GAS COOLING SYSTEMS FOR STEAM REFORMING PLANTS

Similar documents
GAS COOLING SYSTEMS FOR STEAM REFORMING PLANTS

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

BorsodChem MCHZ, Czech Republic. 6,000 Nm 3 /h HTCR Topsøe Hydrogen Plant A Case Story: 18 Months from Engineering to Operation

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

WATER WALL BOILER FOR AIR AND OXYGEN FIRED CLAUS SULPHUR RECOVERY UNITS

NAWTEC CONCEPTS AND EXPERIENCES FOR HIGHER PLANT EFFICIENCY WITH MODERN ADVANCED BOILER AND INCINERATION TECHNOLOGY

Efficiency on a large scale CFB Steam Boilers

Originators of the Flexible Water Tube design

Heat Exchanger Thin Film Foul Release Applications Corrosion Resistant Protective Coatings Grit Blast Surface Prep of Tubular Equipment

High Flux Steam Reforming

I. STEAM GENERATION, BOILER TYPES

The soot and scale problems

North American Stainless

5.2. Vaporizers - Types and Usage

Latest developments in ammonia production technology

TEMA DESIGNATIONS OF HEAT EXCHANGERS REMOVABLE BUNDLE EXCHANGERS NON REMOVABLE BUNDLE EXCHANGERS SOURCE:

INTEC Engineering GmbH Heating Solutions for the Marine Industry

R&D on Oil-Burning, Environment-Friendly, High-Efficiency Boiler

Desuperheater Online Program Sizing Guidance

Steam Generator Boilers Compact Steam Boilers. Rapid Start-Up Safe in Operation

Heat Exchangers in Boilers

How To Power A Power Plant With Waste Heat

Presentation Outline. Background

HEAT RECOVERY OPTIONS FOR DRYERS AND OXIDIZERS

Condensing Boiler Efficiency

1. A belt pulley is 3 ft. in diameter and rotates at 250 rpm. The belt which is 5 ins. wide makes an angle of contact of 190 over the pulley.

North American Stainless

Coil-Wound Heat Exchangers

ASME Packaged Indirect Fired Water Heater

QUADRANT SR- Thermal Oxidizer Process Design & Environmental Control Benefits for the Sand Coating Industries

Chapter 5 - Aircraft Welding

HYBRID WAY EAF OFF GAS HEAT RECOVERY -ECORECS- MASANARI YAMAZAKI*1, YASUHIRO SATO*2, RYUTARO SEKI*3

VAD Variable Area Desuperheaters

Heat-Pipe Heat Exchanger

Pressure vessel basics for all engineers

Haldor Topsøe Catalysing Your Business

Hydrogen Production via Steam Reforming with CO 2 Capture

VAD. Variable Area Desuperheaters

System Solutions for Boiler Air Preheating

Overview of Waste Heat Recovery for Power and Heat

Aluminium Plate-Fin Heat Exchangers

Seawater corrosion resistant piping systems for large diameters up to 100 / 2.5 metres O.D.

Torino Nord. Cogeneration Plant. The gas turbine. The steam generator. The Torino Nord cogeneration plant produces electricity and heat for district

Process Heater Burners, Flare Systems, Thermal Oxidizers and Catalyst Systems. Combustion Technology

DIRECT STEAM INJECTION HOT WATER SYSTEMS FOR JACKETED HEATING

POLYCITY. Technical measures and experiences at a 6 MW cogeneration plant with wood chip furnace POLYCITY

جامعة البلقاء التطبيقية

Why and How we Use Capacity Control

Syngas Furnace Tubeskin Temperature Measurement

Improved Modern Control Station for High Pressure Bypass System in Thermal Power Plant

ABOUT US PAUL SPENCE CHIEF EXECUTIVE OFFICER

HOW TO SELECT A LOW VOLUME (L.V ) BOILER

Performance of the Boiler and To Improving the Boiler Efficiency Using Cfd Modeling

