PRODUCT DATA SHEET. Microwave Level Gauge MRG-10

Similar documents
BM SERIES WAVE COMPACT 6.3 GHZ CW SERIES PULSE RADAR LEVEL INSTRUMENTS (6.3 GHz)

Technical Data Sheet. 3DLevelScanner

3DLevelScanner II TECHNICAL DATA SHEET

Mobrey Ultrasonic. MSP900SH Level and MSP900FH Flow Transmitters. Product Data Sheet February 2015 IP2032, Rev BA

Electro-Magnetic Flowmeters COPA-XT 2-Wire DT43

DREXELBROOK. USonic-R Series. Ultrasonic Level Measurement System. User Friendly

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

Various Technics of Liquids and Solids Level Measurements. (Part 3)

Certified according to DIN EN ISO 9001 Technical Datasheet C-Flow Coriolis Mass Flow Meter

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

key- precision Tecum cuil Ludere ipsae. Possem Precision level detection When space and price matter Pointek CLS 100

Certified according to DIN EN ISO 9001 Technical Datasheet TRICOR Series Mass Flow Meters

ISO-9001:2000 certified. EE300 Series Electromechanical Inventory Level Measuring System. Aplus Finetek Sensor, Inc.

Microcor Wireless Transmitter (MWT)

VEGAPULS PULSE RADAR FOR LEVEL MEASUREMENT VEGAPULS 60 SERIES

Sentinel LCT. Panametrics Ultrasonic Flowmeter for Liquid Custody Transfer Measurement. GE Measurement & Control Solutions. Benefits.

Chapter2. Installation

Safety instructions VEGAPULS PS62/63/66/67/68.GI/RI(*)****** IECEx BVS Ex t IIIC T Da, Da/Db, Db IP 66

Pump_TM016. Local Display. 4-20mA. PLC/DCS Case 1. Relay Output Module. 4-20mA. Modbus. Optional. Case 2. Pump. Pump PT371 PT373 PCM370

Certified according to DIN EN ISO 9001 Technical Datasheet KVO Series Vortex Flow Meter

Electronic Control Devices The European Product Catalogue 2007

MTI10 Insertion and MTL10 In-line Thermal Mass Flowmeter and Temperature Transmitter

3500/93 System Display

API Marine. BMS Presentation. Ballast Measurement Systems

How To Use A Ds340 (Dsp)

IFC 070 Technical Datasheet

Compact pressure switch Flameproof enclosure Ex d Model PCA

Plastic tube flowmeters Series PT/PS

AT500 Magnetostrictive Level Transmitter. Compact magnetostrictive liquid level transmitter for direct insertion K-TEK Products

SM6 Series Circuit Breaker Monitors CONSOLIDATED. Electronics, Inc. MONITORING THE FUTURE

and Accelerometers

T U R B I N E G A S M E T E R

ULTRASONIC THICKNESS GAUGE TT100/110/120/130

Easily installed and simple to set up, Flow Pulse uses an acoustic technique never before seen in flow measurement to deliver reliable results across

Inductive sensor NI10-M18-Y1X-H1141

Product Data. Model 575 Series Submersible Level Transmitters ELECTRONIC PRESSURE MEASUREMENT PRODUCTS DESCRIPTION FEATURES APPLICATIONS

Level Plus. Magnetostrictive Liquid-Level Sensors with Temposonics Technology. M-Series Model MR Transmitter with Analog Output.

APPLICATION NOTE ULTRASONIC CERAMIC TRANSDUCERS

SEISMIC VELOCITY TRANSDUCER T1-40

Repeaters and Mimics Data Sheet

Air Sensor. SAC Ex. Manual ATEX. AQ Elteknik AB

Flow switches Series AD/VH

Technical Data. Dimensions

How To Use A Flowmeter

Technical Information RIA14

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

Morrison Bros. Co. General Product Specifications

Ferrostat Speed Sensor Series DSF Explosion Proof Versions EEx

Safety instructions VEGAFLEX FX8*(*).FC/ O****A/H*****

Differential-Hall-Effect based Sensors Series A5S

Regards from the Team at Rheology Solutions.

