Joint-Stock Company GIDROPRIVOD. Axial-Piston pumps of variable displacement Type НА

Similar documents
SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

PUMP AND MOTOR DIVISION

Variable Displacement Pump AA10VSO

Unit 24: Applications of Pneumatics and Hydraulics

Problem A. Nanoassembly

Steering unit. Table of contents. Features RE 11872/ Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min

Unit 24: Applications of Pneumatics and Hydraulics

A10VSO Nominal size 18 see RD A10VSO Nominal size see RD 92711

Programming the Microchip Pic 16f84a Microcontroller As a Signal Generator Frequencies in Railway Automation

Series TMM Axial Piston Motor. Technical Information

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications

Rexroth Hydraulic Pump A10VO Series User Manual

Fixed displacement vane pumps

Radial piston pumps type R and RG

Vickers. Piston Pumps

Axial Piston Variable Pump KVA

MANTA Piston Distributor for Oil and Fluid Grease

QPM3 Low pressure pump for circulation of oil in hydraulic and lubricating systems

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

ZOP, ZOT SIGMA PUMPY HRANICE GEAR PUMPS

Condensate water pump with neutralisation system

Internal gear pump PGF Series 2X and 3X

HIGH PRESSURE TECHNOLOGY HYDRAULICS PNEUMATICS TESTING EQUIPMENT

PUMP MAINTENANCE SCHEDULE AND CHECKLISTS

Table of Contents. M Series Variable Displacement Piston Pumps

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

2011 DC Electropumps Bull. Rotation Ø 15 6,45 3,5 5,7

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

The Secret of Hydraulic Schematics. BTPHydraulics

The European Ombudsman

Series PVP Variable Volume Piston Pumps

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

15/40/80CN Series Medium Pressure Filters

PVM Piston Pumps Service Manual

Mobile Hydraulic Pumps T6*M. Denison Vane Technology, fixed displacement

Extremely compact in size to allow direct flange-mounting on vehicle engine or gearbox PTOs.

IС A A RT Proceedings Volume 2. 5th International Conference on Agents and Artificial Intelligence. Barcelona, Spain February, 2013

Direct Operated Regulator for 6.0 MPa (Relieving Type) How to Order. Body size 30 40

OPERATING AND MAINTENANCE INSTRUCTIONS PUMP TYPE

Hydraulic Trouble Shooting

European Aviation Safety Agency

Midland Combustion Electric Line Heaters with Integral Panels

Q Series Piston Pumps Variable Displacement, Quiet Series for Industrial Applications

T-Series Precision Linear Actuators Installation and Service Manual DW110353GB EDITION 5.

Index Page. Pumping Systems Intensifiers Gas Boosters High Pressure Generators


PVH131/141 Variable Displacement Piston Pump - 11 Design

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

This instruction is valid for all ACD pump models shown on page 2

Variable Displacement Pump A7VO

Example. Fluid Power. Circuits

Brueninghaus Hydromatik. Variable Displacement Pump A11VO RE / for open circuits


Quiz On Information Learned From Chapter 1

P2/P3 Series Piston Pumps Variable Displacement zp09. Catalog HY CD/US

HOW THE CONTAMINATION IS MEASURED CONTAMINATION CLASSES ACCORDING TO ISO 4406:1999

Truck Hydraulics. Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

Linear modules Lifting units Rotary modules Grip modules Inductive proximity switches Plug connectors

Hydraulic Control Solutions

Conlift1, Conlift2, Conlift2 ph+

SVA SIGMA PUMPY HRANICE SELF PRIMING PUMPS

PART 2 FORKLIFT HYDRAULIC SYSTEM

RPT SIGMA PUMPY HRANICE ROTARY LOBE DISPLACEMENT PUMPS

Chapter 19 - Common Rail High Pressure Fuel Injection Systems

2/2 and 3/2 Way Size 6 Seat Valves

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

Pump ED 101. Positive Displacement Pumps. Part I Reciprocating Pumps

Pallet Jack. OWNER S MANUAL Model MH1230. Important Safety Instructions Assembly Instructions Parts and Hardware Identification

2003 Audi A4. AUDI' '3.0L V6 - AVK Engine - A4 & A6

SIGMA PUMPY HRANICE CENTRIFUGAL MULTISTAGE HORIZONTAL PUMPS

Pneumatic actuators The Original! Technics of the top class.