Water-Tube Package Boilers Reliable and Economical Steam Production

TARIFF CODE and updates standard

Hybrid Modeling and Control of a Power Plant using State Flow Technique with Application

TUBE-TO-TUBESHEET JOINTS: THE MANY CHOICES ABSTRACT KEYWORDS. Seal welding, tube-to-tubesheet welds, heat exchanger, mock-up, tube expansion

Boiler Calculations. Helsinki University of Technology Department of Mechanical Engineering. Sebastian Teir, Antto Kulla

FLASH TANK ECONOMIZER PRODUCT GUIDE

North American Stainless

Practical Examples of Heat Regenerative System at Steelmaking Works

From solid fuels to substitute natural gas (SNG) using TREMP

UOP Career Development. Career development program for mechanical and civil engineers

Gas-Fired, Residential Storage Type Water Heaters

CENTRIFUGAL CASTING.

STEAM HEATING SYSTEM TROUBLESHOOTING GUIDE

Selecting TEMA Type Heat Exchangers

1 DESCRIPTION OF THE APPLIANCE

Concepts in Syngas Manufacture

Hot Water Boilers and Controls Why Condensing Boilers are Different. Presented Oct. 14, 2008 Long Island Chapter, ASHRAE

INSTRUCTION MANUAL. Boil-Out TABLE OF CONTENTS SAFETY WARNINGS 2-3 RESPONSIBILITY 3 INTRODUCTION 3 PRE-BOIL OUT PROCEDURES 3-5 BOIL OUT PROCESS 5-9

No. Name Description Main input Data Main Output Data. cooling duty, process in/out temperature, inlet air temperature

CURRENT EXPERIENCE IN TYPICAL PROBLEMS AND FAILURES WITH BOILER PIPING COMPONENTS AND SUPPORTS

Bosch Commercial and Industrial Heating High efficiency steam boilers (175kg/h to 55,000kg/h)

GENERAL PROPERTIES //////////////////////////////////////////////////////

imagine SOLAR AIR CONDITIONING MADE EASY

ATI 2205 ATI Technical Data Sheet. Duplex Stainless Steel GENERAL PROPERTIES. (UNS S31803 and S32205)

TABLE OF CONTENT

Indirect fired heaters

5. State the function of pulveriser. The pulverisers are the equipments which are used to powdered coal.

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

RELIABLE AND EFFICIENT STEAM GENERATION SYSTEMS FOR MODERN UTILITY SERVICE

Petroleum Refinery Hydrogen Production Unit: Exergy and Production Cost Evaluation

912 MW Supercritical Boiler for the next Coal Fired Plant Generation

Petrochemical Refinery Maintenance. Complete Maintenance Solutions

Boiler Preparation, Start-Up and Shutdown

IGEMA BOILER LEVEL & TDS CONTROLS

DIRECT-FIRED HEATERS: OPERATOR TRAINING. Intensive 2-Day Training Course for Facility Operators

AMMONIA AND UREA PRODUCTION

ALLOY 2205 DATA SHEET

PMCap Local Thin Area Repair and Restoration Component. for Pressure Retaining Items

Energy Saving Fact Sheet Boilers

solarplus solar systems general features

Piping Systems for Nuclear Power Industry. Prague, October 2011

Operating Performance and Latest Technology of DeNOx Plants for Coal-Fired Boilers

Urea DAP MOP. November 08 November 07 April 08 - November 08 April 07 - November 07

Heat Pipe Selection Revision 12/04/2001

Best Choice BENSON BOILER. Excellent performance features make the Benson boiler the most widely used type of once-through boiler

GE Oil & Gas. Air Cooled Heat Exchangers. Robust and reliable for all loads and applications

Steam System Best Practices Condensate System Piping

Transcription:

