Sand Control Systems Perforated Tubing And Casing Systems

Similar documents
C O M P L E T I O N S E R V I C E S

TUBULAR Holing and Slotting Of Casing

June 2007 CHAPTER 7 - CULVERTS 7.0 CHAPTER 7 - CULVERTS 7.1 GENERAL

Perforating Basics. How the perforating processes work. George E. King Engineering GEKEngineering.com 3/14/2009 1

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

SPECIFICATION Aluminum Module Frames. Allowed anodization before fabrication for clear frames.

BLADDER SURGE CONTROL SYSTEM

PRODUCTS. Stainless Steel (Ferritic & Austenitic) Aluminised Steel Mild Steel Titanium

How To Design A 3D Print In Metal

PLATE HEAT EXCHANGER. Installation Manual. Customer Name: Serial number: Purchase order number: Project:

FUEL TANKS DOUBLE WALL FUEL TANKS

SECTION SANITARY SEWER AND STORM DRAIN SYSTEMS

Stainless Steel Perimeter Recirculation Systems Engineered supply and return systems for swimming pools, water features and aquatic facilities.

SUGGESTED SPECIFICATION EXHAUST SYSTEM SILENCER, FLEX CONNECTOR, INSULATION BLANKETS, WALL / ROOF THIMBLES

How to Build a Printed Circuit Board. Advanced Circuits Inc 2004

TEXAS A&M CENTRAL ACADEMIC BUILDIING & PATRIOT S CASA SUBMITTAL Pre-Insulated Piping

ASME Packaged Indirect Fired Water Heater

DIVISION 4300 STORM DRAINAGE

Metal Pressfitting Pipe Systems

Oil and Gas Pipeline Design, Maintenance and Repair

CHAPTER 4 WELL COMPLETION AND MAINTENANCE

TARIFF CODE and updates standard

WATER SERVICE 2

Native InDesign 2890 SaniTite Brochure 1/8" CMYK April 17, 07

NAPCA BULLETIN APPLICATION PROCEDURES FOR CONCRETE WEIGHT COATING APPLIED BY THE COMPRESSION METHOD TO STEEL PIPE

This will also provide you with the knowledge to insure long life for your Investment

GE Oil & Gas. Air Cooled Heat Exchangers. Robust and reliable for all loads and applications

Company and Product Presentation

SERIES ASM NEOPRENE/EPMD FLANGED SINGLE SPHERE CONNECTOR CONNECTORS. Pressures to 225 PSIG (15.51 barg) Temperatures to 230ºF (110ºC)

SECTION STORM DRAINAGE SYSTEM

Premium Tubular Solutions Super Duplex Welded Tubes for Umbilical Applications

Seamless stainless tubes for hydraulic and instrumentation systems

COATING & WRAPPING OF UNDERGROUND PIPING

Heat Exchanger Thin Film Foul Release Applications Corrosion Resistant Protective Coatings Grit Blast Surface Prep of Tubular Equipment

INSITU TESTS! Shear Vanes! Shear Vanes! Shear Vane Test! Sensitive Soils! Insitu testing is used for two reasons:!

FRICTION MATERIALS & BONDING SERVICES

SPECIALTY FIBER OPTIC CABLE. Downhole Sensing Subsea

EUROPEAN OEM SERVICE STAUFF. STAUFF - Line - Local solutions for individual customers worldwide

Stilling Well Recommendations

PIPE REHABILITATION. Industrial Wastewater Municipal Wastewater Drinking Water Pressure Pipes

Selecting TEMA Type Heat Exchangers

DOUBLE GATE KNIFE GATE VALVE

SECTION PIPE HANGERS AND SUPPORTS

Storm Drain Inlet Protection - IP

Depend-O-Lok FxE Expansion Coupling. System No. Submitted By Spec Sect Para Location Date Approved Date. DEPEND-O-LOK FxE EXPANSION COUPLING

Diameter. Swift Lift Round Recess Plug. Note: The diameter of the narrow recess plug is the same as the diameter of the round recess plug.

