manner that does not comply with Volume One of the Building Code of Australia. The purpose of this Industry Alert is to clarify circumstances where ACPs and other combustible materials may be used in the construction of the external walls of a building in Type A and Type B construction principally in relation to Class 2, 3 and 9 buildings. It is clear from the audit that Building designers, builders and building surveyors are failing to identify whether the material is being used as an integral part of an external wall, or used as an attachment to a complete wall system. This failure can lead to the non-compliant use of a combustible material as a component of a wall that is required to be non-combustible; Appropriate evidence of suitability in accordance with Clause A2.2 was commonly not being provided to, or sought by, relevant building surveyors; www.vba.vic.gov.au Page 1 of 6

Building designers specifying and relevant building surveyors approving generic brand products such as brand name or similar where a particular model of that branded product may comply and another model would not. Assessments of the use of materials as an attachment have frequently not included an assessment of the conditional requirements of Clause 2.4 of Specification C1.1. Those conditions are that o o o it is not located near or directly above a required exit so as to make the exit unusable in a fire; and it does not otherwise constitute an undue risk of fire spread via the facade of the building. the attachment of a facing or finish, or the installation of ducting or any other service, to a part of a building required to have an FRL must not impair the required FRL of that part While this Industry Alert focusses on ACP s the principles expressed apply to any other material that has not been deemed to be non-combustible in accordance with AS1530.1 or, under Clause C1.12, may be used where a non-combustible material is required and used as a component of an external wall or attachment to the external wall of a building. EVIDENCE OF SUITABILITY Evidence to support the use of a material, form of construction or design meets a Performance Requirement or Deemed-to-Satisfy Provision (D-t- S) as provided for by Clause A2.2 of the BCA may be in the form of: a report issued by a Registered Testing Authority (Registered with NATA or an authority recognised by NATA); a current Certificate of Conformity issued under the Australian Building Codes Board (ABCB) CodeMark scheme; a Certificate of Accreditation issued by the Building Regulations Advisory Committee; a Certificate issued under section 238 of the Act by a professional engineer registered in the appropriate discipline; a current Certificate issued by a product certification body accredited by the Joint Accreditation System of Australia and New Zealand (JAS-ANZ); Any other form of documentary evidence that correctly describes the properties and performance of the material or form of construction and adequately demonstrates its suitability for use in the building. A number of ACP s, and other combustible construction products or materials have been issued with Certificates of Conformity (Certificate) under the CodeMark scheme. Certificates must be read very carefully to identify the specific requirements of the BCA the building product or material is certified to comply with. If there is any doubt about a Certificate or other form of evidence of suitability, the body who issued the Certificate should be contacted for clarification. If a Certificate does not provide certainty to a designer or relevant building surveyor regarding the compliance of a product for the particular proposed use, it is not appropriate to rely on the Certificate. Certificates also commonly contain limitations or conditions for the installation and use of the building material. For instance, a common condition is a requirement that the building material or product must be installed in a particular manner or in accordance with a technical manual supplied by the manufacturer. If a Certificate is accepted then all conditions or limitations listed on the Certificate should be transferred to design documentation including architectural drawings, specifications, and fire engineering reports (FER). www.vba.vic.gov.au Page 2 of 6

COMPLIANCE PATHWAYS The BCA contains several pathways to compliance, either D-t-S or a Performance Solution or a combination of the two. In either case the building design must satisfy the relevant Performance Requirements. In relation to fire safety of external walls, the principal Performance Requirement is CP2. However a number of other Performance Requirements may need to be considered depending on the material used, its location on the external wall, the extent of coverage on the wall, whether there are openings in the wall, its location in relation to exits and potential impact on fire brigade intervention. Given the occurrences at the Lacrosse apartment fire, where the fire threatened to enter the building on numerous floor levels, the failure of the early warning system and the challenge to the fire services, Performance Requirements CP1, CP3, CP4, CP7, CP8 and CP9 may apply and Performance Requirements from other Sections of the BCA may also need to be considered. DEEMED-TO-SATISFY (D-T-S) A number of requirements apply to an external wall in Type A or B construction including: Fire- resistance level (FRL) (Specification C1.1 Tables 3 and 4) Non-combustible elements (Specification C1.1 Clause 3.1(b) and 4.1(b) Fire hazard properties of linings, materials or assemblies (Specification C1.10) IS IT A WALL OR ATTACHMENT? WALLS The BCA contains a definition of external wall which is defined as an outer wall of a building which is not a common wall. The BCA does not define wall. A review of dictionary definitions of wall and external wall, and of various provisions and definitions of the BCA leads the VBA to conclude that a reference to an external wall in the context of the BCA is a reference to the entire wall system which separates the interior air space of the building with the outside air space including any componentry or elements necessary for the external wall to achieve the requirements for structural performance, weather tightness, thermal performance, non-combustibility and required FRL if required by the type of construction, and any other functionality required under the BCA. A simple test to determine whether a material or product is a component of an external wall or an attachment is to determine whether the wall remains fully compliant with all requirements of the BCA if the material or product is removed. If the external wall remains fully compliant, then the material or product is likely to be an attachment. If the external wall is no longer fully compliant or fully functions as an external wall, then the material or product is a component of the external wall. Clause C1.1 Clause C1.1 specifies the type of construction required for classes of buildings in relation to the rise in storeys. Type A construction is required for Class 2, 3 and 9 buildings with a rise in storeys of 3 or more and Class 5, 6, 7 and 8 buildings with a rise in storeys of 4 or more. Type B construction is required for Class 2, 3 and 9 buildings with a rise in storeys of 2 and Class 5, 6, 7 and 8 buildings with a rise in storeys of 3. Clause C1.5 provides a conditional concession to allow Type C construction in a Class 2 or 3 building with a rise in storeys of 2 and a Class 9c building. Clauses 3.1(b) and 4.1(b) of Specification C1.1 In accordance with Clauses 3.1(b) and 4.1(b) of Specification C1.1, external walls are required to be non-combustible for Type A and B construction. In Type A or B construction this means that all componentry of the wall system must be noncombustible. This view is supported by the definition of noncombustible which states that applied to construction or part of a building, constructed wholly of materials that are not deemed combustible. This means that for external wall construction in www.vba.vic.gov.au Page 3 of 6

