KOG LN. Low Noise Chilled Water Cassettes Models 9, 12 & to 5.7kW. 1.6 to 4.6kW. 290 to 830 m 3 /h

Similar documents
1-Way Chilled Water Cassettes KCO 60, 90 & 120. Technical Brochure. TM KCO-W.1GB Date : November 2005 Supersedes : None

ECOCIAT. Domestic hot water heat recovery unit

CoolTop. A unique water cooled air-conditioning unit for server room cooling from the top AC-TOPx-CW-240/60

Product catalog UNT-PRC011-E4

Under sill units. Type FSL-B-ZAS

technical data air conditioning systems RXS E (single phase) FBQ-B8V1-B8V3B Split Heat Pump Condensing Units Split Sky Air

Elegant ECM. ELEGANT ECM air conditioners allow. The range is made up of 12 models: Ceiling Air Conditioner

hore PRODUCT CATALOGUE nd Offsh arine an ms for Ma & Refrig AUTONOMOUS AIR CONDITIONERS HV VAC &

SINGLE PACKAGE VERTICAL AIR CONDITIONERS

squrboxbox heat recovery squrboxbox I technical information

Chilled Water Fan Coil Unit

marine/bespoke split applications

Technical data. Danfoss DHP-A

Element D Services Heating, Ventilating, and Air Conditioning

RKE. Heat recovery unit. heat recovery unit RKE. from 200 to 6800 m 3 /h. General features

Product catalog UNT-PRC017-E4

COADIS LINE 900. Cassette comfort units. the new generation of water loop cassette comfort units, for installation in suspended ceilings

SWIMMING POOL AIR-HANDLING UNITS KU-DB Series

CoolTeg Plus Chilled Water (CW) version: AC-TCW

M SERIES REFRIGERANT COIL MODULE REFRIGERANT COILS for R-22, R-407C, R-410A

Water Fired Chiller/Chiller-Heater. WFC-S Series: 10, 20 and 30 RT Cooling


Air Conditioners Technical Data

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

TWE+TTA TWE+TWA T.R.

Chilled Water Fan Coil Unit. Model:HFCA Size 03~14

Cool Design for Homes and Offices

Condensing unit type EPSILON-ECHOS LE Technical information manual

UR...3 URX CF...7 URHE CF Heat recovery unit. Heat recovery unit with refrigerant circuit( cfm)

HVAC Systems: Overview

HDA

Transformer oil cooler ALFA A02

R22. K Control. Indoor Unit. Nomenclature. Compatibility PL H 3 G K H B. Unit style Heat Pump Horse Power

QZSR Fan Coil. Key features. Specifications. Product code example Cassette Unit QZSR, QZSR

SECTION AIR CONDITIONING UNIT

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS NON-CUSTOM

ROOFTOP - HEAT PUMP UNIT. This document applies when installing into an air handler or as part of an air handling system.

LH and GH/GL Series UNIT COOLERS. Technical Bulletin: LHGH_001_ Products that provide lasting solutions.

Lesson 36 Selection Of Air Conditioning Systems

, User s Manual

Installation, operation and maintenance manual TX 35A

KONRAD. Hybrid Fancoil Series

Max primary circuit temperature 90ºC Max primary circuit temp. 90ºC Max secondary circuit temperature 45ºC Max secondary circuit temp.

The space saving solution.

COOLSIDE box R410A. conditioned server - racks for direct installation into the room INVERTER E C

The Concept. How Cassettair can benefit you. Applications. Selecting Cassettair

catalog Single Package Vertical Air Conditioners and Heat Pumps

SECTION HEATING, VENTILATION AND AIR CONDITIONING EQUIPMENT

Chilled Water Precision Air Conditioner For Critical Application

APC APPLICATION NOTE #112

SECTION MORTUARY REFRIGERATORS

RPV - RP - RA air handling units

Technical Concept. Filter Fan Unit COMPACT. Type COMPACT AC Type COMPACT EC

Split units TH with hermetic compressors

BILL OF QUANTITY FOR THE HVAC WORKS OF The Institute of space technology, near Toll Plaza (G.T. Road,) Islamabad

