SATURATED SURFACE-DRY SPECIFIC GRAVITY AND ABSORPTION OF AGGREGATES

Similar documents
DryWeight BulkVolume

SPECIFIC GRAVITY OF COARSE AGGREGATE AASHTO T 85

SIEVE ANALYSIS OF FINE AND COARSE AGGREGATES

THEORETICAL MAXIMUM SPECIFIC GRAVITY OF BITUMINOUS MIXTURES

PART I SIEVE ANALYSIS OF MATERIAL RETAINED ON THE 425 M (NO. 40) SIEVE

METHOD A10 (a) THE DETERMINATION OF THE IN-PLACE DRY DENSITY OF SOIL OR GRAVEL BY THE SAND REPLACEMENT METHOD

Standard Test Procedures Manual

Florida Method of Test for TESTING OF GROUND TIRE RUBBER Designation: FM 5-559

Apr 17, 2000 LAB MANUAL

FIELD SAMPLING AND TESTING MANUAL TESTING PROCEDURES FOR ALL TESTS

Field Density Determination of Asphalt Concrete by the Coring Method

SIEVE ANALYSIS OF FINE AND COARSE AGGREGATES FOP FOR AASHTO T 27 (11)

EXPERIMENT NO.1. : Vicat s apparatus, plunger

METHOD A7 THE DETERMINATION OF THE MAXIMUM DRY DENSITY AND OPTIMUM MOISTURE CONTENT OF GRAVEL, SOIL AND SAND

NOTE: FOR PROJECTS REQUIRING CONTRACTOR MIX DESIGN, THE DESIGN PROCEDURES ARE SPECIFIED IN THE SPECIAL PROVISIONS OF THE CONTRACT.

Standard Test Procedures Manual

PERMEABILITY TEST. To determine the coefficient of permeability of a soil using constant head method.

SOIL-LIME TESTING. Test Procedure for. TxDOT Designation: Tex-121-E 1. SCOPE 2. APPARATUS 3. MATERIALS TXDOT DESIGNATION: TEX-121-E

Elektra. Elektra. training. manual. manual. Coffee Grinder. Coffee Grinder SHARING THE PASSION

CONSTANT HEAD AND FALLING HEAD PERMEABILITY TEST

Apr 17, 2000 LAB MANUAL PARTICLE SIZE ANALYSIS OF SOILS AASHTO Designation T 88 (Mn/DOT Modified)

DETERMINING DENSITY OF COMPACTED BITUMINOUS MIXTURES

In-situ Density Determination by Sand Replacement Method

METHOD OF TEST FOR DETERMINATION OF PERMEABILITY OF GRANULAR SOILS

Standard Test 1. SCOPE Description of Test

SEE HOW TO MAKE LIME PLASTER WHY USE LIME? PATTI STOUTER, BUILD SIMPLE INC. FEBRUARY 2013

A REVIEW OF AGGREGATE AND ASPHALT MIXTURE SPECIFIC GRAVITY MEASUREMENTS AND THEIR IMPACTS ON ASPHALT MIX DESIGN PROPERTIES AND MIX ACCEPTANCE

Standard Test Procedures Manual

GRADATION OF AGGREGATE FOR CONCRETE BLOCK

Specific volume and absorption properties

Chapter 8 Design of Concrete Mixes

COMPACTING BITUMINOUS SPECIMENS USING THE SUPERPAVE GYRATORY COMPACTOR (SGC)

S.3.6. BULK DENSITY AND TAPPED DENSITY OF POWDERS. Final text for addition to The International Pharmacopoeia

LABORATORY DETERMINATION OF CALIFORNIA BEARING RATIO

The University of Toledo Soil Mechanics Laboratory

DETERMINING ASPHALT CONTENT FROM ASPHALT PAVING MIXTURES BY THE IGNITION METHOD

METHOD OF TEST FOR SAMPLING AND TESTING CRUMB RUBBER MODIFIER

POWDER PROPERTIES LABORATORY

METHOD OF TEST FOR UNIT WEIGHT OF FRESH CONCRETE

SURFACE TREATMENT BOND TEST

Determination of a Chemical Formula

Standard Operating Procedure for Cleaning Nylon Filters Used for the Collection of PM 2. 5 Material

