KEPCO SINGLE OUTPUT, 1U SIZE, 150 WATT HOT SWAP PLUG-IN POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, HSF-1UR 150W SERIES

Similar documents
AC/DC Power Modules C B. TML Series, 20 & 40 Watt. Features. 20 Watt Models

EPL225 Series. 225 Watts. AC-DC Power Supplies. Models & Ratings. Summary

TEP 200WIR Series, Watt

Antec TruePower User's Manual

CPCI-3U-AC-300W-R. Rugged 300W AC Input 3U CompactPCI Power Supply. Electrical Specification for: Telkoor Part Number:

650W Single Output Power Supply 15V 24V. 27V 48V Rated Current. 0 ~ 100A 0 ~ 50A 0 ~ 40A 0 ~ 27A 0 ~ 24A 0 ~ 13.6A Rated Power

1000W Single Output Power Supply 15V 24V. Protection type: Total Power limit, Latch-style (Recovery after reset AC power ON or inhibit)

650W Single Output Power Supply

Power Supplies 3. SDN-P DIN Rail Series

Series AMLDL-Z Up to 1000mA LED Driver

AC-DC Single Output Power Module

ST Series POWER SUPPLIES USER INSTRUCTIONS

O WA-120U series IP W Single Output Switching Power Supply. Features. Aplications

Single Output Switching Power Supply

NFF Series. CoolX600 NFF Series Cool. Patented Resonant Technology. NFF Series; No Fan Featured

D1U54P-W HxxC Series 54mm 1U Front End AC-DC Power Supply Converter PRODUCT OVERVIEW FEATURES

DCS Series 1 kw, 1.2 kw, & 3 kw

Series OMEGA WATTS POWER SUPPLY AC/DC SINGLE OR MULTIPLE OUTPUT. Flexible modular design. Programmable outputs** Power factor correction***

HFE1600 Series 1600W 1U Hot Swap Front End Power Supplies

Product Family of Capacitor Chargers PS-17XX for 1500J/Sec in the range 500Vac to 1,000Vac PS-22XX for 2200J/Sec in the range 500Vac to 1,000Vac

I STAR COMPUTER CO., LTD

UMEC International Corporation

Series AMEPR30-AZ up to 2.5A AC-DC / DC-DC LED Driver / Converter

DC-DC Converter Module

Maximum Input Current Vin=18V, 100% Load A

RoHS APPROVAL SHEET. ituner 12V/6.6A SERIES NO. (E17) EA10953A. ( ) Edac Power Electronics (Suzhou) Co., Ltd. 59 No.59, Chang Sheng Road, Sheng Pu,

28 Volt Input - 40 Watt

Silvertel. Ag Features. 2 Description. Power-over-Ethernet Plus Module. IEEE802.3at and IEEE802.3af compliant. Maximum 30W output power

Chrome DIN Rail Power Supply 24V 30W 1 Phase (Class II & NEC Class 2) / DRC-24V30W1AZ

Chrome DIN Rail Power Supply 24V 91.2W 1 Phase (Class II & NEC Class 2) / DRC-24V100W1AZ

Watts SHP Series

User manual Rev. 1.2 (17/04/2015)

Bulletin 150 Smart Motor Controllers SMC-3 Smart Motor Controller

MODEL PBA300F-3R3 PBA300F-5 PBA300F-7R5 PBA300F-12 PBA300F-15 PBA300F-24 PBA300F-36 PBA300F-48 MAX OUTPUT WATTAGE[W]

Looking For A High Power, Low Profile Power Supply? KEPCO. Has More Than One Way To Help Make Your Decision Easier! AN ISO 9001 COMPANY

CliQ DIN Rail Power Supply 24V 120W 1 Phase / DRP024V120W1AA

Safety technique. Emergency stop module BO 5988 safemaster

MICROSENS. Central 48 V DC Power Supplies for PoE-Components. Description. Features

GWS250 Series Instruction Manual

Lockout Hysteresis Voltage VDC Maximum Input Current Vin=18V, 100% Load A Vin=24V ma