High Temperature Acceleration System Bently Nevada* Asset Condition Monitoring

713 Open Channel Flowmeter and Transmitter. All-in-one package for open channel flow measurement.

Level Switch LBFS. Technical Data. ATEX data Internal inductivity Li < 10 μh Internal capacity Ci < 43 nf Barrier data. Sensor

2.24. Pump Controller 704. Data Sheet

Triple Waveband Infra-Red Flame Detection

Micro Motion 3098 Gas Specific Gravity Meter

Smart Electromagnetic Flowmeter Open channel Flowmeter Detector

Toroidal Conductivity Sensor

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Non-invasive CLAMP-ON ultrasonic flowmeter for liquids

COMBIMASS. Technical Data COMBIMASS eco-bio +

Instruction Manual. T3111 T3111L T3111P T3111Ex

THE WORLD'S FIRST WIRELESS GUIDED WAVE RADAR

Series DFMT Digital Paddlewheel Flowmeter

Interface Level And Point Level Analyzers & Sensors

USB-500 Series Stand-Alone, Low-Cost Data Loggers

FLARE MONITORS FLARE MONITOR (FM) PILOT MONITOR (PM) FLAME INTENSITY (FI)

SELECTION, APPLICATION AND MAINTENANCE

CORONA E / FLYPPER ELECTRONIC METER MULTI-JET

Power consumption (kw)

Typical Aluminum GFM Mass Flow Meter

Electronic pressure switch with display Model PSD-30, standard version Model PSD-31, with flush diaphragm

For Multi-Parameter Meters see mvx

Technical Specifications: The specifications represent a particular hardware platform. Application-specific software is provided.

SELECT MOUNT MONITOR

Magnetic field sensor for pneumatic cylinders BIM-INT-Y1X-H1141

Model 3051 Pressure Transmitter with HART Protocol

Guidelines for Choosing and Installing Radar in Stilling Wells and Bypass Chambers

Centro-Matic Automatic Lubrication Systems System Controls

S300 Series Dust Monitors

Stand Alone POTS Fiber Optic System. P31372 Station (Subscriber) Unit P31379 Remote (Exchanger) Unit. Description & Installation

Rosemount 333 HART Tri-Loop

USB-500/600 Series Low-Cost Data Loggers and Accessories

BR LD GHz Pulse Radar Level Transmitter. Overview. BR LD20 is a 2-wire, 5.8GHz pulse radar level transmitter for

Mobrey open channel flow measurement systems

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

T1-40 T1-40BF T1-40V T1-38 T1-38BF T1-38V

Rosemount 333 HART Tri-Loop

MTII4200 level Transmitter Installation, Operation & Maintenance Instructions

Explosion proof enclosures

Technical Data. Dimensions

Reprinted from Winter2010 / lngindustry /

Thermal flow sensors TA10-ZG8c and TA10-ZG9c for exact and stable, long-term measuring of lower flow velocities (Laminar Flow)

JNIOR. Overview. Get Connected. Get Results. JNIOR Model 310. JNIOR Model 312. JNIOR Model 314. JNIOR Model 410

Thermal Mass Flow Meter (Series MST)

APPLICATION NOTE AP050830

Series 8146/5-V37 and Series 8150/5-V37

How To Read A Pipe From A Sensor

HYDRUS ULTRASONIC METER

Transcription:

PRODUCT DATA SHEET Microwave Level Gauge MRG-1

Microwave Level Gauge MRG-1 1. Advanced performance The measuring principle is based on Time Flight impulse Radar technology that uses very short pulses. Non contact measuring Non mechanical moving parts High reliability, Easy maintenance High sensitivity Density, Pressure and Temperature independent Loop Power System (2-wire) 4-2mA output and HART output integrated Wide antenna range Interactive Windows-based setup software Built-in display/ keyboard Transmitting pulse Receiving pulse Pulse sequence 1ns 1μs t 2. Features 1) Principle Time Flight Impulse Radar Technology 2) Wide Measuring Range Up to 2m Max. 3) Variety of Antennas 4inch Cone Antenna / 6inch Cone Antenna 8inch Cone Antenna PFA Rod Antenna (Long/Short inactive) d=c* t 2 4) Easy Configuration Menu driven 4-keys input Graphical HART Configuration 1

