MC Switch user manual

Similar documents
LEDPAR64 USER MANUAL

Acrobat. user manual

Mania SCX500. user manual

DP-DMX20L 4 CHANNEL DMX DIMMER PACK MODE MENU DISPLAY. OUTPUT: 10A/CH, TOTAL 20A Max. DMX CHANNEL RECEIVE TOTAL DMX CHANNEL DIMMER / SWITCH

VIEW. SLX300 SpeakerLinX IP Zone. Amplifier Installation and Setup Guide. AVoIP

INFRARED QUARTZ WALL HEATER

2XWSXWFKDQQHOV 3KDVH &+ CH 2 &+ CH 4 &+ CH 6 L1 X X L2 X X L3 X X

Atomic user manual

High PoE Midspans NPD-6001A NPD-9501A. en Installation Manual

MultiDim MKII V.2 ORDERCODE 50386

LIEBERT VNSA Installation Sheet

ATS Overhead Table Shelf System INSTRUCTION MANUAL

19 LED Tube Controller ORDERCODE 41003

MANUAL ENGLISH. Ordercode: Highlite International B.V. Vestastraat EX Kerkrade the Netherlands

AMERBRITE UNDERWATER WHITE LED POOL LAMP

Agilent 87421A/87422A Power Supply

VK-250 WARRANTY REGISTRATION FORM

MCA Series Multi-Channel Amplifiers. Operation Manual

TABLE OF CONTENTS. Hurricane 1300 User Manual 2 Rev. 4

PS4-24 OWNERS MANUAL 24 VAC 90 WATT WALL MOUNTED CCTV POWER SUPPLY

Achat 115MA full-range speaker. user manual

USER MANUAL Stand Alone Power Supply PSQ 2909 / PSQ 3909 / PSQ 4909 PSQ 2920 / PSQ 3920 / PSQ 4920

12-Volt 10-Amp Regulated Power Supply

Meaco 30L and Meaco 40L dehumidifier instruction manual

Fixture One Power Cord One User Manual One Omega Bracket One DMX Cable - One

SL STRIP 400 TW LED Luminaires

Sunstrip Active DMX ORDERCODE 30710

HP UPS R1500 Generation 3

Model 1756 Test Lead Kit

EPM3. Phase Sequence and Motor Rotation Tester. Users Manual

Disabled Toilet Alarm. Contractor Pack. Installation & Operating Instructions

PROFESSIONAL WIRELESS DMX CONTROLLER USER S MANUAL EWDMXSYSTEM

MIC-WKT and MIC-WKT-IR

Power supply unit Model: PAC-SC50KUA

Solar Home System. User Manual. AEH-SHS01-10W2L Solar Home System 2 Lamps

Bubble King. User Manual

Warning! To prevent or reduce the risk of electrical shock or fire, do. Caution! There are no user serviceable parts inside this unit.

LED BAR 126 / 252 RGB. Owner s Manual LED BAR RGB

USER INSTRUCTIONS FOR GET PORTABLE 12k BTU AIR CONDITIONER MODEL No. GPACU12HR

HP Port Switches Quick Setup Guide

Light Source User Guide

Rain+Birdt. Simple To Set Timer (SST) Setup & Operation Instructions. English RAIN BIRD ( ) or visit

MA-4150 ORDERCODE D6149 Highlite International B.V.

TABLE 1. Rugged cast aluminum alloy casing,celcon waterways with nichrome parts White (unless stainless steel housing)

Electrical Safety Plugs What are the different types of plugs? Extension Cords What are some potential hazards involving extension cords?

ComPar KIT 1 & 2 DMX LED light set

LED Par 56 Short DMX ORDERCODE 42421

BroadBand PowerShield. User Manual

OASIS-PLUS 120V READ ALL INSTRUCTIONS BEFORE OPERATING READ ALL INSTRUCTIONS BEFORE OPERATING OZONE IS A POWERFUL OXIDIZER AND MUST BE USED WITH CARE

LED Par 56 Ultra Bright RGB Black ORDERCODE Polished ORDERCODE 42451

Snapshot. LEDrain 38 USER MANUAL. Ok on Dimmer. Outdoor OK. Sound Activated. DMX/Master/Slave. 115V/230V Switch. Replaceable Fuse.

