Electric actuators type EA25-250

Similar documents
Electric Rotary Actuator - On/Off or programmable control actuator

Actuator for modulating control AME 435

Hydraulic Control Solutions

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

ABB i-bus KNX Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

HERZ-Thermal Actuators

Digital inductive conductivity transmitter

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Automation System TROVIS 6400 TROVIS 6493 Compact Controller

Rotary actuator for 2 and 3-way (control) ball valves Torque 5 Nm Nominal voltage AC V Control: Open/close or 3-point Auxiliary switch

Know-how makes the difference. Electrical Actuators

How To Drive A Compact Serie 1

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

Technical data. General specifications. Signal voltage V DC Signal duration. 1 s Input 2. Signal voltage. 1 s Analog output.

Ball valve C 16 valve ball completely moulded in place, extremely low clearance volume, high k v value

Air damper actuators

Combi switchbox with integrated 3/2 way pilot valve

REGULINE 600VA / 1000VA REGULATOR USER MANUAL

Smoke exhaust systems

Series 6000 Torque measured metal bellow coupling

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

How To Use A Flowmeter

Butterfly Valves PN 6/10/16 for flanged connection

WE-350 Series ¼ Turn Electric Actuator

How To Control A Power Supply With A Mini Transmitter And Switch (Power Supply)

48 SERIES Relay interface modules 10 A

Digital input modules

Current valve. for AC 24 V pulse/pause control of electrical loads up to 30 kw

ABB i-bus KNX SA/S Switch Actuators Product Manual

Thermal-Magnetic Circuit Breaker M1-..

Series 7500 Torque Sensor

Analogue Input, 4-fold, MDRC AE/S 4.1, GH Q R0001

MONITORING RELAYS. w VOLTAGE MONITORING RELAY UR5U1011. w SCHRACK-INFO. w TECHNICAL DATA

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)

N20xxA, N34xxA NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR FLOATING AND 2-POSITION CONTROL

Switch Actuator, 8-fold, 10 A, MDRC AT/S , GH Q R0111

ABB i-bus KNX Switch Actuator, x-fold, 16/20 A, MDRC SA/S x , 2CDG 110 1xx R0011

Telefon (+45) Telefax (+45) Installation and operating manual

Control- and feedback head for integrated mounting on Robolux valves Type 2036

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Reference V, 50 Hz A V,60 Hz V, 50/60 Hz A V, 50/60 Hz V, 50 Hz A V, 60 Hz

RDJ10RF/SET. Wireless room temperature controller with 24-hour time switch and LCD. Programmable, for heating systems

Phone: Fax: Web: info@clrwtr.com

Differential Pressure Sensors for air and non-corrosive gases, with calibration certificate

Assisted lift operated 2/2-way solenoid valves Type EV250B

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

Electronic Control Devices The European Product Catalogue 2007

Electrically operated valves Series M-05, 3/2-, 5/2- and 5/3-way G1/8 650 and 750 Nl/min (0.661 and Cv)

E-STOP relays, safety gate monitors

3753 en /b VE/B - VE/RG Va V riable speed drives

LG Air Conditioning Multi F(DX) Fault Codes Sheet. Multi Split Units

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Power Thyristor TS3 (SP) 3ph. Installation Guide

Product and functional description

ACS-30-EU-EMDR-10-MOD

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

Siemens AG 2011 SINAMICS V60. The perfect solution for basic servo applications. Brochure May 2011 SINAMICS. Answers for industry.

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

VAV compact controller KNX / PL-Link

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

TECHNICAL DATASHEET Incremental Encoder RI 58-H

IP40 or IP64 (EN 60529) Protection class housing. IP50 (IP65 optional) (EN 60529) Minimum length of mountig

2013 Wireless Video Intercom INSTALLATION GUIDE

13 SERIES. Electronic step relays A

0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.8 U N /0.5 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N 0.2 U N /0.1 U N

Daker DK 1, 2, 3 kva. Manuel d installation Installation manual. Part. LE05334AC-07/13-01 GF

POINTS POSITION INDICATOR PPI4

Quick running actuator

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-G2...

Points Position Indicator (PPI1) for Points Motors with Common Ground

PHOENIX CONTACT Features

LENORD. +BAUER... automates motion. PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with limited space

3/2-way Solenoid Valve, direct-acting, NC or NO

LED - Indicator Panels

Electronic overload relay EF19 and EF45

VAV compact controller KNX / PL-Link

SYSTEM 45. C R H Electronics Design

Series description: Wilo-Drain TC 40

ABB i-bus KNX Fan Coil Controller FC/S 1.1

Your Advantages For safety application up to PL e / Cat. 4 e.g. SIL 3 Manual or automatic start * see variants. Applications.

