POWDER DIFFRACTOMETRY ACCESSORIES YOUR PARTNER IN X-RAY DIFFRACTION. STOE & Cie GmbH

Similar documents
Encoders for Linear Motors in the Electronics Industry

Quick Guide for Data Collection on the NIU Bruker Smart CCD

BB-18 Black Body High Vacuum System Technical Description

3D SCANNERTM. 3D Scanning Comes Full Circle. s u n. Your Most Valuable QA and Dosimetry Tools A / B / C. The 3D SCANNER Advantage

X-ray thin-film measurement techniques

Powder diffraction and synchrotron radiation

Automatisierte, hochpräzise Optikmontage Lösungen für die Industrie

Fast Z-stacking 3D Microscopy Extended Depth of Field Autofocus Z Depth Measurement 3D Surface Analysis

Introduction to X-Ray Powder Diffraction Data Analysis

CHARACTERIZATION OF POLYMERS BY TMA. W.J. Sichina, National Marketing Manager

Specifying Plasma Deposited Hard Coated Optical Thin Film Filters. Alluxa Engineering Staff

Experiment 5. Lasers and laser mode structure

Rigaku XRD-System Instruction Manual v4/19/03. The Krishnan Group/Wilcox 132, University of Washington

XFA 600 Thermal Diffusivity Thermal Conductivity

COMPARISON OF TEXTURE IN COPPER AND ALUMINUM THIN FILMS DETERMINED BY XRD AND EBSD *

RL HW / RL HW+ / RL HGW / RL HV / RL HVPW/RL HVPW-G

Table of content. L81/RITA high speed Thermo Balance. Quattro Dilatometer. L75/1250/B/S Macro Dilatometer. New air cooled furnace program

P R E A M B L E. Facilitated workshop problems for class discussion (1.5 hours)

3D Printed Injection Molding Tool ("PIMT") Guide. Objet Ltd.

HEAVY DUTY SEVERING AND BEVELLING MACHINE TNO FAB-SERIES


Thermodynamics /15 Stirling engine. Applied Thermodynamics. What you need:

HFM Heat Flow Meter Thermal Conductivity Analyzer

TRIMMING UNIT/DIAMOND MACHINE TST.13

PIPELINE INSPECTION UTILIZING ULTRASOUND TECHNOLOGY: ON THE ISSUE OF RESOLUTION By, M. Beller, NDT Systems & Services AG, Stutensee, Germany

Thermal diffusivity and conductivity - an introduction to theory and practice

Tube Control Measurement, Sorting Modular System for Glass Tube

BARREL ALIGNMENT- A CRITICAL FACTOR IN REDUCING EXTRUDER WEAR

Portable digital microprocessor thermometers with interchangeable probes

Hygro-Thermometer + InfraRed Thermometer Model RH101

Items Supplied. Frequency. Designation Description / Delivery Unit Order Number

Melting Point. Electrothermal PRODUCT SPECIFICATIONS OPERATION

Sample preparation for X-ray fluorescence analysis

Silicon Pyranometer Smart Sensor (Part # S-LIB-M003)

UV-Vis spectrophotometers

Vacuum drying oven for non-flammable solvents

Precision Vise Combinations

haze-gard i The objective standard for a clear view Global communication Reliable and Precise

Material test chamber with mechanical convection

Thermal Values. Melting-, Dropping- and Softening Point Simple, fast and reliable

Zero Width Glass Cutting with CO 2 Laser

Measurement of Enhanced Specular Reflector (ESR) Films Using a LAMBDA 1050 UV/Vis/NIR Spectrometer and URA Accessory

Polarization of Light

Introduction to Powder X-Ray Diffraction History Basic Principles

73 Series Spectrophotometers

Chapter 7: Basics of X-ray Diffraction

Incubator with mechanical convection

Increased flexibility and greater cost-efficiency in profile extrusion 32D twin-screw extruders profile series. Engineering Value

Veraview IC5 HD High definition, digital imaging excellence. Thinking ahead. Focused on life.

E. K. A. ADVANCED PHYSICS LABORATORY PHYSICS 3081, 4051 NUCLEAR MAGNETIC RESONANCE

Pipe Cutting and Beveling Clamshells

Focus on increased productivity

Sample Storage Product Range

Injection molding equipment

HOT BAR REFLOW SOLDERING FUNDAMENTALS. A high quality Selective Soldering Technology

Bar Code Label Detection. Size and Edge Detection APPLICATIONS

Bruker AXS. D2 PHASER Diffraction Solutions XRD. think forward

Highly efficient flue gas analyzer

Micro-CT for SEM Non-destructive Measurement and Volume Visualization of Specimens Internal Microstructure in SEM Micro-CT Innovation with Integrity

Precise heavy-duty cutting

Operation Manual For NDJ-8S Digital Rotary Viscometer

Characteristics of an Integrated Germanium Detector Based Gamma-Ray Spectrometer for Monitoring Systems

THE COMPOSITE DISC - A NEW JOINT FOR HIGH POWER DRIVESHAFTS

Facts About. Industrial gases for better injection molding. This article appeared in the trade journal Kunststoffe plast europe, issue 12/2004.