Vickers PVM Piston Pumps

EVAC ONLINEVAC TECHNICAL DATA EVAC ONLINEVAC 16, 24 V DC. Required maintenance space 700 mm. Required maintenance space 200 mm 360 Ø13

DR125 and DR150 Hensim Dirt Runner 125cc and 150cc Dirt Bike (VIN PREFIX LLCH or LUAH)

8. ENERGY PERFORMANCE ASSESSMENT OF COMPRESSORS 8.1 Introduction

Flow divider (flow distributor), type TQ

Rickmeier Solutions. Gear pumps for superior Lubrication

Axial Piston Fixed Displacement Motor A2FM

E08 E10. Compact Excavators

Pressure and flow control system

Hydraulic Motors. Hydraulic Motors. Installation- operating instructions. with fixed- and adjustiable displacement. Doc.-No.

PM10 VARIABLE DISPLACEMENT PUMP CLOSED LOOP CIRCUIT

DERON Air/Water Swimming pool Heat Pump. CY/DY series for Heating/Cooling. Description

hance the application of specific components, such as pumps, motors, accumulators, filters, and airline lubricators.

DSL & SVK Lubricators Product Specs and Ordering

Duplex Filters 40/160 LD /160 LDN Industrial Filters Accumulators. Filters for inline installation for continuous operation

Truck Hydraulics. Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories. parker.com/pmde

Volkswagen Jetta, Golf, GTI 1999, Liter VR6 2V Engine Mechanical, Engine Code(s): AFP 17 Engine-Lubrication (Page GR-17)

Open center control block in monoblock design MO-40

Pure Efficiency. C.C.I.A.A.: N REA Cod. Fiscale e P. IVA: Capitale Sociale versato ,00

Single- and Multi-circuit Pumps

Pressure reducing valve, direct operated, Type ZDR 6 D

IN series. Centrifugal pumps standardized to DIN-24255

SPEEDROC D30. Surface Drill Rig for marble, granite, sandstone and limestone in the dimension stone industry.

Truck Hydraulics. F1 F2 T1 VP1 PTO info Accessories. Fixed and Variable Displacement Pumps, Motors and Accessories. Catalogue HY /UK March 2004

USA Headquarters. Dynex/Rivett Inc. 770 Capitol Drive Pewaukee, WI U.S.A. Tel: FAX:

ECOCIAT. Domestic hot water heat recovery unit

Tool Turrets and Tool Discs

Cat Electronic Technician 2015A v1.0 Product Status Report 4/20/2016 2:49 PM

Transcription:

Joint-Stock Company GIDROPRIVOD Axial-Piston pumps of variable displacement Type НА

Purpose of the item. Axial-piston pumps (type НА) of variable displacement and constant direction of operational liquid flow is meant for usage in general engineering in hydraulic drives. The pumps are to operate on mineral oils of 21 to 265 mm 2 /s (sst) viscosity, at oil temperature from + 10 to + 50 С and medium temperature from + 0 to + 50 С. The recommended operational liquids are mineral oils of the type ВНИИ НП-403 ГОС 16728-78, ИГП-30, ИГП-38 according to У 38 101413-78. Nominal filtering capacity is 40 microns. Operational liquid cleanliness level is 14 according to ГОС 17216 71. Order example: Axial-piston pump with variable displacement with manual delivery control, fastening on feet, right-hand rotation, with operational volume of 224 сm 3, version УХЛ4. НАР74М-224/32 The same with flange fastening НАРФ74М-224/32 The same with left-hand rotation of drive shaft НАРФЛ74М-224/32 The same with general climatic construction. НАРФЛ74М-224/32 О4 1.1.2 Conventional graphic symbol of the pumps is given at drawing 1. 1.1.3 Constructions of delivery change mechanisms are given in the table 1. 2

Р Ш Р П Р Ш Р П а б Р Ш Р П 4 Р Ш Р П в г а НАР; b НАС; в НАМ; c НАД1 Drawing 1 Conventional graphic symbol of the pumps. Table 1 Construction of delivery change mechanisms. Construction of delivery change mechanisms Designation of delivery change mechanism Characteristics of delivery change mechanism construction With following delivery change mechanism With manual delivery change mechanism НАС НАР The pump provides operation at any delivery, which is in the range from nominal to zero. Setting of delivery is performed with driving device (for example, with cam, master cam or some other) The pump provides operation at any delivery, which is in the range from nominal to zero. Setting of delivery is manual. 3

With power regulator НАД1 The pump provides operation in the mode of constant power. The delivery setting is automatic, depends on operational pressure at pump outlet. With electro-magnet delivery change mechanism НАМ The pump provides operation at any of four deliveries from nominal to minimal. Delivery setting is provided by electro-magnet switching-on, switching-on sequence of every of four fixed deliveries is random. Technical data Main technical data and pump parameters at operation with mineral oil of 30+ 5 mm 2 /s (sst) viscosity, at nominal revolution speed and outlet pressure are given in the table 2. Overall and joint dimensions are given on the drawings 2, 3, 4 and in the table 3. The allowed duration of maximal pressure continuous action should be not more than 40 seconds with load bread of not less than four seconds. At these modes 90% of life time is 1200 hours. Uninterrupted duration at delivery less than minimal should not be more than 30 minutes. 4

