Automated Control System Design for Ultra Supercritical Thermal Power

Similar documents
A Review on Power Generation in Thermal Power Plant for Maximum Efficiency

Hybrid Modeling and Control of a Power Plant using State Flow Technique with Application

Boiler Calculations. Helsinki University of Technology Department of Mechanical Engineering. Sebastian Teir, Antto Kulla

APPLIED THERMODYNAMICS TUTORIAL 1 REVISION OF ISENTROPIC EFFICIENCY ADVANCED STEAM CYCLES

OROT RABIN POWER STATION UNITS x 350 MW

Efficiency on a large scale CFB Steam Boilers

PERFORMANCE EVALUATION OF NGCC AND COAL-FIRED STEAM POWER PLANTS WITH INTEGRATED CCS AND ORC SYSTEMS

5. State the function of pulveriser. The pulverisers are the equipments which are used to powdered coal.

OPPORTUNITIES FOR HEAT RATE REDUCTIONS IN EXISTING COAL- FIRED POWER PLANTS: A STRATEGY TO REDUCE CARBON CAPTURE COSTS

4 th EU Sout Africa Clean Coal Working Group Meeting

Drying of Woody Biomass. Process Engineering / GEA Barr-Rosin

Improved Modern Control Station for High Pressure Bypass System in Thermal Power Plant

Design and Operating Experience of the Latest 1,000-MW Coal-Fired Boiler

912 MW Supercritical Boiler for the next Coal Fired Plant Generation

RELIABLE AND EFFICIENT STEAM GENERATION SYSTEMS FOR MODERN UTILITY SERVICE

Sulfur Tail Gas Thermal Oxidizer Systems By Peter Pickard

New-generation Integrated Monitoring and Control System

Performance of the Boiler and To Improving the Boiler Efficiency Using Cfd Modeling

Committed to make a better world

NAWTEC CONCEPTS AND EXPERIENCES FOR HIGHER PLANT EFFICIENCY WITH MODERN ADVANCED BOILER AND INCINERATION TECHNOLOGY

Overview of Waste Heat Recovery for Power and Heat

An analysis of a thermal power plant working on a Rankine cycle: A theoretical investigation

Best Choice BENSON BOILER. Excellent performance features make the Benson boiler the most widely used type of once-through boiler

CONTENTS. ZVU Engineering a.s., Member of ZVU Group, WASTE HEAT BOILERS Page 2

JASE-world Waste to Energy Sub WG Masanori Tsukahara Hitachi Zosen Corporation

SRS: THE STANDARDIZED REPOWERING SOLUTION FOR 300MW STEAM POWER PLANTS IN RUSSIA. Matthias Fränkle Siemens Power Generation (PG), Germany

THEORETICAL ANALYSIS OF THE PERFORMANCE OF DUAL PRESSURE CONDENSER IN A THERMAL POWER PLANT

Natural Gas Conversions of Existing Coal-Fired Boilers

DE-TOP User s Manual. Version 2.0 Beta

Module 5: Combustion Technology. Lecture 34: Calculation of calorific value of fuels

Study of a Supercritical CO2 Power Cycle Application in a Cogeneration Power Plant

The Technology and Business of Power Andrew Valencia, P.E. Lower Colorado River Authority

INTEC Engineering GmbH Heating Solutions for the Marine Industry

Basics of Steam Generation

HYBRID WAY EAF OFF GAS HEAT RECOVERY -ECORECS- MASANARI YAMAZAKI*1, YASUHIRO SATO*2, RYUTARO SEKI*3

Description of Thermal Oxidizers

Performance Analysis of Thermal Power Station: Case Study of Egbin Power Station, Nigeria

steam centre of excellence Steam Boiler System Optimization

Overview of Integrated Coal Gasification Combined-cycle Technology Using Low-rank Coal

Steam Generation Efficiency Module Blowdown Losses Section

Torino Nord. Cogeneration Plant. The gas turbine. The steam generator. The Torino Nord cogeneration plant produces electricity and heat for district

Webpage: Volume 3, Issue IV, April 2015 ISSN

Heat Exchangers in Boilers

Steam Turbine Concepts for the Future Volatile Power Market

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS

HC900 Boiler Control. Background. Solution. Application Brief Industry: Manufacturing

COGENERATION. This section briefly describes the main features of the cogeneration system or a Combined Heat & Power (CHP) system. 36 Units.

