H1 Axial Piston Pump Size 089/100, Single. Technical Information

Similar documents
H1 Axial Piston Pump, Size 078, Single Technical Information Dimensions

Series TMM Axial Piston Motor. Technical Information

Series 40 Axial Piston Motors. Technical Information

Series PVP Variable Volume Piston Pumps

PVM Piston Pumps Service Manual

Variable Displacement Pump AA10VSO

Dual Path Mobile Pump

H1 Bent Axis Variable Displacement Motors Size 060 Size 080 Size 110 Size 160. Technical Information

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

PVH131/141 Variable Displacement Piston Pump - 11 Design

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Example. Fluid Power. Circuits

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BQ SERIES

Steering unit. Table of contents. Features RE 11872/ Type LAGL. Frame sizes 500 to 1000 Component series 1X Maximum flow 80 l/min

Extremely compact in size to allow direct flange-mounting on vehicle engine or gearbox PTOs.

Series cc Axial Piston Pump. Parts Manual

Rexroth Hydraulic Pump A10VO Series User Manual

Hydraulic Control Solutions

PM10 VARIABLE DISPLACEMENT PUMP CLOSED LOOP CIRCUIT

Series PAVC Variable Displacement Piston Pumps zp01. Catalog HY CD/US

Q Series Piston Pumps Variable Displacement, Quiet Series for Industrial Applications

A10VSO Nominal size 18 see RD A10VSO Nominal size see RD 92711

SCP ISO. Other advantages: SCP ISO is a series of piston pumps with a fixed displacement for mobile and stationary hydraulics.

VARIABLE DISPLACEMENT AXIAL PISTON PUMPS. For truck applications

Joystick PVRES and PVREL. Technical Information

P2/P3 Series Piston Pumps Variable Displacement zp09. Catalog HY CD/US

Table of Contents. Overview 1. Pump Disassembly 2. Control Disassembly / Reassembly 7. Pump Reassembly 13. Adjustment Procedures DR Control 19

Vickers. Check Valves. Check Valves. Inline, right angle, manifold mounted, and pilot operated designs. Released 9/93

D660 Series Servo-Proportional Control Valves with Integrated Electronics ISO 4401 Size 05 to 10

220 Series Piston Pump Typical Applications Features and Benefits

Cartridge Valves. Solenoid Valves. Vickers. Screw-in Cartridge Valves. Maximum Pressure 210 bar (3000 psi) Maximum Flow 227 l/min (60 USgpm)

15/40/80CN Series Medium Pressure Filters

Unit 24: Applications of Pneumatics and Hydraulics

Unit 24: Applications of Pneumatics and Hydraulics

Table of Contents. M Series Variable Displacement Piston Pumps

Description. Dimensions. Features. precision works better

Hydraulic Motor/Pump. Series F11/F12 Fixed Displacement. parker.com/pmde

Proportional relief valves type AGMZO-TERS, AERS two stage, with integral or remote pressure transducer, ISO 6264 size 10, 20 and 32

Cat Electronic Technician 2015A v1.0 Product Status Report 4/20/2016 2:49 PM

Check Valves. Pilot Operated Check Valves. Vickers. PCGV-6/8, 10 Series; PCG5V-6/8, 20 Series. Typical Section. Features and Benefits

Fluid. Flu. Fluid Fluid. uid Power d Power P. Fluid Power P. Fluid Power. Fluid Power Power. d Power. Directional Cetop Valves DCV 03.

I nstallation. M100Q Series Proportional Actuator with R81Q Controller Board for Thermistor Sensor Applications. Tools Needed.

COUNTERBALANCE VALVES

Char-Lynn Spool Valve Hydraulic Motors. Repair Information. W Series Geroler Motors

HYDRAULIC MOTORS HYDRAULIC SYSTEMS DIVISION. Outstanding Hydraulic Products, Service and Expertise, Worldwide

Pressure Relief. Pressure Control Valve R(C)G(O)-03, 06 and 10; R(C)T(O)-03, 06 and 10 VICKERS. Basic Characteristics. Sectional Illustrations

SELF-STEERING AXLE TABLE OF CONTENTS

Radial piston pumps type R and RG

Assisted lift operated 2/2-way solenoid valves Type EV250B

HYDRAULIC COMPONENTS HYDROSTATIC TRANSMISSIONS

Chapter 5: Flow Valves

Signature and ISX CM870 Electronics

4 Posiflow Proportional Solenoid Valves

DuraForce HPV Variable Pumps for Closed Loop Operation

ACCUMULATOR INSTALLATION

E4E PILOT OPERATED DIRECTIONAL CONTROL VALVE WITH ELECTRIC PROPORTIONAL CONTROL SERIES 51

Char-Lynn Hydraulic Motor. Repair Information Series. October, 1997

Flow Control Valves. Note: Also see R04C3 on page DC1. Denotes New Winner s Circle Product Line. Catalog HY /US

Mobile Hydraulic Pumps T6*M. Denison Vane Technology, fixed displacement

Series 6000 Torque measured metal bellow coupling

Vickers PVM Piston Pumps

ROTARY GEAR FLOW DIVIDERS

Pressure Relief and Regulating Valves

Truck Hydraulics. Series GPA, GP1, F1, F2, T1, VP1, Fixed and Variable Displacement Pumps, Motors and Accessories

System 8. ü ( System 8

GoTo Europe Focused Delivery Program. Product Overview Hydraulics

CONNECTOR AMPLIFIER FOR PROPORTIONAL VALVES (4-20 ma Input Version)

SITEMA PowerStroke. Technical Information TI-P11. 1 Function. 2 Applications. Mould Closing Devices series FSK. Contents

PART 2 FORKLIFT HYDRAULIC SYSTEM

Oildyne. 165 Series Hydraulic Power Units. Pressures to 241 bar (3500 psi) Flows to 5.4 lpm (1.4 gpm)

HERZ-Thermal Actuators

Fixed displacement vane pumps

Volkswagen Jetta, Golf, GTI 1999, 2000 Brake System 47 Brakes - Hydraulic Components (Page GR-47)

Brueninghaus Hydromatik. Variable Displacement Pump A11VO RE / for open circuits

WHAT YOU DON T KNOW ABOUT ACCUMULATORS CAN KILL YOU!

"A" Series Variable Displacement Piston Pumps Single Pump, "OBE" Type Electro-Hydraulic Proportional Pressure & Flow Control Type

Hydraulic multidisc Brake H420

D634-P Series Direct Drive Proportional Valve with Integrated 24 V Electronics ISO 4401 Size 05

Round Housing with Side Ports

Series 7500 Torque Sensor

Axial Piston Variable Motor A6VM

3/2-way Solenoid Valve, direct-acting, NC or NO

PUMP AND MOTOR DIVISION

Load-sensing control block in mono and sandwich plate design

TECHNICAL DATASHEET #TD1404AX PWM CONTROLLED SOLENOID DRIVER

Housing diameter Shaft diameter 1. Flange (Mounting of housing) Protection class shaft input (EN 60529) Protection class housing (EN 60529)

Solenoid Operated Directional Valves

DXPE*J /215 ED. DIRECtIONAL CONtROL VALVE PILOt OPERAtED, WItH OBE AND FEEDBACK. Q max (see performance table) SERIES 30

Unit 24: Applications of Pneumatics and Hydraulics

KDG3V-5/7/8, 10 Series

Valve series MN-06 acc. to NAMUR, 3/2-way G1/4 750 Nl/min (0.762 Cv)


Truck Hydraulics. F1 F2 T1 VP1 PTO info Accessories. Fixed and Variable Displacement Pumps, Motors and Accessories. Catalogue HY /UK March 2004

Pressure Relief. Pressure Relief and Sequence Valves CG2V-6/8, 10 Series; CG5V-6/8, 20 Series. Vickers. Features and Benefits.

Line rupture protection valves type LB

TECHNICAL DATASHEET Incremental Encoder RI 58-D / RI 58TD

VP23, 3-way proportional pressure control valves Seat valve with μp-driven pressure control

OEM Pressure Transmitters for heavy-duty applications, Type MBS 1200 and MBS 1250

Subminiature Load Cell Model 8417

PVQ 40-B2/M2 * *** - ** * * - 10 C** *** *** * - 10/11/12/20 PVQ 45-B2/M2 * *** - ** * * - 10 C**

Transcription:

H1 Axial Piston Pump Size 089/100, Single Technical Information

Revisions Revision History Table of revisions Date Page Changed Rev 03 Aug, 2009 First edition AA Apr 2010 8, 9, 23-27, BA Jun, 2010 4-6, 12, 14, New EC directive CA 16, 18-19 Dec 2012 Various AC added, pressure changed DA Further available literature 2012 Sauer-Danfoss. All rights reserved. 2 11069970 Rev DA Dec 2012 Description SD order number Overview, H1 Axial Piston Pumps, Single and Tandem L1012919 Basic Information, H1 Axial Piston Pumps, Single and Tandem 11062168 H1 Axial Piston Pump, Size 045/053, Single 11063344 H1 Axial Piston Pump, Size 045/053, Tandem 11063345 H1 Axial Piston Pump, Size 060/068, Single 11071685 H1 Axial Piston Pump, Size 069/078, Single 11062169 H1 Axial Piston Pump, Size 089/100, Single 11069970 H1 Axial Piston Pump, Size 115/130, Single 11063346 H1 Axial Piston Pump, Size 147/165, Single 11063347 H1 Automotive Control for Single Axial Piston Pumps 045-165 cc L1223856 Complementary Products External Remote Charge Pressure Filter 11064579 Speed and Temperature Sensor 11046759 Pressure Sensor L1007019 Hydraulic Fluids, Hydraulic Fluids and Lubricants 520L0463 Experience with Biodegradable Hydraulic Fluids 520L0465 Design Guideline for Hydraulic Fluid Cleanliness 520L0467 Application Information Applications Manual, Section 1, Selection of Driveline Components BLN-9885 Applications Manual, Section 2, Pressure and Speed Limits for Hydraulic Units BLN-9884 Applications Manual, Section 4, Transmission Circuit Recommendations BLN-9886 PLUS+1 COMPLIANT (Electrical Installation) H1 Electrical Displacement Control (EDC) 11022744 H1 3-position (FNR) Electric Control 11025001 H1 Non-Feedback Proportional Electric (NFPE) Control 11025002 Service Manuals H1 Axial Piston Pump, Size 045/053, Single 520L0958 H1 Axial Piston Pump, Size 045/053, Tandem 520L0928 H1 Axial Piston Pump, Size 069/078/089/100/115/130/147/165, Single 520L0848 T000 143E Sauer-Danfoss accepts no responsibility for possible errors in catalogs, brochures and other printed material. Sauer -Danfoss reserves the right to alter its products without prior notice. This also applies to products already ordered provided that such alterations can be made without affecting agreed specifications. All trademarks in this material are properties of their respective owners. Sauer-Danfoss, the Sauer-Danfoss logotype, the Sauer-Danfoss S-icon, PLUS+1, What really matters is inside and Know-How in Motion are trademarks of the Sauer-Danfoss Group. Front cover illustrations: F500 005, P003 515