Technical Specifications BIO-BLOK 80 HD G

DynaSlot System. 360 Certainty Well Abandonment

Good Boards = Results

STANDARD SPECIFICATIONS SECTION CLEANING AND LINING WATER MAINS

Instruction Manual. Cable Splicing. Models , HDF1, HDF SS1

STEADYfast Stabilizer Installation Notes Fifth Wheel and Travel Trailers 11/23/13

GE Oil & Gas. Air cooled heat exchangers Robust and reliable for all loads and applications

Section 21. Telecommunication Hardware. BuyLog Catalog 21-1

SPECIFICATION FOR PIPE SUBSOIL DRAIN CONSTRUCTION

FLEXIBLE CIRCUITS MANUFACTURING

Installation instruction CASAFLEX - Connecting piece DN 100

Mueller. Pipe Repair Products. A complete selection for all types of gas lines... all from a single source. GAS PRODUCTS DIVISION

SUBDRAINS AND FOOTING DRAIN COLLECTORS. A. Construct subdrains, subdrain cleanouts and outlets, and footing drain collectors.

Lead & Magnet Wire Connection Methods Using the Tin Fusing Method Joyal A Division of AWE, Inc.

SERIES NG 1800 STRUCTURAL STEELWORK

50AI01oe 02/15. Labko GRP cesspools. Instructions for installation, operation and maintenance

SPR PE Steel Reinforced Liner

Specifications for Residential Property Owners Connection to New Public Sewer

Chapter 5 - Aircraft Welding

SECTION 1 GENERAL REQUIREMENTS

San Antonio Water System Standard Specifications for Construction ITEM NO SLIP-LINING SANITARY SEWERS

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

T A B L E T 1 T E S T S A N D I N S P E C T I O N C A B L E P C U T A N D P C U T - A

Dot matrix Label ID Products. C Vinyl cloth labels. Dot Matrix. Features and benefits. Part numbering system

EXHIBIT "A. Technical Specifications for Water and Sewer Service Lines

GOODYEAR COMMERCIAL TIRE SYSTEMS TIRE CASING RETREAD AND REPAIR MANUAL FOR ECDII AND DURASEAL TECHNOLOGY

ELECTRICAL SAFETY Information Bulletin

Argentina Tataru*, Marcel Adrian Piteiu*, Dan-Paul Stefanescu*, Ioana Vlasin*

API Flanged Safety Relief Valves Series 526 CATALOG

Meeting the Challenge of Pipeline Emergency Repair

Originators of the Flexible Water Tube design

Fume Extraction: Guide to Safely Managing Solder Fumes in the Workplace

CHAPTER 5. OVERVIEW OF THE MANUFACTURING PROCESS

IHSS-N1 WELDED HONEYCOMB CORE SPECIFICATION. Generated: Sergiy Papyshev Engineering. Approved: Don Prysi Manufacturing. Approved: Merzuk Ramic Quality

Rebuild Instructions for and Transmission

UNDER DRAINAGE AND FILTER DESIGN

Table 4.9 Storm Drain Inlet Protetion Applicable for

T U R B I N E G A S M E T E R

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

Vrtné trubky Drill Pipe

Final inspections are completed by site visit only. Access to fenced yards shall be planned.

SECTION PRECAST CONCRETE UTILITY STRUCTURES

Wastewater Capital Projects Management Standard Construction Specification

The Most Advanced Name in Drainage Systems. Sanitary Sewer Pipe

Table of Contents. Western States Standing Seam SS675 Panel Installation, Flashings & Shop Drawing Detail Guide. Notes to Designer /Installers..

TABLE OF CONTENTS. SECTION 1 General Information: Pg 2 Description of Operation

The work of this Section includes furnishing and installing Reinforced Concrete Pressure Pipe as shown on the Drawings and as specified.

