LIMITATIONS OF INFLOW COMPUTATION FROM PUMP STATION DATA A MONITORING/MODELING APPROACH

Similar documents

UDG Spring Conference Birmingham 2016

Application Note 3: TrendView Recorder Smart Logging

ENGINEERING COMPETENCY CLAIMS

PIPELINE INSPECTION UTILIZING ULTRASOUND TECHNOLOGY: ON THE ISSUE OF RESOLUTION By, M. Beller, NDT Systems & Services AG, Stutensee, Germany

The Control of ph and Oxidation Reduction Potential (ORP) in Cooling Tower Applications By Charles T. Johnson, Walchem Corporation

DIGITAL-TO-ANALOGUE AND ANALOGUE-TO-DIGITAL CONVERSION

An Introduction to. Metrics. used during. Software Development

High Precision Measurement of the Target Mass of the Daya Bay Neutrino Detectors

Content Sheet 7-1: Overview of Quality Control for Quantitative Tests

Broad Crested Weirs. I. Introduction

Chapter 3 : Reservoir models

AVOIDING THE PITFALLS OF DYNAMIC HYDRAULIC CONDITIONS WITH REAL-TIME DATA

Digital and Analog I/O

Application Note Noise Frequently Asked Questions

Monitoring & Control of Small-scale Renewable Energy Sources

Application of InfoWorks CS Software for the Hydraulic Design of HATS Stage 2 Sewage Conveyance System in Hong Kong, China

Online Infrared Flue Gas Analyzer Gasboard 3000

DATRAN RTU Data Logging

MIKE 21 FLOW MODEL HINTS AND RECOMMENDATIONS IN APPLICATIONS WITH SIGNIFICANT FLOODING AND DRYING

SURVEYING WITH GPS. GPS has become a standard surveying technique in most surveying practices

CHAPTER 3 AVI TRAVEL TIME DATA COLLECTION

CHAPTER 12 MONITORING AND CONTROL SYSTEMS

TRIMBLE ATS TOTAL STATION ADVANCED TRACKING SYSTEMS FOR HIGH-PRECISION CONSTRUCTION APPLICATIONS

Understanding the Flo-Dar Flow Measuring System

Pump Controller Type ABS PC 441 Monitoring and/or Control of Pumps and Pumping Stations

IP Sensing Water & Wastewater AMR/SCADA System

Recommended Practice for Software Acquisition

GETTING STARTED WITH LABVIEW POINT-BY-POINT VIS

Mixing Valves. ARGUS Application Note: Mixing Valves

Various Technics of Liquids and Solids Level Measurements. (Part 3)

DESCRIPTIVE STATISTICS. The purpose of statistics is to condense raw data to make it easier to answer specific questions; test hypotheses.

CATALYST Frequently Asked Questions

Wastewater Collection Practice Test #3 Page 1 of 15

Technical Manual. FAN COIL CONTROLLER COOLING or HEATING ANALOG or PWM Art A

Building Environmental Monitoring Infrastructures

PREDICTIVE AND OPERATIONAL ANALYTICS, WHAT IS IT REALLY ALL ABOUT?

Control and Remote Supervision of Sewage Pump Station. AutoLog GSM-RTU and AutoLog ControlMan Web-SCADA Service. Specification V1.

Flood and Drain Irrigation Control with a GP1 Logger

THE ENVIRONMENTAL TECHNOLOGY VERIFICATION PROGRAM

Transmitter Interface Program

Portal Software GSM-PRO Run LED displays module activity Com LED displays activity on the GSM network GSM-PRO

Key functions in the system of governance Responsibilities, interfaces and outsourcing under Solvency II

PATTERN MATCHING OF LIVE DATA TO IMPLEMENT PROACTIVE NETWORK MANAGEMENT

Peeling the Onion of Meter Accuracy Two Steps to Evaluating Flow Meter Data

Concepts of digital forensics

Seagull Intersection Layout. Island Point Road - A Case Study. Authors: John Harper, Wal Smart, Michael de Roos

A Strategy for Teaching Finite Element Analysis to Undergraduate Students

GPS Data Collection Procedures for Georeferencing Vegetation Resources Inventory and National Forest Inventory Field Sample Plots

ATL Fuel Level Sender Probes

Michael Montgomery Marketing Product Manager Rosemount Inc. Russ Evans Manager of Engineering and Design Rosemount Inc.