FPAB20BH60B PFC SPM 3 Series for Single-Phase Boost PFC

RM4TG20 three-phase network control relay RM4-T - range V

Thyristor-controlled power supplies and battery chargers

SST-ST70F-ESB SST-ST60F-ESB

MCR1900 Media Converter 19-Slot Chassis

Datasheet. Arrant-Light Oy. 120W DR Series

DC/DC Converter 9 to 18Vdc and 18 to 36Vdc and 36 to 75Vdc input, 20 Watt Output Power; 3.3 to 15Vdc Single Output and ±12Vdc to ±15Vdc Dual Output

RM17TE V AC. Main. Product or component type. Product specific application. Relay monitored parameters 250 V DC 5 A DC

Chrome DIN Rail Power Supply 12V 54W 1 Phase (Class II & NEC Class 2) / DRC-12V60W1AG

Whale 3. User Manual and Installation Guide. DC Servo drive. Contents. 1. Safety, policy and warranty Safety notes Policy Warranty.

Application Note TMA Series

Power Supply Unit, Primary Switched, Narrow Design MINI-PS-12-24DC/24DC/1

38 Series - Relay interface modules A

OmniVS Series 1500VA Line-Interactive Tower 120V UPS with USB port

Isolated AC Sine Wave Input 3B42 / 3B43 / 3B44 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

AS A Low Dropout Voltage Regulator Adjustable & Fixed Output, Fast Response

CAUTION! THE 7I29 USES VOLTAGE AND POWER LEVELS THAT REPRESENT A HAZARD TO LIFE AND LIMB.

Process modules Digital input PMI for 24 V DC inputs for 120 V AC inputs

38 Series - Relay interface modules A

Chassis, Power Supply, and Element Management

Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous

PD30ETB20xxIS. Photoelectrics, Background Suppression reflective with IR light. Main features. Description

Industrial Power Supplies

3000W Single Output Power Supply

Cisco Nexus 7000 Series Power Supply Modules

ABB 1 NEW. Three-phase monitoring relay for grid feeding CM-UFS.1. Data sheet. Features. Approvals. Marks. Order data. Order data - Accessories

FL ballasts Electronic dimming. PCA T5 BASIC lp Y II, W BASIC T5

PWM-90 series IP67 TRC ELECTRONICS, INC Mean Well PWM-90 Series

PB-600 series. 600W Single Output Battery Charger SPECIFICATION MODEL PB PB PB V 28.8V 57.6V 13.8V

User s Manual Before using the inverter, you need to read and save the safety instructions.

LDS WLED Matrix Driver with Boost Converter FEATURES APPLICATION DESCRIPTION TYPICAL APPLICATION CIRCUIT

RM35UA13MW. range V. Main. Product or component type. Relay monitored parameters

55K SERIES 28 Vin DC/DC Converter 75 Watt Single & Triple Outputs

3000W Single Output Power Supply

Instruction Manual PFE300S 500S SERIES. TDK-Lambda PFE300S 500S Series INSTRUCTION MANUAL

E-STOP relays, safety gate monitors

Industrial-Grade UPS System Heavy-duty power protection for harsh industrial environments

LM138 LM338 5-Amp Adjustable Regulators

Top Microsystems Proprietary Specification P/N: W090015HK-XP RB V.A0 SPECIFICATION

PS 2500 FA U LT TOLERANT POWER SUPPLY

38 SERIES. Relay interface modules A. EMR Electromechanical Relays. Common features. SSR Solid State Relays. 6.

Technical Specification for 5VDC/2A +12VDC/2A Adapter

3. Design Requirements

APC Matrix-UPS 5kVA 208V/240V In 120/208/240V Out

STRATO LED Drivers 70W, Single output

Clear Glass Sensor. Ordering Information E3S-CR67/62. Optimum Sensor for Detecting Transparent Glass and Plastic Bottles

AP/UP, AP/MIL Series. Magnetic Circuit Protectors

Power Supplies 3. SDN-C Compact DIN Rail Series

R4D0-FB-IA* FieldBarrier. Features. Assembly. Function. Connection IN + - S OUT Spur 2. Spur 1. Zone 1. Zone 0