Drill Pipe Hard-facing

PAAM COMMERCIAL PRIVATE LIMITED

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued November 1, Legacy report on the 1997 Uniform Building Code

Air Eliminators and Combination Air Eliminators Strainers

SUPPLEMENTAL TECHNICAL SPECIFICATIONS BI-DIRECTIONAL STATIC LOAD TESTING OF DRILLED SHAFTS

BRAZED PLATE INSTALLATION MANUAL

System Solutions for Boiler Air Preheating

Transcription:

Sand Control Systems Perforated Tubing And Casing Systems Keeping Sand In Its Place Since 1969

Wire Wrapped Base Pipe Screen The Variperm All Welded Wire Wrapped Base Pipe Screen is leading the industry in superior construction, durability, and quality. With a proven record it is a simple choice for reliable sand free production for either vertical or horizontal oil wells. Wire Wrapped Screen maximizes the open area by utilizing an accurately controlled gauge as low as 0.003". The gauge, or slot size, is determined from a sieve analysis of a formation core sample. Gauge spacing of the Wire Wrapped Screen is permanent. The specified gauge is maintained downhole under the roughest handling conditions. There are no solder strips, weldbeads, or lugs to block the fluid flow around or through a Wire Wrapped Screen. The large inlet area allows higher production rates with lower entrance velocities and minimal pressure drop. Casing and tubing which are utilized in the manufacture of Base Pipe Screen are high quality and meet all API standards. Mill certifications and conformance reports are kept on file for all products. Variperm's screen products are manufactured to meet the specific needs of each individual client, ensuring that every screen is the right screen. Base Pipe Holes Holes Hole Hole Screen NU Coupling EU Coupling Per Per Size Open Area inches mm foot meter inches sq.in./ft inches mm inches mm inches mm 1.900 48.26 84 275.6 3/8 13.0 2.423 61.54 2.200 55.88 2.500 63.50 2.375 60.33 96 315.0 3/8 11.8 2.898 73.61 2.875 73.03 3.063 77.80 2.875 73.03 60 196.9 1/2 10.9 3.406 86.51 3.500 88.90 3.668 93.17 3.500 88.90 72 236.2 1/2 10.7 4.031 102.39 4.250 107.95 4.500 114.30 4.000 101.60 84 275.6 1/2 10.9 4.523 114.88 4.750 120.65 5.000 127.00 4.500 114.30 84 275.6 1/2 9.7 5.040 128.02 5.200 132.08 5.563 141.30 Base Pipe Holes Holes Hole Hole Screen Coupling Per Per Size Open Area inches mm foot meter inches sq.in./ft inches mm inches mm 4.500 114.30 84 275.6 1/2 9.7 5.040 128.02 5.000 127.00 5.000 127.00 96 315.0 1/2 10.0 5.530 140.46 5.563 141.30 5.500 139.70 96 315.0 1/2 9.1 6.040 153.42 6.050 153.67 6.625 168.28 120 393.7 1/2 9.4 7.187 182.55 7.390 187.71 7.000 177.80 132 433.1 1/2 9.8 7.570 192.28 7.656 194.46 7.625 193.68 144 472.5 1/2 9.8 8.211 208.56 8.500 215.90 8.625 219.08 156 511.8 1/2 9.4 9.228 234.39 9.625 244.48 9.625 244.48 168 551.2 1/2 9.1 10.248 260.30 10.625 269.88 10.750 273.05 180 590.6 1/2 8.7 11.395 289.43 11.750 298.45