Duct Humidity Transmitter

Frequency Converter Fv

MILLENIUM INSTALLATION MANUAL NTR 735 A. Simple Automation Control Module (MAS)

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Product and Applications Description. Application Programs. Example of Operation. GAMMA instabus Technical Product-Information.

T5000 T000 LCD Digital Fan Coil Thermostat

ELR: ABB range of front panel residual current relays Protection device according to IEC/EN Annex M

Heating, air-conditioning, cooling

ABB i-bus KNX Switch Actuator, x-fold, 16 A, MDRC SA/S x , 2CDG1101xxR0011

ABB i-bus EIB Shutter Actuators JA/S , JA/S , JA/S , JA/S M, JA/S M, JA/S

T-05-S2. Rotary drive without spring return. Technical data sheet. Description. Technical data. Actuators

E-STOP relays, safety gate monitors

TYPE 65UV CEX Integrated Flame Scanner with Internal Flame Relay and Analog Output

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

Transcription:

Electric actuators type EA25-250 Small & Light Product description The actuators type EA25, EA45, EA120 and EA250 are not only excellently equipped, they also feature very high peak torques ranging from 25 Nm to 250 Nm. Therefore they are able to automate a wide range of valves. Function Electric actuators are used to operate valves with a rotating angle from 90 to 180. The actuators can be installed on any common valves with interface according to ISO 5211. Accessories allow using them not only as an on/off actuator but also in continuous operation. Applications Chemical Process Industry Water Treatment Refrigeration Benefits/Features Position feedback via relais (OPEN/CLOSE/MIDDLE) Heating element to prevent condensation Optical position indicator with LED status monitoring Third position between "OPEN" and "CLOSE" optional Relay output for "ready to operate" 7-segment error display Integrated emergency manual override with magnetic lock Robust PP-GF housing with very good chemical resistance Long service life due to robust design and superior electronics Flexible configuration thanks to modular concept Numerous monitoring and control options Easy handling Can be used anywhere thanks to universal power supply and standard interfaces 01.2016, GF Piping Systems 1

Technical data The standard version of the EA25/45/120/250 actuator consists of the following elements: Nr. Description 1 Shaft for emergency manual override hand crank 2 Power supply with cover at 230V version 3 Digital position detection 4 Control for OPEN/CLOSE/MIDDLE 5 DC motor 6 Optical position indicator 7 Light tube for LED status feedback 8 7-segment error display 9 Position feedback via relays for OPEN/CLOSE/MIDDLE 10 Heating element (temperature threshold regulator) 11 Buttons for end position adjustment 12 Signal output "ready-to-operate" 13 Connection options for DIN plugs or cable glands Spezification Combinations EA25 2-way ball valve type 546 to DN50 3-way ball valve type 543 up to DN50 EA45 2-way ball valve type 546 DN65 Butterfly valve types 567 and 578, types 038 and 039 up to DN65 EA120 2-way ball valve type 546 DN80/DN100 Butterfly valve types 567 and 578, types 038 and 039 DN80-DN200 EA250 Butterfly valve types 567 and 578, types 038 and 039 DN250/300 Rated voltage AC, 50/60 Hz AC/DC, 50/60 Hz Rated voltage tolerance ± 15% Protection class IP 65 (IP67) 1) per EN 60529 Contamination level 2 according to EN 61010-1 Overload protection Current/time-dependent (resetting) Overvoltage category II Ambient temperature -10 C to +50 C Allowable humidity Max. 90 % relative humidity, non-condensing Housing material PP-GF for very good chemical resistance 1) When used with cable glands and vertical installation. 01.2016, GF Piping Systems 2