Table 2 Main technical data of the pumps. Parameter name 1 Nominal operational volume of the pump, cm 3 : а) axial-piston; b) gear 2 Revolution speed, s 1 : - nominal; - maximal; - minimal 3 Pump delivery, l/min: а) axial-piston: - nominal; - minimal b) gear Parameter value 45 90 224 45 28 25 25 8,3 57 5,7 33 90 28 25 25 8,3 122 12 33 224 28 16,6 25 8,3 200 20,0 22 Table 2. (continuation) Parameter name 4 Pressure at pump outlet, МPа: а) axial-piston: - nominal; - maximal b) gear: - nominal; - maximal 5 Pressure at pump inlet, МPа: - maximal; - minimal 6 Pump delivery factor, not less than: а) axial-piston; Parameter value 45 90 224 32 40 2,5 3 +0,05-0,02 0,92 0,94 b) gear 0,87 5

7 Pump efficiency, not less than 0,77 0,89 8 Pump weight (without operational liquid) kg, not more than: - НАР and НАС; - НАМ; - НАД1 128 135 137 182 189 190 342 356 358 9 Pump power, kw 40,5 73 118,5 10 Operational range of delivery adjustment 0,1 1,0 11 Adjustment data According to table 4 12 Full 90% life time, hours 7250 13 90% operation until failure, hours 3900 Note 1 Delivery dependence on pressure for the pumps НАД1 is shown on the drawing 5. 2 Dependence of delivery factor and pump efficiency on delivery is shown on the drawings 6,7. 3 Power of the pumps of the type НАД1 depending on pressure, is shown on the drawing 8. Table 3 Overall and joint dimensions Pump L l 1 l 2 l 3 l 4 l 5 l 6 l 7 l 8 H h 1 h 2 h 3 h 4 h 5 C designation НАР74М- 90/32 698 НАC74М- 708 90/32 179280 НАM74М- 760 90/32 - - 368 160 32 315 НАД174М- 90/32 785 НАРФ74М- 90/32 698 246 130 210 82 23 3 129 НАCФ74М- 708 90/32 - НАMФ74М- 760 90/32-140 7 345 - - - НАД1Ф74М- 90/32 785 6

НАР74М- 224/32 НАC74М- 224/32 НАM74М- 224/32 НАД174М- 224/32 НАРФ74М- 224/32 НАCФ74М- 224/32 НАMФ74М- 224/32 НАД1Ф74М- 224/32 797 807 205350 - - 455 200 37 380 859 884 298 154 233 105 32 4 168 797 807 - - 156 5 433 - - - 859 864 C 1 C 2 C 3 C 4 Д Д1 Д2 d d 1 d2 d3 d4 d5 d6 b t 270 - - - - 18-66 40 60 275 250 230h6 55h6 М36 2-6Н 45 М12-7Н 15-22 45 М10-7Н 15-18 - 16 59 7

330 - - - - 28-87 64 90 362 324 270h6 70h6 М48 2-6Н 59 М12-7Н 15-22 62 М10-7Н 17-24 - 20 74,5 8

l 3 l 4 l 5 5 4 Е l 8 Р п Р ш к 3 / 8 " Г О С 6 1 1 h 3 h 4-5 2 3 0 d 2 b h 9 d 1 7 5 d t Д 2 Д l 6 х о д 2 0 l 7 1 2 I Р ш Р п Ж Е H h 1 4 о т в. d 6 И 3 4 5 h 2 l 1 l 2 1 3 7 1 С С L Ж г d 4 h 5 Е Д 1 4 о т в. d 5 C 3 C 2 6 о т в. d 3 4 C 1 piston pump; 2 pipe-line; 3 gear pump; 4 safety valve; 5 Electro-magnetic delivery change mechanism; axle of pump suction hole; РП axle of piston pump supercharging hole; РШ axle of gear pump supercharging hole; Е pipe-line for pumps НАД1 и НАД1Ф; И plug for oil drain from the pump. Drawing 2 Overall and joint dimensions of pumps with electro-magnetic delivery change mechanism. 9