Outdoor 33.6W Dual Port Passive Power-over-Ethernet Midspan For External Security Cameras and Wireless Access Points

PowerAmp Design. PowerAmp Design PAD135 COMPACT HIGH VOLATGE OP AMP

TAA-Compliant SmartPro 120V 1kVA.8kW Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

CompactLogix Power Supplies Specifications

SmartPro 120V 1kVA 800W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack, USB, DB9 Serial

DLP-PU/E Instruction Manual

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, SNMP, Webcard, 1U Rack-Mount, USB, DB9 Serial

Telephone- and leased line modem for industrial applications TD-36

SmartPro 120V 750VA 600W Line-Interactive Sine Wave UPS, 1U Rackmount, SNMPWEBCARD Option, USB, DB9 Serial

Specifications H8CA-S H8CA-S RATINGS. Approved by the following standards CHARACTERISTICS

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

Transcription:

INSTRUCTION MANUAL KEPCO An ISO 9001 Company. HSF-1UR 150W SERIES KEPCO SINGLE OUTPUT, 1U SIZE, 150 WATT HOT SWAP PLUG-IN POWER SUPPLIES I INTRODUCTION The Kepco HSF-1UR 150 Watt Series hot swappable, high frequency switching, plug-in power supplies with built-in power factor correction (PFC) employ forward conversion and are designed to operate in a fault tolerant power system with either a-c or d-c input. A thermistor soft-start circuit limits start-up surge; an input fuse (5A, 250V) protects against shorts. Built-in OR-ing diodes (all models) and a forced current share circuit (all models except 3.3V) allow configuration of all models for hot-swap and parallel-redundant N+1 operation. The heart of the HSF-1UR Series is a Kepco RTW power supply allowing them to weigh less and have improved efficiency (input current) specifications over the older HSF-1U Series. There are three options available: C, X and Y. Features for all models are the same except as follows: C option (-1URC) models include a current sensing resistor, allowing external current monitoring within ±10% (contact Kepco if greater accuracy required). X option (-1URX) models have remote control, the ability to turn the unit on and off from a remote location. Y option models (-1URY) include both current monitoring and remote on-off capabilities. These power supplies are designed to be used with Kepco s Series RA 19-1U rack adapters. The RA 19-1U rack adapter accepts up to four 50-, 100- or 150-Watt units (see Figure 1). All input/output connections are through a 24-pin connector that plugs in to the rack adapter. All external connections are made through the rack adapter (refer to the RA 19-1U manual which is available for free download at: www.kepcopower.com/support/opmanls.htm#ra19-1u Seven models may be selected for outputs of 3.3, 5, 12, 15, 24, 28 or 48V (see Table 1). When the input is cut off, the output is maintained for 20 milliseconds minimum. If the power supply shuts down due to an output overvoltage condition, it is then necessary to wait 60 seconds minimum before turning the unit on again. EMI filtering is designed to meet FCC Class B rating and VDE 0871 Class B rating. Table 1 contains specifications that vary for each model of the HSF-1UR 150 Watt Series. Common specifications are listed on page 4. TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, HSF-1UR 150W SERIES MODEL HSF 3.3-30-1UR HSF 5-30-1UR HSF 12-12-1UR HSF 15-10-1UR HSF 24-6.3-1UR HSF 28-5.3-1UR HSF 48-3.1-1UR OUTPUT VOLTS, d-c (NOMINAL) 3.3V 5V 12V 15V 24V 28V 48V ADJUSTMENT RANGE 2.8-3.4V 4.3-5.3V 9.8-13.0V 12.3-16.5V 19.2-26.0V 23.0-30.2V 40.0-52.2 OVERVOLTAGE SETTING (1) (2) 3.75-5 V 5.6-6.7V 13.3-15.5V 16.8-18.8V 26.5-30.3V 31.5-34.8V 54.5-59.8V OUTPUT CURRENT, NOMINAL 30A 30A 12.5A 10A 6.3A (10A Peak (7) ) 5.3A 3.1A OVERCURRENT SETTING (2) (3) 38.5-45.5A 33.0-39.0A 13.7-16.3A 11.0-13.0A 10.5-13.5A 5.94-7.02A 3.52-4.16A OUTPUT POWER, MAX (4) 100W 150W 150W 150W 151.2W 151.2W 153.6W RIPPLE AND NOISE (5) switching (typ.) 80 80 100 100 150 150 200 (mv p-p) spike noise 0-40 C, 10-100% LOAD (d-c 50MHz) 120 120 150 150 200 200 300 SENSE RESISTOR VALUE (milliohms) (6) 2.5 2.5 10 10 20 20 30 (1) Overtemperature or overvoltage shuts down the output. Recover by recycling a-c input (30 second delay required before resetting). (2) 25 C, Nominal. Input. (3) Hiccup mode operation. After the cause of overcurrent is removed, output voltage recovers automatically. (4) See power rating curve, Figure 4. Exceeding maximum power rating may result in oscillation or a drop in output current or voltage. (5) Ripple and noise will be approximately 1.5 times higher in the operating temperature range -10 to 0 C. (6) Sense resistor included on C and Y Models only (see Current Monitor on page 2 for details). (7) Peak current and thermal protection applicable to 24V model only. See Figure 1 for peak power requirements. 2013, KEPCO, INC 1 Data subject to change without notice 228-1621 REV 6

