General technical information

Similar documents
CHECKING AND TESTING ELECTRICAL INSTALLING WORK

Protection catalogue 15

SELECTION OF FINAL CIRCUIT PROTECTION

Electrical Practices for Construction Work

ESP 120 M1, ESP 208 M1, ESP 240 M1, ESP 415 M1, ESP 277 M1, ESP 480 M1 and M1R variants. Installation instructions ESP M1/M1R mains protectors

The complete range of consumer switchboards and switchgear

DOMESTIC ELECTRICAL INSTALLATION CERTIFICATE (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)

Fundamentals of Power

ES281 COMPANY-SPECIFIC APPENDICES TO ENA ENGINEERING RECOMMENDATION G81 PART 1

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

NZECP 14: 1995 ISSN COVER PAGE

Unified requirements for systems with voltages above 1 kv up to 15 kv

21 st Century Facilities

MEM10019 Select circuit protection devices by type and rating, fit to switchboards and install earthing

Trouble-shoot and repair faults in low voltage electrical apparatus and circuits

Electrical Essentials for HVAC&R Engineers. Wednesday, October 7

TESTING AND COMMISSIONING PROCEDURE FOR ELECTRICAL INSTALLATION GOVERNMENT BUILDINGS THE HONG KONG SPECIAL ADMINISTRATIVE REGION

Building Regulations P.4. Socket Outlets P.6. Other Considerations P.10. Training Seminars P.24

Securing your electrical installations Prisma,

PROTECTION AGAINST ELECTRIC SHOCK by John Ware

Guide to the Selection & Use of Residual Current Devices

HIGH VOLTAGE SHORE CONNECTION

Application of Four-Pole Circuit Breakers within Data Centers

Use of Residual Current Devices in Departmental Infrastructure

A Guide to 17th Edition Testing

GUIDE TO THE MAINTENANCE, INSPECTION AND TESTING OF PORTABLE EQUIPMENT (ELECTRICAL APPLIANCES AND TOOLS) IN THE WORKPLACE

3.1.1 Full Type Tests & Routine Tests according to Clause 8 2 & Instructions For Installation, Operation & Maintenance

Electrical Resistance Resistance (R)

ELECTRICAL PRACTICES FOR CONSTRUCTION WORK

Uncompromising safety and comfort The next generation of miniature circuit breakers MCB S 200/S 200 M

Residual Current Circuit Breaker

RCD Inspection Log Book

Guidance notes for the installation of electrical supply in mobile trailers for breast screening

SURGE PROTECTIVE DEVICES

Reverse-feed applications for circuit breakers

Electrical safety and protection devices

Permissible ambient temperature Operation Storage, transport

Section B: Electricity

FREQUENTLY ASKED QUESTIONS

FAQs-Main switchboard design criteria

Listed are common requirements that apply to existing solar installations when altered, added to or reconfigured.

BASIC NEC CODE RULES AND DESIGN PRACTICE

6.0 Electrical Installations

LV MCC LOW VOLTAGE SWITCHGEAR MOTOR CONTROL CENTRE PRODUCT GUIDE

Current Transformers

PREFACE. Your comments or suggestions are welcome and appreciated. They should be sent to:

Inverter / Charger Installation General Operations and AC and DC Connections

For a phase-to-phase voltage between 100 V and 1000 V. The standard ratings are: 400 V V V (at 50 Hz)

1. Electrical Equipment A) Transformer

Mini Circuit Breakers, Fuse Blocks, and Electronic Circuit Protection

Protect your home and family with Advanced Technology from Cutler-Hammer

Data Center Power Overload Protection: Circuit breakers and branch circuit protection for data centers

SURGE PROTECTIVE DEVICES (SPDs) LOW VOLTAGE AC EXTERNAL SIDEMOUNT SURGE PROTECTION FOR ELECTRICAL DISTRIBUTION SYSTEMS SECTION 16671B SECTION 16671B

Commercial/Industrial Electricity

TESTING AND COMMISSIONING PROCEDURE FOR ELECTRICAL INSTALLATION GOVERNMENT BUILDINGS THE HONG KONG SPECIAL ADMINISTRATIVE REGION

Comparative study for cables and busbars

ELECTRICAL INSTALLATION CONDITION REPORT (Requirements for Electrical Installations BS 7671 IEE Wiring Regulations)

..OR How To Protect your 3-Phase Equipment Investment with 3-Phase Monitors from Time Mark...