±15 V Current-Limited Power Supply

LED WALL WASHERS SPECIFICATIONS & INSTALLATION GUIDE

16/32 Channel 1U Rack Mount CCTV Power Supply

MANUAL ENGLISH UBR-180BT Ordercode: D1258

User Guide. HDMI Active Cable Extender. DVI-7370c

Product and functional description

FT-100 Fire Training Fog Machine User Manual English

HOUSING QUALITY STANDARDS (HQS)

USER MANUAL. 914 Power Amplifier MODEL: P/N: Rev 1

IntelliBrite Controller (For IntelliBrite Pool, Spa and Landscape Lighting Fixtures) Installation and User s Guide

INSTALLATION AND OPERATION INSTRUCTIONS - (LOW FLOW MODELS) (Before installation, compare electrical needed for the model of heater selected)

OPERATOR S MANUAL 18 VOLT, 1 HOUR CHARGER

Operating Instructions

Draper Low Voltage, Remote Control, Serial and Network Wiring Guide

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.

Tone Hammer 500. Owners Manual. Manual Version 1.0

PRELIMINARY MANUAL STAGE COLOR 48. Preliminary User Guide. Official version will follow soon on: TABLE OF CONTENTS

INSTALLATION GUIDE. Card Reader & Controller with KIM Swipe Reader for Solitaire 850 / 950 / 850L Learnlok PK2930

LevelOne IFE Port PoE + 1-Port TP Industrial Fast Ethernet Switch User Manual

ANTENNA DISTRIBUTION SYSTEM USER'S GUIDE

Online UPS. PowerWalker VFI 1000R/1U

Warning! To prevent or reduce the risk of electrical shock or fire, do. Caution! There are no user serviceable parts inside this unit.

STAGE SETTER-8. User Instructions. Elation Professional

HP Port and 48-Port Switches Quick Setup Guide

=============================== WARNING

Power Supply Guide Version 1.0 for D-Show

OEM Manual MODEL 2350 ELECTRONIC DUAL CYLINDER SCALE

Safety & Environmental Protection Services Guidance Note

ORLAND FOLLOW PR-1211

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

PT-6000 Power Tower INSTALLATION MANUAL SPECIFICATIONS

Trade of Electrician. Three-phase Distribution Boards And Socket Circuits

Square D Clipsal DIN-Rail Four-Channel Auxiliary Input Unit

PEDAL POWER. User s Manual

Troubleshooting Guide, Freedom and Fleet Power Inverter/Chargers

EtherNet-RS232/485. London Electronics Limited. Ethernet to RS232 or RS485 data converter. Connection details and general information

LOXONE 12 Channel Amplifier

Model PS-4001 Power Supply User Instructions

HID H4 BI-XENON FITTING GUIDE. Carefully read the following notes before starting work.

3 WATT LED SPOTLIGHT Model No. SLM

IMPORTANT SAFETY INSTRUCTIONS

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Dotz Bar 1.4. User Instructions

Active Speaker System LX523 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Active Speaker System with remote input LX523. User Manual & Installation Guide

Operating Instructions

Mini-led spotlight with magnetic base

2 Mega-Pixel PoE Plus Speed Dome Internet Camera ICA-HM620. Quick Installation Guide

Installation and Operation Guide PD4600 Series Converter Replacement

INSTALLATION GUIDE LOW VOLTAGE TRANSFORMER

Transcription:

MC Switch user manual

Measurements are expressed in millimeters. 75 155 258 323 355 114 120 78 50 102 143 109 2004 Martin Professional A/S, Denmark. All rights reserved. No part of this manual may be reproduced, in any form or by any means, without permission in writing from Martin Professional A/S, Denmark. Printed in China. P/N 35000141, Rev. D.

CONTENTS 1. Introduction.............................................. 1 Safety information............................................ 1 Unpacking.................................................. 2 2. Installation................................................ 3 AC power................................................... 3 Connecting fixtures........................................... 4 Installation/mounting.......................................... 5 Connecting the Control Box..................................... 5 3. Operation................................................. 6 4. Fuses..................................................... 7 115-120 V, 60 Hz model fuses................................... 7 220-240 V, 50 Hz model fuses................................... 7 Replacing the mains fuse....................................... 7 5. Specifications............................................ 9

