DC Ammeter Shunts. General Information. Leads. Installation. Characteristics of Manganin Shunt Cold Formed Stress Relieved

Similar documents
AC-DC Converter Application Guidelines

Data Bulletin. Mounting Variable Frequency Drives in Electrical Enclosures Thermal Concerns OVERVIEW WHY VARIABLE FREQUENCY DRIVES THERMAL MANAGEMENT?

POWER AND VOLTAGE RATING

Digital Energy ITI. Instrument Transformer Basic Technical Information and Application

Calibrating DC Shunts: Techniques and Uncertainties

Shrinking a power supply and the challenge to maintain high reliability.

ST Series POWER SUPPLIES USER INSTRUCTIONS

The Effect of Forced Air Cooling on Heat Sink Thermal Ratings

BB-18 Black Body High Vacuum System Technical Description

THERMAL DESIGN AND TEST REQUIREMENTS FOR OUTSIDE PLANT CABLE TELECOMMUNICATIONS EQUIPMENT Al Marshall, P.E. Philips Broadband Networks

CHAPTER 6 THERMAL DESIGN CONSIDERATIONS. page. Introduction 6-2. Thermal resistance 6-2. Junction temperature 6-2. Factors affecting R th(j-a) 6-2

Power Dissipation Considerations in High Precision Vishay Sfernice Thin Film Chips Resistors and Arrays (P, PRA etc.) (High Temperature Applications)

Calculating Heat Loss by Mark Crombie, Chromalox

RMS Power. The Meaning of Average

OPERATING YOUR JEN-KEN GLASS KILN

ARCO Electric Products Installation and Maintenance Manual Low Voltage Automatic Power Factor Correction Capacitor Systems 2013

SAFETY PRECAUTIONS AND INSTRUCTIONS FOR USE OF TECHNICAL INFORMATION

Current and Temperature Ratings

Carbon Cable. Sergio Rubio Carles Paul Albert Monte

12S, 14S, 15S Series. Time Delay Relays and Sequencers. Time Delay Relays and Sequencers. Features and Benefits. Switch Actions and Configurations

Temperature Rise Calculation Software Tutorial. In Accordance with the Calculation Method to IEC 60890

Bussmann series Third rail fuse links application guide. Leadership in fusible circuit protection solutions

Specifying a Variable Frequency Drive s

Submit shop drawings for equipment provided under this section Shop drawings shall indicate:

Phone: Fax: Web: info@clrwtr.com

Type SA-1 Generator Differential Relay

DC/DC power modules basics

PSR The compact range Description

Comparative study for cables and busbars

Current transformers (CT) & Shunts

Bourns Resistive Products

Pulse Withstanding Thick Film Chip Resistor-SMDP Series. official distributor of

STRATO LED Drivers 70W, Single output

WINDING RESISTANCE TESTING

We will discuss common industrial applications with guides for the proper use of electric motors on these.

Kit Watt Audio Amplifier

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

DIRECT CURRENT GENERATORS

ELECTRIC HEATER COMPANY Operating and Maintenance Manual For Immersion Heating Elements

THE KW107 SUPERMATCH ATU manual, courtesy of Barry G0DWZ

Bussmann. All-In-One Module. Bussmann Power Module Switch. How to configure Part Numbers: Step 1: Select Switch Amperage 1

High Speed Fuses. High Speed Fuses

6/14/02 Chapter 14: Use of Electrical Test Equipment 1/20

In today s world of wireless communications

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

3.0 CHARACTERISTICS. AR Auxiliary Relay High Speed, High Threshold C

Application Note TMA Series

Insulation Resistance Testing of Low Voltage Cables in the Field

The Importance of the X/R Ratio in Low-Voltage Short Circuit Studies

EXTENDING THE LIFE OF POWER FACTOR CAPACITORS

PHOTOVOLTAIC SYSTEM CONTROLLERS SUNSAVER MODELS INCLUDED IN THIS MANUAL SS-6 / SS-6L SS-10 / SS-10L SS-10-24V / SS-10L-24V SS-20L SS-20L-24V