Type A or B construction, the outer cladding must be deemed to be non-combustible in accordance with AS1530.1 or, under Clause C1.12, may be used where a non-combustible material is required 1. It is noted that Clause C1.12 provides for bonded laminated materials where (i) (ii) (iii) (iv) each laminate is non-combustible; and each adhesive layer does not exceed 1 mm in thickness; and the total thickness of the adhesive layers does not exceed 2 mm; and the Spread-of-Flame Index and the Smoke-Developed Index of the laminated material as a whole does not exceed 0 and 3 respectively. In accordance with C1.12, all laminates of a bonded laminated material including ACP must be non-combustible within the meaning of the BCA. Therefore, under the D-t-S provisions of the BCA, ACPs with a polyethylene based core (including with mineral fibre content) or any other bonded laminated material with a laminate that is combustible cannot be used as the cladding or any other component of an external wall system in Type A or B construction unless supported by an appropriately formulated Performance Solution. ATTACHMENTS TO WALLS Clause C1.10 Clause C1.10 is principally applied to assess the fire hazard properties for internal linings, materials and assemblies, however Clause C1.10(c) provides a list of exempt materials allowed for use as an attachment to an external element of a building under Specification C1.1 Clause 2.4. In Victoria, Clause C1.10(c)(xiv) any other material that does not significantly increase the 1 A concession to Clauses 3.1(b) and 4.1(b) of Specification C1.1 is provided by Clause 3.10 or Clause 4.3 of Specification C1.1 or Clause C1.5. hazards of fire has recently been removed as exempt from 15 December 2015. The use of any other material that does not significantly increase the hazards of fire must now be justified through an appropriately formulated Performance Solution. Clause 2.4 of Specification C1.1 Clause 2.4 of Specification C1.1 allows combustible materials that meet certain fire hazard properties to be conditionally used as an attachment to the outer element of a building with a required FRL. Attachments include a finish or lining to a wall or roof or other attachments, such as signs, sunscreens, blinds or awnings. A lining should not be mistaken for a cladding. Combustible attachments such as a lining to an external wall are subject to conditions. An attachment such as a lining can only be used on an external wall, including a lightweight panel wall that is already compliant with all relevant parts of the BCA. A non-loadbearing wall that is greater than 3m from a fire-source feature needs to achieve a FRL of -/-/-. The definition of FRL in the BCA states -/-/- means there is no requirement for an FRL. The BCA does not provide any concessions that allow combustible attachments to be installed on an external wall not having a required FRL. Where a combustible lining or other attachment is fixed to an external wall that is non-combustible and having the required FRL, unless exempt under Clause C1.10, it must meet the fire hazard properties of Specification C1.10 and specifically, a lining must attain a Group number of 1, 2 or 3 in accordance with Clause 4 and Table 3, Other areas. Attachments other than a lining must comply with Clause 7 and Table 4 and achieve a Spread of Flame Index not greater than 9 and a Smoke Developed Index not greater than 8 if the Spread of Flame Index is more than 5. As a condition of compliance, sub-clauses 2.4(a)(ii) and (iii) of Specification C1.1 also requires an assessment of a design to ensure that the lining or www.vba.vic.gov.au Page 4 of 6