SERVICE MANUAL MUZ-GE25VA - E1 MUZ-GE25VAH - E1 MUZ-GE35VA - E1 MUZ-GE35VAH - E1 MUZ-GE42VA - E1 MUZ-GE42VAH - E1 MUZ-GE50VA - E1 MUZ-GE50VAH - E1

SECTION HEAT PUMPS

Ceiling Mount Air Handler Manual

HEAT PUMP FREQUENTLY ASKED QUESTIONS HEAT PUMP OUTDOOR UNIT ICED-UP DURING COLD WEATHER:

SERVICE MANUAL OUTDOOR UNIT. No. OBH590 REVISED EDITION-B. Models HFC

SIRIUX. SINGLE AND DOUBLE HIGH EFFICIENCY CIRCULATORS Heating Air-conditioning OPERATING LIMITS APPLICATIONS. 28 m 3 /h* Heads up to: Flows up to:

CE6500 Energy Recovery Ventilator

CRAC Precision climate control units for data centres

USER S MANUAL HSC-24A

Hitachi Air Conditioning. Engineered for tomorrow. Room Air Conditioning GENERAL CATALOGUE

48/50EJ,EK,EW,EY038, 044, 048 SINGLE-PACKAGE COOLING UNITS VARIABLE VOLUME CONSTANT VOLUME FACTORY-INSTALLED OPTIONAL HEAT

CADB and CADT-D / DI / DC Series

Single Package Vertical Air Conditioners. Vert-I-Pak

Air Conditioners Technical Data

Climasys Thermal Management System. Schneider Electric Universal Enclosures 2009

stainless steel pre-assembled manifolds

Topvex SX/C, Topvex TX/C. Air Handling Unit

Air Conditioners. Technical Data. Wall Mounted Unit. RX-JV/GV

INNOVATIVE SOLUTION OF DOMESTIC HEATING SPLIT TYPE SPLIT DHW INTEGRATED TYPE MONOBLOC TYPE

Liebert Hiross HPW The High Performance Wallmount Cooling Solutions for Telecom Mobile Remote Access Nodes

AIR HANDLERS AIR HANDLERS AIR HANDLERS. RHLA- High Efficiency. featuring R-22 Refrigerant. RHLL- High Efficiency

DIESEL-FUELED, BLOWN AIR, DUCTABLE HEATERS

HP switch LP switch Discharge thermo Comp. Surface thermo

Gree Solar Hybrid Hi Wall Inverter Air Conditioner

Bring the fresh in. Dedicated Outside Air Systems

Manual Code VR

Explosion-Proof Electric Unit Heaters

ModPac II 1 to 5-Ton Vertical Wall Mount Air Conditioners Models AVPA

york air-conditioning products Residential & VRF News 2015

HERZ-Thermal Actuators

PELLEXIA COMFORT ENVIRONMENT COMPATIBLE

NEW! Flexit SL4 R. Air Handling Unit with rotating recovery system Energy-efficient New control system. Patent applied for!

Cold Room & Refrigeration System (Casserole Assembly) No of units: 1

The High Performance Floormount Indoor Package Cooling Solution. Precision Cooling for Business-Critical Continuity

FOXAIR 60/50 ALL MODELS

MAC-120HE-01 Air-Cooled Chiller

EHDC. Cooling system for Data Center and server cabinets.

SMARTY 160 POWER page 4-5 SMARTY 180 / 220 XL page 4-6 SMARTY TX 250 page 4-7. SMARTY TX 160 Alu page 4-8 SMARTY TX 220 Alu page 4-9

Inverter Air Conditioning for Light Commercial Use

Low Profile Unit Cooler

Local Dealer:

YCAA-B AIR COOLED LIQUID CHILLER

Brochure EX

VertiCool Space Saver 2 to 15 tons Water-Cooled and Chilled Water

Transcription:

KOG LN Low Noise Chilled Water Cassettes Models 9, 12 & 18 1.7 to 5.7kW 1.6 to 4.6kW 290 to 8 m 3 /h

