FOOD ESTABLISHMENT REQUIREMENTS

Similar documents
General Information on Starting a Restaurant Business in Alabama

New or Remodeled Food Service Establishment Checklist**

Chapter 5 Water, Plumbing, and Waste

Montgomery County Health Department Mobile Food Guidelines. Definitions

Florida s Cottage Food Industry and Beyond

TARRANT COUNTY PUBLIC HEALTH DEPARTMENT fax FOOD ESTABLISHMENT REVIEW APPLICATION

FORT WORTH CODE COMPLIANCE DEPARTMENT CONSUMER HEALTH DIVISION PLAN REVIEW FOR FOOD ESTABLISHMENTS & PERMITTING REQUIREMENTS

Article 11 Laundry and Dry Cleaning

SOUTH CAROLINA. Downloaded January 2011

STARTING A FOOD BUSINESS GUIDE

Guidelines for New or Remodeled Food and Drink Establishments

SINKS / DISHMACHINES. Food Preparation Sink

PLAN REVIEW AND APPROVAL FOR FOOD ESTABLISHMENTS PLUMBING REQUIREMENTS FOR FOOD ESTABLISHMENT PREMISES

MISSISSIPPI. Downloaded January 2011

FOOD ESTABLISHMENT PERMIT APPLICATION FOR NEW, REMODEL OR CHANGE OF OWNERSHIP

GUIDELINE FOR THE DESIGN, CONSTRUCTION AND RECONSTRUCTION OF A FOOD HANDLING ESTABLISHMENT

FLOOR MATERIALS FOR RETAIL FOOD FACILITIES

The following guide to food establishment design is

Subpart 1. Installation. All plumbing systems must be. installed and tested according to this chapter and chapter 4715,

APPLICATION FOR FITOUT OR PLAN ASSESSMENT UNDER THE FOOD ACT 2001

SANITATION AND PEST CONTROL INSPECTION REPORT INSPECTOR: BUSINESS NAME:

SOUTH CAROLINA DEPARTMENT OF AGRICULTURE FOOD SAFETY DIVISION GUIDELINES FOR FOOD PROCESSORS (REVISED)

CALIFORNIA PLAN CHECK GUIDE FOR RETAIL FOOD FACILITIES

A GUIDE TO OPENING A FOOD PREMISES

BUCKS COUNTY DEPARTMENT OF HEALTH PLAN REVIEW APPLICATION FOR FOOD FACILITIES

Plumbing Installations. A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

Hygiene Standards for all Food Businesses

Chapter 8 Water and Sewage Systems

Minimum Housing and Health Standards

3. It is recommended that the water supply into the facility can be obtained from two (2) separate water lines if possible.

Note: Not all sections may be applicable to every establishment. Contact above Reg. Agency if you have questions.

Plumbing Code in Commercial Kitchens

Guideline on Emergency Action Plans for Food Establishments: Sewage Backup

Plumbing Installations A homeowner guide to the City of Winnipeg plumbing requirements for a single-family dwelling

Food Service Operation/Retail Food Establishment Plan Review Application

CODE OF HYGIENIC PRACTICE FOR DRIED FRUITS (CAC/RCP )

MARICOPA COUNTY ENVIRONMENTAL HEALTH CODE

Brian Coppock, Regional Compliance Officer. Office of Statewide Health Planning and Development Facilities Development Division

Food Protection Program 2 North Meridian Street Indianapolis, IN

STARTING A NEW FOOD BUSINESS? GUIDELINES FOR OPENING A CLASS 3 FOOD BUSINESS

Plumbing Code in Commercial Kitchens. NH BOA May 9, 2012

ARTICLE SANITATION CHAPTER RULES OF SANITATION

Sanitation Performance Standards Compliance Guide

Facility Self Evaluation Report

RHODE ISLAND. Downloaded

CLEANING AND SANITIZING

STANDARD OPERATING PROCEDURE S (SOP S) FOR HAZARDOUS ANALYSIS CRITICAL CONTROL POINT (HACCP) PLANS

TEMPORARY EVENT APPLICATION

A GUIDE TO AVA FOOD FACTORY GRADING SYSTEM

GUIDELINES FOR OPERATORS OF MOBILE FOOD BUSINESSES: DESIGN, CONSTRUCTION

RRIO Checklist. Use of checklist: Definitions: Limitations

STEPS NECESSARY FOR APPROVAL TO OPERATE A FOOD SERVICE ESTABLISHMENT

Retail Food Establishment Inspection Reports

6. Principles of effective plumbing systems

Guideline on Emergency Action Plans for Food Establishments

How To Insure Against Problems With Your Home Warranty

EMERGENCY ACTION PLAN FLOOD AND FOOD OPERATIONS

Important Information for Vendors at Temporary Events

TYPICAL FIRE SAFETY INSPECTION VIOLATIONS

Plumbing Code Sections For Commercial Food Facilities

Guidelines for Food Premises Design and Equipment

Permit Application for Mobile Food Truck

FACILITIES DESIGN ASSESSMENT AND PERMITTING QUESTIONNAIRE: (For use by all food risk categories 1-3 or higher)