INSTRUCTION MANUAL. Boil-Out TABLE OF CONTENTS SAFETY WARNINGS 2-3 RESPONSIBILITY 3 INTRODUCTION 3 PRE-BOIL OUT PROCEDURES 3-5 BOIL OUT PROCESS 5-9

TRIAL CHEMICAL CLEANING OF FOULED APH BASKETS

Chapter 2.2: Boilers

Thermodynamical aspects of the passage to hybrid nuclear power plants

Efficiency Assessment of Condensing Steam Turbine

Condensing Boiler Efficiency

Low grade thermal energy sources and uses from the process industry in the UK

Review of Potential Efficiency Improvements at Coal-Fired Power Plants

Condensing Economizers Workshop Enbridge Gas, Toronto. MENEX Boiler Plant Heat Recovery Technologies. Prepared by: Jozo Martinovic, M A Sc, P Eng

COMBUSTION. In order to operate a heat engine we need a hot source together with a cold sink

HC900 for Boiler Control Applications

Skoda Supercritical Steam Turbine 660 MW

Recover Heat from Boiler Blowdown Water

HYBRID COMBINED CYCLE POWER PLANT

ALUMINUM. BestPractices Assessment Case Study. Alcoa North American Extrusions Implements Energy Use Assessments at Multiple Facilities.

Air-sourced 90 Hot Water Supplying Heat Pump "HEM-90A"

Building Energy Systems. - HVAC: Heating, Distribution -

BEST PRACTICE GUIDE. Energy Efficiency: Steam, Hot Water and Process Heating Systems

C H A P T E R T W O. Fundamentals of Steam Power

MODULE 1. Thermodynamics cycles can be divided into two generation categories :

1. A belt pulley is 3 ft. in diameter and rotates at 250 rpm. The belt which is 5 ins. wide makes an angle of contact of 190 over the pulley.

A car air-conditioning system based on an absorption refrigeration cycle using energy from exhaust gas of an internal combustion engine

Design and Test Operation Performance of 1,500 C Class Gas Turbine Combined-Cycle Power Plant:

Completion of High-efficiency Coal-fired Power Plant

Exergy Analysis and Efficiency Improvement of a Coal Fired Thermal Power Plant in Queensland

Power Plants. BENSON Once-Through Heat Recovery Steam Generator. Power Generation

How To Calculate The Performance Of A Refrigerator And Heat Pump

BOILER OPERATORS HANDBOOK

Originators of the Flexible Water Tube design

KU DESIGN GUIDELINES APPENDIX XVI RECOMMENDED BAS I/O CONTROL POINTS BY EQUIPMENT / SYSTEM

HEAT RECOVERY OPTIONS FOR DRYERS AND OXIDIZERS

I. STEAM GENERATION, BOILER TYPES

Energy Saving Fact Sheet Boilers

FLASH TANK ECONOMIZER PRODUCT GUIDE

POLYCITY. Technical measures and experiences at a 6 MW cogeneration plant with wood chip furnace POLYCITY

A Case Study on Coal to Natural Gas Fuel Switch

Factory owners must ensure the boiler is:

Stora Enso Fors Ltd Sweden

Experimental Study on Super-heated Steam Drying of Lignite

Boiler Preparation, Start-Up and Shutdown


1.3 Properties of Coal

IMPROVING BOILER EFFICIENCY BY USING AIR PREHEATER

Optimization Design for Sulfur Dioxide Flow Monitoring Apparatus in Thermal Power Plants Hao-wei Hu 1, a, Xue Yang 1, b and Xiao-wei Song 1, c

