Aarlogic TER-HX910-EU. Product description. Rev.9 17/03/2013

Similar documents
EZmoto V2. Product description Rev. 6 10/01/2014. EZmoto V2 Product description Rev.6 10/01/2014

Hardware Interface Description

GSMPBX version 1.3 Datasheet

LOW COST GSM MODEM. Description. Part Number

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

How To Use An Adh8012 Gsm Gprs Module With A Gsm (Gsm) Gpros (Gsp) Gpls (Geo) Gsp (Gpl) Gs

Installation Instructions. Wireless Adapter/Repeater. Introduction Rev C

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

CelluLine CGW-TS GSM Cellular Gateway. Installation and Programming Manual

M400gsm GSM Modem Datasheet

How To Write A Librao Low Voltage Differential (Lvds) Module On An Nio 6585 Fuserio (Flexrio) Power Supply (Femaleseo) And Power Supply On An Iphone Or Ip

STRATO LED Drivers 70W, Single output

IFS SP-PoE Splitter User Manual

IDD-213T User Manual. (Rev. 1.0) China Aerospace Telecommunications Limited

Waveguide Access Point WGA631. Product Guide

M68EVB908QL4 Development Board for Motorola MC68HC908QL4

Technical description MX-1 VB Edge

Telephone- and leased line modem for industrial applications TD-36

PSDC PSDC 12V/8A/8x1A Power supply for up to 8 analog cameras PTC/TOPIC.

TX OPEN RS232/485 module

Model 201 Wiegand Touchpad Reader Installation Guide

UPS PIco. to be used with. Raspberry Pi B+, A+, B, and A. HAT Compliant. Raspberry Pi is a trademark of the Raspberry Pi Foundation

LS1024B / LS2024B/ LS3024B. Solar Charge Controller USER MANUAL

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Rack mounted telephone- and leased line modem for industrial applications

SVC400P/SVC800P. 4/8 Camera Live Tracking Vehicle DVR Installation Manual. Version 1.0

TM7BDM8B expansion block - TM7 - IP67-8 DI/DO - 24V DC A - M8 connector

MANUAL PC1000R

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

PCAN-B10011S Bus Converter High-speed CAN to Truck Trailer CAN. User Manual. Document version ( )

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

FOR MORE INFORMATION or from a non-telstra phone and say pre-paid telstra.com/ppmbb visit a telstra store or partner

Rev GSM base station. Installation instructions

is then retained absolutely without interruption.

Indoor / Outdoor Antenna

Product Datasheet P MHz RF Powerharvester Receiver

Maestro Heritage. GSM GPRS Modem 850 / 900 / 1800 / 1900 USER MANUAL Rev. 03

GSM Controller BR160GM-Gate

GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G WI-FI

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI

Fiber Optic Selector Guide for Analog & Digital Data Links, Contact Closures & Multiplexers

Modular I/O System Analog and Digital Interface Modules

Original instructions Tina 3A/Aps Adaptor unit

GETTING TO KNOW YOUR TELSTRA PRE-PAID 3G USB + WI-FI

GSM Voice Auto Dialer & SMS Sender JC-999

GSM Interfacing Board

StructureScan HD Module. Installation Guide ENGLISH

Quectel M72 Development Board

Antec TruePower User's Manual


RUDAT Key Features. Mini-Circuits P.O. Box , Brooklyn, NY (718)

GETTING TO KNOW YOUR 4G USB

Model PS-4001 Power Supply User Instructions

EMOSAFE EN-100. Network Isolators for PCB assembly 1 GENERAL DESCRIPTION. Product Data Sheet ENGLISH

AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

Kvaser Mini PCI Express User s Guide

SMS GSM Alarm Messenger

TEP 200WIR Series, Watt

Voltage Regulator SPAU 341 C. Product Guide

Manual. Simrad StructureScan LSS-1 Sonar Module. English

HEOL-N103-OBD, GPS/GPRS Tracking Module with On Board Diagnostic

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

12-Volt 10-Amp Regulated Power Supply

EPGM1 HARDWIRED ZONE & PGM OUTPUT EXPANSION MODULE

MCR-VDC-UI-B-DC. Voltage Transducer for DC Voltages. INTERFACE Data Sheet _en_01. 1 Description

ACRS 2.0 User Manual 1

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Antenna Splitter ASA 1. Instruction manual

IEEE b/g/n WiFi Module. Product Specifications

Model 70A00-1. GSM Cellular Communications Center

ZC-24DO CANopen I/O Module: 24 Digital Outputs

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Strato Pi Hardware Guide

ML 1012 v.1.2 ML13,8V/1A Buffer power supply module, linear.