Knowledge Domain: Plumbing Unit: Leaking Skill: Epoxy

Standard Test Procedures Manual

HAMBURG WHEEL-TRACKING TEST

Espresso/Cappuccino/Single Serve Coffee Maker. Instruction Manual HY YEAR LIMITED WARRANTY

COMPACTING SPECIMENS USING THE TEXAS GYRATORY COMPACTOR (TGC) PART I COMPACTING SPECIMENS USING THE TGC. Test Procedure for

K2 STONE NATURAL VENEER

BELLMAN CXE-25/27 INSTRUCTIONS

Treatment of a surface or structure to resist the passage of water in the absence of hydrostatic pressure. presence of hydrostatic pressure.

CORROSION ENGINEERING RESIN-BASED POLYMER CONCRETES AND GROUTS

EXPERIMENT 10 CONSTANT HEAD METHOD

PHYSICAL AND PLASTICITY CHARACTERISTICS

SECTION 623 CONCRETE BONDING COMPOUND, EPOXY MORTAR AND EPOXY POLYMER CONCRETE OVERLAY SECTION CONCRETE BONDING COMPOUND.

:: ARTIFICIAL SAND :: Zone One Sand : Zone Two Sand :

STANDARD OPERATING PROCEDURES

OLD BRICK ORIGINALS KILN-FIRED THIN BRICK VENEER Installation Guide. GeneralShale.com

CSUS Department of Chemistry Experiment 8 Chem.1A

THE DETERMINATION OF THE MAXIMUM DRY DENSITY AND OPTIMUM MOISTURE CONTENT OF MATERIALS USING THE VIBRATORY HAMMER COMPACTION

Sieve Analysis of Aggregates

Chemistry 112 Laboratory Experiment 6: The Reaction of Aluminum and Zinc with Hydrochloric Acid

8.9 - Flash Column Chromatography Guide

ATT-72/94, SALT SIEVE ANALYSIS. This method describes the procedure for determining the gradation of salt.

SEPARATION OF A MIXTURE OF SUBSTANCES LAB

Mold Preventing I nterior System

SECTION 55 PIPE FOR STORM DRAINS AND CULVERTS (FAA D-701)

Lab 1 Concrete Proportioning, Mixing, and Testing

Hands-On Labs SM-1 Lab Manual

Reaction of Magnesium with Hydrochloric Acid (Gas Laws) Chemicals Needed:

Site sampling and testing of concrete

BENTLEY ELEMENTS COLLECTION LVT

CAST IRON THE BASICS. Heatline - Cast Iron Radiators SMOOTH FLAT FILE TO REMOVE ANY SWARF. ONE TIME. ASSEMBLY. JOINTS SHOULD BE TIGHTENED.

Minor Cracks in Horizontal Surfaces

Adhesive Recommendation for Altro Flooring. Porous (absorbent) subfloors (most wood subfloors and some concrete)

Flocking of textiles. Flocked shirt 13. flocking drying cleaning. adhesive. application. creation

ISOLATION OF CAFFEINE FROM TEA

DIY CABINET REFACING INSTALLATION GUIDE

6 QUALITY CONTROL PROCEDURES

LAYING BLOCK AND BRICK

AN EXPERIMENT IN ALCHEMY: COPPER TO SILVER TO GOLD 2005, 2000, 1996 by David A. Katz. All rights reserved

The Molar Mass of a Gas

Standard Test Methods for Density and Specific Gravity (Relative Density) of Plastics by Displacement 1

Soil Testing Soil index properties 24. Cone Penetrometer Method BS 1377, , EN DD ENV Semi-Automatic Cone Penetrometer

Mixtures. reflect. How is seawater different from pure water? How is it different from rocky soil?

SYNTHESIS AND ANALYSIS OF A COORDINATION COMPOUND OF COPPER

Lay blocks with mortar

Strength and Workability Characteristics of Concrete by Using Different Super Plasticizers

8 plumbing. plumbing PulteGroup, Inc. All Rights Reserved.