GAS COOLING SYSTEMS FOR STEAM REFORMING PLANTS

1 1.1 INTRODUCTION is a leading and highly regarded supplier of components and systems for the petrochemical, chemical, refining & metallurgical industries. Decades of experience in process heat transfer for steam reforming processes generating synthesis gas have established ARVOS technical reputation, leadership in the industry and recognition as a reliable partner. 1.2 STEAM REFORMING PROCESS This applies predominantly to the production of synthesis gas (CO, H 2 ) from various feed stocks including natural gas, refinery off-gases, LPG or naphtha. High value products such as hydrogen, ammonia and methanol are generated in further steps downstream of the steam reforming reactor in different catalytic processes. Growing demand for steam reforming based products for chemical and refinery processes as well as the increasing push for alternative fuels is leading to a greater need for steam reforming plants. Different steam reforming processes are the result of a knowledge based interaction between the process heat transfer and reaction kinetics. Plant capacity, product specifications, catalyst technology, feedstock characteristics and desired steam production vary in each individual case. Plant reliability is ensured and production costs are minimized by optimum integration of steam reforming processes and waste heat recovery. Fuel Feed Steam Flue gas Temperature control Air Synthesis gas BFW Figure 1: Typical flow diagram of a steam reforming process

2 FLUE GAS CONVECTION 2.1 WASTE HEAT RECOVERY IN DOWN- STREAM STEAM REFORMER The combustion process in a steam reformer generates flue gas which leaves the reformer at about 1,000 C and is then cooled down to temperatures below 180 C in the convection section. Preferably the recovered heat is returned to the steam reforming process, making the flue gas cooling system an integral part of a steam reforming plant. All process and site specific requirements must be taken into account and integrated in the design. For the material flows in the steam reforming process different types of heat exchangers and a wide variety of arrangements are possible. Figure 2: 3D model of a convection section casing Figure 3: 3D model of a waste heat recovery system Page 4

Following the direction of the waste gas flow, the typical flow diagram shows the following equipment: 2-stage reformer feed superheaters, hairpin type Steam superheater, hairpin type Combustion air preheater second stage, tube bundle type or plate type Steam generator, tube bundle type Combustion air preheater first stage, tube bundle type or plate type Depending on the process requirements an additional pre-reformer feed preheater as well as a natural gas preheater made as hairpin type can be supplied. For some processes a boiler feed water economizer or even a process condensate preheater is required. For specific operation modes which may result from varying load cases the convection section will be equipped with a combustion system known as duct burner enabling the flue gas to be reheated. Figure 4: One coil of a convection section

2 FLUE GAS CONVECTION 2.2 S EXPERIENCE designs and fabricates convection sections custom-made to meet specific process requirements ideally. experts with extensive knowledge in process design, stress analysis, static calculation and project management expertise assure the reliability, integrity and long life of the equipment. Through the years of experience and close working relationship with its clients, provides standard or adapted designs and modularized components to meet customers specific requirements. State of the art CAE software is used and continuously improved through experience parameters and R&D leading to superior design solutions. Excellence in fabrication is achieved by Schmidtsche Schack s decade long experience in fabrication skills and quality assurance. This specialized facility also enables easy transportation on waterways to sea ports. is certified to fabricate the pressure parts of the convection section in accordance with all main international codes and regulations. Air preheaters of tubular or plate-type heat exchanger design as well as non-pressure bearing parts are manufactured according to our experience and in-house standards. Figure 5: One module during transportation to site Page 6

2.3 S DESIGN CONCEPTS offers two basic design concepts. Boiler derived designs usually use small tube diameters. The tubes hang vertically in a horizontal casing allowing for free thermal expansion downwards. These convection sections consist of prefabricated modules with casing, refractory lining and heating surfaces hence erection time and cost are minimized. For special applications the refractory lined casing can be substituted by a water-cooled membrane wall construction. Refinery based designs are in accordance with API 560 and usually incorporate larger diameter tubes. The tubes are horizontally arranged, guided and held in place in a horizontal casing. In this design the tubes expand thermally in horizontal direction. A special design is a vertical convection section, where the flue gas duct is built as a water-cooled membrane wall construction. Figure 6: 3D model of a complete convection section Figure 8: A convection section module during final assembly Figure 7: A complete convection section just before installation