USER MANUAL. Model U ForeFront Alarm Card SALES OFFICE (301) TECHNICAL SUPPORT (301) An ISO-9001 Certified Company

IRIS Touch 600 Range Dialler Installation Manual. Version 1.3

PSU-U-24V/AC-6A/10/FTA-TR-MC PSAC 0624

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

telstra.com/ppmbb visit a telstra store or partner GETTING TO KNOW YOUR

Digital input modules

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

SOLARCARE SERIES PRODUCT AND APPLICATION GUIDE

How To Use A Power Supply Unit (Upu)

Disturbance Recoder SPCR 8C27. Product Guide

FM4100 USER MANUAL V1.4

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

Alarm over IP. IRIS Touch Home Installation Manual. Version 1.0 ENGLISH. Now certified and compliant with EN50131, EN50136 Security Grade 4 ATS6

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

USB Plus+ RFID Reader Setup Guide

TX GSM SMS Auto-dial Alarm System. Installation and User Manual

2014 GSM SHIELD COMPATIBLE WITH ARDUINO GSM SHIELD USING SIMCOMM (SIM900A)

EGSTON Standard E2xFxWx 12W

TP32MTT.03 TP32MTT [ GB ] Probes for soil thermal profile measurement

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Power Supplies 3. SDN-P DIN Rail Series

Temperature & Humidity SMS Alert Controller

Broadband Telecommunications Drop Amplifier

Technical data. General specifications. Indicators/operating means. 30 Hz Multiplex operation 30 Hz / n, n = number of sensors, n 5

GPRS M-Bus Master. User Manual. An Economical and Practical Solution For Remote Automactic M-Bus Smart Meter Reading by GPRS In The Worldwide!

ADACSNET USB Control Module

Transcription:

Aarlogic TER-HX910-EU Product description Rev.9 17/03/2013

Contents 1 Overview... 3 2 Hardware Interface Description... 3 2.1 Main features of the TER-HX910-EU... 3 2.2 Hardware block diagram... 4 3 Interface description... 5 3.1 Molex 4 pin connector Power connector... 5 3.1.1 Power Supply... 5 3.1.2 Supply voltage requirements... 6 3.2 USB CONNECTOR... 6 3.3 SMA CONNECTOR... 6 3.4 SIM DRAWER... 6 3.5 RS-232 Interface... 7 3.6 AUX Interface... 8 3.7 Status LED... 9 3.7.1 Red LED... 9 3.7.2 Green LED... 9 4 OPTION: Watchdog operation... 10 5 Mechanical Characteristics... 11 5.1 General mechanical description... 11 5.2 Environmental Requirements... 11 5.3 Protection Class... 11 5.4 RoHS compliance... 11 6 SAFETY RECOMMENDATIONS... 12 7 Certifications... 13 2

1 Overview The TER-HX910-EU is a complete Cellular Terminal solution for GSM/UMTS applications. Based on Telit HE910-EUD module. 2 Hardware Interface Description 2.1 Main features of the TER-HX910-EU Feature Implementation Incorporates Telit HE910-EUD module The Telit module handles all GSM/UMTS processing with PYTHON script OPTION: PIC16F1824 Microcontroller Frequency bands Power supply ADC and GPIO inputs For Modem ON/OFF and Watchdog GSM: 850/900/1800/1900MHz UMTS/HSPA+: 850/900/2100MHz Single supply voltage 6V DC to 55V DC connector 4 pin micro-fit 3mm Two outputs optocouplers open collector drive 100ma Two inputs optocouplers, 0-55v One ADC 10 bit, 0-55V connector 6 pin micro-fit 3mm Communication Modem Full RS232, connector D-Type 9pin (DB-9) Modem USB, Connector USB Type B High retention Antenna GSM/UMTS via SMA connector 3