II FEATURES FRONT PANEL ACCESS. The front panel provides a power ON/OFF switch controlling input power and a VDC ON light which indicates when the unit is operating. NOTE: The ON/OFF switch must be set to OFF before removing unit from rack adapter. The front panel MAS- TER ON LED lights when 1) the unit operates independently, or 2) the unit is used in parallel redundant configurations while a) the output is less than 10% of nominal or b) the output is within 10% to 100% of nominal and the unit is functioning as a master. In parallel redundant configurations, the module with the highest voltage functions as the master. The other units are slaves, and track the output voltage of the master. Refer to Current Share Bus (CSB) on page 3 for details. (The MASTER ON LED is not used on 3.3V model; it is always off.) The front panel Vadj trimmer provides adjustment of the output voltage within the limits specified in Table 1; test points connected to the +S and S lines are available at the front panel for measuring the output. BUILT-IN OR-ING DIODES. OR-ing diodes allow configuration of all models for hot-swap and parallelredundant N+1 operation where current distribution is not equal and the idle unit takes over in the event of failure. 3043527 t T I 1 I 2 D=(t/T) 24V Model can supply Peak current listed in Table 1 if the four conditions listed below are met. This model includes thermal protection, voltage shutdown type. Restart by removing a-c input; after sufficient cooling, reapply a-c input (wait at least 30 seconds). 1. Time: t 10 Seconds 2. I 1 Peak Current (Amperes) 3. Effective Current: 2 2 DI 1 + ( I D) I 2 Rated current (Amperes) 4. Effective Power P Maximum Power (Watts) (output RMS current x output voltage) FIGURE 1. PEAK CURRENT REQUIREMENTS PS1 PS2 PS3 PS4 3042496 FIGURE 2. HSF-1UR 150 WATT POWER SUPPLIES (4) INSTALLED IN RA 19-1U RACK ADAPTER FORCED CURRENT SHARE CIRCUIT. (Not available on 3.3V model). When units are configured for N+1 parallel redundant operation, it is desirable (but not required) for current to be divided equally among the paralleled supplies. When the CSB (forced Current Share Bus) lines of paralleled HSF-1UR units are connected together, the load current is forced to divide equally between all paralleled units; units operate at less than maximum, reducing stress and increasing reliability of the system. If one unit fails, the remaining units will continue to supply the load, and the load current will be divided equally among the remaining operating units. The failed unit is automatically isolated from the circuit by a built-in isolation diode. Refer to Current Share Bus (CSB) on page 3 for details. REMOTE ON-OFF. Remote on/off control (X and Y models only) is via ±RC assigned to pins of the RA 19-1U I/O connector: off = no voltage, short circuit, or 0 to 0.8V, on = 4.5 to 12.5V (or 12.5 to 24.5V via 1.5K Ohms). To reverse on-off polarity contact Kepco. There is no isolation between ±RC, d-c output and alarm circuit. Refer to the RA 19-1U Manual for details. NOTE: POWER switch must be ON for remote control to be active. CURRENT MONITOR. Current monitor (C and Y models only) is via ±IMON assigned to pins of the RA 19- (X)B I/O connector. Monitored Output Current (Amps) = Voltage drop across R EQ (mvolts) / R EQ (mohms) where R EQ is the sum of R S (see Table 1) + trace resistance to point where current monitor is connected, approximately 4mOhms. The voltage drop across R EQ is measured across ± IMON pins (requires millivoltmeter, range 0 to 250mV). Accuracy is ±10%; contact Kepco if greater accuracy is required. There is no isolation between ±IMON, alarm circuit and d-c output. Refer to the applicable RA 19-1U Manual for details. 2 228-1621 REV 6 083013