International Journal of Engineering Research and Development

Tips for burner modulation, air/fuel cross-limiting, excess-air regulation, oxygen trim and total heat control

AIR CONDITIONING TECHNOLOGY

High-performance steam boiler and hot water boiler plants for industry

SULFUR RECOVERY UNIT. Thermal Oxidizer

BEST PRACTICES ADOPTED IN JINDAL STEEL & POWER LTD., RAIGARH TO ACHIEVE ENERGY EFFICIENCY. Presented By : Kumar Rohit Sudhanshu Rometra

High Efficiency Low Emissions: The first way forward for clean coal technology. Dr Andrew Minchener OBE General Manager IEA Clean Coal Centre

Steam Generator Boilers Compact Steam Boilers. Rapid Start-Up Safe in Operation

Fortum bygger Sveriges största biokraftvärmeverk i Stockholms stad. Daniel Nilsson Värme & Kraftkonferensen, Stockholm 12 november 2014

Transcription:

Journal of Advanced Engineering Research ISSN: 2393-8447 Volume 2, Issue 2, 2015, pp.51-56 Automated Control System Design for Ultra Supercritical Thermal Power P. Kiruthika 1,*, P. Navaseelan 1, L. Senthilnathan 2 1 Electronics and Instrumentation Department, Easwari Engineering College, Chennai- 600 089. India 2 Yokogawa, Chennai, Tamil Nadu- 600 006, India *Corresponding author email: kiruthikaprabhakar@gmail.com ABSTRACT The work taken up for this paper is the implementation of process automation using DCS for Ultra Supercritical thermal power plant. Coal has been the king in the global electric power production and will continue to serve in this role in the future. Worldwide energy and electricity consumption is projected to grow at an average annual rate of 2 2.5% between now and 2025 caused by increase of population (up to 7.5 billion) and increase of consumption (mainly of China and India).Hence, by increasing the efficiency of existing power plants, using clean technologies and adoption of ultrasupercritical boiler, wherever cost effective and otherwise suitable is preferred. The Gross plant efficiency is around 41 42% for ultra supercritical units with steam parameters of 28MPa/975k, which is about 3 4% higher than that of the supercritical units. The control of large scale ultra-super critical power plant is very complicated and highly nonlinear because it involves the measurement and control of number of parameters in order to increase the overall plant efficiency by Optimizing the combustion process, increasing the steam parameters, reducing the condenser pressure and improving the internal efficiency of the steam turbines. Thus, Monitoring and control system such as DCS/SCADA are responsible for managing critical infrastructures operating in these environment. The control of various components such as once through boiler parts super heater (temperature, pressure, flow), reheater (temperature, pressure, flow), economizer (temperature, pressure and flow), air Preheater (temperature), burners (air/fuel ratio) and turbine operating conditions is implemented using the CENTUM CS 3000 of Yokogawa India ltd. Keywords - Automation, coal fired power plant, control system design, Distributed control system (DCS), once through boiler, ultra super critical power plant. 1. INTRODUCTION Ultra supercritical (USC) power plant is the next generation power plant which operates with a steam pressure in the range of 300 bar and steam temperature above 975k. The efficiency of the power plant is proportional to operating temperature and pressure which are limited by number of power plant components. In this thesis, the main objective is to to increase the efficiency of the power plant by Controlling and monitoring the pressure, temperature and flow through the once through boiler parts (super heaters, reheaters, economizers), air preheater, the temperature of HP,IP and LP turbine and also to maintain the air-fuel ratio of burner and furnace pressure. Various control system loops are implemented and graphic window for the USC power plant is configured. 2. 1000MW USC POWER PLANT The power plant under investigation is a coalpulverised, once-through-type, boiler-turbine-generator unit. The USC coal fired power plant consists of four processes, which are air/flue gas, pulveriser, water/steam, and turbine/generator.there are three economizers used to raise the temperature of water entering the boiler from the feed water system. Two forced draft fans and two primary air fans provide air to the air preheated. The air preheater in turn provides heated air to the pulverisers, burners, and furnace. The primary air fans also provide cold air to the pulverisers. The fuel is provided to the furnace through the pulverisers and burners. Furnace pressure is maintained at the desired value by controlling two induced draft fans. The waterwall surrounds the furnace vertically and spirally. Flue gas exiting the furnace travels through the super heaters and reheaters, economizers, and air preheater to raise the temperature of the steam, water, or air, respectively. There is a separator on top of the furnace, which Research Article 51 www.jaeronline.com