3 PROCESS GAS COOLING SYSTEMS 3.1 SYSTEM DESCRIPTION The process gas leaving the reformer catalyst tubes and the secondary reformer enters the process gas cooler where saturated steam is produced on the shell side while cooling the gas in the process tubes. The unit operates under natural circulation and is connected to the steam drum via downcomers and risers where the steam and water are separated. Depending on the process requirements, the gas downstream of the process gas cooler is used to superheat steam, preheat boiler feed water/feed or enters the CO-shift converter. s scope of supply and services includes Process gas cooler Steam superheater HT shift gas boiler Steam drum Interconnecting piping Accessories Steel structure Supervision of erection and start-up Figure 9: 3D model of a process gas cooling system Page 8

3.2 SCHMIDT SCHE PROCESS GAS BOILER s main design features are Fire tube design Single- or twin-compartment design Refractory lined gas inlet chamber Thin, flexible or super flexible tube sheets Inlet tube sheet is protected by ferrules and refractory lining Full penetration, crevice-free tube to tube sheet welding to avoid crevice corrosion Two bypass designs to control gas outlet temperature: a conventional hot bypass design or an im proved cold bypass design for operation free of metal dusting. Figure 10: Thermocolour painted gas inlet chamber Figure 11: Schmidt sche Process Gas Cooler for a 2000 MTPD ammonia plant during erection

3 PROCESS GAS COOLING SYSTEMS 3.3 S FLEXIBLE TUBE SHEET DESIGN The thin flexible tube sheet design in Schmidt sche Process Gas Coolers is an optimal solution to avoid excessive stress build-up in the tube to tube sheet connection which results from differential thermal elongation between the tubes and shell. The combination of high gas side pressure, high gas temperature and process gas composition results in heat fluxes in the tube inlet area which are higher than those found in other boiler applications. This requires efficient cooling of the process tubes and tube sheets which is accomplished by keeping the wall thicknesses as thin as possible. In comparison to a non-flexible tube sheet design, the tube sheets are supported by process tubes which act as anchors. With this reinforcement of the tube sheet there is no need for stiffening braces which reduce the water volume in the area of the highest heat flux where the highest flow of cooling medium is required. As a result, the tubes stay straight during operation, preventing plastic deformation caused by tube buckling as observed in other designs. Figure 12: FEM model of a flexible tube sheet s thin flexible tube sheets Shell t sat t sat + t Straight tubes Deflected tube sheet Stiffened tube sheets Shell Stiffeners t sat t sat + t Bent tubes Flat tube sheet Figure 13: s flexible versus stiffened tube sheet design Page 10

3.4 S SUPER FLEXIBLE TUBE SHEET DESIGN SUPLEX For extreme process conditions and mechanical design requirements, such as high pressures, long tubes or larger boiler diameters, has developed and is using a highly sophisticated proprietary design called super flexible tube sheet (SUPLEX tube sheet). This tube sheet concept is characterized by specially shaped connections of tube sheet with cooler shell and gas chamber respectively, allowing for highly flexible behaviour. As with s flexible tube sheet design, the process gas tubes act as anchors, hence the tubes stay straight during operation of the Process Gas Cooler. Gas inlet Figure 14: Principle sketch of s SUPLEX tube sheet s SUPLEX tube sheet has been successfully applied in a number of process gas coolers in methanol and ammonia plants. Figure 15: Schmidt sche Process Gas Cooler with SUPLEX tube sheet

3 PROCESS GAS COOLING SYSTEMS 3.5 TUBE TO TUBE SHEET CONNECTION Due to the high heat flux at the tube inlet, the conventional tube to tube sheet connection, in which the tubes are rolled, expanded and welded, are not used, because crevice corrosion may occur in the non-welded portion where water can evaporate and de-compose in the crevice between the tube and bore hole. For this cooler design the SCHMIDTSCHE SCHACK tube to tube sheet connection is made on the rear of the tube sheet. The design is in accordance with all relevant national codes and is the only crevice-free weld type expressly implemented in ASME Code Section I. The only reliable way to avoid crevice corrosion is to use full penetration crevice-free attachment of tubes. has used this design for more than 30 years. Neither crevice corrosion nor mechanical problems have been reported. Figure 16: Tube to tube sheet connection executed as a full penetration weld Figure 17: Crevice-free tube to tube sheet connection Page 12