1 KOG LN 9 / KOG LN 12 / KOG LN 18 Design Features Introduction The new low noise chilled water cassettes 9 LN to 18 LN offer a comfortable air conditioning with improved acoustic performance. Their design and their small dimensions allow them to fit harmoniously Cleanable synthetic type air filter (55 % arrestance, G1 class) accessible after opening the return grille. Fan-motor assembly electrical box and control valves (optional) inside the unit, make its Centrifugal turbine with direct drive. Motor resiliently mounted and equipped with internal thermal safety device. It can be dismounted by 3 screws and disconnection from electrical supply cable by pin type connector. The chilled water cassettes sizes 9, 12 and 18 LN can be supplied with 2 types of motor : The standard AC motor of direct drive type having 6 speeds, 3 of them are factory pre-wired. The motor is suitable for nominal voltage of 2V/1ph/Hz and is equipped with a built-in normally closed thermal protection of automatic reset type. The EC motor of high efficiency and low electrical consumption type for a significant energy saving. The motor is suitable for 0-10 V input, ensuring variable speed capability. It is fitted with ECospeed3 interface card (supplied as standard) for a 3-speed optimized running. installation compatible with standard false ceiling tiles (600 x 600 Electrical connection into the standard ceiling tiles of 600 x 600 mm size. These new cassettes have been specially designed for an easy and fast installation, as well as for a great ease of maintenance with a complete access to internal components through the return air grille. The chilled water cassettes are available in 3 sizes (9 LN, 12 LN & 18 LN) and in 3 versions (2-pipe, 2-pipe/2-wire and 4-pipe). Features and benefits As a result of new motor staging, the noise level has been reduced by 4 to 6 dba at low speed. The casing to be fitted into the false ceiling has a low profile (287 mm thick). Its dimensions as well as the incorporation of mm size). The casing is made from galvanized steel sheet with thermal and acoustical insulation, eliminating condensations on the casing and providing low sound levels. The grille of RAL 9016 colour combines discharge and return with air filter; discharge manually ajustable on all four sides with possibility of closing one or two faces of discharge, return at the center. The coils are composed of copper tubes and aluminium hydrophilic fins ensuring a better condensate drainage and a better protection against corrosion. The coils of sizes 9 LN and 12 LN have 2 rows for 2-pipe and 4-pipe systems. Those of size 18 LN have 3 rows for 2-pipe and 4-pipe systems. Prepunched holes for connection with fresh air intake and connection with a stub duct to treat air of adjacent room. In this case, it becomes necessary to provide a decompression in the adjacent room to allow air return on the cassette. Easy and quick access, by simply removing the front grille, to the internal components such as the coil, the fan-motor assembly, the condensate pump, the optional regulating valve(s) and the electrical box. All connections : water, electrical, condensate drain and air vent cock are located at the same side, on the exterior of the unit. Sliding electrical box is easily accessible after removing two screws. Electrical box has a junction block provided for quick connection on terminals without screws and a multi-output autotransformer supplied for eventual change of fan speeds (on site). Condensate pump supplied as standard, can be easily reached and removed by only one screw; electrical connection by pin type connector. The condensate pump provides a manometric lift up to 600 mm. The pump is, in addition, equipped with a high security level control system : it is concerning a 3-level detection float ("On", "Off" to avoid permanent operation, and "Alarm"). Control valves (factory-supplied option) mounted inside the casing to limit the works on site and the installation costs. Flexible hoses for connection on units with or without control valves. 1 Filtration Fast connection on terminals without screws. Two cable glands are provided on the casing wall allowing to block the supply and control cables. Supply voltage : 2 V / 1 ph / Hz + Earth. Available accessories and options IRYS Diffuser the modern design of the IRYS diffuser combines aesthetics and a flat appearance to meet the architectural constraints: Perfect integration into the standard false ceiling, exterior dimensions 595x595. Metallic diffuser which keep colors over time. Epoxy paint RAL 9003 Air diffusion 360 with Coanda effect: Air diffusion in 360 avoiding any dead air zones. When the air is blown from a point near the ceiling, the air stream is pressed against the ceiling and has an improve air throw. IRYS Diffuser uses this principle of air diffusion "Coanda effect" in order to ensure a homogeneous distribution of the air in the room with a high induction rate and reduced temperatures stratification (less than 1 C). Definition of a comfort zone which eliminates air flow phenomena and temperature stratification (speed of air below 0.15m/s). Air throw: The air throw is the distance between the cassette and the points where the speed of the spread air (approximately 0.2 m/s) is not longer felt by the human body. The IRYS diffuser possesses the blowing reach of air over of 5m in HS. Easy maintenance: Quick access to the filter. Access to internal components. Easy cleaning thanks to a perfectly smooth surface. Electric heater for use with 2-pipe/2-wire system It is composed of heating elements located inside the tubes of heat exchanger and is thermally protected against abnormal rises in temperature by two thermostats : automatic reset thermostat and manual reset one. Supply voltage : 2 V / 1 ph / Hz + earth. Control valves Motorized valves, 2 ways and 3 ways with by-pass, factory-fitted option and incorporated inside the unit for 2-pipe and 4-pipe systems. Controls TRM-VP (kit), TRM-FA (kit), TAE 20 (kit), TAE 20 + SEH (kit), Aqu@Simp, Aqu@Net and IR remote control.