supplies high-pressure (HP) steam to the primary superheater and reduces the impurities in the steam. The superheater consists of four parts: primary, division, platen, and finish. The reheater reheats the steam after the HP turbine using the primary reheater and the reheater finish. Finally, the turbine converts the enthalpy of the steam into rotary motion of the tandem compound triple turbines, which consist of three parts: a HP turbine, an intermediate-pressure (IP) turbine, and low-pressure (LP) turbine which is then connected to the alternator to produce electricity. with large heat transfer surface and can be accommodated in small volume. As motor starts, metal plates move from hot combustion passage and exchange the heat to the cool incoming air. 3.2 Primary and Secondary Air Fans A fan can be considered as a mechanical device that moves a volume of fluid such as air, gas or vapour through a pressure driven flow. The term draft indicates the movement of the combustion air and flue gases. Forced draft fan is used to regulate the combustion air. Induced draft fan is used to regulate the furnace pressure. Control can be done by fan speed or damper action. Furnace pressure is affected by both forced draft fan and induced draft fan. Fig 1. Block diagram of USC power plant 3. OPERATION OF DIFFERENT SUB SYSTEM Fig.3. Control drawing builder of forced draft fan. 3.1 Air Preheater Fig.4. LC64 interlock for motor control. 3.3 Burner Fig.2. Control drawing builder of Air preheater. The purpose of the air preheater is to recover the heat from the boiler flue gas which increases the thermal efficiency of the boiler by reducing the useful heat lost in the flue gas. Air of the temperature range 150-420 C is needed for drying coal in the pulveriser. The most common type is rotary air preheater known as Ljungstrom air preheater which consists of a rotor, driven by a motor. They are compact heat exchanger Fig.5. Control drawing builder of Air/fuel ratio Research Article 52 www.jaeronline.com

The raw coal is fed into the pulverizer along with air heated to about 650 degrees F from the boiler. Air fuel ratio is the ratio between the mass of air and the mass of fuel in the fuel air mix at any given moment. The mass is the mass of all constituents that compose the fuel and air, whether combustible or not. 4. ONCE THROUGH BOILER PARTS Superheater is a heat exchanger in which heat is transferred to the saturated steam to increase its temperature. Steam temperature is normally controlled by spraying water into the steam between the first and second-stage superheater to cool it down. Water injection is done in a device called an attemperator or desuperheater. The spray water comes from the pump discharge (for superheater spray). Improved disturbance rejection can be achieved by implementing a secondary (inner) control loop at the desuperheater. This loop measures the desuperheater outlet temperature and manipulates the control valve position to match the desuperheater outlet temperature to its set point coming from the main steam temperature controller. In this case,3 desuperheater are present then FOUT block (CS3000) is used to distribute the signal from primary controller to 3 secondary controllers. OUT is a signal distributer block which has single master and multiple slaves.. Fig.8. SCADA of superheater temperature control Fig.9. SCADA of superheater pressure control 4.2 Reheaters Reheaters are similar to superheater with almost same steam outlet temperature and with a steam temperature about 25 % of superheaters. Reheater temperature can be controlled by injecting feed water into cold reheat steam side. Fig.6. Control drawing builder of superheater temperature control Fig.10. Control drawing builder of reheater pressure control Fig.7. Control drawing builder of superheater pressure control Fig.11. Control drawing builder of reheater temperature control Research Article 53 www.jaeronline.com