ALARM CIRCUIT. The HSF-1UR includes an isolated internal relay offering normally closed and normally open contacts referenced to an isolated common. These contacts may be used to configure close on failure or open on failure alarm circuits. (Refer to the RA 19-1U Manual for alarm configurations for multiple HSF-1UR power supplies.) KEYING. Keying of the HSF-1UR is established at the factory (see Figure 3). The output voltage determines which key pins are installed. When the proper holes in the rack adapter are blocked by keying screws installed by the user, only a power supply of the correct voltage can be inserted in the rack adapter slot. (Refer to the RA 19-1U Manual for rack adapter keying instructions.) FIGURE 3. REAR CONNECTOR PIN ASSIGNMENTS CONNECTIONS: The 24-pin I/O connector (Figure 2) mates with the corresponding connector in the RA 19-1U Rack Adapter. All external connections are made at the rack adapter (see Rack Adapter Manual). (+) SENSE, ( ) SENSE: These lines are provided to compensate for voltage drops in the load connecting wires. The Sense lines must be connected to their respective (+) and ( ) output terminals, either at the load or at the rack adapter (see Rack Adapter Manual). The connection ensures the most accurate error tracking. NOTE: The Sense lines must be connected for the HSF-1UR Power supply to work properly! Compensation per lead = (min. overvoltage - max.adjustment range)/2); refer to Table 1. Compensation for 3.3V Model is 0.1V per lead. Higher compensation values are possible if output voltage is decreased below the maximum adjustment range shown in Table 1. Load wire length should not be more than 16.4ft. (5m). Transient recovery specs may not be met when remote sensing is used. To prevent oscillations and premature tripping of overvoltage protection, install one electrolytic (not tantalum) capacitor (470mF min) between +S and +V and one between ±S terminals. OUTPUT (+), OUTPUT ( ): HSF-1UR power supply d-c output. INPUT POWER: Line (either a-c or d-c source power), Neutral and Ground (chassis) CURRENT SHARE BUS (CSB): (Not available on 3.3V models.) Connecting the CSB lines of HSF-1UR power supplies operating in a parallel configuration causes output current to be shared equally. (See Rack Adapter Manual for additional information on parallel configurations.). For current sharing to work properly the outputs of all paralleled units must be within 250 mv (max) of each other and each unit must be operating at between 10% to 100% of rated output. If current to the load goes below 10% for each unit in current share mode, all MASTER ON lights may go on (see load effect specifications); this indicates that forced current share is no longer working, units are simply in current share mode. (If forced current sharing at less than 10% nominal current per supply is needed, contact Kepco application engineering.) Remote sensing is recommended. For master/slave operation to work properly each unit should be adjusted to 40 mv (optimum) less than the next paralleled unit (unit 1 is adjusted to VOUT, unit 2 to VOUT 40mV, and unit 3 to VOUT 80mV, etc. If the master fails, unit 2 will become the new master). The 40 mv difference can be reduced to a minimum of 25 mv as needed to parallel many units and still keep all units within 250 mv of each other. Adjust the outputs using Vadj trimmer on front panel. Optimum difference among output voltages of paralleled units: 40mV Maximum difference among output voltages of paralleled units: 250 mv Minimum difference among output voltages of paralleled units: 25 mv ALARM: The Alarm NC (normally closed) - Open on Failure and Alarm NO (normally open) - Close on Failure lines are relay contacts referenced to Alarm Common. If the unit fails, the path between Alarm NC - Open on Failure and Alarm Common opens, the path between Alarm NO - Close on Fail and Alarm Common is a short circuit. Figure 4 illustrates typical Close on Fail and Open on Fail circuits to give a failure indication if any one of a number of power supplies fail; refer to RA 19-1U manual for complete information regarding other configurations. 083013 228-1621 REV 6 3