Section 9: Power Distribution Equipment Bill Brown, P.E., Square D Engineering Services

CHAPTER 2 EXAMPLES AND TABLES

8146/5 Series Breaker Panelboards

Unit 4: Electricity (Part 2)

Circuit Breakers. Next Generation of Protection Capabilities

ELECTRICAL - WIRING DESIGN AND PROTECTION SELF INSPECTION CHECKLIST

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

Residual Current Devices. Switching on to Safety

Earth Fault Detection Basics in Theory

Electrical test equipment for use on low voltage electrical systems

EVR01. General description. Input power cord. S.a.s. di Rizzo Davide & C.

BRANDON AND CLARK INC. // SCOTT W. CLARK, P.E. ELECTRICAL CONTINUING EDUCATION ARC FLASH - NFPA 70E

INSPECTION AND TESTING OF ELECTRICAL INSTALLATIONS RESIDUAL CURRENT DEVICES

Ground Fault Protection

5SV Residual Current Protective Devices

Andre Gretler, LPLS BU Function Operation and Sales Low Voltage Systems ANSI vs IEC. BU 3101 Low Voltage Systems June 27, 2013 Slide 1

Circuit Breakers and Switchgear. Thomas Greer Director of Engineering TLG Services

Electrical safety for entertainers

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

Evaluating Water-Damaged Electrical Equipment

Engineering Series Ratings: Is It Practical?

Molded Case Circuit Breakers, Motor Protection Circuit Breakers, and Motor Circuit Protectors. Technical Data

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

R.C.C.B. s two-pole LEXIC

ELECTRICAL INSPECTION BULLETIN (Effective )

Simplified Guide To Understanding Short-Circuit Current Rating FIND IT, FIX IT, FORGET IT

Guidelines on the Short Circuit Current Rating for Industrial Control Panels

Evaluating Water-Damaged Electrical Equipment

Achat 115MA full-range speaker. user manual

ASSEMBLED SOCKET-COMBINATIONS

Part 1 System Modeling & Studies for Existing Systems

GUIDELINES FOR ELECTRICAL WIRING IN RESIDENTIAL BUILDINGS

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

A B Brown. This sheet forms part of *Inspection Report Number/*Certificate Number NA/ * EC/ * PIR *Delete as applicable DB

APPENDIX A PIN-OUT OF RJ12 / RJ45 CONNECTORS. RJ12 connectors

Evaluating Water-Damaged Electrical Equipment

Significant Changes in the 2011 NEC Prepared by Bryan Holland City of North Port

Regulation IO-6.0: Electrical Safety Regulations

The Application of Circuit Breakers to Reduce Downtime in Datacentres

INTERNATIONAL POWER DISTRIBUTION CONGRESS CIDEL ARGENTINA 2002

USER S MANUAL. MaxPower UPS. Uninterruptible Power System 28-2MAXPO0018

Split-type Air-Conditioner INSTALLATION MANUAL CONTENTS FOR INSTALLER MXZ-3A30NA MXZ-4A36NA ATTENTION. English. Français. Español

Transcription:

Circuit breakers 2 Ingress protection 4 Nuisance / unwanted tripping 5

Circuit breakers Prospective Fault Current Calculation of Prospective Short Circuit Current Several excellent proprietary computer programs are now available for calculating the prospective fault level at any point in the installation. They are also able to select the correct size and type of cable and match this with the correct circuit protective device. Estimation of Prospective Fault Current Actually calculating prospective short-circuit current is not in itself difficult but it does require basic data which is not always available to the electrical installation designer. It is therefore usual to use a simple chart as shown in FIGURE 1 to estimate the prospective short circuit current. This type of chart always gives a prospective fault level greater than that which would have been arrived at by calculation using accurate basic data. Therefore it is safe to use but sometimes may result in an over engineered system. Figure 2 Example in figure 2 1 Project 40m of cable length across on to the 240mm 2 cable curve. From this point project down onto the 28kA curve. From this point projecting across we note that the prospective fault level at the panelboard is 24kA. 2 Project 60m of cable length across onto the 70mm 2 cable curve. From this point project down on to the 24kA curve. From this point projecting across we see that the prospective fault level at the MCB distribution board is 10kA. Figure 1 Figure 3 The relationship between probable short-circuit current and service short-circuit breaking capacity is explained. The probable short circuit is the type of short circuit which is most likely to occur; this is nearly always at the extremity of the protected cable and more often than not a single phase or earth fault. Figure 3 shows a typical 3 phase 4 wire 400V system fed by a 1000 kva transformer. The transformer is adjacent to the main switchboard so the prospective short-circuit current (PSCC*) on the main switchboard busbars is estimated as 30kA. The probable shortcircuit current on the panelboard feeder circuit is estimated as 24kA, if it were a 3 phase symmetrical fault, or 12kA for a phase to neutral fault, which in fact would be the most likely type of fault. (Note: when estimating a phase to neutral prospective short-circuit current, the length of conductor is doubled.) Therefore for this application the main switchboard incoming circuit breaker (A) should have an Ics 30kA and an Icu 30kA. The panelboard feeder circuit breaker (B) should have an Icu 30kA and an Ics 24kA.

Circuit breakers Fault loop impedance With the introduction of AS/NZS 3000:2007 there are new wiring rules for electrical contractors and electrical consultants to consider when designing an electrical installation. This guide is only concerned with one new area, fault loop impedance, and it s affect on the choice of conductor and circuit breaker for a given circuit. Voltage drop and overcurrent requirements should also be given consideration. An earth fault situation is caused when an active conductor comes into contact with an earthed conductor - fault current then flows. Contractors and consultants must make sure that the conductors in a circuit will allow sufficient energy to flow to cause the circuit breaker to trip in the required time (disconnection time for 230V supply is 0.4s for socket outlets up to 63A, or handheld Class 1 equipment intended for manual movement during use. 5 seconds for other circuits including submains and final sub circuits supplying fixed or stationary equipment (clause 1.5.5.3) To make sure that this fault current is large enough to trip a circuit breaker in the required time the fault loop impedance (Zs) must be below a certain value. If Zs is too large then the circuit breaker may take too long to trip(> 0.4s) or may not trip at all. - Circuit length: Circuit impedance increases with the length of a circuit. - Cross-sectional area of cable: The smaller the cross -sectional area of a cable, the higher it s impedance per meter will be. - Thermal and magnetic settings of a circuit breaker: Hager circuit breakers have both rated current and magnetic characteristics. The higher the rated current and magnetic settings, the more energy is required to trip the circuit breaker in the required time (< 0.4 s ). So a circuit breaker with a magnetic setting of 14 x In will require more energy to trip it (in the required time) than a circuit breaker with a magnetic setting of 7.5 x In. If more energy is required to flow, then a larger cross-sectional area cable may be needed. If this is not possible then installing a Hager RCD will provide a simple and economical solution. So circuit length, cross sectional area of the cable and circuit breaker settings all need to be taken into account to ensure correct function of a circuit. The tables below are a guide to the maximum circuit length for a given Hager circuit breaker. Using these tables will help ensure that the disconnection time for a 230V a.c. supply is met according to AS/NZS 3000:2007. Conductor size Protective device Hager circuit breaker (AS/NZS60898) rating Active Earth Type C Type D mm 2 mm 2 A MCL (max circuit length in meters) 1 1 6 91 55 1 1 10 55 33 1.5 1.5 10 82 49 1.5 1.5 16 51 31 2.5 2.5 16 85 51 2.5 2.5 20 68 41 4 2.5 25 67 40 4 2.5 32 52 31 6 2.5 40 48 29 10 4 50 62 37 16 6 63 76 45 16 6 80 59 36 25 6 80 66 40 25 6 100 53 32 35 10 100 85 51 35 10 125 68 41 50 16 125 106 63 50 16 160 83 50 70 25 160 126 75 70 25 200 100 60 Maximum circuit length (MCL) and maximum circuit impedance (Zs) for Hager MCBs (MSNxxx, NTxxxC & NDNxxxA ranges). Where: MCL = Maximum circuit length Above table based on supply of voltage of 230V (AS/NZS 3000: 2007)