Content Technical Specifications General Technical Specifications Dimensions Charge Pump Installation Drawings Technical Specifications... 4 Shaft Loads... 6 Mounting Flange Loads... 7 Model Code... 8 Electrical Displacement Control (EDC) Options A2 (12 V)/A3 (24 V)...12 Forward-Neutral-Reverse (FNR) Electric Control Options A9 (12 V)/B1 (24 V)...14 Non Feedback Proportional Electric Control (NFPE) Options A8 (12 V)/B8 (24 V)...16 Automotive control (AC)...18 Manual Over Ride (MOR)...20 Displacement Limiter...21 Input Shafts...22 Option G1, ISO 3019-1, outer dia 32 mm-4 (SAE C, 14 teeth)...22 Option G9, ISO 3019-1, outer dia 38 mm-4 (SAE C-C, 23 teeth)...22 Option F1, ISO 3019-1, outer dia 35 mm-4 (SAE C, 21 teeth)...23 Option F4, ISO 3019-1, Code 38-3, Diameter 38.1 taper 1:8, without key and no through-hole in the end of the shaft...24 Auxiliary Mounting Pads...25 Option H2, ISO 3019-1, flange 82-2 (SAE A, 9 teeth)...25 Option H1, ISO 3019-1, flange 82-2 (SAE A, 11 teeth)...26 Option H3, ISO 3019-1, flange 101-2 (SAE B, 13 teeth)...27 Option H5, ISO 3019-1, flange 101-2 (SAE B-B, 15 teeth)...28 Option H6, ISO 3019-1, flange 127-4 (SAE C, 14 teeth)...29 Charge Pump...30 Port Description...32 Dimensions...34 Controls...37 Electric Displacement Control (EDC), option A2 (12 V)/A3 (24 V)...37 Electric Displacement Control (EDC), with manual override, option A4 (12 V)/A5 (24 V)...37 Forward-Neutral-Reverse (FNR) with manual override, option A9 (12 V)/B1 (24 V)..38 Non Feedback Proportional Electric control (NFPE), with manual override, option A8 (12 V)/B8 (24 V)...38 Automotive control (AC) with manual override, option A7 (12 V)/C2 (24 V)...39 Displacement limiters...40 Displacement limiters, option B...40 Filtration...41 Suction filtration, option L...41 Dimensions...42 Remote full flow charge pressure filtration, option P for end cap options F5 (SAE-C PTO)...42 Integral full flow charge pressure filtration with filter bypass sensor, option M, for end cap option D3...43 Integral full flow charge pressure filtration with filter bypass sensor, option M, for end cap option F4 (SAE-C PTO)...44 External full flow charge pressure filtration, option S for end cap option D8 or F5..45 11069970 Rev DA Dec 2012 3

Technical Specifications Technical Specifications For definitions of the following specifications, see Basic Information 11062168, Operating parameters. General specifications Design Direction of rotation Pipe connections Recommended installation position Auxiliary cavity pressure Axial piston pump of cradle swashplate design with variable displacement Clockwise, counterclockwise Main pressure ports: ISO split flange boss Remaining ports: SAE straight thread O-ring boss Pump installation position is discretionary, however the recommended control position is on the top or at the side, with the top position preferred. If the pump is installed with the control at the bottom, flushing flow must be provided through port M14 located on the EDC, FNR and NFPE control. Vertical input shaft installation is acceptable. If input shaft is at the top 1 bar case pressure must be maintained during operation. The housing must always be filled with hydraulic fluid. Recommended mounting for a multiple pump stack is to arrange the highest power flow towards the input source. Consult Sauer-Danfoss for nonconformance to these guidelines. Will be inlet pressure with internal charge pump. For reference see operating parameter on next page. Will be case pressure with external charge supply. Please verify mating pump shaft seal capability. T000 126E Technical data Feature Unit Size 089 Size 100 Displacement cm 3 [in 3 ] 89.2 [5.44] 101.7 [6.21] Flow at rated (continuous) speed l/min [US gal/min] 294 [77.7] 335 [88.5] Torque at maximum displacement (theoretical) Mass moment of inertia of rotating components Mass [weight] dry (without auxiliary mounting flange and filter) N m/bar [lbf in/ 1000psi] 1.42 [870] 1.62 [990] kg m 2 [slug ft 2 ] 0.0116 [0.0086] kg [lb] 62 [137] Oil volume liter [US gal] 2.6 [0.67] Mounting flange ISO 3019-1 flange 127-4 (SAE C) Input shaft outer diameter, splines and tapered shafts Auxiliary mounting flange with metric fasteners, shaft outer diameter and splines Suction port Main port configuration Case drain ports L2, L4 (SAE O-ring boss) Other ports Customer interface threads ISO 3019-1, outer dia 32 mm - 4 (SAE C, 14 teeth) ISO 3019-1, outer dia 35 mm - 4 (SAE C, 21 teeth) ISO 3019-1, outer dia 38 mm - 4 (SAE C-C, 23 teeth) Conical keyed shaft end similar to ISO 3019-1 code 38-3, taper 1:8 ISO 3019-1, flange 82-2, outer dia 16 mm - 4 (SAE A, 9 teeth) ISO 3019-1, flange 82-2, outer dia 19 mm - 4 (SAE A, 11 teeth) ISO 3019-1, flange 101-2, outer dia 22 mm - 4 (SAE B, 13 teeth) ISO 3019-1, flange 101-2, outer dia 25 mm - 4 (SAE B-B, 15 teeth) ISO 3019-1, flange 127-4, outer dia 32 mm - 4 (SAE C, 14 teeth) Port ISO 11926-1 1 5 / 8-12 (SAE O-ring boss) 25.4-450 bar split flange boss per ISO 6162, M12x1.75 Port ISO 11926-1 1 1 / 16-12 (SAE O-ring boss) SAE O-ring boss. See installation drawings at the back of this manual. Metric fasteners T301 009E 4 11069970 Rev DA Dec 2012

Technical Specifications Technical Specifications For definitions of the following specifications, see Basic Information 11062168, Operating parameters. Operating parameters Feature Unit Size 089 Size 100 Minimum for internal charge supply at minimum charge pressure. Performance (pressure and displacement) may be limited 500 due to limited control pressure Minimum for external charge supply at minimum charge pressure. Full performance Input speed (pressure and displacement) possible at minimum min -1 (rpm) 500 charge and control pressure supply Minimum for full performance (pressure and displacement) for internal charge supply at 1200 minimum charge and control pressure Rated 3300 Maximum 3800 Maximum working pressure 450 [6525] System pressure Maximum pressure 480 [6960] bar [psi] Maximum low loop 45 [650] Minimum pressure 10 [145] Charge pressure Minimum 16 [232] bar [psi] Maximum 34 [493] Minimum (at corner power for EDC and 17 [247] FNR) Control pressure bar [psi] Minimum (at corner power for NFPE) 20 [290] Maximum 40 [580] Rated 0.7 [9] Charge pump bar (absolute) [in Hg vacuum] Minimum (cold start) 0.2 [24] inlet pressure Maximum bar [psi] 4.0 [58] Case pressure Rated 3.0 [44] bar [psi] Maximum 5.0 [73] Lip seal external pressure Maximum bar [psi] 0.4 [5.8] T301 010E Fluid specifications Feature Unit Intermittent 1) 5 [42] Viscosity Minimum 7 [49] mm 2 /s [SUS] Recommended range 12-80 [66-370] Maximum 1600 [7500] Minimum (cold start) 3) -40 [-40] Temperature Recommended range 60-85 [140-185] C [ F] range 2) Rated 104 [220] Maximum intermittent 1) 115 [240] Cleanliness per ISO 4406 22/18/13 Filtration Efficiency (charge pressure filtration) β (recommended β-ratio 15-20 = 75 (β 10 10) Efficiency (suction and return line filtration) minimum) β 35-45 = 75 (β 10 2) Recommended inlet screen mesh size µm 100 125 1) Intermittent = Short term t < 1min per incident and not exceeding 2 % of duty cycle based load-life 2) At the hottest point, normally case drain port 3) Cold start = Short term t < 3min, p 50 bar [725 psi], n 1000 min -1 (rpm) T000 129E 11069970 Rev DA Dec 2012 5

General Technical Specifications Shaft Loads External radial shaft loads H1 pumps are designed with bearings that can accept some external radial loads. The external radial shaft load limits are a function of the load position and orientation, and the operating conditions of the unit. External radial shaft loads impact lifetime. For lifetime calculations please contact Sauer-Danfoss representative. The maximum allowable radial load (R e ) is based on the maximum external moment (M e ) and the distance (L) from the mounting flange to the load. It may be determined using the following table and formula. R e = M e / L Radial load position 0 R e L R e 270 R e 90 R e M e 180 R e P003 318E M e = Shaft moment L = Flange distance R e = External force to the shaft Thrust loads should be avoided. Contact factory in the event thrust loads are anticipated. 6 11069970 Rev DA Dec 2012