Units are shipped so that the alarm will trip and shutdown will occur upon overvoltage, open sense line and fan failure (fan failure shutdown can be disabled, see Cooling: on page 5 and Figure 7). The alarm will also trip upon undervoltage, however shutdown may not occur, depending on the load. After shutdown occurs, a 60 second delay (minimum) is required before turning the unit on again. FIGURE 4. TYPICAL ALARM CIRCUIT DIAGRAMS Forced shutdown upon fan failure can be disabled by installing a jumper, Kepco P/N 172-0382 (Digikey P/N A26231-N) as shown in Figure 7. This allows the unit to continue to operate with the fan inoperative (see Figure 5 for safe operating conditions); the alarm signals noted above will report an alarm condition, and the VDC ON indicator will either light red (fan supply voltage missing) or flicker between red and green (mechanical failure). If the jumper is installed, the user is responsible for either reducing the load to within the specifications given in Figure 4, or shutting down the unit using the alarm signals provided. III SPECIFICATIONS The following specifications apply to HSF-1UR 150 Watt Series models (also refer to Table 1). Other models are also available; consult your Kepco representative for their specifications. INPUT: Voltage: 100-120V a-c, 200-240V a-c nominal; Range 90-264V a-c; 130-370V d-c. (polarity insensitive; consult factory) Frequency: Nominal 50-60 Hz; Range 47-440Hz (from 66 to 440Hz leakage current exceeds UL/ VDE safety spec. limit). Current (nominal output at 100% load): @100-120V a-c rms: 1.9A a-c rms max. 3.3V model: 1.6A rms max.; 24V Model: 2.7A rms typ. @100 Va-c input, peak output) @200-240V a-c rms: 1.0A a-c rms max. 3.3V model: 0.85A rms max.; 24V Model: 1.1A rms typ. @240 Va-c input, peak output) Initial Turn-on Surge: (cold start 25 C, first surge only, not including the current flow into the EMI filter): @100V a-c rms, 14A typ., @200V a-c rms, 28A typ. Switching Frequency: 135KHz typical, PFC boost converter: 80KHz typical, nominal load STABILIZATION: Source Effect (Range 85 to 132Va-c or 170-265 Va-c): 0.1% typ., 0.2% max. Load Effect (10% - 100% of rated output current): 0.2% typ., 0.4% max. Temperature Effect (Range -10 to 71 C): 0.5% typ., 1.0% max. Combined Effect (source, load, temperature): 0.9% typ., 1.8% max. Time Effect (drift): (1/2 to 8 hr. at 25 C) 0.2% typ., 0.5% max. RECOVERY CHARACTERISTICS: A step load change from 50% to 100% produces less than +4% output excursion. Recovery occurs to within +1% of the original setting in <2 ms (load change t r or t f equal to or greater than 50µsec). START-UP TIME: 220mS. typ., 300mS max. @100V a-c; 120mS typ., 200mS max. @240V a-c (between 0 and 40 C). ACCEPTABLE LOAD CAPACITANCE: (Start-up time is affected.) 3.3V-28V models: 100,000uF max; 48V model: 50,000uF max. HOLDUP TIME: @100V a-c All except 3.3V model: 35 ms. typ. 3.3V Model: 50mS @240V a-c. All except 3.3V model: 40mS. typ. 3.3V Model: 50mS typ. Options C, X, Y: 55mS typ. 4 228-1621 REV 6 083013