Tracking the Flow: Meeting the Challenge of Open- Channel Flow Measurement in Municipal Applications

Sanitary Sewer Overflows Leave Telltale Signs in Depth-Velocity Scattergraphs

Applying Pressure Independent Control Valves in H.V.A.C. Systems. A Presentation to: Orange Empire ASHRAE Santa Ana Nov. 17, 2009

Introduction To SCADA and Telemetry

Experiment (13): Flow channel

TURBOtech srl. SED-635 Digital Excitation System. Industrial Electronics Sector FEATURES

Why and How we Use Capacity Control

Current-Transformer Phase-Shift Compensation and Calibration

How to calibrate an RTD or Platinum Resistance Thermometer (PRT)

SINGLE-SUPPLY OPERATION OF OPERATIONAL AMPLIFIERS

PUMPED Nd:YAG LASER. Last Revision: August 21, 2007

Users Guide. By Dr. Don J. Wood Dr. Srinivasa Lingireddy. Featuring the Surge Wizard

Spectrum occupancy measurement and evaluation

research highlight Remote Monitoring and Control of On-Site Wastewater Treatment, Recycling, and Reuse Systems

Measuring Soil Moisture for Irrigation Water Management

BEST PRACTICES IN LEAK DETECTION AND REPAIR (LDAR) PROGRAMS. November 06, 2014 By: François Thibodeau, Eng.

AN Application Note: FCC Regulations for ISM Band Devices: MHz. FCC Regulations for ISM Band Devices: MHz

Sigma Control PC INSIDE. 97 psi 187 F R on load

Data Quality Assurance and Control Methods for Weather Observing Networks. Cindy Luttrell University of Oklahoma Oklahoma Mesonet

WATER STORAGE, TRANSPORT, AND DISTRIBUTION Multi-Dam Systems and their Operation - J.J. Cassidy MULTI-DAM SYSTEMS AND THEIR OPERATION

Cat Electronic Technician 2015A v1.0 Product Status Report 4/20/2016 2:49 PM

Fiscal Measurement Natural Gas

Measurement with Ratios

Safety Requirements Specification Guideline

NETWORK MONITORING. Network Monitoring. Product brief. NETWORK MONITORING Logger Only

FAQ s on Siemens Magmeters

1 in 30 year 1 in 75 year 1 in 100 year 1 in 100 year plus climate change (+30%) 1 in 200 year

Water Distribution System Wireless Monitoring Solutions

LAB 7 MOSFET CHARACTERISTICS AND APPLICATIONS

Sharp-Crested Weirs for Open Channel Flow Measurement, Course #506. Presented by:

Centro-Matic Automatic Lubrication Systems System Controls

Utilities Engineering Technician Trailblazer Assessment Plan ASSESSMENT PLAN. Utilities Engineering Technician

Optical Encoders. K. Craig 1. Actuators & Sensors in Mechatronics. Optical Encoders

ME Heat Transfer Laboratory. Experiment No. 7 ANALYSIS OF ENHANCED CONCENTRIC TUBE AND SHELL AND TUBE HEAT EXCHANGERS

DIALER SPECIFICATION VERBATIM MODULAR SERIES VSS

NortechCommander Software Operating Manual MAN R6

Texas Commission on Environmental Quality Page 1 Chapter Design Criteria for Domestic Wastewater Systems