3.6 FERRULES The tube inlet area is protected by refractory lining and ferrules. Two types of ferrules are used: Ceramic ferrules offer the highest metal dusting resistance at reasonable cost but have low resistance to cracking. Metallic ferrules provide lower pressure loss due to low wall thickness and higher resistance to cracking but are exposed to metal dusting effects. Both ferrule designs extend into the tubes and are wrapped with ceramic fibre paper to increase the insulation effect. 3.7 MANAGING METAL DUSTING Metal dusting is a special form of high-temperature corrosion, generally occurring in reducing and strongly carburizing atmospheres at metal temperatures in the range of approximately 500 to 750 C. Metallic ferrules, bypass liners and in particular the bypass control devices are exposed to metal dusting. Several measures can limit and preferably avoid the effects of metal dusting: Substitution of metallic by ceramic material Limited measure due to brittle nature of ceramic material. Application of high chrome or nickel base alloys Improves resistance and lifetime but does not eliminate the risk in general. Thermal spray or diffusion coating Results are similar to the application of high chrome or nickel base alloys but at a higher cost. Avoidance of metal dusting Designing the boiler such that all critical metal surfaces operate below or above the temperature range to avoid the effects of metal dusting.

3 PROCESS GAS COOLING SYSTEMS 3.8 S COLD BYPASS DESIGN In conventional hot bypass cooler designs the gas leaves the bypass essentially uncooled. The internal bypass in s cold bypass design uses a number of individual larger process tubes installed in the centre of the boiler that cool the gas as it flows to the outlet channel. The temperature of the gas on leaving these bypass tubes is high enough to control the process gas temperature at the cooler outlet as it mixes with the gas flow from the main tube bundle of the boiler. Throughout the cooler, the temperature is kept below the critical metal dusting temperature, hence the cold bypass design which eliminates metal dusting corrosion. The process gas leaving the cold bypass tubes is collected in a gas-tight conical channel and guided through a central flap for controlling the gas flow. The process gas stream leaving the main heating surface is also collected in a gas-tight channel before passing through two additional flaps for controlling the gas flow. The control of both process gas streams achieves the desired mixed cooler gas outlet temperature. Since all three flaps are installed on a common shaft, only one actuator is required, which means that the cooler gas outlet temperature is defined by a single control variable. Figure 18: Typical cold bypass tube arrangement Page 14

The patented cold bypass design with more than 20 years of successful operating results is still the state of the art and is a dependable means of avoiding metal dusting corrosion. Experienced clients have made the cold bypass design a mandatory requirement in their specifications. Figure 19: Bypass valve Figure 20: Control of boiler outlet temperature by cold bypass 880 880 840 800 838 C Gas leaving cold bypass 840 800 Gas leaving cold bypass 760 760 720 720 680 680 Gas temp. [ C] 640 600 560 Critical range of metal dusting Gas temp. [ C] 640 600 560 Critical range of metal dusting 520 520 480 440 Mixed gas leaving PGB 480 440 Mixed gas leaving PGB 400 360 320 359 C 311 C Gas leaving heating surface 400 360 320 431 C 350 C 304 C Gas leaving heating surface 280 0 20 40 60 80 100 Bypass flow rate [%] Figure 21: Conventional design 280 0 20 40 60 80 100 Bypass flow rate [%] Figure 22: s metal dusting free design

3 PROCESS GAS COOLING SYSTEMS 3.9 STEAM SUPERHEATER Saturated steam leaving the steam drum may need to be superheated. For this a superheater is installed, e.g. downstream of the process gas cooler. s steam superheaters are vertical heat exchangers with U-tubes and baffle plates. Further design features: The hot process gas at no point contacts the pressure vessel wall. The upper head is designed as a combined steam inlet and outlet chamber. The internal gas bypass valve is used to control the gas outlet temperature. The complete U-tube bundle together with the upper head can be removed through the top. STEAM INLET STEAM OUTLET Figure 23: Tube sheet detail GAS INLET GAS OUTLET Figure 24: steam superheater for a 650 MTPD ammonia plant (during manufacture) Figure 25: Principle sketch of a u-tube type steam superheater Page 16