other attachment is not located near or directly above a required exit so as to make the exit unusable in a fire and it does not otherwise constitute an undue risk of fire spread via the facade of the building. Sub-Clause 2.4(b) also requires that an attachment must not impair the required FRL of the building element it is attached to. Many of the buildings audited had canopies/verandahs over the main entrance. Most of these canopies were designed as attachments and were commonly completely lined with ACP. There was no evidence in the entire audit to demonstrate that consideration had been given to sub-clauses 2.4(a)(ii) and (iii) or Sub-Clause 2.4(b). These conditions are not supported by established standards and are likely to be difficult to evaluate without suitable analysis. If it is not understood how a particular ACP or other combustible material could constitute an undue risk of fire spread via the façade, it would be appropriate to obtain the opinion of a person with the necessary expertise such as a registered fire safety engineer. The same would apply in determining how near a particular ACP could be to a required exit to ensure the exit is usable in a fire. SUMMARY OF D-T-S: A combustible material must not be used as a cladding (within the meaning of this document) or any other component of an external wall in Type A or B construction. In accordance with Specification C1.1 Clause 2.4, a combustible material may be used as an attachment to an external building element with a required FRL if o The combustible attachment achieves the required fire hazard properties under Specification C1.10 o The combustible attachment is not located near or directly above a required exit so as to make the exit unusable in a fire. o The combustible attachment does not constitute an undue risk of fire spread via the façade of the building. o The combustible attachment of a facing or finish must not impair the required FRL of the part of the building to which it is attached. PERFORMANCE SOLUTIONS Cases of fires involving external facades have provided some very useful observations about fire behavior involving combustible facades. Some of the key observations are that a façade fire has the potential to enter a building at multiple levels and threaten life safety unless mitigating techniques are utilised. Other contributing risk factors identified are the configuration and alignment of the material on the facade. Vertical alignment, re-entrant corners, channels in the facade, openings in the facade and areas of potential ignition source such as balconies and service areas, including rubbish skip collection points, should all be considered in any risk analysis 2. FIRE TESTS It is not appropriate to make simple assumptions about the fire properties of any combustible material. Many ACP and other combustible materials have been subjected to extensive fire testing other than to AS1530.1, including other prescribed BCA referenced fire testing standards and other international fire tests. As no polyethylene based ACP core is non-combustible within the meaning of the BCA, where it is proposed to use an ACP as a component of an external wall required to be non-combustible, it must be treated as a Performance Solution. Relevant test results for the specific product must be presented for analysis by a registered fire safety engineer to determine its likely behavior in a fire for the proposed use and therefore enable proper analysis of the design for compliance with relevant Performance Requirement/s of the BCA. On 30 March 2016 2 More detailed information can be found in the research paper Final Report Fire Hazards of Exterior Wall Assemblies Containing Combustible Components published by the Fire Protection Research Foundation. www.vba.vic.gov.au Page 5 of 6

Standards Australia published AS 5113 Fire propagation testing and classification of external walls of buildings. The work to develop this standard is in recognition of the need for an improved method of assessing combustible external walls in Australia. While this Standard is not yet adopted in the BCA, the VBA encourages proponents of wall systems that do not comply with the D-t-S provisions of the BCA to test combustible wall systems to this Standard. AS 5113 is a full scale facade test and has the ability to assess a complete façade system performance including the impact of the fixing methods, cut and exposed edges, thermal expansion of metals leading to delamination etc. Data from this testing will provide a registered fire safety engineer a greater level of understanding of the fire behaviour of the entire system when preparing an FER in support of a Performance Solution than other currently BCA referenced fire tests. The material properties of a combustible material, determined from small scale testing, are rarely sufficient to determine if a particular product can be used in an external wall as a Performance Solution. Considering the challenges and complexities a facade fire can present to occupants and fire services, it is also considered that a qualitative analysis is not appropriate. In accordance with the International Fire Engineering Guidelines, a quantitative analysis should be undertaken for a Performance Solution which is of a more complex nature such as the use of a combustible material as a component of, or attachment to, an external wall. It is also important that if a specific product, model and method of fixing have been assessed in a FER, the design team must ensure that the particular product and method of fixing is consistent in all documentation and specifications. It has been noted that some specifications nominate a specific brand but not the exact model and often include the words or similar. A brand only nomination is not adequate when a fire safety engineer has incorporated a specific material s properties into a design. A number of ACP suppliers/distributors have several models marketed under the same brand name. These are commonly identified due to the proportion of mineral fibre embedded within a polyethylene core, PE (or solely polyethylene) A2 and FR being common nomenclatures. The manufacturers/suppliers of ACP products and other combustible products may have specific fixing methods that may vary according to the type of construction required, i.e. Type A, B or C. If a specific fixing type has been assessed under a FER, or is required by the manufacturer/supplier, this fixing type must also be transferred to any approved construction drawings and specifications. The specification should also ensure that the builder must seek approval from the fire safety engineer and relevant building surveyor if the builder proposes to use an ACP product and/or model differing from that specified in the FER and other approved documentation. If you have a technical enquiry please email: technicalenquiry@vba.vic.gov.au or phone 1300 815 127 Victorian Building Authority 733 Bourke Street Docklands VIC 3008 The VBA acknowledges the contribution made by other State and Territory jurisdictions, the Fire Protection Association Australia, Society of Fire Safety-Engineers Australia and CSIRO in the development of this Industry Alert. www.vba.vic.gov.au Page 6 of 6