General Technical Specifications Shaft Loads Maximum external shaft load based on shaft deflection: Unit Size 089/100 External radial moment M e Nm [lbf in] 118 [1044] T301 012E All external shaft loads affect the before mentioned bearing life. In applications with external shaft loads, minimize the impact by positioning the load at 0 or 180 as shown in the figure. Contact your Sauer-Danfoss representative for an evaluation of unit bearing life. Sauer-Danfoss recommends clamp-type couplings for applications with radial shaft loads. Mounting Flange Loads Mounting flange load Unit Size 089/100 Rated moment M R 5630 [49830] Nm [lbf in] Shock load moment M S 12190 [107900] T301 013E For calculation details refer to H1 Pump Basic Information Manual 11062168, section Mounting Flange Loads. M R M S P001 916 11069970 Rev DA Dec 2012 7

General Technical Specifications Model Code A B D F E G H J K M N S T V W X Y H1 P A H A B D F E G Displacement 089 89.2 cm³ [5.44 in³] 100 101.7 cm³ [6.21 in³] Rotation L Left hand (counter clockwise) R Right hand (clockwise) Product version B Revision code Control A2 Electric Displacement Control (EDC) 12V, Deutsch connector A3 Electric Displacement Control (EDC) 24V, Deutsch connector A4 Electric Displacement Control (EDC) 12V, Deutsch connector, Manual override A5 Electric Displacement Control (EDC) 24V, Deutsch connector, Manual override A9 Forward-Neutral-Reverse (FNR) 12V, Deutsch connector, Manual override B1 Forward-Neutral-Reverse (FNR) 24V, Deutsch connector, Manual override A8 Non Feedback Proportional Electric (NFPE) 12V, Deutsch connector, Manual override (align with option E: Displacement Limiters & option W: Special Hardware) B8 Non Feedback Proportional Electric (NFPE) 24V, Deutsch connector, Manual override (align with option E: Displacement Limiters & option W: Special Hardware) A7 AC-1 (Automotive), 12V, Manual Override (align with option E: Displacement Limiters & option W: Special Hardware) C2 AC-1 (Automotive), 24V, Manual Override (align with option E: Displacement Limiters & option W: Special Hardware) Orifices C1 Orifices, 0.8 mm in servo supply 1 and 2, recommended for propel applications C2 Orifices, 1.3 mm in servo supply 1 and 2 (Standard), recommended for propel applications C3 No orifice, recommended for non-propel applications Displacement limiters N None C No limiters, with nested springs (required for NFPE) (align with option Y: Settings for adjustment, if applicable) B Adjustable externally (see option Y: Settings for adjustment, if applicable) D Adjustable externally with nested springs, required for NFPE Endcap options Match with below options (K) Match with below options (T) D3 F4 D6 F5 D8 F6 Twin port, ISO 6162 Split flange ports Auxiliary mounting pad None, ISO 3019-1, flange 82-2 (SAE A, 9 and 11 teeth) ISO 3019-1, flange 101-2 (SAE B, 13 teeth) ISO 3019-1, flange 101-2 (SAE B-B, 15 teeth) Suction filtration X Integral full Remote or external charge flow charge supply for full filtration charge flow filtration X X Auxiliary mounting pad ISO 3019-1, flange 127-4 (SAE C, 14 teeth) Suction filtration X Integral full charge flow filtration X Remote or external charge supply for full charge flow filtration X 8 11069970 Rev DA Dec 2012

General Technical Specifications Model Code A B D F E G H J K M N S T V W X Y H1 P N N N N N N H J K Mounting H ISO 3019-1, flange 127-4 (SAE C) Input shaft G1 ISO 3019-1, outer dia 32 mm - 4 (SAE C, 14 teeth splined shaft 12 /24 pitch) F1 ISO 3019-1, outer dia 35 mm - 4 (SAE C, 21 teeth splined shaft 16 /32 pitch) G9 ISO 3019-1, outer dia 38 mm - 4 (SAE C-C, 23 teeth splined shaft 16 /32 pitch F4 Conical keyed shaft end similar to ISO 3019-1 code 38-3, taper 1:8 (key not supplied with pump) Auxiliary mounting pad (align with option G: Endcap selection) NN None H2 ISO 3019-1, flange 82-2, outer dia 16 mm - 4 (SAE A, 9 teeth 16 /32 coupling) H1 ISO 3019-1, flange 82-2, outer dia 19 mm - 4 (SAE A, 11 teeth 16 /32 coupling) H3 ISO 3019-1, flange 101-2, outer dia 22 mm - 4 (SAE B, 13 teeth 16 /32 coupling) H5 ISO 3019-1, flange 101-2, outer dia 25 mm - 4 (SAE B-B, 15 teeth 16 /32 coupling) H6 ISO 3019-1, flange 127-4, outer dia 32 mm - 4 (SAE C, 14 teeth 12 /24 coupling) M Overpressure protection type and setting side A ** N Overpressure protection type and setting side B ** ** Pressure protection type must be the same for side A and B Shipping cover S L K High pressure relief valve + pressure limiters with bypass High pressure relief valve with bypass (no pressure limiters) L15 K15 150 bar [2175 psi] L18 K18 180 bar [2610 psi] L20 K20 200 bar [2900 psi] L23 K23 230 bar [3336 psi] L25 K25 250 bar [3630 psi] L28 K28 280 bar [4061 psi] L30 K30 300 bar [4350 psi] L33 K33 330 bar [4786 psi] L35 K35 350 bar [5080 psi] L38 K38 380 bar [5510 psi] L40 K40 400 bar [5800 psi] L42 K42 420 bar [6090 psi] L43 430 bar [6237 psi] (089 cm 3 only) L44 440 bar [6382 psi] (089 cm 3 only) L45 K45 450 bar [6960 psi] (089 cm 3 only) Use the selection for ports A and B Contact factory for pressures not shown or for applied pressure above maximum working pressure (see System Pressure page 5) Charge pump D 20 cm³/rev [1.22 in³/rev] M 24 cm³/rev [1.46 in³/rev] N No charge pump, external charge supply, (align with Option T: Filtration Options, option E) 11069970 Rev DA Dec 2012 9

General Technical Specifications Model Code A B D F E G H J K M N S T V W X Y H1 P N N N N N N T V W X Y Filtration options (align with option G: Endcap selection) L Suction filtration (see basic drawings) Integral full charge flow filtration with bypass and bypass sensor, M medium length, order number 11004918) P Remote full charge flow filtration (see endcap drawings) E External charge flow filtration (see endcap drawings), (align with option S: Charge pump, option N) Charge pressure relief setting 20 20 bar [290 psi] 24 24 bar [348 psi] 30 30 bar [435 psi] Special hardware features PN None P1 NFPE valve plate (align with option D: Control Selection and option E: Displacement Limiters) Paint and nametag NNN Black paint and Sauer-Danfoss nametag Special settings NNN None (align with option E: Displacement limiters) D3F AC1-control, System F: Functional basis, Motor Speed Sensor, CAN J1939 in/out without Customer Files, 12V D4F AC1-control, System F: Functional basis, Motor Speed Sensor, CAN J1939 in/out without Customer Files, 24V D3H AC1-control, System H: Functional basis, Motor Speed Sensor, CAN J1939 out, SIL2 certifiable without Customer Files, 12V D4H AC1-control, System H: Functional basis, Motor Speed Sensor, CAN J1939 out, SIL2 certifiable without Customer Files, 24V 10 11069970 Rev DA Dec 2012

Notes Notes 11069970 Rev DA Dec 2012 11

General Technical Specifications Electrical Displacement Control (EDC) Options A2 (12 V)/A3 (24 V) EDC Principle The Electrical Displacement Control (EDC) consists of a pair of proportional solenoids on each side of a threeposition, four-way porting spool. The proportional solenoid applies a force input to the spool, which ports hydraulic pressure to either side of a double acting servo piston. Differential pressure across the servo piston rotates the swashplate, changing the pump s displacement from full displacement in one direction to full displacement in the opposite direction. Under some circumstances, such as contamination, the control spool could stick and cause the pump to stay at some displacement. P003 191 A serviceable 125 μm screen is located in the supply line immediately before the control porting spool. Pump displacement vs. control current EDC-Schematic diagram C1 M14 C2 100 % F00B F00A Feedback from Swash plate T P P003 478E Displacement -b -a "0" a Current ma b Control signal requirements Control current Voltage a* ma b ma Pin connections 12 V 640 1640 any order 24 V 330 820 * Factory test current, for vehicle movement or application actuation expect higher or lower value. T000133E Connector 100 % P003 479E 1 2 P003 480 Description Quantity Ordering number Mating connector 1 Deutsch DT06-2S Wedge lock 1 Deutsch W2S Socket contact (16 and 18 AWG) 2 Deutsch 0462-201-16141 Sauer-Danfoss mating connector kit 1 K29657 T000 134E 12 11069970 Rev DA Dec 2012

General Technical Specifications Electrical Displacement Control (EDC) Options A2 (12 V)/A3 (24 V) Solenoid data Voltage 12V 24V Maximum current 1800 ma 920 ma Coil resistance @ 20 C [70 F] 3.66 Ω 14.20 Ω Coil resistance @ 80 C [176 F] 4.52 Ω 17.52 Ω PWM Range 70-200 Hz PWM Frequency (preferred)* 100 Hz Inductance 33 mh 140 mh IP Rating (IEC 60 529) + DIN 40 050, part 9 IP 67 IP Rating (IEC 60 529) + DIN 40 050, part 9 with mating connector IP 69K * PWM signal required for optimum control performance. T000 135E Flow table Shaft rotation CW CCW Coil energized* C2 C1 C2 C1 Port A in out out in Port B out in in out Servo port pressurized M5 M4 M5 M4 * For coil location see installation drawings. T000 136E Control response H1 controls are available with optional control passage orifices to assist in matching the rate of swashplate response to the application requirements (e.g. in the event of electrical failure). Software ramp or rate limiting should be used to control vehicle response in normal operation. The time required for the pump output flow to change from zero to full flow (acceleration) or full flow to zero (deceleration) is a net function of spool porting, orifices, and charge pressure. A swashplate response table is available for each frame indicating available swashplate response times. Testing should be conducted to verify the proper software and orifice selection for the desired response. H1 pumps are limited in mechanical orificing combinations. Software is envisioned as the means to control the swashplate response in normal operating conditions. Mechanical servo orifices are to be used only for fail-safe return to neutral in the event of an electrical failure. Typical response times shown below at the following conditions: p = 250 bar [3626 psi] Viscosity and temperature = 30 mm 2 /s (50 C) [141 SUS (122 F)] Charge pressure = 20 bar [290 psi] Speed = 1800 min -1 (rpm) Response times Stroking direction 0.8 mm [0.03 in] Orifice 1.3 mm [0.05 in] Orifice No orifice Neutral to full flow 3.8 s 1.8 s 1.0 s Full flow to neutral 2.2 s 1.0 s 0.6 s T301 014E 11069970 Rev DA Dec 2012 13