VERIFYING CALIBRATION OF WEIGHING DEVICES USED FOR LABORATORY TESTING

Make Your Own Hypertufa Container. Supplies. The recipe. by Michelle Gervais

Electric Meat Grinder

Determination of Insoluble Solids in Pretreated Biomass March 2008 Material

Selection, Use, and Care of Brushes

MOISTURE (Karl Fischer, Buffered)

The Analytical Balance

Instruction Manual. Image of SP-3015 & SP Important Safeguards. Automatic Dispensing Hot Water Pot with Reboil Function

Construction. 3-part thixotropic epoxy patching mortar. Product Description. Tests

GUIDELINES FOR TESTING FRESH SELF-COMPACTING CONCRETE

BLADE REPAIR INSTRUCTION BOOKLET

Commonwealth of Pennsylvania PA Test Method No. 632 Department of Transportation October Pages LABORATORY TESTING SECTION. Method of Test for

Transcription:

Test Procedure for SATURATED SURFACE-DRY SPECIFIC GRAVITY AND ABSORPTION OF TxDOT Designation: Tex-403-A Effective Date: August 1999 1. SCOPE 1.1 This method determines the saturated surface-dry (SSD) specific gravity and water absorption of natural mineral aggregates used in Portland cement concrete. 1.2 The values given in parentheses (if provided) are not standard and may not be exact mathematical conversions. Use each system of units separately. Combining values from the two systems may result in nonconformance with the standard. 2. DEFINITIONS 2.1 Bulk volume (of an aggregate) the volume of water displaced by aggregate in a SSD condition, including both the volume of the impermeable portion of the aggregate particles and the volume of the permeable voids in the particles. 2.2 Saturated surface-dry the condition of the aggregate when all permeable pores of each particle are completely saturated with water and its surface has no free moisture. 2.3 Saturated surface-dry specific gravity the ratio of the mass of SSD aggregate to the mass of an equal volume of water. 2.4 Absorption moisture content the moisture content at saturated surface-dry condition in contrast to its oven-dry condition. 3. REPORT FORMS 3.1 Moisture Properties and Unit Weight of Concrete Aggregates 4. APPARATUS 4.1 Glass jar, 2 L (0.5 gal.), and pycnometer cap. 4.2 Balance, Class G2 in accordance with Tex-901-K, minimum capacity of 4000 g (8.75 lb.), with the capability to weigh by hanging the sample under the balance (optional). CONSTRUCTION DIVISION 1 8 LAST REVIEWED: SEPTEMBER 2014

4.3 Sample container, wire basket of 3.35 mm (No. 6) or finer mesh, or a bucket of approximately equal breadth and height, with a capacity of 4 7 L (1 1-3/4 gal.) for 38 mm (1-1/2 in.) nominal maximum size or smaller, and a larger container as needed for testing larger maximum size aggregate. The container should be constructed to prevent trapping air when the container is submerged (optional). 4.4 Water tank, into which the sample and container are placed for complete immersion while suspended below the balance, equipped with an overflow outlet for maintaining a constant water level (optional). 4.5 Suspended apparatus, wire suspending the container should be the smallest practical size to minimize any possible effects of a variable immersed length (optional). 4.6 Drying oven, maintained at 110 5 C (230 9 F). 4.7 Funnel, wide-mouthed. 4.8 Set of standard U.S. sieves, meeting requirements of Tex-907-K, in the following sizes: 4.75 mm (No. 4) 600 m (No. 30). 4.9 Pans, 305 mm (12 in.) in diameter. 4.10 Small trowel, with a rectangular blade. 4.11 Syringe or rubber bulb. 4.12 Quartering machine, sample splitter, or quartering cloth. 4.13 Lint-free cloth or towel. 4.14 Metal Cone, with: inside top diameter of 40 3 mm (1.5 0.125 in.) inside bottom diameter of 90 3 mm (3.5 0.125 in.) height of 75 3 mm (3 0.125 in.), and minimum thickness of 0.8 mm (0.0313 in.) 4.15 Tamper, face diameter of 25 3 mm (1 0.125 in.) and mass of 340 15 g. 5. MATERIALS 5.1 Clear, potable water. 5.2 Fine Carborundum cloth. CONSTRUCTION DIVISION 2 8 LAST REVIEWED: SEPTEMBER 2014