CENTER FOR ENVIRONMENTAL HEALTH Emergency Response/Indoor Air Quality Program

MY HOME IN A HOUSING BLOCK A GUIDE FOR RESIDENTS

INTEGRATED PEST MANAGEMENT

CONSTRUCTION PLAN APPROVAL PROCEDURES FOR FOOD FACILITIES

Notes. Material 1. Appropriate Flammable Liquids

Candidate Study Guide for the Illinois Food Service Sanitation Manager Examinations

RULES GOVERNING THE FOOD PROTECTION AND SANITATION OF FOOD ESTABLISHMENTS

REQUIREMENTS FOR TRADE SHOWS

Restaurant/Food Service Construction Guide. Portsmouth Health Department 1 Junkins Ave Portsmouth, NH (603)

Backflow Bulletin #1

CRITICAL VIOLATION RISK FACTORS

Clay County Food Service Permit For ORGANIZING a Special EVENT

BY-LAW CONCERNING THE SANITATION AND MAINTENANCE OF DWELLING UNITS

GUIDELINES. for COTTAGE INDUSTRY INVOLVED in HOME FOOD PRODUCTION

October 5, 2015 Dear Client,

Food Safety Evaluation Checklist. Directions

Mold Response and Remediation Plan

R432. Health, Health Systems Improvement, Licensing. R Nursing Facility Construction. R Legal Authority. R Purpose.

Clean Water: Supply side potable water, not wastewater. Gray Water/Sewage: Wastewater originating from a drain (sink, toilet, urinal).

Land Use and Environmental Service Agency (Code Enforcement) NC Plumbing Code. Table of Contents

MOLD RESPONSE AND REMEDIATION PLAN

Water should be removed as soon as possible once the safety of the structure has been verified.

CONSTRUCTION GUIDEBOOK FOR WHOLESALE FOOD FACILITIES

Transcription:

FOOD ESTABLISHMENT REQUIREMENTS 1. Three-compartment sink with dual drainboards A sink with at least three compartments shall be provided for manually washing, rinsing and sanitizing equipment. And shall be provided in any establishment handling exposed food products. The three-compartment sink shall be indirectly drained, have dual, self-draining drainboards, be large enough to accommodate immersion/washing of the largest equipment and utensils, and be supplied (as must all sinks) with adequate pressure and temperature of hot and cold water. Any other sink used for culinary purposes shall also be indirectly drained. *Testing Devices A thermometer and a sanitizing solution concentration test kit shall be readily available to test the temperatures and the sanitizing solution concentration of the wash-rinse-sanitize process. A food thermometer shall also be provided in an establishment that prepares or processes potentially hazardous food products. 2. Handsink A handwashing facility shall be located to allow convenient use by employees in food preparation, food dispensing, and warewashing areas; and in, or immediately adjacent to, toilet rooms. Handwash sinks shall be used exclusively for handwashing and shall be supplied with handwashing cleanser and an approved method for drying hands, and be supplied with adequate pressure and temperature of hot and cold water. Handwashing facilities shall be installed as required by the International Plumbing Code. 3. Utility sink At least one service sink or curbed cleaning facility with a floor drain shall be provided and used for the cleaning of mops or similar wet floor cleaning tools and for the disposal of mop water or similar liquid waste. 4. Clean Room for Processing applies to any area where exposed food is handled, processed, or packaged. A. Flooring: Floors and floor coverings of all food preparation, food storage and warewashing areas and floors of all walk-in refrigerators, dressing rooms, locker rooms, toilet rooms and vestibules shall be constructed of smooth, durable materials, such as sealed concrete, terrazzo, quarry tile, ceramic tile, durable grades of vinyl, asbestos, or plastic tile, or tight fitting wood impregnated with plastic and shall be maintained in good repair. Carpeting is prohibited in preparation areas, walk-in refrigerators, warewashing areas, toilet room areas, refuse storage rooms or other areas where the floor is subject to moisture. Floor and wall junctures shall be coved and closed to no larger than 1mm. Floors subject to water flush cleaning shall be provided with properly installed trapped drains and be graded to drain. These floor and wall junctures shall be coved and sealed. B. Walls, Wall Coverings, and Ceilings Wall and Ceiling surfaces shall be smooth, light-colored, durable, easily cleanable and nonabsorbent. Except in areas used only for dry storage, concrete, porous blocks, or bricks used for indoor wall construction shall be finished and sealed to provide a smooth, nonabsorbent, easily cleanable surface. Page 1 of 5