Manual Ranging MultiMeter

SOLAR PV STANDARD ELECTRICAL PLAN Microinverter Systems for Single Family Dwellings

MCR1900 Media Converter 19-Slot Chassis

Everline Module Application Note: Round LED Module Thermal Management

Fan Basics and Selection Criteria (How to Use)

GS Semiconductor Fuselinks. GE Power Controls. GS Semiconductor fuselinks

Charge Regulator SCR 12 Marine

Bolted contact switches. Pringle switches

Low and High Voltage Power Supplies

UMEC International Corporation

The Charging System. Section 5. Charging System. Charging System. The charging system has two essential functions:

CATHODIC PROTECTION TRANSFORMER RECTIFIER (CPTR)

Features. Applications

AutoRanging Digital MultiMeter

Current Limiting Power Resistors for High-Power LED Module Lighting Applications

INTEGRATED CIRCUITS DATA SHEET. TDA7000 FM radio circuit. Product specification File under Integrated Circuits, IC01

P O W E R C A P A C I T O R A S S E M B L I E S

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

TC Grounding and Bonding for Telecommunications Systems

Iron Powder Cores for Switchmode Power Supply Inductors. by: Jim Cox

Thyristor-controlled power supplies and battery chargers

Copper and Aluminum busbars

VOLTAGE REGULATOR AND PARALLEL OPERATION

Experiment #4, Ohmic Heat

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

BERTHOLD ELECTRIC GENERATOR CONNECTION CABINET

Current Transformers

APPLICATION NOTES. Bimetal Disc Thermostat. Operating Principle

6 ELECTRICAL PARAMETERS

RADIANT PLASMA 4700 Plasma Spark Generator

Generator Stator Protection, under/over voltage, under /over frequency and unbalanced loading. Ramandeep Kaur Aujla S.NO

Variable Frequency Drives - a Comparison of VSI versus LCI Systems

VIBRATION MONITORING OF FANS INSTALLED IN ROAD TUNNELS

Line Reactors and AC Drives

Effects of AC Ripple Current on VRLA Battery Life. A Technical Note from the Experts in Business-Critical Continuity

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE

High-ohmic/high-voltage resistors

Objectives 200 CHAPTER 4 RESISTANCE

CS4525 Power Calculator

Power Supply Cables and Connectors

Diesel Engine Driven Generators Page 1 of 6

Battery Power Inverters

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

MP-4000 Alarm List (Software version or later)

Varactor Diodes. Introduction. Key Electrical Parameters. Reverse Breakdown Voltage and Reverse Leakage Current APPLICATION NOTE

Buck - Boost Transformers

Forms of Energy. Freshman Seminar

Low Voltage Disconnect Switches. NFPA79 and UL508A Industrial Machinery Operating Handle Requirements White Paper

Transcription:

General Information CSI shunts are designed for use with 50 or 100 millivolt measuring instruments, calibrated in terms of the ampere ratings of the shunt. The accuracy of our shunts is better than ±1/4% of the rated value and the temperature coefficient is ±0.000015. It is important that the resistance be constant under different temperature conditions. It is usually assumed that the maximum temperature will be about 80 C and the usual range is 40 60 C. For continuous operation, it is recommended that shunts are not run at more than two-thirds (2/3) the rated current under normal conditions of use as per IEEE standards. If the shunt is used in an AC or pulse current environment make sure that the highest pulse current does not exceed the recommended two-thirds, the rated current for continuous operation. In this case the average millivolt reading using a rms meter will be proportional with the duty cycle of the AC current. Installation By definition, a shunt is a resistor, and will generate heat with passage of current. Because of this, the resistance blades of the shunt should be mounted in a vertical position to promote free convectional flow of air. Where this mounting position is impractical and in installations where the shunt is in a confined location forced air cooling should be provided. Under no condition should the manganin shunt strip be allowed to surpass 145 C, as this will cause a permanent change in resistance. Shunts should be installed to protect them from damage by thermal expansion forces in the connecting bus bars or by short circuit forces. It should be recognized that shunts are inherently weaker than their current connections and that special flexibility may be needed at times. Where possible all shunts should be connected in the grounded side of the line. Portable type shunts, with an insulating base, when used on circuits above 750 volts should be mounted in the grounded side of the circuit. Where more than one bus bar is to be connected to each end of a single terminal shunt, these bars should be distributed as equally as possible on each side of the shunt terminals. Leads In some applications it is not feasible to mount the shunt close enough to the instrument to permit the use of the standard lead lengths. If longer lead lengths are necessary, the additional drop in the leads must be taken into consideration when ordering analog instruments. Characteristics of Manganin Shunt Cold Formed Stress Relieved % CHANGE OF RESISTANCE + 0.02 0-0.02-0.04-0.06-0.08-0.10 TEMP. C 10 20 30 40 50 60 70 80 90 100 Temperature coefficient of resistance: ± 15ppm/ C. 18

Shunt Selection Guide Definition: Instrument Shunt is a particular type of resistor designed to be connected in parallel with the measuring device to extend the current range beyond some particular value for which the instrument is already complete. Any shunt by definition is a resistor and will generate heat with the passage of current. Shunt ratings are established by finding the power required to achieve a specified manganin temperature rise in free air at certain predetermined conditions. When operating conditions are significantly different from the rating conditions, the shunt should be de-rated or up-rated accordingly to keep the manganin temperature within reasonable limits in order to prevent premature failure, reduced reliability, reduced rated accuracy or causing permanent change in resistance. CSI s standard shunts are rated to meet IEEE Standard Requirements for Direct Current Instrument Shunt. IEEE 6.2 Current Ratings: Selection of ratings should be based on operation at a normal current of 2/3 the rated value. Ratings are based on mountings in accordance with Reference Test Conditions: Reference Temperature: 25 C (±2 C) Position: Current terminals and resistance blades, vertical, allowing free air circulation Connections: Tightly bolted to current bus using all terminal slots and specified depth of blade insertion or tightly bolted to lugs with cables or proper cross-section Since a shunt is essentially part of a bus-bar assembly, it depends on the structure to conduct away a major portion of the heat generated within the shunt and then to radiate this heat. It is important, therefore, that these connecting buses be of ample size and properly attached to the shunt. Design Considerations When trying to find the correct shunt rating to specify for a given application, there are four things to take into account: A) Duty continuous, intermittent or surge B) Ambient elevated temperature or high altitudes C) Temperature rise normal or limited D) Environment grouped, enclosed, forced air E) Combinations of A through D Although each of these conditions will be considered separately, any combination of them may exist in a specific case. When this happens it will be necessary to use more than one of the following sections to arrive at the correct rating. 19