6. PROCEDURES 6.1 Calibrating Pycnometer: 6.1.1 Select a 2 L (0.5 gal.) mason jar with good threads on the neck. 6.1.2 Be sure the rim is free of cracks or chips. 6.1.3 If the rim is rough, place a piece of fine grain Carborundum cloth on a smooth, solid, level surface; hold the jar in a vertical position with the top against the Carborundum cloth; and smooth and true the rim by rotating the jar over the cloth. 6.1.4 Apply force and continue the grinding action until the rim of the jar appears to be perfectly smooth. 6.1.5 Clean the jar and fill with clean tap water at 23 2 C (73 3 F). 6.1.6 With the gasket seated smoothly in place to prevent leaking, screw the metal pycnometer cap snugly on the jar. 6.1.7 Use the rubber siphon bulb to fill with water, leaving a rounded bead of water on top of the cap. 6.1.8 Dry the outside of the cap and jar with a towel. 6.1.9 Determine the mass of the pycnometer filled with water to the nearest 0.5 g and record the mass as Y under Section 7. 6.1.10 Obtain and record the temperature of the water. Note 1 This test procedure calls for a specific temperature range for the water used during both the calibration of the pycnometer and during the actual performance of the test. If for any reason this range cannot be met, take special care to ensure that the temperature of the water used to calibrate the pycnometer is within 2 C ( 3 F) of the temperature of the water used to perform the test. Note 2 Use identification marks and match marks on the cap and jar to produce constant volume measurements. 6.2 Determining SSD Specific Gravity of Fine Aggregate: 6.2.1 Secure a representative field sample of the fine aggregate passing a 4.75 (No. 4) sieve in accordance with Tex-400-A. Use a sample splitter or quartering cloth to reduce the sample to a laboratory test size of approximately 3000 g. 6.2.2 Place the test sample into a pan and cover with water. Allow to soak for a minimum of 24 hours. Avoid using metal pans, which react with aggregates. Note 3 For field determination of absorption only, use Tex-409-A, Part II. 6.2.3 Decant the water and spread the material in a thin layer on a clean, smooth surface such as a metal-topped workbench. CONSTRUCTION DIVISION 3 8 LAST REVIEWED: SEPTEMBER 2014

6.2.4 Allow the sample to air dry without applying artificial heat. 6.2.5 Use a small trowel to stir and mix the sample frequently so that the particles on top will not become drier than SSD. 6.2.6 Hold the cone firmly on a smooth nonabsorbent surface with the larger diameter down. 6.2.7 Place the partially dried fine aggregate loosely in the cone. 6.2.8 Fill it to slightly overflowing by holding the mold with a cupped hand. 6.2.9 Lightly tamp the fine aggregate into the mold with 25 light drops of the tamper. Start each drop at about 5 mm (0.2 in.) above the top surface of the fine aggregate. 6.2.10 Allow the tamper to fall freely and distribute the drops over the entire surface. 6.2.11 Remove loose sand from around the base and lift the cone vertically. 6.2.11.1 If surface moisture is still present, the fine aggregates will retain the molded shape. 6.2.11.2 Some angular fine aggregate or material with high proportion of fines may not slump in the cone test upon reaching a surface-dry condition. This may be the case if fines become airborne upon dropping a handful of sand from the cone test 100 150 mm (4 6 in.) onto a surface. For these materials, consider the SSD condition as the point that one side of the fine aggregate slumps slightly upon removing the mold. 6.2.12 Transfer the SSD test sample to the balance and weigh out approximately 1200 g immediately to prevent loss of moisture. 6.2.13 Record the mass to the nearest 0.5 g as X under Section 7. 6.2.14 Place the SSD sample into the pycnometer jar about one quarter full of water by means of the wide-mouthed funnel, taking care not to lose any of the material. 6.2.15 Rinse the funnel over the jar with water so that any clinging particles will wash into the jar. 6.2.16 Fill the jar with water to within about 12.5 mm (0.5 in.) of the rim, screw the cap on the jar, and then fill completely with water. 6.2.17 Stop the hole in the cap with a finger and roll the pycnometer to free all entrapped air. When the sample contains large pieces of coarse aggregate, roll the pycnometer gently to prevent breaking the glass jar. Raise and lower the jar in such a manner that the material will flow from one end of the jar to the other while it is being rolled. 6.2.18 When a quantity of air bubbles has accumulated, refill the pycnometer, washing out the air, and roll again. 6.2.19 Repeat the rolling and shaking of the jar until all of the air has been removed. To facilitate the removal of the air, use a water aspirator, but take care to prevent siphoning out any of the finer particles. CONSTRUCTION DIVISION 4 8 LAST REVIEWED: SEPTEMBER 2014