General Technical Specifications Forward-Neutral-Reverse (FNR) Electric Control Options A9 (12 V)/B1 (24 V) The 3-Position (F-N-R) control uses an electric input signal to switch the pump to a full stroke position. Under some circumstances, such as contamination, the control spool could stick and cause the pump to stay at some displacement. A serviceable 125 μm screen is located in the supply line immediately before the control porting spool. P003 193 Pump displacement vs. electrical signal 100 % 3-Position electric control, hydraulic schematic M14 C1 C2 Displacement F00B F00A T P P003 189 0 Voltage VDC Control current Voltage Min. current to stroke pump ma Pin connections 12 V 750 24 V 380 any order T000 138E 100 % P003 190E Solenoid connector 1 2 P003 480 Description Quantity Ordering number Mating connector 1 Deutsch DT06-2S Wedge lock 1 Deutsch W2S Socket contact (16 and 18 AWG) 2 Deutsch 0462-201-16141 Sauer-Danfoss mating connector kit 1 K29657 T000 134E 14 11069970 Rev DA Dec 2012

General Technical Specifications Forward-Neutral-Reverse (FNR) Electric Control Options A9 (12 V)/B1 (24 V) Solenoid data Voltage 12 V 24 V Minimum supply voltage 9.5 Vdc 19.0 Vdc Maximum supply voltage (continuous) 14.6 Vdc 27.0 Vdc Maximum current 1050 ma 500 ma Nominal coil resistance @ 20 C [70 F] 8.4 Ω 34.5 Ω PWM Range 70-200 Hz PWM Frequency (preferred)* 100 Hz IP Rating (IEC 60 529) + DIN 40 050, part 9 IP 67 IP Rating (IEC 60 529) + DIN 40 050, part 9 with mating connector IP 69K * PWM signal required for optimum control performance. T000 139E Pump output flow direction vs. control signal Shaft rotation CW CCW Coil energized* C1 C2 C1 C2 Port A in out out in Port B out in in out Servo port pressurized M5 M4 M5 M4 * For coil location see installation drawings. T000 140E Control response H1 controls are available with optional control passage orifices to assist in matching the rate of swashplate response to the application requirements (e.g. in the event of electrical failure). Software ramp or rate limiting should be used to control vehicle response in normal operation. The time required for the pump output flow to change from zero to full flow (acceleration) or full flow to zero (deceleration) is a net function of spool porting, orifices, and charge pressure. A swashplate response table is available for each frame indicating available swashplate response times. Testing should be conducted to verify the proper software and orifice selection for the desired response. H1 pumps are limited in mechanical orificing combinations. Software is envisioned as the means to control the swashplate response in normal operating conditions. Mechanical servo orifices are to be used only for fail-safe return to neutral in the event of an electrical failure. Typical response times shown below at the following conditions: p = 250 bar [3626 psi] Viscosity and temperature = 30 mm 2 /s (50 C) [141 SUS (122 F)] Charge pressure = 20 bar [290 psi] Speed = 1800 min -1 (rpm) Response times Stroking direction 0.8 mm [0.03 in] Orifice 1.3 mm [0.05 in] Orifice No orifice Neutral to full flow 3.7 s 1.7 s 1.1 s Full flow to neutral 3.0 s 1.3 s 0.6 s T301 015E 11069970 Rev DA Dec 2012 15

General Technical Specifications Non Feedback Proportional Electric Control (NFPE) Options A8 (12 V)/B8 (24 V) The Non Feedback Proportional Electric (NFPE) control is an electrical automotive control in which an electrical input signal activates one of two proportional solenoids that port charge pressure to either side of the pump servo cylinder. The NFPE control has no mechanical feedback mechanism. The pump displacement is proportional to the solenoid signal current, but it also depends upon pump input speed and system pressure. This characteristic also provides a power limiting function by reducing the pump swashplate angle as system pressure increases. A typical response characteristic is shown in the accompanying graph. P003 192 Under some circumstances, such as contamination, the control spool could stick and cause the pump to stay at some displacement. NFPE Schematic M14 A serviceable 125 μm screen is located in the supply line immediately before the control porting spool. Pump displacement vs. input signal NFPE control 100 % C1 F00B F00A Control signal requirements C2 T P P003 188 Signal Current ma(dc) c b p = 300 bar p = 0 bar a Displacement "0" p = 0 bar p = 300 bar a b c Control current Voltage Connector a* ma b ma c ma Pin connections 12 V 870 1290 1590 any order 24 V 440 670 795 * Factory test current, for vehicle movement or application actuation expect higher or lower value. T301 018E 1 2 100 % P003 187E P003 480 Description Quantity Ordering number Mating connector 1 Deutsch DT06-2S Wedge lock 1 Deutsch W2S Socket contact (16 and 18 AWG) 2 Deutsch 0462-201-16141 Sauer-Danfoss mating connector kit 1 K29657 T000 134E 16 11069970 Rev DA Dec 2012

General Technical Specifications Non Feedback Proportional Electric Control (NFPE) Options A8 (12 V)/B8 (24 V) Solenoid data Voltage 12V 24V Maximum current 1800 ma 920 ma Coil resistance @ 20 C [70 F] 3.66 Ω 14.20 Ω Coil resistance @ 80 C [176 F] 4.52 Ω 17.52 Ω PWM Range 70-200 Hz PWM Frequency (preferred)* 100 Hz Inductance 33 mh 140 mh IP Rating (IEC 60 529) + DIN 40 050, part 9 IP 67 IP Rating (IEC 60 529) + DIN 40 050, part 9 with mating connector IP 69K * PWM signal required for optimum control performance. T000 135E Pump output flow direction vs. control signal Shaft rotation CW CCW Coil energized* C1 C2 C1 C2 Port A in out out in Port B out in in out Servo port pressurized M5 M4 M5 M4 * For coil location see installation drawings. T000 140E Control response H1 controls are available with optional control passage orifices to assist in matching the rate of swashplate response to the application requirements (e.g. in the event of electrical failure). Software ramp or rate limiting should be used to control vehicle response in normal operation. The time required for the pump output flow to change from zero to full flow (acceleration) or full flow to zero (deceleration) is a net function of spool porting, orifices, and charge pressure. A swashplate response table is available for each frame indicating available swashplate response times. Testing should be conducted to verify the proper software and orifice selection for the desired response. H1 pumps are limited in mechanical orificing combinations. Software is envisioned as the means to control the swashplate response in normal operating conditions. Mechanical servo orifices are to be used only for fail-safe return to neutral in the event of an electrical failure. Typical response times shown below at the following conditions: p = 250 bar [3626 psi] Viscosity and temperature = 30 mm 2 /s (50 C) [141 SUS (122 F)] Charge pressure = 20 bar [290 psi] Speed = 1800 min -1 (rpm) Response times Stroking direction 0.8 mm [0.03 in] Orifice 1.3 mm [0.05 in] Orifice No orifice Neutral to full flow 4.3 s 1.9 s 1.1 s Full flow to neutral 2.6 s 1.1 s 0.5 s T301 016E 11069970 Rev DA Dec 2012 17

General Technical Specifications Automotive control (AC) The H1 Automotive Control (H1 AC) is an electric NFPE Control with an integrated Microcontroller, installed on the pump. The integrated Microcontroller enhanced control performance with a flexible, configurable control scheme for an entire single path propel transmission. With the pre-installed application software and easily changeable control parameters, it is possible to tailor the vehicle s driving behavior to the individual requirements of the customer. CC3 CC1 CAN PPC PSC PPU CC2 WARRANTY VOID IF REMOVED The H1 AC Control offers the following features and functions: P003 544 Driving Profiles Four selectable system modes, selectable via switch. Independent curves and settings for forward and reverse (4 x 2 curves). Switch selectable between automotive and engine speed independent driving modes. Engine speed independent drive modes for sweepers, snow blowers (non-automotive mode). Load independent drive modes for off road applications (nonautomotive for rollers and forestry machines). Load independent swash plate control via pump swash plate angle sensor to achieve EDC behavior Creep speed mode (slow shunting, digging operation, etc.) Constant speed mode (sweepers, snow-blowers, etc.) Integrated vehicle speed limiter function. Advanced Control Functions Inch function without separate control valve. Integrated temperature sensor for: Hydraulic systems overheat protection. Low temperatures pump flow limitation. Compensation of oil viscosity changes if using (radial piston motors, etc.). Configurable engine anti stall protection. Engine over speed protection while inching. Integrated Motor Controller Integrated electric motor control for: Proportional, variable PCOR or two position motor controls. Brake pressure defeat, depending on the FNR position or the real vehicle driving direction. Initial breakaway motor torque override. Separate over speed protection for the hydro motor. 18 11069970 Rev DA Dec 2012

General Technical Specifications Automotive control (AC) Auxiliary Functions Four auxiliary outputs for : Intelligent brake light control. Automatic park brake function. Vehicle speed dependent output to activate (load stabilizer, warning lights, etc.). Reverse buzzer controlled by FNR or reverse driving. System status lamp (fault detection for pump solenoids). Economic Features Technology and enabler for economic driving and fuel savings. Easy combination options to other components of the PLUS+1 Family. CAN Options Engine remote control via CAN J1939. Integrated signal converter (analog driving pedal into CAN signal, etc.). Compatible to all CAN J1939 components on market (displays, etc.). Functional Safety External Safety Certification for SIL-2 (IEC 61508). Safety controlled Vehicle Start-Protection (engine speed check, battery check and FNR must be in neutral, etc.). Operator presence detection. Vehicle speed dependent direction change lock. Brake test mode for roller applications to fulfill EN500-4. Installation Features Factory calibration for hysteresis compensation. Starting current adjustment in the factory Pre-installed application software and parameter files Refer to the H1 Automotive Control L1223856 for details about installation and wiring. 11069970 Rev DA Dec 2012 19

