THE NEW THROUGH FLOOR LIFT

Similar documents
Galaxy Flex SECURITY THAT FITS WITH YOUR BUSINESS AND LIFESTYLE. Protect your property

Droveway ARCHITECTURAL SERVICES. Disability Access Audit. Sample Gospel Hall. 22 September For

Fire. The Fire Installers Mate. A guide to fire alarm systems design

RADAR

Installation Detailed installation instructions are provided which should be strictly followed.

nr 28 nr 68 nr 4 nr 1

The replacement or modification of existing windows shall comply with the following requirements:

(68.52) X. June 2000 Supercedes February xenex CONVENTIONAL FIRE DETECTION & ALARM SYSTEM. we business differently

Colonnade Security Pipe

conventional system operation

Fire Alarm system Installation Guide

IMPORTANT INFORMATION

EXCAVATOR SAFETY TRAINING

THE UNIVERSITY OF EDINBURGH. Alexander Graham Bell Building. King s Buildings

Bringing good things ahead

AVAILABLE TO DOWNLOAD ON THE APOLLO APP. Fire Alarm Systems Design. a guide to BS5839

FIREDEX Conventional Fire Panels

Recommendations to improve the safety of existing lifts

ACCESSIBILITY STANDARD

Standard the the Raising

V1504 Vertical Platform Lift OWNER S MANUAL

ATM SECURITY ATM CASSETTE GUARD KEY FEATURES. High security Rapid installation Simple operation Time locks & delays Proven track record

Fire Resistant Systems

Troubleshooting Guide for Jacks Down LED Lights

GUARDIAN REFUGE & EMERGENCY VOICE COMMUNICATION SYSTEMS

ACCESS AUDIT OF WESTPORT HOUSE

Heavy Metro Systems Light Rail Systems Automated Metros APMs Airport Link/City Shopping New & Retrofit Installations. w w w. platformscreendoors.

CHANGES IN NFPA 72 NATIONAL FIRE ALARM CODE

THE UNIVERSITY OF EDINBURGH, Alexander Graham Bell Building, King s Buildings,

Disabled Access Guide

3M Scotch-Weld EPX Two-component structural adhesives and applicator guns

COMMONLY USED RESIDENTIAL BUILDING CODES

PRODUCTS PRODUCTS ABOUT US.

CITY AND COUNTY OF DENVER POLICY DENVER FIRE DEPARTMENT SUBMITTAL OF CONVEYANCE INSTALLATION/ALTERATION PLANS

FIRE ALARM SYSTEM TECHNICAL SPECIFICATIONS Page 1 of 10

Conventional Fire Detection and Extinguishant Control System Specification

Customer Access 1 Checklist for Banks, Financial and Legal Services

Containment Solutions

Quadrant Shower Enclosure. Telephone Cleaning. All chrome surfaces should be cleaned using a clean damp cloth.

Automatic Sliding Door Systems

CITY OF PHILADELPHIA DEPARTMENT OF LICENSES AND INSPECTIONS ANNUAL CERTIFICATION FOR FIRE ALARM SYSTEMS

06 / Optional components. MAXDATA PLATINUM Server-Rack PLATINUM. [Product Guide]

Guide to Safety Edge Systems

Water Leak 1: Intrusion Policy

39HQ Airovision Air Handling Units

Smoke detector 500 Series The art of invisible fire detection

The KONE Motala 2000 platform lift suits the architecture of any building, thanks to the wide range of car and shaft design options.

ATTACHMENT TO NOTICE TO FIXED GUIDEWAY SYSTEM VEHICLE SUPPLIERS REQUEST FOR INFORMATION (RFI 001)

PLAN REVIEW GUIDE FOR FIRE ALARM

Building Control Guidance Note

MONORAIL. Scomi Rail THE REVOLUTION OF URBAN TRANSIT. A smooth ride quality. Higher passenger capacity. Energy efficiency. Lower operating costs.

DUOTOUR WITH SLIDING DOORS OPERATING MANUAL

LED LEONARDO 120 W. LED Fresnel SPOTLIGHT White light, either Tungsten or Daylight balanced Correlated Color Temperature

Emergency Voice Communication Systems EVCS Network 8 Data Sheet

SECURITY SYSTEM MANUAL

V1504 Vertical Platform Lift OWNER S MANUAL

FLOOR INDICATORS CATALOGUE

EMERGENCY LIGHTING - UCL GENERAL DESIGN GUIDANCE

UBC Technical Guidelines Section Edition Secure Access: General Standards Page 1 of 7

Fire Safety In High Rise Building

The complete answer to secondary glazing. High performance secondary glazing solutions for new and refurbished buildings

STARKSTROM. clinical pendants. Excellence & Innovation in Medical Engineering

Sound Engineering for 60 Years EmerCall Disabled Refuge and Fire Telephone System

TSA Conference Reducing the Risk of Fire to the Vulnerable Person through Telecare. London Fire Brigade

8900 EMR (WITH DETECTOR)

Emergency Voice Communication Systems

Hotel Accessibility Pack

Floor-Concealed Door Closers with Electromagnetic Hydraulic Hold Open DORMA BTS80 EMB