3. Measuring principle MRG-1 measures liquid levels by transmitting low energy radar pulses towards the liquid surface and receiving the radar echoes. The travel time for the radar pulse is proportional to the distance between the gauge and the surface. Upon reception, microprocessors and intelligent software in the gauge head analyze the echoes and transform them into level output data. The radar pulse is virtually unaffected by the tank content and atmosphere, temperature or pressure. Thus, radar measurement is proven to be the most reliable gauging method in most applications. Furthermore, maintenance requirements are in fact zero that as no part of the gauge is in physical contact with liquid. All this makes MRG-1 very well suited for storage and buffer tanks in the chemical and water industry. 4. Applications MRG-1 is appropriate for calm surface liquid. If you intend to use MRG-1 to measuring turbulence surface liquid, you had better to use still pipe in order to keep calm surface. MRG-1 is appropriate for storage tanks or buffer tanks that they have relatively calm surface. Chemical and petroleum Pharmacy Food and beverage Also it will be available in Water industrial such as river intake gate, Water supply, Sewage water treatment plant Hydraulic power station. If you intend to use MRG-1 to measuring turbulence surface liquid, you had better to use still pipe in order to keep calm surface. Refer right figure. 2

5. System Bar graph [%] Measured value MRG-1 uses 2-wire system, which means both signal and power are available on same wiring. MRG-1 is certified as intrinsically safety instrument, ESC ENT m Unit ma % ft m then if you intend to use it in hazard area, intrinsically safety isolator should be used. All of data is displayed by 5-digit LCD display on main body and changed items by 4 configuration buttons easily. Also it is possible to operate Interactive Windows-based setup software on PC. Ex Non Ex Isolator HART modem Control system Laptop PC 3

6. Measuring Measuring performance will be decided by products nature (dielectric constant), surface conditions and antenna size. In generally, the liquid, which has high dielectric constant number such as water, is easily to measure, and calm surface liquid is the same. On the contrary, low dielectric constant liquid, turbulence surface or forming surface and dirty antenna conditions are relatively difficult to measure. Even so if you choose right antenna, it is possible to measure in most of case. Type Antenna Targeting MRG-1A-5TH MRG-1A-5TR-S MRG-1A-5TR-L 4,6,8 Cone Rod antenna short Rod antenna long Tank application Low tank nozzle High tank nozzle Almost all of liquid may be classified as below 3 types. Below table and graphs show suitable antenna, products and range. a:oil, Hydraulic carbon, Mainly petroleum industry(εr=1.9~4.) b:alcohol, Acid(εr=4.~1) c:water base liquid(εr>1) Antenna Measuring Distance (reference) (m) Rod 4"Cone 6"Cone 8"Cone a b c a b c a b c a b c 1 1 1 1 Calm surface 2 2 2 2 (m) Rod 4"Cone 6"Cone 8"Cone a b c a b c a b c a b c 1 1 1 1 Turbulent surface 2 2 2 2 4

7. Antenna type Antenna is only a part, which is exposed in tank inside, and you should choose proper antenna that suits to your demand. 7-1. Cone antenna Cone antenna is available for both original tank or vessel and pipe installation. The size of antenna are extending from 4 inch to 8 inch, and the only materials which is exposed in tank inside are consisted of SUS-316L and PTFE sealing and O rings. Thanks to MRG-1 unique flange clamp solution, you can use your existing flange as process connection. 148 172 SUS316: Antenna adaptor Viton:O-ring PTFE:Seal 238 φ215 φ265 φ52 16 φ152 φ92 226 SUS316:Antenna 4B Cone antenna 346 φ14 6B Cone antenna φ188 8B Cone antenna 5

7-2. Rod antenna The Rod antenna is made of Teflon (PFA) and stainless steel, which makes it easy to clean and resistant to aggressive chemicals and conditions. It has inactive length of 1mm and 25mm to ensure that measurements are unaffected by the mounting nozzle or thick flower. Extention length Nozzle height *Extention 6