Thickness Gauges. convex R 15 or R 40, flat 10 mm Ø, spherical

Sound absorption and acoustic surface impedance

TechCut 4 Precision Low Speed Saw

Torque Transducers MEASURING ELECTRONIC

Analytical Testing Services Commercial Price List ManTech International Corporation January 2016

CT for the production floor: Recent developments in Hard- and Software for industrial CT Systems

Single Mode Fiber Lasers

WAVELENGTH OF LIGHT - DIFFRACTION GRATING

Mold Preventing I nterior System

Rodenstock Photo Optics

GC-xt. The most flexible GC /GC-MS liquid sample injector

The Quality Connection. High Performance Cable Solutions for the World of Semiconductors

The Quality Connection. High Performance Cable Solutions for the World of Semiconductors

ECMO AND LIFE SUPPORT SYSTEMS QUADROX PLS AND ROTAFLOW HARDWARE AND ACCESSORIES

Specials. designed. 3rd edition 2015 English. for scientists 1

Optiffuser. High-performance, high bandwidth lightweight 1D diffuser.

Melting Point Range. with BioCote antimicrobial protection

Epson 3LCD Technology A Technical Analysis and Comparison against 1-Chip DLP Technology

Lecture 20: Scanning Confocal Microscopy (SCM) Rationale for SCM. Principles and major components of SCM. Advantages and major applications of SCM.

ORGANIC SAMPLE PREPARATION

Shakers. designed. to work perfectly

Distributed Temperature Monitoring of Energy Transmission and Distribution Systems

OPTICAL MEASURING MACHINES

MaraMeter. Indicating Snap Gages

X-ray Diffraction and EBSD

Detailed Design Review. P15611: Digital Microfluidics Packaging

Three Channel Optical Incremental Encoder Modules Technical Data

SpeedLight 2D. for efficient production of printed circuit boards

International Year of Light 2015 Tech-Talks BREGENZ: Mehmet Arik Well-Being in Office Applications Light Measurement & Quality Parameters

As versatile as your requirements. 384 well. 96 well combi 48 well in situ

Corrugated Tubular Heat Exchangers

How To Design A 3D Print In Metal

Radiant Dyes Laser Accessories GmbH

Digital panoramic X-ray for practical diagnostics

Transcription:

POWDER DIFFRACTOMETRY ACCESSORIES YOUR PARTNER IN X-RAY DIFFRACTION STOE & Cie GmbH WWW.STOE.COM

POWDER DIFFRACTOMETRY TRANSMISSION/DEBYE-SCHERRER TRANSMISSION SAMPLE HOLDER Quick overview measurements as well as Rietveld quality data collection Polymer samples (fibres or foils) Very small sample amounts As very thin films of sample can be prepared on STOE s zero scattering foils, this technique is preferable for highly absorbing materials when measured in transmission mode Easy and clean preparation of samples on zero scattering foils Convenient loading of sample inserts with different inner diameters Sample displacement and thickness can be corrected by a micrometer screw Sample rotation in a high precision ball-bearing guarantees minimal reflex broadening and low noise CAPILLARY SAMPLE HOLDER Minimising preferred orientation leading to accurate intensities for structure solution and Rietveld refinement Obtaining narrow FWHM and symmetric profiles Suitable for air sensitive and hygroscopic materials in sealed capillaries Also used with low temperature attachments Glass capillaries between 0.1 and 2.0 mm diameter A precise goniometer head, aligned by video CCD control, guarantees coincidence of capillary and diffractometer axis / COMBI / COMBI

PERMANENT ALIGNED CAPILLARY SAMPLE HOLDER Qualitative and quantitative phase analysis Fast data acquisition in combination with the IP-PSD Auto-alignment due to three guide bushes Easiest capillary exchange Sample rotation for excellent statistics Height adjustment for an optimal sample position in the X-ray beam GANDOLFI SAMPLE HOLDER Accurate investigations of samples with preferred orientation Precise goniometer head 45 phi axis Permanent rotation / COMBI Capillaries between 0.1 and 1.1 mm / COMBI