DIELECTRIC STRENGTH: (at 15 to 35 C ambient, 10 to 85% relative humidity): Between input and output: 3KV a-c for one minute, cutout current 10ma. Between input and ground: 2KV a-c for one minute, cutout current 10ma. Between output and ground: 500V a-c for one minute, cutout current 20ma. INSULATION RESISTANCE: Between input and ground, output and ground, input and output, ±RC terminals and input, ±RC terminals and output: 100 Megohms min. (500V d-c). LEAKAGE CURRENT: 0.29mA typ, 0.45mA max at 100V a-c, 60 Hz (operating in conformance with Den-An). 0.40mA typ, 0.65mA max at 240V d-c and 60 Hz (operating in conformance with IEC 950 and UL1950). SAFETY: Designed to meet EN 60950:2001 Assistance for DEN-AN. U.S. UL 60950 First Edition.; Canada: CSA- 22.2 No.60950-1. Units are CE marked per the Low Voltage Directive (LVD), EN60950 73/23/EEC AND 93/68/ EEC. [The standards do not apply with DC input operation.] HUMIDITY: 10% to 95% (wet bulb temp. <35 o C noncondensing). FUSE: Quick acting 5.0A, 250V; (5.2 x 20mm), (Littelfuse P/N 215005PF, Kepco P/N 541-0134). DIMENSIONS: See Figure 7. WEIGHT: 2.2 lbs, 1Kg. WARRANTY: 5 years. NOTE: Safety agency approvals apply only to operation up to 40 C. COOLING: All models use forced convection, ball-bearing fans, life expectancy 50,000+ hours. Natural convection can be used if the load does not exceed 60% of max. (see Figure 4). Simply disconnect the fan and install jumper J1 (see Figure 5); the alarm signals described above are disabled and VDC ON lights red; overvoltage and open sense line conditions still force unit shutdown. Contact Kepco s Application Engineering for full-featured natural convection-cooled units. EMI: Designed to meet FCC Class B (100-120V a-c) and VDE 0871 Class B (220-240V a-c). VIBRATION: (non-operating, one hour on each one of the three axes): 5-10 Hz, 10 mm amplitude; 10-55 Hz, 2g acceleration. SHOCK: (non-operating, one-half sinusoidal pulse, three shocks to each axis): Acceleration: 20g, Duration: 11mS +5mS OPERATING TEMPERATURE: See Figure 5. FIGURE 5. % OUTPUT POWER RATING VS. AMBI- ENT TEMPERATURE STORAGE TEMPERATURE: -40 o C to +75 o C. OPERATING AND STORAGE RELATIVE 083013 228-1621 REV 6 5