General Technical Specifications Manual Over Ride (MOR) All controls are available with a Manual Over Ride (MOR) either standard or as an option for temporary actuation of the control to aid in diagnostics. Forward-Neutral-Reverse (FNR) and Non Feedback Proportional Electric (NFPE) controls are always supplied with MOR functionality. Unintended MOR operation will cause the pump to go into stroke. The vehicle or device must always be in a safe condition (i.e. vehicle lifted off the ground) when using the MOR function. The MOR plunger has a 4 mm diameter and must be manually depressed to be engaged. Depressing the plunger mechanically moves the control spool which allows the pump to go on stroke. The MOR should be engaged anticipating a full stroke response from the pump. Warning An o-ring seal is used to seal the MOR plunger where initial actuation of the function will require a force of 45 N to engage the plunger. Additional actuations typically require less force to engage the MOR plunger. Proportional control of the pump using the MOR should not be expected. Refer to control flowtable for the relationship of solenoid to direction of flow. P003 204 MOR-Schematic diagram (EDC shown) M14 C1 C2 F00B Feedback from Swash plate F00A T P P003 205E 20 11069970 Rev DA Dec 2012

General Technical Specifications Displacement Limiter H1 pumps are designed with optional mechanical displacement (stroke) limiters factory set to max. displacement. The maximum displacement of the pump can be set independently for forward and reverse using the two adjustment screws to mechanically limit the travel of the servo piston down to 50 % displacement. Adjustment procedures are found in the H1 pumps Service Manual. Adjustments under operating conditions may cause leakage. The adjustment screw can be completely removed from the threaded bore if backed out to far. Displacement limiter P003 266 Displacement change (approximately) Size 1 Turn of displacement limiter screw 089 9.3 cm 3 [0.57 in 3 ] 100 10.7 cm 3 [0.65 in 3 ] Internal wrench size External wrench size Torque for external hex seal lock nut 5 mm 17 mm 48 Nm 424 [lbf in] T301 017E For more information refer to H1 pumps Service Manual 520L0848, section Displacement Limiter Adjustment. 11069970 Rev DA Dec 2012 21

Dimensions Input Shafts Option G1, ISO 3019-1, outer dia 32 mm-4 (SAE C, 14 teeth) 7.94 ±0.8 [0.313 ±0.031] Mounting flange surface Flange 127-4 per ISO 3019-1 Coupling must not protrude beyond this point 48.1±1 [1.894±0.039] 28.8±1 [1.134±0.039] Spline data Number of teeth : 14 Pitch fraction : 12/24 Pressure angle : 30 Pitch- : 29.633 [1.167] Typ of fit : Flat root, side fit per : Ansi B92.1-1996 class 6H Shafts to be paint free 26 ±0.13 [1.024 ±0.005] 31.14 ±0.08 [1.226 ±0.003] P301 180 Specifications Option Spline Min active spline length 2 Torque rating 1 Rated torque Maximum torque mm [in] Nm [lbf in] Nm [lbf in] G1 14 teeth, 12/24 pitch 28.8 [1.134] 534 [4720] 816 [7220] 1) For definitions of maximum and rated torque values, refer to: Basic Information Manual 11062168, section Shaft Torque Ratings and Spline Lubrication. 2) Minimum active spline length for the specified torque ratings. T301 053E Option G9, ISO 3019-1, outer dia 38 mm-4 (SAE C-C, 23 teeth) 7.94 ±0.8 [0.313 ±0.031] Mounting flange surface Flange 127-4 per ISO 3019-1 Coupling must not protrude beyond this point 54 ±1 [2.126 ±0.039] 38.2 ±1 [1.504 ±0.039] Spline data Number of teeth : 23 Pitch fraction : 16/32 Pressure angle : 30 Pitch- : 36.513 [1.438] Typ of fit : Flat root, side fit per : Ansi B92.1-1996 class 6H Shafts to be paint free 33.6 ±0.13 [1.323 ±0.005] 37.59 ±0.08 [1.480 ±0.003] P301 181 Specifications Option Spline Min active spline length 2 Torque rating 1 Rated torque Maximum torque mm [in] Nm [lbf in] Nm [lbf in] G9 23 teeth, 16/32 pitch 38.2 [1.504] 999 [8840] 1818 [16 090] 1) For definitions of maximum and rated torque values, refer to: Basic Information Manual 11062168, section Shaft Torque Ratings and Spline Lubrication. 2) Minimum active spline length for the specified torque ratings. T301 054E 22 11069970 Rev DA Dec 2012

Dimensions Input Shafts Option F1, ISO 3019-1, outer dia 35 mm-4 (SAE C, 21 teeth) 7.94 ±0.8 [0.313 ±0.031] Mounting flange surface Flange 127-4 per ISO 3019-1 Coupling must not protrude beyond this point 48 ±1 [1.894 ±0.039] 30.7 ±1 [1.209 ±0.039] Spline data Number of teeth : 21 Pitch fraction : 16/32 Pressure angle : 30 Pitch- : 33.338 [1.313] Typ of fit : Fillet root, side fit per : Ansi B92.1-1996 class 6H Shafts to be paint free 30.4 ±0.13 [1.197 ±0.005] 34.42 ±0.08 [1.355 ±0.003] P301 182 Specifications Option Spline Min active spline length 2 Torque rating 1 Rated torque Maximum torque mm [in] Nm [lbf in] Nm [lbf in] F1 21 teeth, 16/32 pitch 30.7 [1.209] 760 [6730] 1137 [10 060] 1) For definitions of maximum and rated torque values, refer to: Basic Information Manual 11062168, section Shaft Torque Ratings and Spline Lubrication. 2) Minimum active spline length for the specified torque ratings. T301 055E 11069970 Rev DA Dec 2012 23

Dimensions Input Shafts Option F4, ISO 3019-1, Code 38-3, Diameter 38.1 taper 1:8, without key and no through-hole in the end of the shaft Mounting flange surface Flange 127-4 per ISO 3019-1 Conical keyed shaft end similar to ISO 3019-1 code 38-3 Suitable key 3 /8 x 3 /8 x 1 1 /2 ANSI B17.1 125 ±0.5 : 1000 38.1 [1.500] 1 1 /8-12 (47.0) [1.850] 81.9 ±1.0 [3.224 ±0.039] Shafts 34.9 ±1.0 [1.374 ±0.039] 8.16 ±0.8 [0.321 ±0.31] Coupling must not overlap till this point P301 183 Specifications Torque rating 1) Option Tapered shaft Rated torque* Maximum torque Nm [lfb in] Nm [lfb in] F4 38.1 taper without key 2) 1116 [9880] 1488 [13 170] 1) For definitions of maximum and rated torque values, refer to: Basic Information Manual 11062168, section Shaft Torque Ratings and Spline Lubrication. 2) Mating part must maintain a minimum gap width of 1.0 mm with the shaft shoulder after installation of the part. Transmittable torque will be reduced if the minimum gap requirement is not met. * Rated torque includes just the capability of the press-fit in accordance with an assumed fastener grade 5. Tapered shaft customer acknowledgement The Sauer-Danfoss H1 tapered shaft has been designed using the industry standard ISO 3019-1, minus the through-hole in the end of the shaft. Sauer-Danfoss recommends a self-locking nut instead of a castle nut and pin. The nut and mating square-cut key are customer supplied. The specified torque rating of the tapered shaft documented above is based on the cross-sectional diameter of the shaft, through the keyway, and assumes the proper clamp and fit between shaft and coupling. Sauer-Danfoss guarantees the design and manufactured quality of the tapered shaft. The customer is responsible for the design and manufactured quality of the mating female coupling and key and applied torque on the nut. Sauer-Danfoss has made provisions for the key in accordance to the ISO specification with the understanding that the key is solely to assist in the installation of the mating coupling. T000 149E CCaution Torque must be transmitted by the taper fit between the shaft and it s mating coupling, not the key. Torque or loading inadvertently transmitted by the customer supplied key may lead to premature shaft failure. 24 11069970 Rev DA Dec 2012

] ] H1 Axial Piston Pump, Size 089/100, Single Dimensions Auxiliary Mounting Pads Option H2, ISO 3019-1, flange 82-2 (SAE A, 9 teeth) 2x 106.4 ±0.35 [4.189 ±0.014] 4x 53.2 ±0.175 [2.094 ±0.007] Mounting flange surface Flange 82-2 per ISO 3019-1 311.838 ±2 [12.277 ±0.79] 296.83 ±2 [11.686 ±0.79] 14.8 [0.583] 0 [3.489 + 0.005 88.62 + 0.13 82.6 + 0.076 0 0 [3.252 + 0.003 0 R 0.8 max. [0.031] Thread : M10x1.5-6H THD Depth : 15.0 [0.60] min. 4x O-ring seal required ref 82.22 [3.237] I.D. x 2.62 [0.103] cross section 1.96 [0.077] 8.1 ±0.25 [0.319 ±0.010] 61.62 max [2.426] Auxiliary pump shaft length Spline data Number of teeth: 9 Pitch fraction: 16/32 Pressure angle: 30 Pitch- : 14.288 [0.5625] Typ of fit: Fillet root, side fit per: Ansi B92.1-1996 class 6 Min. active spline length 8.6 mm P301 184 Specifications Option Spline Torque rating 1 maximum torque Nm [lbf in] H2 9 teeth, 16/32 pitch 162 [1430] 1) For definitions of maximum torque values, refer to: Basic Information Manual 11062168, section Shaft Torque Ratings and Spline Lubrication. T000 150E C Caution Standard pad cover is installed only to retain coupling during shipping. Do not operate pump without an auxiliary pump or running cover installed. 11069970 Rev DA Dec 2012 25