Utility service lines and pipes may not be unnecessarily exposed. Attachments to walls and ceilings in processing areas, such as light fixtures, vent covers, fans, etc, shall be easily cleanable. 5. Restrooms Toilet facilities shall be installed and of the number required by the International Plumbing Code. They shall be conveniently located and shall be accessible to employees at all times. They shall be completely enclosed and shall have tight-fitting, self-closing solid doors, except for louvers that may be necessary for ventilation systems. Toilet rooms shall not open directly into a food processing area. This requirement can be met by (1) installing two self-closing doors between the processing area and the toilet room; or (2) having the toilet room open into another area, such as a hallway or storage area, with a distance of at least 15 feet between the door of the toilet room and the processing area. 6. Lights Light bulbs shall be shielded, coated, or otherwise shatter-resistant in areas where there is exposed food; clean equipment, utensils, and linens. Lighting, at a distance of 30 inches above the floor, shall have the following intensities: Walk in refrigeration units and dry food storage areas at least 10 foot candles. Food display areas, inside equipment such as refrigerators, warewash areas, restrooms at least 20 foot candles. Areas where employees are working with equipment such as knives, grinders, slicers, saws, or where employee safety is a factor at least 50 foot candles. 7. Equipment and Food Contact Surfaces Materials that are used in the construction of utensils and food-contact surfaces of equipment may not allow the migration of deleterious substances or impart colors, odors, or tastes to food and under normal use conditions shall be: safe; durable, corrosion-resistant, and nonabsorbent; sufficient in weight and thickness to withstand repeated warewashing; finished to have a smooth, easily cleanable surface; and resistant to pitting, chipping, crazing, scratching, scoring, distortion, and decomposition. Bare wood is prohibited in most circumstances except for cutting boards, cutting blocks, bakers tables and shipping containers of whole, uncut, raw fruits, vegetables and nuts in the shell, Multiuse food-contact surfaces shall be: smooth; free of breaks, open seams, cracks, chips, pits, and similar imperfections; free of sharp internal angles, corners, and crevices; finished to have smooth welds and joints; and accessible for cleaning and inspection by one of the following methods: Without being disassembled, by disassembling without the use of tools, or by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screw drivers, pliers, open-end wrenches and Allen wrenches that are kept near the equipment. Equipment shall be installed so that it may either be moved for ease of cleaning or shall be installed to allow at least six inches clearance between the floor and the equipment or four inches between the table and equipment, for table-mounted equipment. All tables and equipment that are not easily movable shall be spaced to allow cleaning on all sides of the equipment, spaced adjacently to adjoining equipment with a distance of not more than one millimeter, or sealed to adjoining equipment or walls. Page 2 of 5

8. Food and Equipment Storage All food, equipment and single service articles shall be stored in a clean, dry location; where it is not exposed to splash, dust, or other contamination; and at least 6 inches above the floor or on case lot handling equipment (unless the food is unpackaged). Food may not be stored: in locker rooms; in toilet rooms; in dressing rooms; in garbage rooms; in mechanical rooms; under sewer lines that are not shielded to intercept potential drips; under leaking water lines, including leaking automatic fire sprinkler heads, or under lines on which water has condensed; under open stairwells; or under other sources of contamination. 9. Ventilation Ventilation hoods shall be installed to prevent grease or condensation from collecting on walls and ceilings, and shall be designed to be easily cleanable. All rooms, including toilet rooms, shall have sufficient ventilation to keep them free of excessive heat, steam, condensation, vapors, obnoxious odors, smoke and fumes. Ventilation systems shall be installed and operated according to state and local requirements. Type I suppression hood systems are required for indoor, open flame roasting according to the Uniform Fire Code and the International Mechanical Code. Local building/fire codes would regulate the necessity for ventilation and fire suppression systems. Please check all local building/fire codes that apply to indoor, open flame roasting in your area. 10. Bulk Food Bulk food modules shall be designed with close fitting, self-closing, individual covers and a method for storing product scoops. All bins shall be easily cleanable and designed so that they can be removed individually for cleaning. If bulk food modules are used, a threecompartment sink or an approved warewashing machine shall be present for the washing of these containers. Bulk bins are required to be labeled with (1) The manufacturer s or processor s label that was provided with the food; or (2) a card, sign, or other method of notification that includes: The common name of the food, a list of ingredients in descending order of predominance by weight (if made from two or more ingredients), and nutrition labeling, except as exempted in the Federal Food, Drug, and Cosmetic Act Sec. 403(Q)(3)-(5). 11. Ice Machines Ice for consumer use shall be dispensed only by the employees with scoop, tongs or other dispensing utensils or through automatic self-service ice dispensing equipment designed so that the consumer does not come into manual contact with the bulk ice. Ice machines shall be indirectly drained. 12. Back flow Prevention There shall be no cross connection between the potable water supply and any nonpotable or questionable water supply. Plumbing systems shall be installed to preclude backflow of a solid, liquid, or gas contaminant into the water supply system at each point of use at the food establishment, including on a hose bib if a hose is attached or on a hose bib if a hose is not attached and backflow prevention is required by law. This shall be accomplished by providing an air gap Page 3 of 5