2 KOG LN 9 / KOG LN 12 / KOG LN 18 Advantages of Chilled Water Cassettes LN with EC motor Energy class with standard motor More efficient Models 9 LN 12 LN 18 LN FCEER 2-pipe 4-pipe FCCOP 2-pipe 4-pipe Less efficient Energy class with EC motor More efficient Models 9 LN 12 LN 18 LN FCEER 2-pipe 4-pipe FCCOP 2-pipe 4-pipe Less efficient 3-speed control interface for EC motor Aqu@Net Interface card EC motor 3 speeds 0 to 10 V ECoSpeed3

KOG LN 9 / KOG LN 12 / KOG LN 18 3 Technical Data Models 9 LN 12 LN 18 LN 2-pipe 4-pipe 2-pipe 4-pipe 2-pipe 4-pipe Nominal cooling capacity (1) W 20 20 30 30 4600 4600 Nominal heating capacity (2) W 3100 2200 40 3335 5700 4470 air flow Treated air Super High Speed (**) m 3 /h - - - - 865 865 High Speed m 3 /h 720 720 720 720 8 8 Medium Speed m 3 /h 4 4 4 4 580 580 Low Speed m 3 /h 3 3 3 3 410 410 Super Low Speed m 3 /h - - - - 290 290 Nominal water flow l/h 0 210 600 287 790 380 Water pressure drop (3) kpa 12 5 22 13 16 28 Nominal power supply 2 V / 1 ph / Hz Voltage range V 207 / 253 sound power levels (4) (measured according to ISO 9614 standard) (1) Nominal conditions : Air : 27 C/19 C wet bulb (nominal air flow in high speed). Chilled water : 7 C/12 C. (2) Nominal conditions : - In 2-pipe configuration : air : 20 C (nominal air flow in high speed); hot water : entering temperature C (nominal water flow obtained in cooling mode). - In 4-pipe configuration : air : 20 C (nominal air flow in high speed); hot water : 70 C / 60 C. (3) Water pressure drops given for the corresponding nominal water flow on cassettes without control valves. (4) Data based on units 2 tubes with AC motor (*) The sound pressure levels Lp are based on (NR) characteristic of a room having volume of 100m 3 with reverberation time of 0.5 seconds and a distance of 1 meter. (**) Super High Speed is available on EC motor only. Electrical Data 9 LN 12 LN 18 LN Lw global Lp* global Super Low Speed dba - - - - - - 35 27 23 Low Speed dba 34 26 20 34 26 20 41 33 28 Medium Speed dba 32 27 32 27 49 41 35 High Speed dba 52 42 37 42 37 57 49 43 Super High Speed (**) dba - - - - - - 60 52 46 Dimensions Casing (L x P x H) mm 571 x 571 x 287 Grille (L x P x H) mm 625 x 625 x Diffuser IRYS (L x P x H) mm 595 x 595 x 34 Packing Gross weight kg 26 27 28 28 29 29 Packed volume m 3 0.15 0.15 0.15 0.15 0.15 0.15 NR Lw global Lp* global NR Lw global Lp* global NR Models 9 LN - 2-pipe 12 LN - 2-pipe 18 LN - 2-pipe With BE Without BE With BE Without BE With BE Without BE Nominal current A 6.7 0.3 8 0.3 10.8 0.4 Fuse rating gg A 10 1 ** 10 1 ** 16 1 ** Fuse rating ASE/VDE** A 16 2 16 2 16 2 Power supply 2 V / 1 Ph / Hz Cable section* mm 2 3G1.5 3G1 3G2.5 3G1 3G2.5 3G1 Electric heater capacity W 10-1800 - 20 - Models 9 LN - 4-pipe 12 LN - 4-pipe 18 LN - 4-pipe Nominal current A 0.3 0.3 0.4 Fuse rating am** A 1 1 1 Fuse rating ASE/VDE A 2 2 2 Power supply 2 V / 1 Ph / Hz Cable section* mm 2 3G1 3G1 3G1 BE : Electric heater. * Minimum section to be adapted according to local regulations and norms. ** am or circuit breaker curve C.