6mm Two Door Offset Quadrant

BESPOKE SOLUTIONS IT S IN THE FINISH. Building Solutions Automotive Industry

INSTRUCTION MANUAL HYDRAULIC GATE TRANSMISSION SYSTEM ECO240-ECO360

Ch. 58 DIVISION D-O 34 CHAPTER 58. DIVISION D-O ORDINARY COMMERCIAL, INDUSTRIAL, OFFICE OCCUPANCY GROUP CONSTRUCTION TYPE MAXIMUM STORY HEIGHT

rehau agila PassiVhaus door system description

The BASA Guide to the ISO Classification of Sealants for Building Construction

Hygienic Doors for the Healthcare Sector

BS5839 Part 1:2002 Overview

BLADE S-MAX Cabinet for Blade Server

Core & Shell Construction. Rules and Regulations

CATALOGO PRODOTTI PORTONI INDUSTRIALI COIBENTATI

Accessibility Design Advice

Strategies to Promote Accessible Marketplaces and Inclusive Workplaces

FLOOR INDICATORS CATALOGUE 2007

Accessible Toilets. A unisex facility should have its own entrance. It should not be entered from a single sex facility.

Conceptual Design and Analysis in Autodesk Revit Architecture 2011

PHA 2000 PHB 3000 EXIT PAD

ISSUE 2. Installation Guide

Fire Policy and Procedures. Cañada Blanch Spanish School

Automatic Door Selection Guide

IN00419 (rev A) Aqua 6 Glide Quadrant and Off-set Quadrant Enclosure

Electronics Ltd. Presenting. Power, Intelligence... with a sense of feeling

Guide to Gate Safety Legislation & the Machinery Directive. In Association with:

Fire Alarm Engineering Best Practices. CFAA NCA Technical Seminar 2014

Ecopaint Robot Painting Station

Guidance on loft conversions in two-storey houses

Elegance SC. Solar Control

I-Line - Snap-On Feature

Curved Quadrant Instruction Manual

Gen4 Intruder Alarm Panels SIMPLY SECURE. For Residential & Small Commercial Applications

Permissible ambient temperature Operation Storage, transport

Solar Panel Installations

Transcription:

THE NEW THROUGH FLOOR LIFT Pollock Lifts 22 Woodburn Road Tel.: 0044/2893/368167 Carrickfergus Fax: 0044/2893/368167 BT38 8PX E-mail: info@pollocklifts.co.uk UK - 1 -

THE NEW THROUGH FLOOR LIFT All aspects of the New Pollock Through Floor Lift have been designed with the objective of providing the existing standard and optional features that benefit the user whilst designing in new features and improvements that will be attractive to the customer. Standard Features include: In car lowering (Hydraulic). Interior light & controls with time out circuit. Key switches (Ground or 1 st Floor). Alarm Call stations Smallest footprint on the market. Fire response system. CE compliant. Optional Features include: In-car lowering (Traction). In-car telephone. Power door. Range of seats (Tip-up, Perching, Sliding). Special controls for visually impaired. NEW Additional Features and Improvements include: NEW material - Extruded aluminium profiles to provide a strong lightweight frame using customised extrusions to suit all the control and cabling requirements. This enables ease of manufacture, assembly and installation. Modern curved panels. Free standing aluminium rails. Easy clean floor surface (Instead of carpet). Additional glass cladding to make interior seem bigger. Larger, user-friendly interior controls. Optional remote control. Ramp Choice of colours. - 2 -

Technical Specification: Available Sizes For both traction and hydraulic lifts. Internal Width Internal Length Standard 750mm 1100mm Vertical Seat 555mm 830mm Side Hung 800mm 1175 Additional Sizes (Internal measurements) 800mm 850mm 1175mm 1250mm Safety Features Include: BS5900 Certification. Fire response system with optical smoke detector and automatic return. Over speed governor (Traction). Elevator technology (Hydraulic). Sensitive edges. Safety switches. - 3 -

Elements that Impact on Life Cycle Cost The Controller board Digital Display The controller is now a key element in our New Through Floor Lift. This item will have a dramatic impact on the life cycle cost of the lift. Now with a digital display, the user will have access to the display to relay the error code to the service provider. Based on this code, the service provider will have enough information to decide what type of call out is required. Furthermore, it will reduce the likelihood of unnecessary maintenance/service callouts. Modem Another addition to the controller that will reduce the life cycle cost is the optional addition of a modem. The modem provides a remote communications link to the lift, which in the future could be used in some areas of service. Memory Using a computer link up, the service provider has now access to a memory bank that stores each time a particular fault occurs. The information gathered can be very useful in proving when a lift is misused. Installation Packaging The lift will be assembled into 5 sub assemblies and packaged into attractive logo bearing boxes. These will make the lift more affordable to transport and protect the lift in its most delicate state. Aperture Our aperture will now be installed using special spacers that enable the installation team to quickly level and square the support ring beam. This part of the installation process is the most tedious and time consuming to date. Alone, the aperture makes installation more aesthetically pleasing, and efficient. Uneven Floor Problem The problem of installing a lift in an area where an uneven surface exists poses a major problem for the installation team. We have designed in a unique element into every lift that will accommodate up to 10mm of unevenness. - 4 -

The modifications, design changes, and additions made for the New Through Floor Lift will make manufacture more efficient, installation of an entire lift achievable in one day and significantly reduce maintenance and service callouts over the life of the product. Thus dramatically reducing the life cycle cost of this type of product. - 5 -