] H1 Axial Piston Pump, Size 089/100, Single Dimensions Auxiliary Mounting Pads Option H1, ISO 3019-1, flange 82-2 (SAE A, 11 teeth) 2x 106.4 ±0.35 [4.189 ±0.014] 4x 53.2 ±0.175 [2.094 ±0.007] 19.8 [0.780] 311.838 ±2 [12.277 ±0.79] 296.83 ±2 [11.686 ±0.79] 82.6 + 0.076 0 [3.252 + 0.003 0 ] Mounting flange surface Flange 82-2 per ISO 3019-1 0 [3.489 + 0.005 88.62 + 0.13 0 R 0.8 max. [0.031] Thread : M10x1.5-6H THD Depth : 15.0 [0.60] min. 4x O-ring seal required ref 82.22 [3.237] I.D. x 2.62 [0.103] cross section 1.96 [0.077] 8.1 ±0.25 [0.319 ±0.010] 61.6 max [2.426 Auxiliary pump shaft length Spline data Number of teeth : 11 Pitch fraction : 16/32 Pressure angle : 30 Pitch- : 17.463 [0.6875] Typ of fit : Fillet root side per : Ansi B92.1-1996 class 6 min active spline length 10.5 mm P301 185 Specifications Option Spline Torque rating 1 maximum torque Nm [lbf in] H1 11 teeth, 16/32 pitch 296 [2620] 1) For definitions of maximum torque values, refer to: Basic Information Manual 11062168, section Shaft Torque Ratings and Spline Lubrication. T000 151E C Caution Standard pad cover is installed only to retain coupling during shipping. Do not operate pump without an auxiliary pump or running cover installed. 26 11069970 Rev DA Dec 2012

Dimensions Auxiliary Mounting Pads Option H3, ISO 3019-1, flange 101-2 (SAE B, 13 teeth) 4x 73.0 ±0.175 [2.874 ±0.007] 312.486 ±2 [12.303 ±0.79] 296.83 ±2 [11.686 ±0.79] 107.823 + 0.13 ] 101.651 + 0.076 0 [4.245 + 0.005 0 [4.002 + 0.003 0 0 ] 2x 146.0 ±0.35 [5.748 ±0.014] Mounting flange surface Flange 101-2 per ISO 3019-1 R 0.8 max. [0.031] 19.8 [0.780] Thread : M12x1.75-6H THD Depth : 20.0 [0.787] min. 4x O-ring seal required ref 94.92 [3.737] I.D. x 2.62 [0.103] cross section 1.96 [0.077] 11.4 ±0.25 [0.449 ±0.010] 61.6 max [2.426] Auxiliary pump shaft length Spline data Number of teeth : 13 Pitch fraction : 16/32 Pressure angle : 30 Pitch- : 20.638 [0.813] Typ of fit : Fillet root side per : Ansi B92.1-1996 class 6 Min active spline length 12.4 mm P301 186 Specifications Option Spline Torque rating 1 maximum torque Nm [lbf in] H3 13 teeth, 16/32 pitch 395 [3500] 1) For definitions of maximum torque values, refer to: Basic Information Manual 11062168, section Shaft Torque Ratings and Spline Lubrication. T000 152E C Caution Standard pad cover is installed only to retain coupling during shipping. Do not operate pump without an auxiliary pump or running cover installed. 11069970 Rev DA Dec 2012 27

] ] H1 Axial Piston Pump, Size 089/100, Single Dimensions Auxiliary Mounting Pads Option H5, ISO 3019-1, flange 101-2 (SAE B-B, 15 teeth) 2x 146.0 ±0.35 [5.748 ±0.014] 4x 73.0 ±0.175 [2.874 ±0.007] Mounting flange surface Flange 101-2 per ISO 3019-1 312.486 ±2 [12.303 ±0.79] 296.83 ±2 [11.686 ±0.79] 107.823 + 0.13 0 [4.245 + 0.005 101.651 + 0.076 0 0 [4.002 + 0.003 0 R 0.8 max. [0.031] 19.8 [0.780] Thread : M12x1.75-6H THD Depth : 20.0 [0.787] min. 4x O-ring seal required ref 94.92 [3.737] I.D. x 2.62 [0.103] cross section 1.96 [0.077] 11.4 ±0.25 [0.449 ±0.010] 61.62 [2.426] Auxiliary pump shaft length Spline data Number of teeth : 15 Pitch fraction : 16/32 Pressure angle : 30 Pitch- : 23.813 [0.938] Typ of fit : Fillet root side per : Ansi B92.1-1996 class 6 Min active spline length 14.3 mm P301 187 Specifications Option Spline Torque rating 1 maximum torque Nm [lbf in] H5 15 teeth, 16/32 pitch 693 [6130] 1) For definitions of maximum torque values, refer to: Basic Information Manual 11062168, section Shaft Torque Ratings and Spline Lubrication. T000 153E C Caution Standard pad cover is installed only to retain coupling during shipping. Do not operate pump without an auxiliary pump or running cover installed. 28 11069970 Rev DA Dec 2012

Dimensions Auxiliary Mounting Pads Option H6, ISO 3019-1, flange 127-4 (SAE C, 14 teeth) 4x 114.5 ±0.35 [4.508 ±0.014] 8x 57.3 ±0.175 [2.254 ±0.007] Mounting flange surface Flange 127-4 per ISO 3019-1 314.907 ±2 [12.398 ±0.79] 299.02 ±2 [11.772 ±0.79] 22.5 [0.886] 90.5 ± 0.175 [3.563 ± 0.007] 181.0 ± 0.35 [7.126 ± 0.014] 134.06 + 0.13 0 [5.278 + 0.005 0 127.0 + 0.076 0 [5.002 + 0.003 0 ] ] Thread : M12 Depth : 21.0 [0.823] min. 4x Thread : M16 Depth : 25.0 [0.984] min. 2x O-ring seal required ref 120.32 [4.737] I.D. x 2.62 [0.103] cross section 1.96 [0.077] 13.5 ±0.25 [0.531 ±0.010] 63.81 [2.512] Auxiliary pump shaft length Spline data Number of teeth : 14 Pitch fraction : 12/24 Pressure angle : 30 Pitch- : 29.633 [1.167] Typ of fit : Fillet root, side fit per : Ansi B92.1-1996 class 6 min active spline length 17.8mm P301 188 Specifications Option Spline Torque rating 1 maximum torque Nm [lbf in] H6 14 teeth, 12/24 pitch 816 [7220] 1) For definitions of maximum torque values, refer to: Basic Information Manual 11062168, section Shaft Torque Ratings and Spline Lubrication. T000 154E C Caution Standard pad cover is installed only to retain coupling during shipping. Do not operate pump without an auxiliary pump or running cover installed. 11069970 Rev DA Dec 2012 29

Charge Pump Charge Pump Charge pump sizing/selection In most applications a general guideline is that the charge pump displacement should be at least 10 % of the total displacement of all components in the system. Unusual application conditions may require a more detailed review of charge flow requirements. Please refer to BLN-9885, Selection of Drive line Components, for a detailed procedure. System features and conditions which may invalidate the 10 % guideline include (but are not limited to): Continuous operation at low input speeds (< 1500 min -1 (rpm)) High shock loading and/or long loop lines High flushing flow requirements Multiple Low Speed High Torque motors High input shaft speeds Contact your Sauer-Danfoss representative for application assistance if your application includes any of these conditions. Charge pump flow and power curves Charge pressure: 20 bar [290 psi] Viscosity and temperature: 11 mm 2 /s [63 SUS] 80 C [180 F] Charge pump flow 27 100 Charge pump power requirements 24 90 14.0 13.0 10 21 80 12.0 9 US gal/min 18 15 12 9 6 3 1 l/min 70 60 50 40 30 20 10 0 24 cm 3 [1.46 in 3 /rev] 500 1500 1000 2000 Speed min -1 (rpm) 20 cm 3 [1.22 in 3 /rev] 2500 3500 3000 4000 P301 206 11.0 10.0 9.0 8.0 HP 7.0 6.0 5.0 4.0 3.0 2.0 1.0 Kw 8 7 6 5 4 3 2 1 0 500 1500 1000 2000 Speed min -1 (rpm) 24 cm 3 [1.46 in 3 /rev] 20 cm 3 [1.22 in 3 /rev] 2500 3500 3000 4000 P301 207 30 11069970 Rev DA Dec 2012

Notes Notes 11069970 Rev DA Dec 2012 31

Installation Drawings Port Description System port B 25.4 450 bar Split flange boss per ISO 6162 M12 x 1.75 20 min. full thread depth Servo gauge port M4 Port ISO 11926-1 - 7 /16-20 21.0 max. clearance dia for fitting Connector : Deutsch DT04-2P Case pressure port Port ISO 11926-1 - 1 /16-12 48.0 max. clearance dia for fitting CCW Rotation CW Rotation System port A 25.4 450 bar Split flange boss per ISO 6162 M12 x 1.75 20 min. full thread depth Charge inlet port S Port ISO 11926-1 - 1 5 /8-12 69.0 max. clearance dia for fitting Case drain port L4 Port ISO 11926-1 - 1 1 /16-12 48.0 max. clearance dia for fitting System A gauge port MA Port ISO 11926-1 - 9 /16-18 28.0 max. clearance dia for fitting P301 189 Port description Port Description Sizes A System port A 25.4 B System port B 25.4 E Charge filtration port, from filter 7 /8-14 F Charge filtration port, to filter 7 /8-14 L2 Case drain port 1 1 /16-12 L4 Case drain port 1 1 /16-12 MA System A gage port 9 /16-18 MB System B gage port 9 /16-18 M3 Charge gage port, after filtering 9 /16-18 M4 Servo gage port 7 /16-20 M5 Servo gage port 7 /16-20 M14 Case gage port 7 /16-20 S Charge inlet port 1 5 /8-12 T301 086E Please contact Sauer-Danfoss for specific installation drawings 32 11069970 Rev DA Dec 2012