4 KOG LN 9 / KOG LN 12 / KOG LN 18 Electrical Data (continued) Standard fan motor electrical data Models Fan speed 9 LN 12 LN 18 LN current (A) power (W) current (A) power (W) current (A) SLS - - - - 0.09 21 LS 0.08 20 0.08 20 0.13 MS 0.12 0.12 0.2 46 HS 0.21 0.21 0.31 71 power (W) EC fan motor electrical data Models Fan speed 9 LN 12 LN 18 LN current (A) power (W) Set Voltage (V) current (A) power (W) Set Voltage (V) current (A) power (W) Set Voltage (V) SLS - - - - - - 0,02 8 3,77 LS 0,07 8 3,77 0,07 8 3,77 0,1 9 4,45 MS 0,09 11 4,39 0,09 11 4,39 0,19 23 6,03 HS 0,2 26 6,17 0,2 26 6,17 0,33 41 7,53 SHS - - - - - - 0,4 52 8,2 Electric heater Models 9 LN 12 LN 18 LN Capacity W 10 1800 20 Thermal Performance 2-pipe system with AC motor 9 LN 12 LN 18 LN Models Air flow (m 3 /h) Air flow (m 3 /h) Air flow (m 3 /h) LS MS HS LS MS HS SLS LS MS HS SHS Water in/out Entering air temperature / HR 3 4 720 3 4 720 290 410 580 8 865 Total capacity W 1600 1900 20 20 2600 30 2200 2800 3700 4600 5151 7 C / 12 C 27 C / 47% Sensible capacity W 12 10 1800 1700 20 2900 17 21 29 38 4275 Water flow Qv l/h 280 3 0 0 4 600 380 480 6 790 884 Water pressure drop kpa 6 9 12 8 11 18 5 8 11 16 20 C / Qv 20 C Heating capacity W 2100 20 3100 2700 3200 40 2700 30 4600 5700 6100 Water pressure drop kpa 6 9 12 8 11 18 5 7 11 16 20 4-pipe system with AC motor 9 LN 12 LN 18 LN Models Air flow (m 3 /h) Air flow (m 3 /h) Air flow (m 3 /h) LS MS HS LS MS HS SLS LS MS HS SHS Water in/out Entering air temperature / HR 3 4 720 3 4 720 290 410 580 8 865 Total capacity W 1600 1900 20 20 2600 30 2200 2800 3700 4600 5151 7 C / 12 C 27 C / 47% Sensible capacity W 12 10 1800 1700 20 2900 17 21 29 38 4275 Water flow l/h 280 3 0 0 4 600 380 480 6 790 884 Water pressure drop kpa 6 9 12 8 11 18 5 8 11 16 20 Heating capacity W 1700 1900 2200 2200 20 3335 2800 30 39 4470 4600 70 C / 60 C 20 C Water flow l/h 160 180 210 200 220 290 2 290 3 380 4 Water pressure drop kpa 3 4 5 7 9 13 11 17 24 28