CRITICAL PATH ANALYSIS AND GANTT CHARTS

Line Monitoring and Control in Subsea Networks

FIBRE-OPTICS POWER METER INSTRUCTION MANUAL

Head Loss in Pipe Flow ME 123: Mechanical Engineering Laboratory II: Fluids

Fault codes DM1. Industrial engines DC09, DC13, DC16. Marine engines DI09, DI13, DI16 INSTALLATION MANUAL. 03:10 Issue 5.0 en-gb 1

By Authority Of THE UNITED STATES OF AMERICA Legally Binding Document

Selecting RJ Bandwidth in EZJIT Plus Software

Wahl C50 Calibrator FEATURES

ABB i-bus EIB / KNX Analogue Input AE/S 4.2

User's Guide. Integrating Sound Level Datalogger. Model Introduction

Fundamental Principles of Rotary Displacement Meters

Performance ratio. Contents. Quality factor for the PV plant

Transcription:

LIMITATIONS OF INFLOW COMPUTATION FROM PUMP STATION DATA A MONITORING/MODELING APPROACH Author: Matthew Cooper AWT New Zealand limited ABSTRACT Wastewater pump stations dot the landscape of almost every wastewater reticulation network across New Zealand. Typically their design, location at key nodes within the reticulation and the presence of the data logging capabilities of modern onsite SCADA systems make them tempting locations for flow measurement via the method of inflow computation. The flow measurement information can be a critical input into network modeling, consent compliance, operational control and event trouble-shooting. However, logged data on SCADA, even if it is verified, and applying one of several different methods for inflow calculation does not always result in a data set that is accurate, that truly reflects reality at key times or is reality usable for modeling. This paper will highlight several limitations present with computing inflow data from pump status and wetwell records and will provide practical solutions to overcome them. These limitations can have a significant influence on the ease and accuracy of subsequent modeling and the use of the data for other purposes. KEYWORDS Wastewater pump station, monitoring, modeling. 1 INTRODUCTION SCADA (Supervisory Control and Data Acquisition) systems are essential tools in the successful operation and management of wastewater networks. They provide two way control, alarming and data logging capabilities. As pump stations are often located at the downstream end of wastewater catchments, and the fact they have data logging onsite, use of the SCADA logged data for determining inflow for computer modeling use is tempting for project cost reduction. However, frequently it is discovered too late that the data is not suitable for computer modeling, and that a lower model confidence is the result. This is because SCADA systems are operational tools, and as such have an emphasis on logging data for trending and not the high frequency, high precision data collection required for accurate inflow calculation. This paper will point out the most profitable method to employ before using SCADA logged data for inflow computation is to carefully examine a sample of data to ensure that it will provide sufficient accuracy at key times.

2 INFLOW CALCULATION Inflow calculation undertaken using pump station records is an inferred flow measurement method. This is because it can only be undertaken after a pump event as opposed to HVQ or V notch style open channel flow measurement that occurs on a discreet (often 5 minute) interval. As the time between pump events and the duration of the pumping is variable, the methods used for inflow computation result in inflow data that is highly averaged when compared to a discrete measurement. This fact introduces the primary assumption made in order for inflow calculation to be undertaken; the inflow rate computed is an average between pump cycles. This has the tendency of masking some of the critical inflow characteristics; most importantly for modeling, the initial response time and peak inflow value. This is demonstrated in Figure 1 below. Wetwell level Inflow Rate Time Time lag to peak Peak flow error due to averaging Time Computed from pump station data Direct flow measurement (eg HVQ) Figure 1: Representation of inflow masking characteristics Using pump status, wet well level and known wet well geometry, inflow into a pump station can be computed in a number of different yet interlinked methods. The methods are known by different names, but essentially comprise of: 1. Pump run (Qrun) The average pump discharge rate is multiplied by the pump run time then divided by the time between pump off and the previous pump off. 2. Wetwell fill (Qfill) The change in well volume is divided by the time from the same pump off to the next pump on. An average inflow during pumping can be assumed in a number of ways including simple extrapolation of the previous computed inflow brought forward or the average of the computed inflows either side of the pump cycle in question.