Installation Drawings Port Description System B gauge port MB Port ISO 11926-1 - 9 /16-18 28.0 max. clearance dia for fitting Charge pressure port Port ISO 11926-1 - 5 /16-24 Case gauge port M14 Port ISO 11926-1 - 7 /16-20 21 max. clearance dia for fitting (EDC, FNR, NFPE) Optional Charge filtration port F Port ISO 11926-1 - 7 /8-14 to filter 42.0 max. clearance dia for fitting Optional Charge filtration port E Port ISO 11926-1 - 7 /8-14 from filter 42.0 max. clearance dia for fitting Case pressure port Port ISO 11926-1 - 1 1 /16-12 48.0 max. clearance dia for fitting Connector : Deutsch DT04-2P Servo gauge port M5 Port ISO 11926-1 - 7 /16-20 21.0 max. clearance dia for fitting Charge pressure port Port ISO 11926-1 - 5 /16-24 Case drain port L2 Port ISO 11926-1 - 1 1 /16-12 48.0 max. clearance dia for fitting Charge gauge port M3 Port ISO 11926-1 - 9 /16-18 28.0 max. clearance dia for fitting after filtering P301 190 Please contact Sauer-Danfoss for specific installation drawings 11069970 Rev DA Dec 2012 33

Installation Drawings Dimensions Servo gauge port M4 Port ISO 11926-1 - 7 /16-20 21.0 max. clearance dia for fitting System port B 25.4 450 bar Split flange boss per ISO 6162 M12x1.75 20 min. full thread depth Connector : Deutsch DT04-2P 295.3 ±2.0 [11.63 ±0.08] 228.515 + 0.6 0.5 [8.997 + 0.024 0.020 ] 228.015 + 0.6 0.5 [8.977 + 0.024 0.020 ] 162.7 ±1.0 [6.406 ±0.04] 144.3 ±1.0 [5.68 ±0.04] B Mounting flange surface Flange 127-4 per ISO 3019-1 41.7 ±1.0 [1.64 ±0.04] Case pressure port Port ISO 11926-1 - 1 1 /16-12 48.0 max. clearance dia for fitting 161.3 ±1.0 [6.35 ±0.04] Z 134.5 ±1.0 [5.30 ±0.04] 112.6 ±1.0 [4.43 ±0.04] 69.0 + 0.2 0.1 [2.717 + 0.004 0.008 ] 71.6 ±1.0 [2.82 ±0.04] 69.0 + 0.2 0.1 [2.717 + 0.004 0.008 ] (4x)27.8 ±0.25 [1.09 ±0.01] (8x)13.9 ±0.25 [0.55 ±0.01] C C D B 12.45 ±0.25 [0.49 ±0.01] 1.5 ±0.7 x 45 ±5 [0.059 ±0.028 x 45 ] R 0.8 max. [0.031] 28.8±1.0 [1.134 ±0.04] 26.0 ±0.1 [1.02 ±0.005] 31.1 ±0.8 [1.23 ±0.03] Shaft to be paint free 127.0 0 0.05 [5.0 0 0.002 ] Charge inlet port S Port ISO 11926-1 - 1 5 /8-12 69.0 max. clearance dia for fitting (8x) 28.6 ±0.25 [1.13 ±0.01] System port A 25.4 450 bar Split flange boss per ISO 6162 M12x1.75 20 min. full thread depth (4x) 57.2 ±0.25 [2.25 ±0.01] 50.0 ±0.2 [1.97 ±0.01] W B-B (2x) D 15.0 ±0.2 [0.591 ±0.08] Case drain port L4 Port ISO 11926-1 - 1 1 /16-12 48.0 max. clearance dia for fitting 147.7 ±1.0 [5.81 ±0.04] C-C 95.9 ±0.2 [3.78 ±0.01] 48.1 [1.890] 7.94 ±0.8 [0.313 ±0.03] Coupling must not protrude beyond this point D-D 92.0 ±0.2 [3.62 ±0.01] Shaft LC Shaft LC Shaft LC P301 191 Please contact Sauer-Danfoss for specific installation drawings 34 11069970 Rev DA Dec 2012

H1 Axial Piston Pump, Size 089/100, Single Installation Drawings Dimensions Y Servo gauge port M5 Port ISO 11926-1 - 7/16-20 21.0 max. clearance dia for fitting 162.7 ±1.0 [6.41 ±0.04] 144.3 ±1.0 [5.68 ±0.04] Connector : Deutsch DT04-2P View Z Charge pressure port Port ISO 11926-1 - 5/16-24 139.2 ±1.0 [5.48 ±0.04] 25.7 [1.01] G 99.0 ±1.0 [3.90 ±0.04] X G Case drain port L2 Port ISO 11926-1 - 1 1/16-12 48.0 max. clearance dia for fitting 111.7 ±1.0 [4.40 ±0.04] 152.7 [6.01] Approximate center of gravity Approximate center Charge gauge port M3 of gravity Port ISO 11926-1 - 9/16-18 28 max. clearance dia for fitting after filtering G-G Shaft CL W 91.5 ±0.2 [3.60 ±0.01] 15 F E E Charge filtration port F Port ISO 11926-1 - 7/8-14 42.0 max. clearance dia for fitting to filter 248.0 ±1.0 [9.76 ±0.04] 249.5 ±1.0 [9.82 ±0.04] fittin 101.9 ±1.0 [4.01 ±0.04] g E-E 15 Charg e filtra Port tion 42.0ISO 11926 port E -1-7 m a from filter x. clearan /8-14 ce dia for Charge filtration port E Port ISO 11926-1 - 7/8-14 42.0 max. clearance dia for fitting from filter fittin g 102.1 ±1.0 [4.02 ±0.04] F 55.5 ±1.0 [2.19 ±0.04] 10.5 ±1.0 [0.41 ±0.04] 70.5 ±1.0 [2.78 ±0.04] Case gauge port M14 Port ISO 11926-1 - 7/16-20 21 max. clearance dia for fitting Char Port ge filtratio 42.0ISO 1192 n port to filt max. cle6-1 - 7/8-1F er 4 aranc e dia for System B gauge port MB Port ISO 11926-1 - 9/16-18 28.0 max. clearance dia for fitting 243.4 ±1.0 [9.58 ±0.04] 128.4 ±2.0 [5.06 ±0.08] 64.2 ±1.0 [2.53 ±0.04] 82.2 ±1.0 [3.24 ±0.04] P301 192 F-F Charge pressure construction port Port ISO 11926-1 - 5/16-24 View Y 209 max [8.23] 112.4 ±1.0 [4.43 ±0.04] 1.11 [0.044] 187.3 ±1.0 [7.37±0.04] 161.3 ±1.0 [6.35 ±0.04] 134.6 ±1.0 [5.30 ±0.04] 112.6 ±1.0 [4.43 ±0.04] 41.7 ±1.0 [1.64 ±0.04] Case pressure port Port ISO 11926-1 - 11/16-12 48.0 max. clearance dia for fitting mm [in] P301 193 Please contact Sauer-Danfoss for specific installation drawings 11069970 Rev DA Dec 2012 35

Installation Drawings Dimensions System A gauge port MA Port ISO 11926-1 - 9 /16-18 28.0 max. clearance dia for fitting View W 228.0 ±1.0 [8.98 ±0.04] View X mm [in] 70.5 ±1.0 [2.776 ±0.04] CCW Rotation CW Rotation (4x) 57.25 ±0.25 [2.25 ±0.01] 4x 30.0 + 0.3 [1.181 + 0.010] other side screw head space (4x) 57.25 ±0.25 [2.25 ±0.01] 4x 14.34 + 0.3 0.1 [0.565 + 0.012 0.004 ] P301 194 Please contact Sauer-Danfoss for specific installation drawings 36 11069970 Rev DA Dec 2012

Installation Drawings Dimensions Controls Electric Displacement Control (EDC), option A2 (12 V)/A3 (24 V) Connector : Deutsch DT04-2P mm [in] 209 ±2.0 max [8.23 ±0.079] 128.4 ±2.0 [5.055 ±0.079] 64.2 ±1.0 [2.528 ±0.039] Case gauge port M14 Port ISO 11926-1 7 /16-20 21 max clearance dia for fitting Mounting flange 82.2 ±1.0 [3.24 ±0.04] 187.3 ±2.0 [7.37 ±0.08] 2x 161.3 ±1.0 [6.35 ±0.04] Connector : Deutsch DT04-2P 2x 144.3 ±1.0 [5.68 ±0.04] P301 195 Shaft LC Electric Displacement Control (EDC), with manual override, option A4 (12 V)/A5 (24 V) Connector : Deutsch DT04-2P Case gauge port M14 Port ISO 11926-1 7 /16-20 21 max clearance dia for fitting 209.0 max [8.228] 128.4 ±2.0 [5.055 ±0.079] 64.2 ±1.0 [2.528 ±0.039] 82.2 ±1.0 [3.24 ±0.04] Mounting flange 187.3 ±2.0 [7.37 ±0.08] 2x 161.3 ±1.0 [6.35 ±0.04] Connector : Deutsch DT04-2P 2x 144.3 ±1.0 [5.68 ±0.04] P301 196 Shaft LC Please contact Sauer-Danfoss for specific installation drawings 11069970 Rev DA Dec 2012 37

Installation Drawings Dimensions Controls Forward-Neutral-Reverse (FNR) with manual override, option A9 (12 V)/B1 (24 V) Connector : Deutsch DT04-2P mm [in] Case gauge port M14 Port ISO 11926-1 7 /16-20 21 max clearance dia for fitting 209.0 max [8.228] 128.4 ±2.0 [5.055 ±0.079] 64.2 ±1.0 [2.528 ±0.039] 82.2 ±1.0 [3.24 ±0.04] Mounting flange 187.3 ±2.0 [7.37 ±0.08] 2x 161.3 ±1.0 [6.35 ±0.04] Connector : Deutsch DT04-2P 2x 144.3 ±1.0 [5.68 ±0.04] P301 197 Shaft LC Non Feedback Proportional Electric control (NFPE), with manual override, option A8 (12 V)/B8 (24 V) Connector : Deutsch DT04-2P Case gauge port M14 Port ISO 11926-1 7 /16-20 21 max clearance dia for fitting 209.0 max [8.228] 128.4 ±2.0 [5.055 ±0.079] 64.2 ±1.0 [2.528 ±0.039] Mounting flange Plug removing can cause contamination issues 82.2 ±1.0 [3.24 ±0.04] 111.2 [4.38] 187.6 ±2.0 [7.39 ±0.79] 2x 161.2 ±1.0 [6.35 ±0.04] Connector : Deutsch DT04-2P 2x 144.3 ±1.0 [5.68 ±0.04] P301 198 Shaft CL Please contact Sauer-Danfoss for specific installation drawings 38 11069970 Rev DA Dec 2012