2.2 Hardware block diagram 4

3 Interface description 3.1 Molex 4 pin connector Power connector 3.1.1 Power Supply The power supply of the TER-HX910-EU Terminal requires a single voltage source of POWER 6V-55V capable of providing a peak during an active transmission. The TER-HX910-EU Terminal is protected against supply voltage reversal. An internal fuse 1.1A 60V ensures an electrical safety according to EN60950-1. This fuse is not removable. A fast blow fuse of 0.8A is necessary for 24V power supply system (for vehicles). The power supply recommended being any safety approved power supply certified IEC 60950-1 or EN 60950-1 or UL 60950-1 with limited output current up to 2A. The type of the receptacle assembled on the TER-HX910-EU Terminal is 4 pin Micro Mate-N-LOK 3mm (0.11 (0.11 inch) from MOLEX. Signal name Use 1 POWER Input Power supply range 6-55V 2 Power Enable Control pin to turn ON/OFF Terminal power. When putting this pin to voltage >6V the unit will be turn OFF. When putting this pin OPEN or GND the unit will be turn ON. 3 GND Ground 4 Not connected Pin assignment of the power plug including power supply and Power Enable. 5

3.1.2 Supply voltage requirements The DC power supply must be connected to the POWER input: Input voltage range 6-55V DC Nominal Voltage 12V DC Power Supply current rating: max. 2A @12V Power Supply ripple: max. 120mV Input current in idle mode: 20mA @ 12V Input average current in communication mode: 100mA @ 12V 3.2 USB CONNECTOR The USB CONNECTOR of the TER-HX910-EU Terminal is USB TYPE B, This USB TYPE B CONNECTOR on the TER-HX910-EU is a High retention connector. It will need 15 Newton to disconnect the USB CONNECTOR. 3.3 SMA CONNECTOR The TER-HX910-EU Terminal uses SMA CONNECTOR for ANTENNA. For CELLULAR ANTTENA use the 5 band ANTENNA with 2.5dB gain. 3.4 SIM DRAWER Please insert the SIM card on the following direction into the SIM push-push. 6

3.5 RS-232 Interface The serial interface of the TER-HX910-EU is intended for the communication between the GSM/UMTS module and the host application. This RS-232 interface is a data and control interface for transmitting data. It accepts, AT commands and provides multiplexed channels. EMC immunity complies with the vehicular environment requirements according to EN 301 489-7. The user interface of the TER-HX910-EU is accessible from a Data Terminal Equipment DTE connected to the RS232 interface and it is managed by AT commands according to the GSM/UMTS specification. The supported commands are listed in the AT Commands Reference Guide. Connector type on the terminal is: RS-232 through D-Type 9-pin female Baud rate from 300 to 230,400 bit/s Short circuit (to Ground) protection on all outputs. Input voltage range: -12V to +12V 7

3.6 AUX Interface The AUX interface provides via Male 6-pole plug connector, the following options: 2 digital inputs optocouplers, input 0-55vdc. 2 outputs optocouplers, drive up to 100ma, external diode needed when driving a relay. 1 ADC (10 bit) input 0-55v. 1 Ground pin. 8

3.7 Status LED 3.7.1 Red LED The Red LED is connected to GPIO1, OFF by default. Red LED status Device Status permanently on a call is active fast interrupt sequence (period 0,5s, Ton 1s) slow interrupt sequence (period 0,3s, Ton 3s) permanently off Net search / Not registered Registered full service device off The LED can use for Network status or controlled by the user. To activate GSM status Red LED "AT#GPIO=1,0,2;#SLED=2,1,1" Red LED ON: "AT#GPIO=1,1,1" Red LED OFF: "AT#GPIO=1,0,1" 3.7.2 Green LED The Green LED is connected to GPIO7, ON by default (at power up). Green LED status permanently ON permanently OFF Device Status Device active device off Green LED control: Green LED ON: "AT#GPIO=7,1,1" (Default) Green LED OFF: "AT#GPIO=7,0,1" 9