1. INTRODUCTION Thank you for selecting a Martin MC Switch. This switching device allows you to turn on and off up to six devices. The MC Switch is ruggedly built for years of trouble-free use. Setup and operation are simple; please read this manual before setting up and operating the device. The MC Switch comes in two models: 220-240 V, 50 Hz 115-120 V, 60 Hz The model that you have is indicated on the serial number label on the fixture. An MC Switch consists of a Power Box and a Control Box (remote control device). SAFETY INFORMATION Warning! This product is not for household use. It presents risks of lethal or severe injury due to fire and heat, electric shock, and falls. This product is for professional use only. It is not for household use. Read this manual before powering or installing the fixture, follow the safety precautions listed below and observe all warnings in this manual and printed on the fixture. If you have questions about how to operate the fixture safely, please contact your Martin dealer. Note: Ingress protection rating: IP 20 Switch for use in Class I Appliance Number of operating cycles: 10000 times Level 3 switch Pollution degree 2 PTI 175 Rated impulse withstand voltage: 2500V 1. Introduction 1

Protecting yourself and others from electric shock Disconnect the fixture from AC power before removing or installing fuses or any part, and when not in use. Always ground (earth) the fixture electrically. Use only a source of AC power that complies with local building and electrical codes and has both overload and ground-fault protection. Do not expose the fixture to rain or moisture. Refer all service to a qualified technician. Never operate the fixture with missing or damaged covers. Protecting yourself and others from burns and fire Never use the device to power fixtures that exceed the specified maximum load. Never attempt to bypass the fuses. Always replace defective fuses with ones of the specified type and rating. Do not modify the fixture or install other than genuine Martin parts. Protecting yourself and others from injury due to falls When suspending the fixture above ground level, verify that the structure can hold at least 10 times the weight of all installed devices. Secure the device with a safety wire threaded through the side holes. Block access below the work area whenever installing or removing the fixture. UNPACKING The packing material is carefully designed to protect the fixture during shipment - always use it to transport the fixture. The MC Switch is packaged with the following: Power Box User manual Six-button Control Box remote control unit 10-metre RJ-45 cable 220-240V, 50Hz models are also supplied with 2 earthed IEC power cables and 6 IEC male plugs. 2 MC Switch user manual

2. INSTALLATION AC POWER The MC Switch comes in two models: 220-240 V, 50 Hz 115-120 V, 60 Hz The model that you have is indicated on the serial number label on the fixture. Warning Do not operate the fixture on a power supply that falls outside of these ranges. Use only a source of AC power that complies with local building and electrical codes and has both overload and ground-fault protection. For protection from dangerous electric shock, the fixture must be grounded (earthed). The AC mains supply shall have overload and ground-fault protection. Important! Verify that the feed cables are undamaged and rated for the current requirements of all connected devices before use. The: 115-120 V model comes with a hard-wired 1-meter (3.3 ft) power cable. 220-240 V model comes with two 3-meter (10 ft) power cables - one without a mains plug and the other with a 2-pin Euro plug. Installing a plug on the mains lead The MC Switch s mains lead may require a grounding-type plug that fits your power distribution cable or outlet. Consult a qualified electrician if you have any doubts about proper installation. Following the manufacturer s instructions, install an approved groundingtype plug that fits your supply. Connect the wires to the pins as listed below. The table shows some possible pin identification schemes; if the 2. Installation 3

pins are not clearly identified, or if you have any doubts about proper installation, consult a qualified electrician. Wire (EU) Wire (US) Pin Marking Screw (US) brown black live L yellow or brass blue white neutral N silver yellow/green green ground green CONNECTING FIXTURES The model that you have is indicated on the serial number label on the fixture. Warning! Do not daisy-chain additional switch packs to the power outputs of the MC Switch. 220-240 V, 50 Hz models IEC male plugs, included, must be installed on the fixture power cables. Connect the wires as shown in the above table. Consult a qualified electrician if the power cables for your fixtures are colored differently. Plug the fixtures into the power outputs on the Power Box. Warning! Each power output can supply 300 watts maximum to a fixture utilizing a halogen lamp. Do not connect higher wattage devices to the switch pack or connect more than one fixture to an output. The maximum total load on 220-240 V, 50 Hz models is 1800 watts. 115-120 V, 60 Hz models If necessary, install local plugs, or cord caps, to your lighting fixtures. Connect the fixtures into the power outputs on the Power Box. Warning! Each power output can supply 300 watts maximum to a fixture utilizing a halogen lamp. Do not connect higher wattage fixtures to the switch pack or connect more than one fixture to an output. The maximum total load on 115-120 V, 60 Hz models is 1500 watts. This means you can use 5 outputs with the maximum 300 watts load on each, or 6 outputs with 250 watts load on each. 4 MC Switch user manual