Duty For duty which is less than continuous, a shunt need not be rated as high as a straight calculation based on resistance and voltage or current would indicate. If, for instance the shunt is repeatedly energized for a short period (not to exceed 5 minutes) a conservative rating may be obtained as follows: K1 = D P puls = P max / K1 P max = P rated x 0.66 P max = maximum continuous power P rated = catalog rated power P puls = maximum pulsating power where D is the ratio of ON time to the total period. For surge and pulse service a different approach must be used. In these cases it is necessary to provide enough thermal mass to absorb the energy to be dissipated and be sure that the construction of the shunt is adequate to accommodate the peak power. Therefore, it is recommended that a complete description of the pulse/surge wave shape or circuit constants and operating conditions be submitted to the CSI Engineering Department for the selection of a suitable shunt. Example: A 800 Amp 500mV shunt is energized for 15 seconds of each minute. D = 15 / 60 = 0.25 and K1 = 0.25 = 0.5 thus, P rated = 800 x 0.05 = 40 watts P max = P rated x 0.66 = 40 x 0.66 = 26.4 watts P puls = P max / K1 = 26.40 / 0.5 = 52.8 watts therefore this shunt can be loaded up to 910 Amps. Ambient If the ambient temperature of the area in which the shunt is to operate exceeds the ambient Reference Test Conditions, a de-rating factor must be applied to prevent the manganin temperature from going above the safe limit of 125 C. The following formula may be used to find the de-rating power. P out = P max x (1-T/A) P max = P rated x 0.66 where T is the difference between the rated and operating ambient temperatures, A is the rise allowed above the rated ambient and Pmax is the Pout at 25 C. Example: If a 150 Amp 50 mv shunt is to operate in a 100 C ambient, what is the maximum load? 100 C is 75 degrees above the ambient, so T = 75 C, and the rated rise A is 100 C. Therefore: P out = P max x (1-75 / 100) = P max x 0.25 P max = 0.66 x P rated = 0.66 x (150 x 0.05) = 4.95 watts P out for an ambient of 100 C is P out = 4.95 x 0.25 = 1.23 watts, 60 Amps will be the maximum load. 20

Temperature Rise In many cases it is desirable to limit the temperature rise of a shunt for increased accuracy and stability or to protect other equipment near it. A satisfactory de-rating factor K2 may be obtained from: K2 = 1 - t / 125 where t is the difference between the rated and the newly imposed rise limit. Example: Suppose it is necessary to limit the temperature rise of a shunt type LC800 Amp 50 mv to 75 C. What is the maximum safe load? t=125-75=50 K2=1-50 / 125=0.6 P rated x 0.66 = 26.4 watts = P max at 25 C K2 x P max = 26.6 x 0.6 = 15.84 watts; therefore 510 Amps represents the maximum safe load. Environment 1. Space requirement Any shunt by definition is a resistor and hence will generate heat with passage of current. Shunts should be mounted in a location where there is free circulation of air to carry away the heat generated. Shunt blades should be mounted in a vertical position to promote free airflow. If there is not enough natural convection, forced air cooling should be applied. 2. Enclosures Shunts are frequently mounted in enclosures for protection from the surroundings or to safeguard operators and personnel. If the unvented enclosure is large in proportion to the amount of energy to be dissipated, there is no need for concern. If the power density is greater than 1/4 watt per square inch of enclosure surface, provision must be made for cooling air using vents or fans. Note: Call CSI Engineering Department for mathematical formulas and examples regarding Venting, Force air cooling, Grouping, Altitude and Combinations. Conclusion The foregoing discussions are intended as a guide to the design engineer in the selection of the correct shunt for application and should be adequate under normal circumstances. Since it is often difficult to determine what the shunt will actually see in service, it is wise to use a conservative approach in all cases. If unusual conditions exist or if the engineer is unsure of the application, CSI Engineering Department is always ready to help in the selection of shunt for the case at hand. 21

Custom Applications Give us your specs and we ll give you a solution for your application. We invite your inquiry for special shunts. See Questionnaire on our Products & Services page. Other Fine Products Knife Switches Heavy Duty Knife Switches 100% Electrolytic Copper Ratings up to 20,000 amperes and 600 volts DC/AC Construction styles: Front or Back connected Fusible or non-fusible. Complete Engineering Services for special designs Telecom Fused Disconnects Fused Disconnects Type TPL-61-6001: Ratings up to 600A and 145Vdc will hold fuse types: Bussmann TPL or Littelfuse L17T Type DF-61-6001: Ratings up to 600A and 60Vdc will hold fuse types: Bussmann TPL or Littelfuse L17T Switch Fused Disconnects Type TPL-62-6001: Two TPL-61-6001 mounted on a common base with a switch mechanism. Ratings up to 600A and 145Vdc Type TR-22-6001: Two DF-61-6001 mounted on a common base with a switch mechanism. Ratings up to 600A and 60Vdc 22