IV INSTALLATION MOUNTING THE POWER SUPPLY. Refer to Figure 6 and insert HSF-1UR power supply in selected slot until power supply front panel is flush with rack adapter chassis and secure with two front panel mounting screws. CAUTION: Do not overtighten these screws: max. torque is 2 in.-lbs (0.23 N x m). CONNECTIONS. All connections are made at the rear panel of the RA 19-1U Rack Adapter (see RA 19-1U Operator Manual). Connect the load to the applicable ± DC OUTPUT terminals. AC input power is applied via two INPUT POWER terminal blocks: one supplying slots 2 and 4, the other supplying slots 1 and 3. Make sure to connect the AC input Neutral, Line and Ground wires to the respective terminals of the terminal blocks. REMOVAL. To remove a power supply, first use the POWER switch to turn off the unit. Then loosen the two mounting screws and extract the unit from the RA 19-1U Rack Adapter. CAUTION: The ON/OFF switch must be set to OFF before removing the unit from the rack adapter. V OPERATION Turn the unit on using the front panel POWER switch (see Figure 6). CAUTION: DO NOT repeatedly toggle the POWER on/off switch as this may cause unit to fault. POWER SWITCH 3043412 NOTE: MOUNTING SCREW MAX TORQUE: 2 IN.-LBS. (0.23 N x m) MOUNTING SCREW TEST POINTS VOLTAGE ADJUST TRIMMER MASTER ON LED MOUNTING SCREW VDC ON LED FIGURE 6. COMPONENT LOCATIONS When output voltage is available, the VDC ON LED is on (green). For 100W and 150W 5V through 48V models the VDC ON LED lights red to indicate a fan malfunction. The 100W 3.3V model and all 50W models use convection cooling and do not include a fan. The 3.3V models do not use forced current sharing so the MASTER ON LED is always off. The MASTER ON LED for 5V through 48V models goes on under any of the three following conditions: Independent operation. Operation in a parallel master/slave configuration to indicate which unit is the master. Operation in a parallel master/slave configuration to indicate that a slave unit is no longer within the proper specifications for paralleled units. Slave 1 should be optimally adjusted to 40mV less than master, slave 2 adjusted to 40mV less than slave 1, etc. The maximum allowable difference between paralleled units is 250mv. The minimum allowable difference between paralleled units is 25mV. If a slave exceeds these limits, the MAS- TER ON light goes on. While monitoring output voltage at the front panel test points, the Output Voltage Adjust trimmer allows adjustment of the output voltage. 6 228-1621 REV 6 083013

1.088 [27.6] 0.191 [4.9] 14.131 [358.9] 0.125 [3.2] 0.507 [12.9] 1.732 [44.0] 0.507 [12.9] 0.228 [5.8] 0.190 [4.8] 0.503 [12.8] 0.282 [7.2] 13.050 [331.5] 0.129 [3.3] 0.690 [17.5] 0.303 [7.7] 1.406 [35.7] 0.156 [4.0] 4.275 [108.6] JP1 3.755 [95.4] 0.391 [9.9] 0.250 [6.4] 1.474 [37.4] SEE DETAIL "B" 1.125 [28.6] 0.260 [6.6] 0.750 [19.1] MAX MOUNTING TORQUE: 2 IN.-LBS (0.23 N x m) 0.591 [15.0] SEE DETAIL "A" 0.250 [6.4] 0.125 [3.2] 4.295 [109.1] 0.437 [11.1] 1.108 [28.2] 0.471 [12.0] 1.732 [44.0] DETAIL "A" KEY PIN LOCATION 48 VOLTS 28 VOLTS 24 VOLTS 0.066 [1.7] 0.133 [3.4] 0.780 [19.8] 3.960 [100.6] 0.076 [1.9] 0.010 [0.3] 1.131 [28.7] 15 VOLTS 12 VOLTS 5 VOLTS 3.3 VOLTS NOTES: 1. MATERIAL: A) BACKPLATE 0.064" THK. ALUM. 5052-H32 B) PCB 0.063" THK FR-4 C) FRONT PANEL 0.090 THK. ALUM. 6061-T6 2. FINISH: FRONT PANEL -KEPCO DUAL TONE GRAY 3. MODULE IS KEYED AS SHOWN IN DETAIL 4. DIMENSIONS ARE IN INCHES, [DIMENSIONS IN BRACKETS ARE IN MILLIMETERS]. 5. TOLERANCES (UNLESS OTHERWISE SPECIFIED): 3 PLACES: ±0.005, 2 PLACES: ±0.01, FRACTIONS: ±1/64" 6. TO DISABLE FORCED SHUTDOWN UPON FAN FAILURE, INSERT JUMPER (P/N 172-0382) AS SHOWN IN DETAIL "B." 7. FOR CONVECTION COOLING, DISCONNECT FAN AND INSERT JUMPER (P/N 172-0382) AS SHOWN IN DETAIL "B." FAN CONNECTOR DETAIL "B" JP1 INSERT JUMPER J1 3010294 FIGURE 7. HSF-1UR 150W POWER SUPPLY OUTLINE DRAWING 083013 228-1621 REV 6 7