KOG LN 9 / KOG LN 12 / KOG LN 18 5 2-pipe system with EC motor 9 LN 12 LN 18 LN Models Air flow (m 3 /h) Air flow (m 3 /h) Air flow (m 3 /h) LS MS HS LS MS HS SLS LS MS HS SHS Water in/out Entering air temperature / HR 3 4 720 3 4 720 290 410 580 8 865 Total capacity W 1600 1900 20 1970 22 00 2200 2800 3700 4600 5151 7 C / 12 C 27 C / 47% Sensible capacity W 12 10 1800 1590 1920 2720 17 21 29 38 4275 Water flow Qv l/h 280 3 0 3 384 513 380 480 6 790 884 Water pressure drop kpa 6 9 12 8 11 26 5 8 11 16 20 C / Qv 20 C Heating capacity W 2100 20 3100 24 2910 90 2700 30 4600 5700 6100 Water pressure drop kpa 6 9 12 8 11 26 5 7 11 16 20 4-pipe system with EC motor 9 LN 12 LN 18 LN Models Air flow (m 3 /h) Air flow (m 3 /h) Air flow (m 3 /h) LS MS HS LS MS HS SLS LS MS HS SHS Water in/out Entering air temperature / HR 3 4 720 3 4 720 290 410 580 8 865 Total capacity W 1600 1900 20 20 2600 30 2200 2800 3700 4600 5151 7 C / 12 C 27 C / 47% Sensible capacity W 12 10 1800 1700 20 2900 17 21 29 38 4275 Water flow l/h 280 3 0 0 4 600 380 480 6 790 884 Water pressure drop kpa 6 9 12 8 11 18 5 8 11 16 20 Heating capacity W 1700 1900 2200 2200 20 3335 2800 30 39 4470 4600 70 C / 60 C 20 C Water flow l/h 160 180 210 200 220 290 2 290 3 380 4 Water pressure drop kpa 3 4 5 7 9 13 11 17 24 28 Acoustical Data KOG with AC motor Acoustical power per octave band (db(a)) Type Speeds 125 2 0 1000 2000 00 8000 Lw Global L p * NR* db(a) db(a) LS 26.4 27.3 28.6 23.1 25.5 18.2 9.2 33,7 26 20 KOG 09 LN MS.3 34.2 35.4 31.9 27.5 21.5 11.7 39,7 32 27 HS 37.1 43.9 47.4 45.9 44.0 33.4 22.7 51.8 46 41 LS 26.4 27.3 28.6 23.1 25.5 18.2 9.2 33,7 26 20 KOG 12 LN MS.3 34.2 35.4 31.9 27.5 21.5 11.7 39,7 32 27 HS 38.9 42.9 46.0 44.5 41.7 29.5 9.2.4 42 37 SLS 26.6 25.8.0 26.1 28.7 21.7 12.1 35,0 27 23 KOG 18 LN LS 29.9 35.0 36.1 32.6 32.9 24.1 8.1,9 33 28 MS 39.5.8 43.3 42.2.6 33.4 19.0 48,6 41 35 HS 49.7 48.4.0.1 48.9 46.2 32.2 56,9 49 43 Data based on units 2 tubes (*) The sound pressure levels Lp are based on (NR) characteristic of a room having volume of 100m 3 with reverberation time of 0.5 seconds and a distance of 1 meter. KOG with EC motor Acoustical power per octave band (db(a)) Type Speeds 125 2 0 1000 2000 00 8000 Lw Global L p * NR* db(a) db(a) LS 26.4 27.3 28.6 23.1 25.5 18.2 9.2 33,7 26 20 KOG 09 LN MS.3 34.2 35.4 31.9 27.5 21.5 11.7 39,7 32 27 HS 38.9 42.9 46.0 44.5 41.7 29.5 9.2.4 42 37 LS.6 31.1 31.2 24.9 22.7 17.0 21.0 36.5 31 25 KOG 12 LN MS.3 34.2 35.4 31.9 27.5 21.5 11.7 39,7 32 27 HS 38.9 42.9 46.0 44.5 41.7 29.5 9.2.4 42 37 SLS 26.6 25.8.0 26.1 28.7 21.7 12.1 35,0 27 23 KOG 18 LN LS 29.9 35.0 36.1 32.6 32.9 24.1 8.1,9 33 28 MS 39.5.8 43.3 42.2.6 33.4 19.0 48,6 41 35 HS 49.7 48.4.0.1 48.9 46.2 32.2 56,9 49 43 Data based on units 2 tubes (*) The sound pressure levels Lp are based on (NR) characteristic of a room having volume of 100m 3 with reverberation time of 0.5 seconds and a distance of 1 meter.