3.10 HT SHIFT GAS BOILER The process gas leaving the shift reactor is cooled in an HT shift gas boiler. The boiler is a fire tube design with flexible tube sheets. Operating temperature and heat flux in this boiler are relatively low. For this application SCHMIDTSCHE SCHACK uses its standard tube to tube sheet connection in which the tubes are hydraulically expanded and welded. The HT shift gas boiler operates under natural circulation and is connected to a steam drum via downcomer and riser piping. SHIFTGAS INLET WATER/STEAM OUTLET SHIFTGAS OUTLET WATER INLET Figure 26: Principle sketch of HT shift gas boiler

3 PROCESS GAS COOLING SYSTEMS 3.11 STEAM DRUM The steam drum in a steam generating system operating under natural circulation provides: spare water volume which allows further operation of the steam generator for a limited time period to take adequate countermeasures in case of boiler feed water cut-off. separation of the water/steam mixture generated in the boiler which enters the steam drum via the riser piping. The required steam quality is achieved by the installation of a wire mesh demister in front of the steam outlet nozzle. To avoid water droplets being directly carried over from the turbulent water surface (especially at high water levels) to the surface of the demister, a special plate construction is provided below the demister surface. The steam drum is furnished with ade quate internals and with all required nozzles and manholes. If required by the plant operation, a surface-type attemperator may be installed into the steam drum to control the steam/feed temperature. The arrangement of the steam drum can be either saddle supported or directly on top of the process gas boiler by heavy walled risers as a piggyback version. Figure 27: Principle sketch of steam drum Page 18

4 SYNLOOP WASTE HEAT BOILER The waste heat boilers in the ammonia synthesis loop are exposed to very high operating pressures, resulting in huge mass flow densities and thermal heat fluxes. The synthesis gas consisting essentially of hydrogen, nitrogen and ammonia is under pressure of 200 to 250 bar. In the waste heat boiler the synthesis gas is cooled down from approx. 450 C to approx. 340 C whereby high pressure saturated steam of about 120 to 140 bar is produced. s competence in engineering work and highly qualified manufacturing guarantee the required high quality of the Synloop Boiler. Main features of the SCHMIDTSCHE SCHACK Synloop WHB design are U-tube design Tube sheet face on the gas side is covered by an Inconel cladding Inlet tubes are protected by Inconel ferrules The hot gas stream is led from the gas inlet nozzle via internal metal duct directly to the tube sheet No contact of the hot synthesis gas with the ferritic wall of the pressure shell The metal skin temperature of ferritic parts can be kept safely under the critical nitriding temperature Figure 29: Vertical arrangement of a synloop waste heat boiler STEAM OUTLET BFW INLET SYNGAS INLET WATER/STEAM OUTLET SYNGAS OUTLET WATER INLET Figure 28: Horizontal arrangement of a SCHMIDTSCHE SCHACK synloop waste heat boiler SYNGAS INLET SYNGAS OUTLET

Gas Cooling 07/2015 ARVOS GmbH Ellenbacher Strasse 10 34123 Kassel, Germany Phone +49-561-9527 111 info.shg@arvos-group.com ARVOS GmbH Parsevalstrasse 9A 40468 Düsseldorf, Germany Phone +49-211-4726-0 info.schack@arvos-group.com ARVOS Inc 6500 Brooktree Road, Suite 300 Wexford, PA 15090, USA Phone +1-724 9355725 mail.shgus@arvos-group.com ARVOS K.K 2-3-4 Minatojima-nakamatchi, Chuo-ku Kobe, 650-0046, Japan Phone +81-78-3035718 hirokazu.matsutani@arvos-group.com www.arvos-group.com