Fig.15. SCADA of economiser temperature control Fig.12. SCADA of reheater temperature control Fig.13. SCADA of reheater pressure control 4.3 Economiser Economizer is a heat exchanger, which raises the temperature of the feed water leaving the highest pressure feedwater heater to about saturation temperature corresponding to boiler pressure.this is done by the hot flue gases exiting the last Superheater or reheater at a temp. Varying from 370 C to 540 C. Fig.16. SCADA of economiser pressure control 4.4 Turbine and Condenser Parts Steam turbines for USC steam conditions require application of advanced alloy steels for the HP and IP turbines and for the main and reheat steam admission valves. Fig.14. Control drawing builder of economiser Fig.17. Control drawing builder of IP Turbine Research Article 54 www.jaeronline.com

Fig.18. Control drawing builder of LP&HP Turbine 4.5. Condenser Fig.21. Trend window for Super heater temperature control Condensers are heat exchangers which convert steam from its gaseous to its liquid state at a pressure below atmospheric pressure. A water-cooled shell and tube heat exchanger installed on the exhaust steam from a steam turbine in thermal power stations is called as surface condenser. Fig.22. Trend window for Super heater Pressure control Fig.19. Control drawing builder of condenser 5. TREND WINDOW CONFIGURATION FOR USC POWER PLANT Trend window is used for graphical representation of controller parameters with respect to time. In this paper, trend window of various parts of USC power plant is shown. Fig.23. Trend window for Economiser Fig.20. Trend window for Air/fuel ratio Fig.24. Trend window for Reheater Research Article 55 www.jaeronline.com

Fig.25. Trend window for Condenser efficiency of the USC power plant is improved by controlling and monitoring the pressure, temperature and flow through the various parts of the once through boiler (super heaters, reheaters, economisers) and also the air/fuel ratio is maintained automatically according to the demand. The temperature of the air preheaters are also controlled before it mixes with the burners to undergo combustion. Both open loop and close loop control is executed for the condenser process. Also turbine operating conditions is maintained by regulating feed water heaters automatically. Thus, the monitoring and control of the entire plant is done using DCS and it helps to reduce human intervention and increases the safety of the plant. REFERENCE Fig.26. Trend window for Low pressure turbine Fig.27. Trend window for Low pressure turbine Fig.28. Trend window for Intermediate pressure turbine 6. CONCLUSION Automated control system design is done for large scale ultra-super critical power plant using YOKOGAWA DCS (CENTUM CS3000).The overall [1] Kwang Y. Lee, Joel H. Van Sickel, Jason A. Hoffman, Won-Hee Jung and Sung-Ho Kim, Controller Design for a Large-Scale Ultra supercritical Once-Through Boiler Power Plant, IEEE Transactions on Energy Conversion, 25 (4) 2010. [2] Ki-Yong Oh,Geon-Pyo Lim and HoYol Kim, Simulator Development of 1000MW Class Ultra Super Critical Coal-Fired Power Plant with advanced control algorithm, Energy & Mechatronics Group, Strategy Technology Laboratory, KEPRI (Korea Electric Power Research Institute) science Town, Daejeon 305-380. [3] Xiangjie Liu, XueweiTu, GuolianHou and Jihong Wang, The Dynamic Neural Network Model of a Ultra Super-critical Steam Boiler Unit, 2011 American Control Conference on O'Farrell Street, San Francisco, CA, USA June 29 - July 2011. [4] Xi Zhang and Shihe Chen Guangdong Electric Power Research Institute China.Weiwu Yan and Guoliang Wang, Research on the Application of Multi-Model Predictive Control in Coordinated Control of 1,000MW Ultra- Supercritical Unit2013 IEEE International Conference on Systems, Man, and Cybernetics, Department of Automation Shanghai Jiaotong University Shanghai, China. [5] Omar Mohamed, Jihong Wang, Bushra Al- Duri, Junfu Lu, Qirui Gao, YaliXue, Xiangjie Liu, Predictive Control of Coal Mills for Improving Supercritical Power Generation Process Dynamic Responses, 51st IEEE Conference on Decision and Control, Maui, Hawaii, USA, December 10-13, 2012. Research Article 56 www.jaeronline.com