Rated output EA25 EA45 EA120 EA250 AC: 35 VA at AC/DC: 40 VA at AC: 55 VA at AC/DC: 60 VA at AC: 50 VA at AC/DC: 55 VA at AC: 60 VA at AC/DC: 65 VA at Rated torque Mdn. (peak) 10 (25) Nm 20 (45) Nm 60 (120) Nm 100 (250) Nm Duty cycle 100% 50 % 50 % 35 % Cycle time s/90 at Mdn. 5 s 6s 15 s 20 s Connection F05 F05 F07 F07 Tested cycles (at 20 C and Mdn.) 250 000 100 000 100 000 75 000 Weight 2.1 kg 2.2 kg 3.6 kg 5.0 kg Actuating angle Max. 355, set to 90 Options Electrical ball valves Type 179-184 Type 179 184 ball valves are based on the type 546 ball valve and the EA25 (DN10 DN50), EA45 (DN65) or EA120 (DN80 DN100) actuator. The 179 184 series is designed for applications with special process requirements. Actuator hand-operated Dimensions Materials Standards Type 179 EA25/45/120 Type 546 DN10 DN100 PVC-U, PVC-C, ABS ISO/DIN Type 180 EA25/45/120 Type 546 DN10 DN100 PP ISO/DIN Type 181 EA25/45/120 Type 546 DN10 DN100 PVDF ISO/DIN Type 182 EA25/45/120 Type 546 DN10 DN100 PVC-U, PVC-C ASTM/ANSI Type 183 EA25/45/120 Type 546 DN10 DN100 PVC-U BS Type 184 EA25/45/120 Type 546 DN10 DN100 PVC-U JIS Type 167-170 Type 167 170 ball valves are based on the type 543 ball valve and the EA25 actuator. Actuator hand-operated Dimensions Materials Standards Type 167 EA25 Type 543 horizontal DN10 DN50 PVC-U, ABS ISO/DIN, ASTM/ANSI, JIS Type 168 EA25 Type 543 horizontal DN10 DN50 PP ISO/DIN Type 170 EA25 Type 543 vertical DN10 DN50 PVC-U ISO/DIN, JIS 01.2016, GF Piping Systems 3

Butterfly valves, Type 145-147 The type 145 butterfly valve is intended for wafer style installation and is adaptable to a variety of applications. With the optional positioner, its functional options range from a simple open/close valve to a precise flow control device. The type 146/147 butterfly valve is intended for lug type or wafer style installation and is adaptable to a variety of applications. With the optional positioner, its functional options range from a simple open/close valve to a precise flow control device. Butterfly valve, Actuator, Butterfly valve, hand-operated Dimensions Materials Standards Type 145 EA45/120/250 Type 567 DN50 DN300 All All standards Type 146 EA45/120/250 Type 578 DN50 DN300 All ISO/DIN Type 147 EA45/120/250 Type 578 DN50 DN300 All ASTM/ANSI Dimensions EA L1 L2 L3 L4 L5 L6 L7 L8 L9 H1 EA25 150 83 108 64 122 16 49 33 33 167 189 EA45 150 83 108 64 122 16 49 33 33 167 189 EA120 150 83 108 64 122 16 49 33 33 190 212 EA250 150 83 108 64 122 16 49 33 33 200 221 H2 01.2016, GF Piping Systems 4

Connection diagram for standard version Actuator activation Feedback signals Optical position indicator The position indicator shows the valve position. The valve positions can be read on the fitted cover. When the cover is fitted, the following image can be seen (Example ball valve): Image of position indicator in valve position 1 2-Way 3-Way horizontal (L) 3-Way vertical (L) Valve function D B A B A C C Actuating angle 0-90 0-90 0-180 Valve position 1 A B (OPEN) See image A C (Flow right side, outlet to the front) See image Valve position 2 C D (CLOSE) B C (Flow left side, outlet to the front) B C (Flow left side, bottom outlet) See image A C (Flow right side, bottom outlet) By teaching in a Middle position different possibilities can be achieved depending on the valve and the application. For example: 2-way ball valve: Middle position describes a position, limiting the 100% flow for instance only half. 3-way ball valve: Middle position describes a position of the ball in which both passages are slightly opened. 3-way ball valve: Middle position describes a position of the ball which closes both passages. 01.2016, GF Piping Systems 5

Ball valve and ball-type Function of the middle position 3-way horizontal (L-ball) CLOSE (on both sides no flow) 3-way horizontal (L-ball) Mixing (both passages slightly opened) 3-way vertikal (L-ball) Actuating angle 0 180 0-90 0-180 Position 1 Position 2 Position 3 A C (OPEN right) B C (OPEN left) 90 B D (CLOSE) 180 A C (OPEN right) A/C B/C (partly opened) 45 B C (OPEN left) 90 CLOSE (on both sides no flow) B (-C) (OPEN left) (C-) D (CLOSE) 90 A (-C) (OPEN right) 180 (Function of the middle position as Mixing with the 3-way ball valve vertical is only possible with the T-ball) LED status feedback The LED status feedback shows the valve positions and the current status of the actuator. The following table shows the colour assignment of the LED: Color Red Green White Flashes white Flashes yellow Flashes blue Green/yellow Turquoise Meaning OPEN CLOSED MIDDLE Actuator moves Error Adjustment mode Setpoint value reached (at positioner) Adjustment run / operation of colour inversion If the plant standard requires an inversion of the colour assignment, the customer can adjust this afterwards. 01.2016, GF Piping Systems 6