3 DATA LIMITATIONS 3.1 PUMP STATION CONFIGURATION Although not specifically a SCADA based data issue, pump station configuration is an essential consideration before commencing on a modeling study. In this instance, pump station configuration refers to the levels pump start and stop are set to in relation to inlet pipes (ie fully or partially submerged inlets), the number of starts per hour, the run-time of a pump in normal dry weather conditions and the ratios of inflow rate to pumping capacity. Fully or partially submerged inlets greatly increase the inflow measurement uncertainty as they introduce a variable (upstream volume) that cannot be determined easily. Some methods to overcome this is to lower the start level of the pump to below the inlet. Where this cannot be done, or regular high wetwell levels occur, filling the wetwell to maximum (often overflow) level and then pumping the wetwell down whilst recording the wetwell level and flow from a magflow meter. Alternatively (and to a higher uncertainty), an average pump rate can be used. This method will enable a level to volume table for the wetwell to be developed. The number of starts per hour influence the quality of the data (in terms of inflow averaging, time lag and peak flow errors) as it minimises the length of time over which inflow rates are averaged. Experience has shown that a minimum of four (4) starts per hour during peak periods is generally sufficient. The ratio of inflow rate to pumping capacity (hence dictating the time taken to pump down) is another uncertainty source for inflow computation. It is the inverse of the number of starts per hour, but with the same effect; long pump run-times resulting in significant inflow averaging, increased peak flow errors and increased time lag. 3.2 DATA LOGGING STRATEGY USED BY SCADA Trending is essential in SCADA systems as it reduces the volume of data being telemeted and stored whilst still maintaining the integrity of the SCADA system. The resultant dataset can be of limited use for careful study of the system operation (as with modeling). The term data logging is loose in definition as it simply infers that data is available in electronic format that can be readily manipulated using a spreadsheet or specialised time-dependant database software package without providing any specifics as to the frequency of logging, the accuracy of the instrument being logged and any calibration/correction that may be required before the data is used. Data can, and is trended in a number of ways, using almost as many methods as there are SCADA systems installed. Some common trending methods used throughout New Zealand include: 15 minute discrete data points 15 minute data points that are an average of the period over which the 15 minutes extend (may also include rate of change threshold filtering) 15 minute pulse totals from a magflow, inferring an average flow rate over that time. 30 second discrete data points of pump state or motor current (inferring pump state) Data trending has varying effects depending on the dataset being examined. Treading in wetwell level will artificially reduce the total measured volume entering the station, and hence lower the computed inflow rate. Pump state trending undermines the premise of knowing a fixed filling and pumping cycle. Use of this type of pump state data will artificially increase the computed inflow rate as the pump cycles will be shorter than reality, thereby resulting in artificially increased inflow rates. For inflow computation, pump state, wetwell level and flow through the magflow meter (if available) are required. The minimum data logging requirements for inflow computation are instantaneous (1 sec) resolution

for pump change-of-state (i.e. off-on or on-off). Typically where soft-starters are installed, the change-of-state logging will occur when full speed is reached. Wetwell level should be logged on 1 min discrete intervals (or better) with an optional additional log when a pump changes state. Finally, magflow meters can be logged using either analogue (4-20mA) or pulse outputs. If using analogue, a 10 sec resolution is a reasonable median. This resolution enables accurate discharge curves and volumes to be computed. Pulse data from magflow meters should record each instantaneous pulse, or accumulate counts on a small (say 10 sec) interval. Commonly, the data logging requirements are outside the capability of SCADA systems due simply to the volume of data being collected. 3.3 AVAILABILITY OF DATA SCADA has the primary purpose of system control and this includes alarming on events such as high motor current draw, high wetwell level, station security breech etc. As alarming takes precedence, all other communications with the base station are suspended. Often this can occur in high inflow (wet weather) conditions where multiple stations are alarming and logged data is not always transmitted and recorded. Unfortunately, it is these periods of the dataset that are most keenly examined with modeling. 3.4 SUITABILITY OF DATA Use of conductive level probes and float switches as methods of automatically starting and stopping pumps are reliable, and as such are common throughout New Zealand. However, both suffer pump start drifting as a result of maintenance frequency. Progressive fatting about the probe or float results in a variable water level at pump start. This is shown in Figure 2 below. Progressive change in pump start level Level probe maintenance Consistent stop level indicates depth sensor operating correctly Figure 2: Variable pump start level as a result of maintenance Whilst this is not a particular issue, is does become one if the distance between start and stop levels is assumed to be constant over the period for which inflow data is being computed. Derivition of data pump state from wetwell level (ie if falling, pump is on, if rising, pump is off) can be significantly erroneous. During high inflow (wet weather) conditions, it is common for wetwells to fill whilst the pump is running. This is demonstrated in Figure 4 below. Without logged pump change-of-state, pump state would need to be assumed or remain unknown.