3 0 х о д 2 0 Р ш 2 3 4 Р п 1 2 4 1 5 4 5 4 Е Ж Г Г 1 2 h 9 Р ш Е З 4 0 h 6 4 3 З 9 1 2 7 5 8 2 З 1 3 0 h 6 З 1 6 5 к 3 / 8 " Г О С 6 1 1-5 2 5 о т в. M 1 2-7 Н 1 5-2 2 З 4 5 1 3 7 5 4 3 Ж г 2 5 2 9 T З 4 5 1 И 4 о т в. M 1 0-7 H 1 5-1 8 7 1 2 0 9 4 6 0 2 3 4 3 4 5 Г - Г г Р ш М 3 6 2-6 Н 4 0 6 8 1 piston pump; 2 pipe-line; 3 gear pump; 4 safety valve; 5 Electro-magnetic delivery change mechanism; axle of pump suction hole; РП axle of piston pump supercharging hole; РШ axle of gear pump supercharging hole; Е pipe-line for pumps НАД1 и НАД1Ф; И plug for oil drain from the pump. Drawing 3 Overall and joint dimensions of pumps НАМФ 45/35с with electro-magnetic delivery change mechanism. 10

З 6 H 7 Х о д 2 0 L Х о д 2 0 1 0 5 L а б L 1 6 2 в Drawing 4 Delivery change mechanisms а manual control НАР; b following control НАС; c power regulator of the type НАД1 11

Q [ л / м и н ] 1, 0 0, 9 0, 8 0, 7 0, 6 0, 5 0, 4 0, 3 0, 2 0, 1 5 1 0 1 5 2 0 2 5 3 0 3 2 Q Q =, Q Н 1 2 3 4 Р [ M P a ] where Q is pump delivery, Qн is nominal pump delivery 1 corresponds to regulator adjustment at maximal power; 2 and 3 intermediate power value; 4 minimal power Drawing five Delvery of axial-piston pump of the type НАД1 depending on pressur4 for given modes of adjustment: К Q % 1 0 0 90 80 70 60 5 0 4 0 30 20 10 Н А... 7 4 М - 2 2 4 / 3 2 Н А... 7 5 М - 9 0 / 3 2 Н А... 7 5 М - 4 5 / 3 2 0 0, 1 0, 2 0, 3 0, 4 0, 5 0, 6 0, 7 0, 8 0, 9 1, 0 Q Drawing 6 Dependence of delivery factor (К Q ) of axial-piston pumps on delivery at nominal pressure 12

К П Д 1 0 0 90 80 70 60 5 0 4 0 30 20 10 Н А... 7 4 М - 2 2 4 / 3 2 Н А... 7 5 М - 9 0 / 3 2 Н А... 7 5 М - 4 5 / 3 2 0 0, 1 0, 2 0, 3 0, 4 0, 5 0, 6 0, 7 0, 8 0, 9 1, 0 Drawing 7 Dependence of axial-piston pumps efficiency from the delivery at nominal pressure N 1, 0 0, 9 0, 8 0, 7 0, 6 0, 5 0, 4 0, 3 0, 2 0, 1 5 1 0 1 5 2 0 2 5 3 0 3 2 N N =, where N pump power, kw, Nн nominal pump power 1 maximal power of regulator adjustment; 2 and 3 possible intermediate modes of regulator adjustment; 4 minimal power of regulator adjustment Drawing 8 Power of axial-piston pump of the type НАД1 depending on pressure for given modes of adjustment: Table 4 Adjustment parameter 13 N Н Q 1 2 3 4 Р [ M P a ]

Mechanism type Manual Following Electro-magnetic Power regulator Parameter name Parameter value Torque, Н cm, not more than 25 Nut turn number, not more than 11 Direction of nut turn for delivery Clockwise increase Strengthening of exit rod of mechanism on delivery increase, moving to the 170 pump side, N, not more than Working stroke of mechanism rod, mm, 20 not more than Allowed number of switching per 40 minute Quantity of adjustment delivery 4 Allowed number of switching per 40 minute Time of delivery change from minimal to nominal and vice versa, seconds, not 0,2 more than Power consumption by electro-magnet, 26 W Allowed amount of operations per 40 minute Accuracy of the given mode of adjustment setting. ±10% Accuracy of support of set power value ±15% Allowed rate of pressure change at pump 350 outlet МPa/s, not more than Pump content Pump content is given in the table 5. Table 5 Pump content Pump type НАР Piston pump Gear pump НАС Table continuation 5 Pump type НАМ 14 Pump content Manual delivery change mechanism Piston pump Gear pump Following delivery change mechanism Piston pump Pump content

НАД1 Gear pump Electro-magnetic delivery change mechanism Piston pump Gear pump Power regulator Pipe-line 15

1 2 3 4 5 6 7 8 9 1 0 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 9 З 16 2 7 2 6 2 5 2 4 2 2 2 1 2 0 Drawing 9 Axial-piston pump 16