6 KOG LN 9 / KOG LN 12 / KOG LN 18 Comparison of Acoustic Performance Sizes 9 and 9 LN 55 Sound power level Lw (dba) 45 35 25 Size 9 LN 34 38 Size 9 Sizes 12 and 12 LN 20 200 0 0 0 600 700 800 Air flow (m 3 /h) Sound power level Lw (dba) 55 45 35 25 Size 12 LN 34 43 Size 12 52 20 200 0 0 0 600 700 800 Sizes 18 and 18 LN Air flow (m 3 /h) Sound power level Lw (dba) 60 55 Size 18 57 57 48 45 49 41 42 35 35 Size 18 LN 25 20 200 0 0 0 600 700 800 900 Air flow (m 3 /h)

KOG LN 9 / KOG LN 12 / KOG LN 18 7 Water Pressure Drops Size 9 LN - 2-rows - 2 circuits C D A kpa B 20 10 0 100 200 0 0 0 600 l/h Curve A : Curve B : Curve C : Curve D : Pressure drop of heating circuit with control valve (4-pipe system). Pressure drop of heating circuit without control valve (4-pipe system). Pressure drop of cooling circuit with control valve (2 and 4-pipe systems). Pressure drop of cooling circuit without control valve (2 and 4-pipe systems). K : Glycol factor Twm ( C) / % Glycol 10 20 3 1.135 1.234 1.385 1.53 1.85 5 1.13 1.23 1.38 1.51 1.77 10 1.12 1.22 1.37 1.47 1.66 15 1.11 1.19 1.36 1.46 1.64 20 1.1 1.18 1.35 1.44 1.59 25 1.09 1.17 1.33 1.43 1.57 1.08 1.16 1.31 1.42 1.56 35 1.07 1.15 1.29 1.41 1.54 1.06 1.14 1.28 1.4 1.52 45 1.05 1.13 1.25 1.37 1.49 1.04 1.12 1.22 1.34 1.47 55 0.99 1.1 1.2 1.31 1.44 60 0.94 1.09 1.19 1.28 1.42 Twm : Average temperature of the mixture. Pwo : Pure water pressure drop. Pw : Brine water pressure drop. Pw : K x Pwo. Tse ( C) / % Glycol 10 20-25 Yes -20 Yes Yes -15 Yes Yes -10 Yes Yes Yes -5 Yes Yes Yes Yes 0 Yes Yes Yes Yes Yes 5 Yes Yes Yes Yes Yes Tse : Outdoor dry bulb temperature.

8 KOG LN 9 / KOG LN 12 / KOG LN 18 Water Pressure Drops (continued) Size 12 LN - 2-rows - 3 circuits C A B kpa D 20 10 0 100 200 0 0 0 600 700 l/h Curve A : Curve B : Curve C : Curve D : Pressure drop of heating circuit with control valve (4-pipe system). Pressure drop of heating circuit without control valve (4-pipe system). Pressure drop of cooling circuit with control valve (2 and 4-pipe systems). Pressure drop of cooling circuit without control valve (2 and 4-pipe systems).

KOG LN 9 / KOG LN 12 / KOG LN 18 9 Water Pressure Drops (continued) Size 18 LN - 3-rows - 4 circuits 70 60 A B C kpa 20 D 10 0 100 200 0 0 0 600 700 800 900 1000 l/h Curve A : Curve B : Curve C : Curve D : Pressure drop of heating circuit with control valve (4-pipe system). Pressure drop of heating circuit without control valve (4-pipe system). Pressure drop of cooling circuit with control valve (2 and 4-pipe systems). Pressure drop of cooling circuit without control valve (2 and 4-pipe systems).