Installation Drawings Dimensions Control connector CC1 Deutsch DTM04-12P -A- Paint free Plug removing can cause contamination issues Control connector CAN Deutsch DTM04-3P Paint free For using the connector the plug may be removed 208.9 ±2.5 190.5 ±1.2 2x 187.1 ±1.2 Controls Automotive control (AC) with manual override, option A7 (12 V)/C2 (24 V) V Shaft LC 61.2 ±0.8 61.2 ±0.8 30.2 ±0.8 V Control connector CC2 Deutsch DTM04-12P -B- Paint free Control connector CCC3 Deutsch DT06-2S Paint free For using the connector the plug may be removed Control manual override C2 Depressing the plunger mechanically moves the control spool. Actuation allows full stroke pump response as per coil and rotation dependent control logic. Control manual override C1 Depressing the plunger mechanically moves the control spool. Actuation allows full stroke pump response as per coil and rotation dependent control logic. 89.2 ±0.8 Control connector CC1 Deutsch DTM04-12P -A- Paint free Mounting flange 209 max Control connector CAN Deutsch DTM04-3P Paint free For using the connector the plug may be removed Control connector CC2 Deutsch DTM04-12P -B- Paint free mm PPU wire harness is factory installed to speed sensor P700 52 604 Please contact Sauer-Danfoss for specific installation drawings 11069970 Rev DA Dec 2012 39

Installation Drawings Dimensions 2x Wrench size 5 Displacement limiters Displacement limiters, option B 2x 139.6 ±1.0 [5.50 ±0.039] 140.0 ±2.0 [5.512 ±0.079] 140.0 ±2.0 [5.512 ±0.079] mm [in] 2x 89.6 ±1.0 [3.53 ±0.039] 2x Wrench size 17 P301 199 Please contact Sauer-Danfoss for specific installation drawings 40 11069970 Rev DA Dec 2012

Installation Drawings Dimensions Filtration Suction filtration, option L mm [in] 228.515 +0.6 0.5 [8.997 +0.024 0.020 ] (4x) 57.2 ±0.25 [2.252 ±0.01] Charge pressure port Port ISO 11926-1 5 /16-24 System B gauge port MB Port ISO 11926-1 9 /16-18 28 max clearance dia for fitting System port B 25.4 450 bar Split flange boss per ISO 6162-2 M12 x 1.75 20 min. full thread depth Charge inlet port S Port ISO 11926-1 1 5 /8-12 69.0 max clearance dia for fitting 69.0 + 0.1 0.2 [2.717 +0.004 0.008 ] (8x) 13.9 ±0.25 [0.547 ±0.01] (4x) 27.8 ±0.25 [1.094 ±0.01] 69.0 + 0.1 0.2 [2.717 +0.004 0.008 ] (8x) 28.6 ±0.25 [1.13 ±0.01] System port A 25.4 450 bar Split flange boss per ISO 6162-2 M12 x 1.75 20 min. full thread depth P301 200 Please contact Sauer-Danfoss for specific installation drawings 11069970 Rev DA Dec 2012 41

Installation Drawings Dimensions Filtration Remote full flow charge pressure filtration, option P for end cap options F5 (SAE-C PTO) 243.4 ±1.0 [9.58 ±0.039] System B gauge port MB Port ISO 11926-1 - 9 /16-18 28 max clearance dia for fitting 10.5 ±1.0 [0.413 ±0.039] 70.5 ±1.0 [2.776 ±0.039] F F 55.5 ±1.0 [2.185 ±0.039] 248.0 ±1.0 [9.78 ±0.039] 251.22 ±1.0 [9.89 ±0.039] E E Charge filtration port F Per ISO 11926-1 - 7 /8-14 to filter Charge filtration port E Per ISO 11926-1 - 7 /8-14 from filter Charge pressure construction port Port ISO 11926-1 - 5 /16-24 15 E-E 15 F-F Charge filtration port E Port ISO 11926-1 - 1 1 /16-12 42 max clearance dia for fitting from filter Charge filtration port F Port ISO 11926-1 - 1 1 /16-12 42 max clearance dia for fitting to filter 102.1 ±1.0 [4.020 ±0.039] 108.4 ±1.0 [4.268 ±0.039] P301 287 Please contact Sauer-Danfoss for specific installation drawings 42 11069970 Rev DA Dec 2012

Installation Drawings Dimensions Filtration Integral full flow charge pressure filtration with filter bypass sensor, option M, for end cap option D3 mm [in] 190.265 ±1.0 [7.491 ±0.039] 212.82 ±1.0 [8.379 ±0.039] 127.265 ±1.0 [5.010 ±0.039] Connector : Deutsch DTM04-2P Charge gauge port M6 Port ISO 11926-1 - 9 /16-18 28 max clearance dia for fitting before filter 78.75 ±1.0 [3.10 ±0.039] 41.6 ±1.0 [1.64 ±0.039] 298.1 ±1.0 [11.73 ±0.039] 306.9 ±1.0 [12.08 ±0.039] 75.236 ±1.0 [2.962 ±0.039] P301 288 Please contact Sauer-Danfoss for specific installation drawings 11069970 Rev DA Dec 2012 43

Installation Drawings Dimensions Filtration Integral full flow charge pressure filtration with filter bypass sensor, option M, for end cap option F4 (SAE-C PTO) mm [in] 198.765 ±1.0 [7.825 ±0.039] 221.32 ±1.0 [8.713 ±0.039] 135.765 ±1.0 [5.345 ±0.039] Connector : Deutsch DTM04-2P Charge gauge port M6 Port ISO 11926-1 - 9 /16-18 28 max clearance dia for fitting before filter 78.75 ±1.0 [3.10 ±0.039] 41.6 ±1.0 [1.64 ±0.039] 298.8 ±1.0 307.6 ±1.0 [11.76 ±0.039] [12.11 ±0.039] 75.986 ±1.0 [2.992 ±0.039] P301 289 Please contact Sauer-Danfoss for specific installation drawings 44 11069970 Rev DA Dec 2012

Installation Drawings Dimensions Filtration External full flow charge pressure filtration, option S for end cap option D8 or F5 243.415 ±1 [9.583 ± 0.039 CHARGE INLET PORT "S" PORT ISO 11926-1 -1 5/8-12 CLOSED WITH PLUG SYSTEM B GAUGE PORT "MB" PORT ISO 11926-1 -9/16-18 28 MAX CLEARANCE DIA FOR FITTING CHARGE PRESSURE CONSTRUCTION PORT PORT ISO 11926-1 -5/16-24 15º E-E mm [in] 70.5 ±1 [2.776 ± 0.039] CHARGE FILTRATION PORT "E" PORT ISO 11926-1 -7/8-14 42 MAX CLEARANCE DIA FOR FITTING FROM FILTER E E 55.5 ±1 [2.185 ±0.039] 102.1 ±1 [4.020 ± 0.039] CHARGE FILTRATION PORT "E" PORT ISO 11926-1 -7/8-14 42 MAX CLEARANCE DIA FOR FITTING FROM FILTER 248.015 ±1 [9.764 ± 0.039] P301 300 Please contact Sauer-Danfoss for specific installation drawings 11069970 Rev DA Dec 2012 45

Notes Notes 46 11069970 Rev DA Dec 2012

Notes Notes 11069970 Rev DA Dec 2012 47

Products we offer: Bent Axis Motors Closed Circuit Axial Piston Pumps and Motors Displays Electrohydraulic Power Steering Electrohydraulics Hydraulic Power Steering Integrated Systems Joysticks and Control Handles Microcontrollers and Software Open Circuit Axial Piston Pumps Orbital Motors PLUS+1 GUIDE Proportional Valves Sensors Steering Transit Mixer Drives Members of the Sauer-Danfoss Group: Sauer-Danfoss is a global manufacturer and supplier of highquality hydraulic and electronic components. We specialize in providing state-of-the-art technology and solutions that excel in the harsh operating conditions of the mobile off-highway market. Building on our extensive applications expertise, we work closely with our customers to ensure exceptional performance for a broad range of off-highway vehicles. We help OEMs around the world speed up system development, reduce costs and bring vehicles to market faster. Sauer-Danfoss Your Strongest Partner in Mobile Hydraulics. Go to www.sauer-danfoss.com for further product information. Wherever off-highway vehicles are at work, so is Sauer-Danfoss. We offer expert worldwide support for our customers, ensuring the best possible solutions for outstanding performance. And with an extensive network of Global Service Partners, we also provide comprehensive global service for all of our components. Please contact the Sauer-Danfoss representative nearest you. Local address: Comatrol www.comatrol.com Schwarzmüller-Inverter www.schwarzmueller-inverter.com Turolla www.turollaocg.com Valmova www.valmova.com Sauer-Danfoss (US) Company 2800 East 13th Street Ames, IA 50010, USA Phone: +1 515 239 6000 Fax: +1 515 239 6618 Sauer-Danfoss ApS DK-6430 Nordborg, Denmark Phone: +45 7488 4444 Fax: +45 7488 4400 Hydro-Gear www.hydro-gear.com Sauer-Danfoss-Daikin www.sauer-danfoss-daikin.com 11069970 Rev DA Dec 2012 Sauer-Danfoss GmbH & Co. OHG Postfach 2460, D-24531 Neumünster Krokamp 35, D-24539 Neumünster, Germany Phone: +49 4321 871 0 Fax: +49 4321 871 122 Sauer-Danfoss-Daikin LTD. Shin-Osaka TERASAKI 3rd Bldg. 6F 1-5-28 Nishimiyahara, Yodogawa-ku Osaka 532-0004, Japan Phone: +81 6 6395 6066 Fax: +81 6 6395 8585 www.sauer-danfoss.com