Wet well filling Pump 2 running Figure 3: Rising wetwell level whilst pump running Data resolution is another limitation on the suitability of data collected by SCADA systems. Resolution is really only of consideration with logging analogue (4-20mA) signals, and hence has the most impact in the logging of wetwell level. Resolutions issues are easy to identify when logging the analogue (4-20mA) output of multitrodes as stepped data corresponding to the distance between conductive sensor bands on the probe is the result. This introduces wetwell volume uncertainty as the actual level of the wetwell is not accurately known, but can be extrapolated between jumps in the logged data and the indicative slope of the line. In addition to this, probes do not commonly extend to maximum surcharge height, thereby eliminating any possibility of computing inflow data during high inflow (wet weather) periods as the maximum conductive sensor bands becomes drowned out. Distance between conductive bands Figure 4: Stepped wetwell level It is common throughout the operation of SCADA systems to install wetwell level sensors, and never regularly calibrate them. Sensors fall out of calibration in two main ways, gross failure and progressive failure. In the instance of gross failure, it is easy to indentify. However, progressive failure is significantly more difficult to identify as SCADA systems log data to enable operators to view current pump station performance against performance an hour, day or week ago.

Likewise, it is common to install wetwell level sensors with no particular reference to a known survey datum. As trending only requires relative changes in the measured parameter, this installation method is adequate for SCADA data logging. However, when computing inflow, it is essential to know from the wetwell level where on the level to volume curve a logged data point is. This will ensure that the correct change of volume is computed and hence the correct inflow rate. Simple water level dips (covering a wide depth range) from a known datum point (eg lip of the wet well cover) will assist in eliminating sensor datum uncertainties whist gathering sufficient data to validate the calibration of the sensor. 4 POSSIBLE SOLUTIONS TO DATA LIMITATIONS With all the limitations to using SCADA logged data, the most profitable solution is to carefully examine a sample of historical data, preferably one that includes both dry and wet weather periods. This will ensure that the engineer or modeler is conversant with the data type, resolution and quality available, and be able to make an educated decision before-the-event if SCADA logged data will be suitable for use. A wide range of low cost, high frequency, high precision data loggers are available on the market in New Zealand, and this may provide the best solution for any data shortcomings identified. Employment of a flow monitoring contractor conversant with pump station monitoring is another option. In order to overcome extensive averaging of computed inflow, infilling it with inflow computed simply from wetwell volume change divided by time can be used to improve the dataset resolution. This is demonstrated in Figure 5 below. When employing this method during periods of extended pump run, inflow must be added to pump capacity whilst the wetwell is filling, and subtracted from pump capacity whilst the wetwell is emptying. Alternating pump cycles Infilled inflow points Figure 5: Infilling inflow

5 CONCLUSIONS Computing inflow data from pump status and wetwell level records can be inadequate at key times due to the nature of the data, operation of the station and a number of other limitations. Careful examination of SCADA data before-the-event along with a number of simple field calibration procedures can significantly reduce the inflow computation uncertainty. ACKNOWLEDGEMENTS I would like to acknowledge Peter Stephens of AWT for technical review.