or by installing an approved backflow prevention device, both as required by the International Plumbing Code. *A spray nozzle on the end of a hose is considered a downstream valve, and a Pressure Vacuum Breaker or equivalent is required. 13. Sewage disposal system All sewage, including liquid waste, shall be disposed of by a public sewage system or by a sewage disposal system constructed, maintained and operated according to sate and local health department requirements. 14. Garbage Equipment and receptacles for refuse, recyclables, and returnables and for use with materials containing food residue shall be durable, cleanable, insect and rodent resistant, leakproof, and nonabsorbent. Containers shall also be of an adequate number to hold all the refuse that accumulates. Refuse, recyclables, and returnables shall be kept covered and shall be removed from the premises at a frequency that will minimize the development of objectionable odors and other conditions that attract or harbor insects and rodents. Outside garbage and refuse containers shall be stored on a hard, easily cleanable surface. 15. Employee Lockers If employees routinely change clothes within the establishment, rooms or areas shall be designated and used for that purpose. Lockers or other suitable facilities shall be provided and used for the orderly storage of employee s clothing and other belongings. 16. Parking Areas The walking and driving surfaces of all exterior areas of food establishments shall be surfaced with concrete, asphalt or with gravel or similar material effectively treated to facilitate maintenance and minimize dust. 17. Living Quarters No operation of a food establishment shall be conducted in any room used as living or sleeping quarters. All food processing and packaging areas shall have no doors, windows, or other entrances leading into living or sleeping quarters. Food prepared in a private home may not be used or offered for human consumption in a food establishment. 18. Laundry Laundry facilities in a food establishment shall be done in separate rooms except that such operations may be conducted in storage rooms containing only packaged food and packaged single service articles. Only linens and work clothes used in the operation shall be laundered in the laundry facilities provided on the premises. Clean and soiled work clothes and linens including articles such as wiping cloths shall be stored in a clean place and protected form contamination until used. 19. Dishwashing Machines Dishwashing machines shall be properly installed and operated as required in the Utah Food Protection Rule. Page 4 of 5

20. Water Source Drinking water shall be obtained from n approved source. Private water systems shall be constructed, maintained, and operated according to R309 101-113, Rules for Public Drinking Water Systems. 21. Plumbing Plumbing systems shall be designed, constructed, installed, and operated according to the International Plumbing Code. 22. HACCP Plans HACCP plans, Hazard Analysis and Critical Control Point, are required when smoking, curing, or reduced oxygen packaging meat. HACCP plans are also required for fish processing. The Utah Department of Agriculture and Food (UDAF) requires plan submission and approval before construction or remodeling of a food establishment. Plan submission should include a schedule of floors, walls and ceilings, a scaled layout of the floor plans of approximately ¼ inch = 1 foot, and should include information showing that the pertaining requirements mentioned above will be met. Before opening, a pre-opening inspection is required which consists of a walk-through evaluation as to whether the food establishment meets the requirements to process, package, or store food in Utah. After opening, UDAF inspects food establishments approximately twice a year. These inspections are unscheduled and unannounced. This summary is not an all-inclusive set of rules governing food establishments. For more information on requirements, an online copy of the Utah Food Protection Rule is available at www.ag.utah.gov, under food safety. Other sets of law governing food safety: Code of Federal Regulations (CFR) is available at www.access.gpo.gov/nara/cfr/index.html, Title 21 covers food and drugs. The FDA Food Code is available at www.cfsan.fda.gov, under Special Interest Areas. Please call with any questions or to contact a Compliance Officer concerning an inspection. Utah Department of Agriculture and Food, Division of Regulatory Services phone number: (801) 538-7124. Page 5 of 5