Wire Wrapped Base Pipe Pre-Packed Screen The Pre-Packed Screen has been integrated with the latest Wire Wrap technology to provide outstanding durability and performance. This screen assembly consists of an inner perforated base pipe, jacketed by two Wire Wrapped Screens. The annulus between the two jackets is packed with a high quality filter media. The gauge of the inner and outer jackets is determined by the size and type of filter media. The gauge should be equal to half of the smallest diameter of the filter media. The filter media is chosen based on the formation sands that are to be controlled. The standard filter media used is high quality gravel pack silica sand, fully curable resin coated reseived gravel pack sand or ceramic beads are also available. Industrial vibrating machines are used in conjuction with careful loading of the filter media to ensure proper compaction and even distribution. High intensity light is used during the inspection process of each Pre-Packed Screen. Each assembly is 100% void free. Pre-Packed Screens are an economical alternative that may be used to complete vertical or horizontal wells when a conventional gravel pack is not feasible. Base Pipe Holes Holes Hole Hole Per Per Size Open Area Screen Annular Thickness inches mm foot meter inches sq.in./ft inches mm inches mm 1.900 48.26 84 275.6 3/8 13.0 3.406 86.51 0.492 12.50 2.375 60.33 96 315.0 3/8 11.8 4.031 102.39 0.567 14.40 2.875 73.03 60 196.9 1/2 10.9 4.523 114.88 0.559 14.20 3.500 88.90 72 236.2 1/2 10.7 5.040 128.02 0.505 12.83 4.000 101.60 84 275.6 1/2 10.9 5.530 140.46 0.504 12.80 4.500 114.30 84 275.6 1/2 9.7 6.040 153.42 0.500 12.70 5.000 127.00 96 315.0 1/2 10.0 7.187 182.55 0.829 21.06 5.500 139.70 96 315.0 1/2 9.1 7.570 192.28 0.765 19.43 6.625 168.28 120 393.7 1/2 9.4 8.211 208.56 0.512 13.00 7.000 177.80 132 433.1 1/2 9.8 9.228 234.39 0.829 21.06 7.625 193.68 144 472.5 1/2 9.8 10.248 260.30 1.019 25.88 8.625 219.08 156 511.8 1/2 9.4 11.395 289.43 1.084 27.53 9.625 244.48 168 551.2 1/2 9.1 12.415 315.34 1.084 27.53 10.750 273.05 180 590.6 1/2 8.7 14.073 357.45 1.339 34.01

Wire Wrapped Base Pipe Thin-Packed Screen In situations where it is necessary to maximize the base pipe diameter, minimize the screen assembly diameter, and maintain a large inflow area, Variperm's Thin-Packed Screens meets the challenge. This screen consists of an inner perforated base pipe covered with a thin inner stainless steel Wire Wrapped jacket, covered by a larger diameter Wire Wrapped jacket. The annular thickness is kept to a minimum. The gauge of the inner and outer jackets is determined by the size and type of filter media. The gauge should be equal to half of the smallest diameter of the filter media. The filter media is chosen based on the formation sands that are to be controlled. The same manufacturing procedures and principles used in the fabrication of Pre-Packed Screen are used here. Also, all Variperm sand control products have high mechanical strength. Procedures have been developed that limit the stresses introduced to the weld affected area of each assembly. Thin-Packed Screens can be combined with a gravel pack to ensure the successful completion of a gravel packed well. If voids exist within the gravel pack its usefulness is compromised. These screens act as a backup and are effective where a gravel pack void would otherwise limit the success of the completion. The minimized outer diameter of the Thin-Pack allows the annulus area of the gravel pack to be maximized. Base Pipe Holes Holes Hole Hole Per Per Size Open Area Screen Annular Thickness inches mm foot meter inches sq.in./ft inches mm inches mm 1.900 48.26 84 275.6 3/8 13.0 2.870 72.90 0.220 5.59 2.375 60.33 96 315.0 3/8 11.8 3.345 84.96 0.220 5.59 2.875 73.03 60 196.9 1/2 10.9 3.845 97.66 0.220 5.59 3.500 88.90 72 236.2 1/2 10.7 4.470 113.54 0.220 5.59 4.000 101.60 84 275.6 1/2 10.9 4.970 126.24 0.220 5.59 4.500 114.30 84 275.6 1/2 9.7 5.470 138.94 0.220 5.59 5.000 127.00 96 315.0 1/2 10.0 5.970 151.64 0.220 5.59 5.500 139.70 96 315.0 1/2 9.1 6.470 164.34 0.220 5.59 6.625 168.28 120 393.7 1/2 9.4 7.595 192.91 0.220 5.59