10 KOG LN 9 / KOG LN 12 / KOG LN 18 Operating Limits Use of chilled water Lower limits Indoor temperature C Thi 13 Tsi 17 Water temperature C Twe 5 Higher limits Indoor temperature C Thi 22 Tsi 32 Water temperature C Twe 18 Thi : Indoor wet bulb temperature. Tsi : Indoor dry bulb temperature. Twe : Entering water temperature. Use of hot water Thi 22 Maximum indoor temperature C Tsi 32 Maximum entering water temperature C Twe 70 (1) (2) Thi : Indoor wet bulb temperature. Tsi : Indoor dry bulb temperature. Twe : Entering water temperature for 2 or 4-pipe systems. (1) : For reversible 2-pipe system with extra electric heater energized, maximum Twe is 35 C. (2) : For applications with water temperature higher than 70 C, consult factory. Water connections Models 9 LN 12 LN 18 LN Contents l 1.3 1.3 2 Maximum operating pressure bar 15 15 15 Test pressure bar 24 24 24 Couplings (2-pipe system) Ø 1/2" gas male 1/2" gas male 3/4" gas male mm 15-21 male 15-21 male 20-27 male Couplings (4-pipe system) Ø 1/2" gas male 1/2" gas male mm 15-21 male 15-21 male 1/2" gas male (heating) 3/4" gas male (cooling) 15-21 male (heating) 20-27 male (cooling) Fresh air intake Fresh air flow should not exceed 12 % of nominal air flow (see table below). An antifreeze thermostat, switching off the external fan at +5 C, must be used on fresh air intake during winter period. A filter, fan and insulated air duct are to be provided on site. Models 9 LN 12 LN 18 LN Nominal air flow in high speed m 3 /h 720 720 8 Maximum fresh air flow m 3 /h 85 85 100

KOG LN 9 / KOG LN 12 / KOG LN 18 11 Dimensional Data (mm) 2-pipe Cassettes 620 571 327 270 276 (IRYS) 7 8 9 B A 12 11 Ø 200 10 Ø 100 6 287 293 (IRYS) 571 510 3 4 625 595 (IRYS) 34 (IRYS) C 5 2 1 legend 625 595 (IRYS) 1 False ceiling 7 Condensate drain (Ø15) 2 T-shaped rod (false ceiling) 8 3 Coil 9 4 Fan 10 Fresh air intake Water leaving gas male coupling (refer to table "water connections") Water entering gas male coupling (refer to table "water connections") Sizes 9 LN 2-pipe 12 LN 2-pipe 18 LN 2-pipe A 39 39 B 119 119 1 C 126.5 126.5 106.5 5 Suction grille 11 Opening for air diffusion through a duct into the adjacent room (pre-punched) 6 Electrical connection 12 Air vent 4-pipe Cassettes 620 571 327 270 276 (IRYS) 7 8 9 B1 A 12 B2 E 11 Ø 200 10 Ø 100 6 287 293 (IRYS) 571 510 3 4 625 595 (IRYS) 34 (IRYS) C D 5 2 1 legend 1 False ceiling 7 Condensate drain (Ø15) 2 T-shaped rod (false ceiling) 8 3 Coil 9 4 Fan 10 Fresh air intake 5 Suction grille 11 Water leaving gas male coupling (refer to table "water connections") Water entering gas male coupling (refer to table "water connections") Opening for air diffusion through a duct into the adjacent room (pre-punched) 6 Electrical connection 12 Chilled water air vent Sizes 9 LN 4-pipe 625 595 (IRYS) 12 LN 4-pipe 18 LN 4-pipe A 39 39 39 B1 119 119 1 B2 119 119 132 C 76.5 76.5 85.5 D E 39 39

12 KOG LN 9 / KOG LN 12 / KOG LN 18 Notes

Systemair AC SAS route de Verneuil, 27570 Tillières-sur- Avre Tél. 02 32 60 61 00 Fax 02 32 32 55 13 www.systemair.fr Systemair EDM KOG1-S-3GB/02.15 - Supersedes EDM KOG1-S-1GB/11.14 As part of our ongoing product improvement programme, our products are subject to change without prior notice. Non contractual photos. february 2015