8. Mechanical Installation 1mm or more MRG-1 shall be mounted on tank nozzle or pipe easily. To ensure performance you should install gauge properly as bellow. Antenna tip Antenna tip must be bellow nozzle. Half power beam width Antenna should be kept horizontally. Inside of microwave transmitting area might be clear. Set the gauge to keep away from tank wall as recommended dimension in the measuring ranges. To choose bigger size antenna as you can because big size antenna will be better to gain weak microwave echo in bad conditions. Size of microwave transmitting area * ( -3dB down angle) Beam angle Distance 5m 1m 15m Distance (m) Diameter (m) Antenna 4B 6B 8B type Cone Cone Cone Rod Beam angle 34 22 17 3 5 2.9 1.9 1.5 2.7 1 5.8 3.8 3. 5.4 15 8.8 5.7 4.4 8. 2 11.7 7.6 5.9 1.7 9. Electrical Installation + + - - Terminal block 2m ESC ENT LCD Keys MRG-1 is 2-wire system, which means both signal and power are available on same wiring. The power source voltage is 16-36VDC in non-hazardous area, and 16-28VDC in hazardous area might be available. For application twisted and sealed cable is recommended. MRG-1 is certified as intrinsically safety instrument. Then if you intend to use it in hazardous area, you should use with intrinsically safety isolator. In that case electrical parameters are 28VDC, 93mA and.65w as maximum. Ground terminals Also, if you want to know more detail conditions, please refer installation guidance. 7

SPECIFICATIONS 1.General Measuring principle Time Flight impulse Radar technology Operating frequency 5.8 GHz Half power beam angle Rod antenna: 3deg., Cone antenna 4 : 34deg., 6 : 22deg., 8 : 17deg. Microwave output power Max 1μW Reference conditions Free space reflection from metal surface, ambient temperature 25, atmospheric pressure 2.Display / Configuration Local display 5 digit LCD display with 4 configuration buttons. Level, Ullage, Volume, Current or Amplitude output HART hand held communicator Rosemount Communicator RS275, just display not for configuration PC Remote configuration Windows base setup and configuration software 3.Electrical Power supply Loop powered 16-36 VDC (16-3VDC in Ex applications) Output Analog DC4-2mA +HART Output variable Level, Ullage in m or ft. Volume in %, Amplitude in db. Signal on alarm Hold, Low(3.9mA), High(22mA) Cable entry 2-M2 1.5(Applicable Cable diameter : 6.5-9.mm) 4.Mechanical Antenna Rod antenna, Cone antenna 4, 6, 8 Antenna material exposed to tank Rod antenna: PFA and SUS(316L,ext.version) Cone antenna: 4, 6, 8 SUS(316L), PTFE, Viton Antenna dimension See page 5 and 6 Housing / Enclosure Casting Aluminum Flange On request or customer supply Mass 3.3--4.3Kg, depend on antenna size Height above flange 23 mm 5.Environment Condition Max. pressure 1 bar. (145 psi) Ambient temperature -2 to 7 (-4 F to 158 F), LCD Display 2 to 7 Storage temperature -4 to 8 (-4 F to 176 F) Tank inside temperature -2 to 15 (-4 F to 32 F) Ingress protection IP65 Vibration resistance IEC 68-2-6/1G Ex. Approval ATEX II 1/2GD Ex ia IIC T4 (for Cone antenna) ATEX II 2G EX ia IIC T4 (for Rod antenna) (Ui=28V / Ii=93mA / Pi=65mW / Li H / Ci F / Group ⅡC) 6.Measuring Performance Instrument accuracy +/- 1mm Repeatability +/- 1mm Update interval 1 Second Measuring range Depend on Antenna type and products nature, see diagram at page 4 8

Required parameters for Inquiry AA. Tank Information 1) Tank Name : 2) Tank Q ty : tank(s) 3) Tank Dimension : If possible, send us DWG of tank. Tank Shape : Spherical, Cylindrical, Horizontal, Other ( ) Tank Volume : m3 or L Tank Height : m Tank Diameter : m % Position : LV m (=4mA) 1% Position : LV m (=2mA) 4) Agitator Type : 5) Inner Obstruction : Heater coil / Baffles / Pipes / or others ( ) 6) Mounting Flange Rating : 1% Level m Tank Diameter m Tank Height m Tank Volume m3 % Level m BB. Liquid Information 1) Liquid Name : (main component) 2) Dielectric Constant : εr = (if possible) 3) Temperature : C deg.~ C deg. 4) Pressure : Mpa ~ MPa 5) Corrosive Requirement : SUS316L / PFA/PTFE only 6) Surface Condition : Calm / Foamy / Turbulent CC. Extra Information 1) Purpose of process : 2) Existing Level instruments : (if any) 3) Any other problems at Level : 9

1 Blank

2-16-46, Minami-kamata, Ohta-ku, Tokyo 144-8551 Japan Measurement Systems Company Phone:+81-()3-3737-8664 Fax :+81-()3-3737-8665 MAR213/PDS3H 11