6.2.20 Dry the outside of the pycnometer thoroughly. 6.2.21 Use a syringe or rubber bulb to fill the jar carefully with water, leaving a rounded bead of water on top of the cap. 6.2.22 Determine the mass of the pycnometer and contents to the nearest 0.5 g. 6.2.23 Record the mass, Z, and the temperature of the water as shown under Section 7. 6.2.24 Remove the pycnometer cap and pour the sample into a clean, tared pan. 6.2.25 Rinse the cap, jar, and hands thoroughly over the pan to collect all of the material. 6.2.26 Allow the material to settle and the water to become clear, then decant or siphon the water from the sample. 6.2.27 Dry the aggregate to constant mass in an oven, then cool to room temperature and weigh. 6.2.28 Record the net oven-dry mass of the sample to the nearest 0.5 g as X 1 under Section 7. 6.2.29 Keep the excess saturated surface-dry material sealed in the airtight container for check tests. When making check determinations, use an odd number of grams, approximately the same mass as for the first test, for mass of surface-dry aggregate. 6.3 Coarse Aggregate: 6.3.1 Secure a representative field sample in accordance with Tex-400-A and reduce to laboratory test size of approximately 1500 g with a sample splitter or quartering cloth. 6.3.2 Place the sample in a pan and cover with water. Allow to soak for a minimum of 24 hours. Avoid using metal pans, which react with aggregates. Note 4 For field determination of absorption only, use Tex-409-A, Part II. 6.3.3 Drain the water from the sample and transfer a portion of the material to a lint-free cloth or towel. 6.3.4 Roll the material in the cloth and rub with dry ends until all surface moisture has been removed. The material may also air dry at room temperature to SSD. Do not dry past the SSD condition. 6.3.5 When SSD is reached, place the surface-dried material into a small container and cover with a lid. 6.3.6 Continue this operation until entire sample is at SSD. 6.3.7 Transfer the SSD test sample to the balance and weigh immediately to prevent loss of moisture. 6.3.8 Place sample into pycnometer jar about one quarter full of water using the wide-mouthed funnel, taking care not to lose any of the material. CONSTRUCTION DIVISION 5 8 LAST REVIEWED: SEPTEMBER 2014

6.3.9 Rinse the funnel so that any clinging particles wash into the jar. 6.3.10 Fill the jar with water to within about 12.5 mm (0.5 in.) of the rim, screw the cap on the jar, and then fill completely with water. 6.3.11 Stop the hole in the cap with finger and roll the pycnometer to free all entrapped air. If the sample contains large pieces of coarse aggregate, roll the pycnometer gently to prevent breaking the glass jar. Raise and lower the jar so the material will flow from one end of the jar to the other while being rolled. 6.3.12 When a quantity of air bubbles has accumulated, refill the pycnometer, washing out the air, and roll again. Repeat the rolling and shaking of the jar until all of the air has been removed. To facilitate the removal of the air, a water aspirator may be used, but take care to prevent siphoning out any of the finer particles. 6.3.13 Dry the outside of the pycnometer thoroughly. 6.3.14 Carefully fill the jar with water using a syringe or rubber bulb, leaving a rounded bead of water on the top of the cap. 6.3.15 Determine the mass of the pycnometer and contents to the nearest 0.5 g. 6.3.16 Record the mass, Z, and the temperature of the water as shown in Section 7. 6.3.17 Remove pycnometer cap and pour sample into a clean, tared pan. 6.3.18 Rinse cap, jar, and hands thoroughly over the pan to collect all of the material. 6.3.19 Allow material to settle and water to become clear, then decant or siphon the water from the sample. 6.3.20 Dry the aggregate to constant mass in an oven, then cool to room temperature and weigh. 6.3.21 Record net oven-dry mass of sample to the nearest 0.5 g as X 1 under Section 7. 6.3.22 Keep the excess saturated surface-dry material sealed in the airtight container for check tests. When making check determinations, use an odd number of grams, approximately the same mass as for the first test, for mass of surface-dry aggregate. 6.4 Mineral Filler: 6.4.1 Determine the specific gravity of the mineral filler in accordance with Tex-202-F, using material that passes the 600 m (No. 30) sieve. 6.5 Aggregate Coarser than 25 mm (1 in.) Nominal Maximum Size (Optional): Note 5 Nominal Maximum Size is the largest sieve size listed in the applicable specification, upon which any material is permitted to be retained. 6.5.1 Secure a representative field sample in accordance with Tex-400-A. Reduce to laboratory test size with a sample splitter or quartering cloth according to Table 1. CONSTRUCTION DIVISION 6 8 LAST REVIEWED: SEPTEMBER 2014