POWDER DIFFRACTOMETRY REFLECTION REFLECTION SAMPLE HOLDER The reflection mode has to be applied in all cases the transmission or the capillary techniques cannot be used, e.g. for measurements of bulk materials, liquids, Langmuir-Blodgett films or thin layers. Precise height adjustment of the sample using a reference blade Zero background sample inserts with or without cavity REFLECTOMETRY SAMPLE HOLDER As misalignment of the sample strongly affects the quality of the results in reflectometry experiments, STOE s Reflectometry Sample Holder has been designed for accurate alignment for e.g.: Reflectometry experiments to determine film thickness, composition and interface roughness Standard powder diffractometry Grazing incidence experiments for phase analysis of thin films Reference blade for reproducible height adjustment Micrometer-controlled sample alignment with digital sample position display Reference blade serves as collimator in reflectometry measurements Manual tilt correction possible Sample spinning for wide-angle X-ray diffraction

MULTI-PURPOSE ANALYZER STAGE Determination of crystal axis orientation of large single crystals Alignment of the goniometer head carrying a large single crystal for grinding and cutting Automatic XRPD-analysis of round or squared sample arrays in combinatorial analysis Standard ACA goniometer head mount Motorized and PC-controlled X and Y translation +/- 10 mm with a resolution of 5 Μm Motorized and PC-controlled rotation with a resolution of 0.0072 Manual micrometer-controlled Z translation (0 50 mm) for the alignment of a crystal surface or a sample array to the reference blade

POWDER DIFFRACTOMETRY HIGH TROUGHPUT TRANSMISSION AND REFLECTION SAMPLE CHANGER The sample changers for transmission or reflec - tion can be set up on the diffractometes as pre-aligned additional units and are controlled by the software package WinX POW. The user benefits from fast sample throughput, proven reliability and high quality data sets. Each file is carrying its unique identifier accessible through the flexible WinX POW file management system. The STOE sample changers are as easy to exchange as the other STOE sample holders. TRANSMISSION SAMPLE CHANGER Capacity of up to 30 samples Easy load/unload function Controlled by STOE s Software Package WinX POW REFLECTION SAMPLE CHANGER Capacity of up to 12 samples Easy height adjustment for bulk samples with different thickness (up to 20 mm) Controlled by STOE s Software package WinX POW

CAPILLARIES SAMPLE CHANGER The sample changer for capillaries has been developed for automated measurements of up to 10 capillaries in Debye-Scherrer mode. The capillaries have only to be inserted in the guide bushes, therefore no alignment, e.g. of a goniometer head, is necessary. The position of the capillaries in the X-ray beam and their exposure time are menu-driven by STOE s control and evaluation software. A manual height adjustment to optimize the amount of sample material in the beam is, of course, included. Capacity of up to 10 capillaries Additional height adjustment for optimized sample position in the beam HIGH THROUGHPUT AND COMBINA- TORIAL ANALYSIS SAMPLE CHANGER Fast measurements even of small amounts of sample material Measurements of liquids Whole area of combinatorial and high throughput analysis Variable X, Y grid Easily exchangable inserts for up to 96 samples Height adjustment by micrometer screw Menu driven position control > STOE STADI P / COMBI No capillary alignment necessary

POWDER DIFFRACTOMETRY HIGH TEMPERATURE ATTACHMENTS STOE Furnace HIGHEST ACCURACY FOR CAPILLARIES The STOE STADI P and STADI MP is the ideal equipment for the observation and evaluation of phase transitions in non-ambient environments. Therefore STOE has developed the capillary furnace series for powder investigations at high temperatures for three different temperature ranges: The basic version from RT to 1000 C The extended T version from RT to 1500 C The furnace with low temperature option for a range from 50 to 1000 C Basic version mounted on a fixed stage with STOE s large IP-PSD, video CCD and tube housing. All STOE furnaces are delivered with a referring temperature controller in a 19 rack containing power supply, flow meter for the cooling water control and interface to the PC. All three versions provide sample spinning to avoid effects from preferred orientation. The tempera - ture programs are easy to being set-up and executed. The temperature stability in the whole range is below +/- 1 C. The STOE furnaces can be mounted on every STADI P and STADI MP diffractometer. Heating elements are available for capillaries with diameters from 0.2 to 1.0 mm. TECHNICAL SPECIFICATIONS BASIC VERSION EXTENDED VERSION LOW-TEMPERATURE VERSION Temperature range RT 1000 C RT 1500 C -50 C 1000 C Thermo couple Ni/CrNi Pt/PtRh Ni/CrNi Heating power 1000 W 1300 W 1300 W Max. heating rate 50 /min 50 /min 50 /min 2Θ range 0 90 0 90 0 90 Sample holder Capillary Capillary + Pt-/Ir-Wire Capillary STOE & Cie GmbH Hilpertstrasse 10 64295 Darmstadt Germany P +49 (0) 6151 98870 F +49 (0) 6151 988788 info@stoe.com WWW.STOE.COM