4 OPTION: Watchdog operation The TER-HX910-EU has internal Watchdog option. If the modem was turns OFF, the watchdog will start the modem each 30 min. PYTHON script Watchdog: 1. New terminal will be shipped with the Watchdog disable. Watchdog starts working, only when the Modem`s GPIO8 changes first time to HIGH and then LOW. Each time terminal will turn OFF and ON, Watchdog will be disable. 2. Standard operation of the PYTHON script, each 2min the PYTHON script will change GPIO8 HIGH for 1 second or more and then back to LOW. 3. If the PYTHON script is not changing the GPIO8 every 2min, the Watchdog will restart the internal power supply, which will reboot the terminal. 4. To start the Watchdog operation: "AT#GPIO=8,0,1;#GPIO=8,1,1" 10

5 Mechanical Characteristics 5.1 General mechanical description Weight Dimensions (max) L x W x H 180g (6.35oz) 0.4 lb 83mm x 64mm x 34mm 3.26inch x 2.51inch x 1.33inch Case material Aluminum 5.2 Environmental Requirements Operating temperature range -20 C to +55 C -4 F to 131 F -30 C to +70 C -22 F to 158 F Humidity 5% - 85% The module is fully functional (*) in all the temperature range and it fully meets the ETSI specifications. The module is fully functional (*) in all the temperature range. Temperatures outside of the range 20 C to +55 C (- 4 F to 131 F) might slightly deviate (*)Functional: the module is able to make and receive data calls and SMS. 5.3 Protection Class IP40 Avoid exposing the Terminal to liquid or moisture. 5.4 RoHS compliance All hardware components are fully compliant with the EU RoHS and WEEE Directives. 11

6 SAFETY RECOMMENDATIONS READ CAREFULLY 1. The unit does not provide protection from lightning and surge. For outdoor installation use outdoor nonmetallic case safety approved according UL 50. Additionally you should provide protection from lightning and over voltage according National code. 2. Be sure the use of this product is allowed in the country and in the environment required. The use of this product may be dangerous and has to be avoided in the following areas: Where it can interfere with other electronic devices in environments such as hospitals, airports, aircrafts, etc. Where there is risk of explosion such as gasoline stations, oil refineries, etc. It is responsibility of the user to enforce the country regulation and the specific environment regulation. Do not disassemble the product; any mark of tampering will compromise the warranty validity. We recommend following the instructions of the hardware user guides for a correct wiring of the product. The product has to be supplied with a stabilized voltage source and the wiring has to be conforming to the security and fire prevention regulations. The product has to be handled with care, avoiding any contact with the pins because electrostatic discharges may damage the product itself. Same cautions have to be taken for the SIM, checking carefully the instruction for its use. Do not insert or remove the SIM when the product is in power saving mode. The system integrator is responsible of the functioning of the final product; therefore, care has to be given to the external components of the unit, as well as of any project or installation issue, because the risk of disturbing the GSM network or external devices or having impact on the security. Should there be any doubt, please refer to the technical documentation and the regulations in force. Every unit has to be equipped with a proper antenna with specific characteristics. The antenna has to be installed with care in order to avoid any interference with other electronic devices and has to guarantee a minimum distance from the body (20 cm/8 ). In case this requirement cannot be satisfied, the system integrator should assess the final product against the SAR regulation. The European Community provides some Directives for the electronic equipment introduced on the market. All the relevant information available on the European Community website: http://europa.eu.int/comm/enterprise/rtte/dir99-5.htm The text of the Directive 99/05 regarding telecommunication equipment is available, while the applicable Directives (Low Voltage and EMC) are available at: http://europa.eu.int/comm/enterprise/electr equipment/index en.htm 12

7 Certifications Name: Industrial GSM/UMTS Communication unit Model: TER-HX910-EU Reference standard(s): Radio Numbe Market Standard Procedure 1 Europe EN 301 511 V9.0.2 Spurious Emissions testing EMC Numbe Marke Standard Procedure 2 Europe EN 301 489-7 V1.2.1 partial testing and report 3 USA 47 CFR part 15:06 sb.b Verification Safety Numbe Market Standard 4 Europe EN 60950-1:06 DoC Procedure 13