Perforated Tubing And Casing Systems Variperm's perforated Liner Systems are a proficient cost effective way of exposing the geological formation to atmospheric pressure. Multi Spindle Drill Presses are used to produce liners which have a standard open area of 3%. Both the number of perforations per foot and the hole size are adjustable to provide different open areas which may be required by specific applications. The integrity of the liner is not compromised when it is perforated using circular holes to achieve the required inflow area. The stress concentration factors introduced into the liner as a result of the perforation process are limited when circular holes are used. As a result, the residual stresses caused by the bending and torsional loading which occurs during the installation of the liner are minimized. Every perforated casing and tubing joint is put through a comprehensive deburring process. Every hole is visually inspected and cleaned of burr material. Variperm understands the importance of completing a well with a clean liner. Circulation Systems can accommodate a sluffing formation to allow accurate placement of perforated liners. Variperm's professional support staff are available to assist in the field when a Circulating System is required. Base Pipe Holes Holes Hole Hole Percentage Per Per Size Open Area Open Area inches mm foot meter inches sq.in./ft sq.cm/m % 1.900 48.26 24 78.7 3/8 2.65 56.1 3.701 2.375 60.33 30 98.4 3/8 3.31 70.1 3.701 2.875 73.03 18 59.1 1/2 3.53 74.8 3.261 3.500 88.90 24 78.7 1/2 4.71 99.7 3.571 4.000 101.60 24 78.7 1/2 4.71 99.7 3.125 4.500 114.30 30 98.4 1/2 5.89 124.7 3.472 5.000 127.00 36 118.1 1/2 7.07 149.6 3.750 5.500 139.70 36 118.1 1/2 7.07 149.6 3.409 6.625 168.28 42 137.8 1/2 8.25 174.6 3.302 7.000 177.80 42 137.8 1/2 8.25 174.6 3.125 7.625 193.68 48 157.5 1/2 9.42 199.5 3.279 8.625 219.08 54 177.2 1/2 10.60 224.4 3.261 9.625 244.48 60 196.9 1/2 11.78 249.4 3.247 10.750 273.05 66 216.5 1/2 12.96 274.3 3.198

Variperm Canada Limited is a 100% Canadian owned and operated company offering high quality Wire Wrapped Screens and Perforated Liner Systems to both the Canadian and International Oil and Gas Industries. Variperm is able to design, manufacture and implement "fit for purpose" solutions to meet the ever-changing needs of its customers. Through full control of manufacturing, Variperm is able to respond quickly to engineering changes and meet tight delivery schedules. Variperm's enthusiasm and high standard of customer service is provided to all customers, no matter how large or small they may be. Proudly Canadian The All Welded Wire Wrapped Screen combines high strength and superior corrosion resistance for unsurpassed durability. High quality 304L and 316L stainless steels are the standard materials used in the manufacture of all Variperm's screen products. Each individual rib wire is electric resistance welded to the wrap wire at all points of contact. This process develops a strong robust screen with an unobstructed outer surface that allows fluid and particulate to flow freely around and over the screen. Slot size is permanent and accurate. Variperm's engineering and design team are experts in the field of sand control and hole consolidation. The design team works side by side with manufacturing personnel to provide high quality products. At Variperm's facility, quality control is an important aspect of the fabrication process. Each individual who is involved in the fabrication of a Variperm product takes pride in his or her part of the process. The finished product will not be released for shipment until all inhouse and customer specifications are met. sandcontrol@variperm.com #10, 3424 26 th Street N.E. Calgary, Alberta T1Y 4T7 (403) 250-7263 phone (403) 250-9695 fax