Ingress protection The first character numeral indicates the degree of protection provided by the enclosures with respect to persons, also the equipment inside the enclosure. The second character numeral indicates the degree of protection provided by the enclosures with respect to harmful ingress of water; a third character may be used to indicate mechanical strength. An x signifies that no test has been carried out. The first character numeral : protection against solid substances IP Designation 0 Non - protected 1 greater than 50mm 2 greater than 12.5mm 3 greater than 2.5mm The second character numeral : protection against liquid substances IP Designation 0 Non - protected 1 Protected against dripping water 2 Protected against dripping water when tilted up to 15 o 4 greater than 1.0mm 3 Protected against spraying at an angle up to 60 o 5 Dust protected 4 Protected against splashing water from any direction 6 Dust - tight 5 Protected against water jets 6 Protected against heavy seas 7 Protected against the effect of immersion 8 Protected against submersion to limits set by manufacture

Nuisance / unwanted tripping RCD Nuisance tripping or Unwanted tripping? It is very tempting to describe RCD tripping due to intermittent electrical fault as Nuisance Tripping. However, Nuisance Tripping probably best describes an RCD that trips for no electrically based reason whatsoever. Intermittent tripping that typically occurs after a new installation, maintenance or wiring modification would suggest that the RCD is performing the very function for which it was designed / installed for (i.e. fault detection & protection). This intermittent or Unwanted Tripping can actually highlight potential problems within the installation, turning the simple exercise of fitting of an RCD, into a huge fault finding exercise. This is not a relished thought for any sparky! Typically Unwanted Tripping on RCDs can stem from misplaced or combined Neutrals. At times, Neutrals intended for protection by the RCD are incorrectly wired to the pre-rcd Neutral bar. Other times, current is accidentally shared between the pre-rcd Neutral bar and post-rcd Neutral bar (e.g. via a common bond that should not exist in the first place). Another important consideration is the effect of Standing Leakage Current & how it relates to Unwanted Tripping Standing Leakage Current & how it relates to Unwanted Tripping on RCDs. Standing Leakage Current is inherently present in all electrical appliances due to the RFI filters and suppressors inside switch mode power supplies on modern appliances such as LCD TVs, Hi-fi systems, PCs and Laptops. This also occurs in leaky cable appliances with pre-existing poor insulation resistance, or an insulation breakdown developed over time. Typically Unwanted Tripping is blamed on the RCD being overly sensitive. More often than not, it is the Standing Leakage Current that is the problem. The steady state sum of Standing Leakage Current in the circuit must be significantly less than the RCD tripping threshold. If this is very close to the RCD tripping threshold, then even the slightest transient disturbance will cause the RCD to trip. Generally, RCDs may trip at any value in excess of 50% of the rated residual current (e.g. 15mA on 30mA RCD). Further care should be taken on installations that are susceptible to high transient disturbances or where particularly leaky appliances may be connected. The recommended Standing Leakage Current steady state threshold is less than 33% of the rated residual current (i.e. 10mA on 30mA RCD). A list of appliance types and corresponding Standing Leakage Currents are listed below: Appliance type Handheld tools and portable appliances Other household appliances Information Technology (Portable) Lighting Appliances 1 Information Technology (Stationary) Electric Stove / Oven Standing Leakage Current up to (ma) / unit 3.5 Up to 0.75 / kw As an example, for a 30mA RCD to stay under the threshold and avoid Unwanted Tripping, it is recommended that a maximum of four computers (desktops/towers) are connected to a single RCD circuit at any one time. The number of computers may need to be further reduced if they have particularly high Standing Leakage Current or when the installation is particularly susceptible to transient disturbances.