6.5.2 Reject all material passing a 4.75 mm (No. 4) sieve by dry sieving and thoroughly washing to remove dust or other coatings from the surface. 6.5.3 Place the sample in a pan and cover with water. Allow to soak for a minimum of 24 hours. Avoid using metal pans, which react with aggregates. Note 6 For field determination of absorption only, use Tex-409-A, Part II. 6.5.4 Remove the test sample from the water and roll it in a large absorbent cloth until all visible films of water are removed. 6.5.4.1 Wipe the larger particles individually. Use a moving stream of air to assist in the drying operation. Take care to avoid evaporation of water from aggregate pores during the operation of surface drying. 6.5.4.2 Determine the mass of the test sample in the saturated surface-dry condition. 6.5.4.3 Record this and all subsequent masses to the nearest 1 g or 0.1 percent of the sample mass, whichever is greater. 6.5.5 After determining the mass, immediately place the saturated-surface-dry test sample in the sample container and determine the mass in water at 23.0 ± 1.7 C (73.4 ± 3 F), having a density of 997 ± 2 kg/m 3. Take care to remove all entrapped air before determining the mass by shaking the container while immersed. 6.5.6 Record the weight of submerged sample as S under Section 7. 6.5.7 Dry the test sample to constant mass at a temperature of 110 ± 5 C (230 ± 9 F). Cool in air at room temperature 1 3 hours, or until the aggregate has cooled to a temperature that is comfortable to handle (approximately 50 C). Determine the mass and record as X 1 under Section 7. Nominal Maximum Size, mm (in.) Table 1 Test Sample Size Minimum Mass of Test Sample, kg (lb.) 25.0 (1) 4 (8.8) 37.5 (1-1/2) 5 (11) 50 (2) 8 (18) 63 (2-1/2) 12 (26) 75 (3) 18 (40) 7. CALCULATIONS 7.1 Calculate SSD specific gravity (G): G X / ( X Y Z ) or X / ( X S ) -OR- CONSTRUCTION DIVISION 7 8 LAST REVIEWED: SEPTEMBER 2014

Bulk specific gravity (G BULK ) GBULK X1 / ( X Y Z ) or X1 / ( X S ) Where: S = submerged sample weight, in basket X = mass of SSD sample, kg (lb.) X 1 = the net oven-dry mass of the sample, kg (lb.) Y = mass of calibrated pycnometer filled with water, kg (lb.) Z = mass of pycnometer containing SSD sample and water at 23 2 C (73 3 F) to fill, kg (lb.) 7.2 For a combination of aggregates, calculate G for each (G 1, G 2, G i, etc.) and then calculate the average SSD specific gravity of the combination: G / [( W / G ) ( W / G ) ( W / G ) etc. ] 100 1 1 2 2 Where: W 1 = percentage of i th material based on the total mass of the combination. 7.3 Calculate absorption of the aggregate: A ( X X ) / X 1 1 7.4 Calculate average percent absorption of combined materials: A [( A W ) ( A W ) etc. ] / 1 1 2 2 100 i i 8. REPORT 8.1 Report specific gravity results to the nearest 0.01 and absorption results to the nearest 0.1%. CONSTRUCTION DIVISION 8 8 LAST REVIEWED: SEPTEMBER 2014