INSTALLATION/MOUNTING The Power Box can be floor mounted, bolted fast to a rack or surface, or suspended using a clamp (as in the following illustration). M10 Warning! When suspending the Power Box above ground level, verify that the structure can hold at least 10 times the weight of all installed devices. Secure the device with a safety wire threaded through the side holes. CONNECTING THE CONTROL BOX The Control Box is connected to the In socket on the Power Box using the supplied 10 m (33 ft) RJ-45 cable. The maximum length of RJ45 cable between the Control Box and the Power Box is 20 meters (66 ft). Warning! Use only an MC Switch Control Box. Do not connect an other type of remote control device or a DMX network to the Power Box. Controlling multiple MC Switches with a single remote Up to four Power Boxes can be daisy-chained to a single Control Box using additional RJ-45 cables and the In and Out sockets on successive Power Boxes. The maximum cable length between each successive Power Box in a daisy-chain is 10 m (33 ft). 2. Installation 5

3. OPERATION Each of the six power outputs can be activated or deactivated using the buttons on the Control Box. When power is on for an output the associated LED will light up. When controlling multiple Power Boxes with a single Control Box, each button will activate or deactivate the associated power output on all the Power Boxes. 6 MC Switch user manual

4. FUSES The MC Switch uses an onboard mains fuse for protection against current overload. An indication that the fuse may have blown is that when power is applied and the lamp is switched on, no light is produced. If the fuse blows repeatedly, there is a fault with the unit that requires service by a Martin technician. Never bypass the fuse or replace it with one of another size or rating. 115-120 V, 60 HZ MODEL FUSES The 115-120 V, 60 Hz model uses a 15AF mains fuse and six 4AT/250V fuses (1 per power output): 15AF fuse........................................ Martin P/N 05021018 4AT fuse......................................... Martin P/N 05020017 220-240 V, 50 HZ MODEL FUSES The 220-240 V, 50 Hz model uses a 10AH mains fuse and six 2.5AT/250V fuses (1 per power output): 10AH fuse........................................ Martin P/N 05021017 2.5AT fuse........................................ Martin P/N 05020010 REPLACING THE MAINS FUSE 1 Unplug the mains cable from the input socket. 4. Fuses 7

2 Open the fuse holder (located next to the mains power connector) with a flat-head screwdriver and remove the fuse. MAINS INPUT 115-120V, 60Hz model 220-240V, 50Hz model 3 Replace the fuse with one of the same type. The fuse rating is listed on the serial number label and in 5. Specifications on page 9. 4 Replace the fuse cover. 8 MC Switch user manual

5. SPECIFICATIONS 115-120 V, 60 Hz version (U.S.) PHYSICAL Size - Power Box (LxWxH).................. 355x155x75 mm (14x6.1x32 in.) Weight - Power Box......................................1.85 kg (4 lbs) CONSTRUCTION Housing....................................................... steel ELECTRICAL AC Power input....................................... 115-120 V, 60 Hz AC power output.................... 6 channels, max. total output 1500 watts (250 watts per channel using 6 channels or 300 watts per channel using up to 5 channels) INCLUDED ITEMS Power Box Control Box 2 m (6.5 ft) US mains cable 18AWG with US male connector (UL approved) User manual 10 m (33 ft) RJ-45 cable ACCESSORIES 15AF mains fuse.................................. Martin P/N 05021018 4AT fuse......................................... Martin P/N 05020017 ORDERING INFORMATION MC Switch 6 channel, 115-120V, 60Hz....................... P/N 90758245 220-240 V, 50 Hz version (E.U.) PHYSICAL Size - Power Box (LxWxH).................. 355x155x75 mm (14x6.1x32 in.) Weight - Power Box......................................1.85 kg (4 lbs) CONSTRUCTION Housing....................................................... steel 5. Specifications 9

ELECTRICAL Input......................................... 3-prong IEC male socket AC Power input....................................... 220-240 V, 50 Hz AC power output.................... 6 channels, max. 300 watts per channel INCLUDED ITEMS Power Box Control Box 3 m (9.8 ft) EU mains cable 3x1.0mm 2 with Euro connector 3 m (9.8 ft) EU mains cable 3x1.0mm 2 with no male connector User manual 10 m (33 ft) RJ-45 cable ACCESSORIES 10AH mains fuse................................... Martin P/N 05021017 2.5AT fuse........................................ Martin P/N 05020010 ORDERING INFORMATION MC Switch 6 channel, 220-240V, 50Hz....................... P/N 90758240 10 MC Switch user manual

www.martin.com Olof Palmes Allé 18 8200 Aarhus N Denmark Tel: +45 8740 0000 Fax +45 8740 0010