This article demonstrates how to connect to iscsi Target created by istorage Server using KernSafe WinCE iscsi Initiator on Windows Mobile device.

Similar documents
istorage Server: High-Availability iscsi SAN for Windows Server 2008 & Hyper-V Clustering

istorage Server: High Availability iscsi SAN for Windows Server 2012 Cluster

K-Backup: Network automatic backup data to free iscsi SAN

StarWind iscsi SAN Software: Tape Drives Using StarWind and Symantec Backup Exec

K-Backup: Automatic Network Backup solution

StarWind iscsi SAN Software: Using StarWind with MS Cluster on Windows Server 2008

StarWind iscsi SAN Software: Challenge-Handshake Authentication Protocol (CHAP) for Authentication of Users

StarWind iscsi SAN: Configuring Global Deduplication May 2012

StarWind iscsi SAN Software: Implementation of Enhanced Data Protection Using StarWind Continuous Data Protection

StarWind iscsi SAN Configuring HA File Server for SMB NAS

StarWind iscsi SAN: Configuring HA File Server for SMB NAS February 2012

Drobo How-To Guide. Cloud Storage Using Amazon Storage Gateway with Drobo iscsi SAN

NETFORT LANGUARDIAN INSTALLING LANGUARDIAN ON MICROSOFT HYPER V

StarWind iscsi SAN Software: Using StarWind with MS Cluster on Windows Server 2003

Drobo How-To Guide. Use a Drobo iscsi Array as a Target for Veeam Backups

How to configure Failover Clustering for Hyper-V hosts on HP ProLiant c-class server blades with All-in-One SB600c storage blade

Integrating Data Protection Manager with StorTrends itx

HP LeftHand SAN Solutions

Drobo How-To Guide. Use a Drobo iscsi Array as a Target for Veeam Backups

StarWind iscsi SAN & NAS: Configuring HA Storage for Hyper-V October 2012

Veeam Backup Enterprise Manager. Version 7.0

StarWind iscsi SAN & NAS: Configuring HA Shared Storage for Scale- Out File Servers in Windows Server 2012 January 2013

StarWind iscsi SAN Software: Using StarWind with VMware ESX Server

StarPort iscsi and ATA-over-Ethernet Initiator: Using Mirror (RAID1) disk device

VT Technology Management Utilities for Hyper-V (vtutilities)

Configuring Network Load Balancing with Cerberus FTP Server

5nine Hyper-V Commander

Drobo How-To Guide. Topics. What You Will Need. Prerequisites. Deploy Drobo B1200i with Microsoft Hyper-V Clustering

Installation Guide July 2009

StarWind iscsi SAN Software: Providing shared storage for Hyper-V's Live Migration feature on two physical servers

Table of Contents Introduction and System Requirements 9 Installing VMware Server 35

How To Set Up A Two Node Hyperv Cluster With Failover Clustering And Cluster Shared Volume (Csv) Enabled

StarWind iscsi SAN & NAS: Configuring HA File Server on Windows Server 2012 for SMB NAS January 2013

StarWind iscsi SAN Software: Installing StarWind on Windows Server 2008 R2 Server Core

StarWind iscsi SAN Software: Using an existing SAN for configuring High Availability storage with Windows Server 2003 and 2008

Installation Guide. Step-by-Step Guide for clustering Hyper-V virtual machines with Sanbolic s Kayo FS. Table of Contents

vtcommander Installing and Starting vtcommander

This guide provides all of the information necessary to connect to MoFo resources from outside of the office

StarWind Virtual SAN Installing & Configuring a SQL Server 2012 Failover Cluster

Intellicus Enterprise Reporting and BI Platform

StorSimple Appliance Quick Start Guide

SC-T35/SC-T45/SC-T46/SC-T47 ViewSonic Device Manager User Guide

Direct Storage Access Using NetApp SnapDrive. Installation & Administration Guide

Tenrox. Single Sign-On (SSO) Setup Guide. January, Tenrox. All rights reserved.

GMS. 1 Create the virtual machine 2 Configure the virtual machine 3 Configure the virtual GMS server. Quick Start Guide. Microsoft Hyper-V Hypervisor

NSi Mobile Installation Guide. Version 6.2

Installing Kaspersky Security Center 10.0 on Windows Server 2012 Failover Cluster Version Date Author Comments

Arcserve Backup for Windows

StarWind Virtual SAN Installation and Configuration of Hyper-Converged 2 Nodes with Hyper-V Cluster

System Protection for Hyper-V User Guide

Using iscsi with BackupAssist. User Guide

Configuring Windows Server Clusters

Pearl Echo Installation Checklist

Nasuni Filer Virtualization Getting Started Guide. Version 7.5 June 2016 Last modified: June 9, Nasuni Corporation All Rights Reserved

Drobo How-To Guide. What You Will Need. Configure Replication for DR Using Double-Take Availability and Drobo iscsi SAN

Multi-factor Authentication using Radius

Configuring a FlexPod for iscsi Boot

2X ApplicationServer & LoadBalancer & VirtualDesktopServer Manual

VX 9000E WiNG Express Manager INSTALLATION GUIDE

Host Installation on a Terminal Server

Implementing Microsoft SQL Server 2008 Exercise Guide. Database by Design

Installation and Deployment

Setting up Hyper-V for 2X VirtualDesktopServer Manual

Installing and Configuring a SQL Server 2014 Multi-Subnet Cluster on Windows Server 2012 R2

WhatsUp Gold v16.3 Installation and Configuration Guide

Windows Mobile 6.5 Classic Pocket Inventory Install and Setup in Windows XP

EXPRESSCLUSTER X for Windows Quick Start Guide for Microsoft SQL Server Version 1

GFI LANguard 9.0 ReportPack. Manual. By GFI Software Ltd.

Avalanche Site Edition

EMC ViPR Controller Add-in for Microsoft System Center Virtual Machine Manager

Retail Deployment Guide. Microsoft Dynamics AX 2012 Feature Pack

Keystone 600N5 SERVER and STAND-ALONE INSTALLATION INSTRUCTIONS

Storage Sync for Hyper-V. Installation Guide for Microsoft Hyper-V

QUANTIFY INSTALLATION GUIDE

Index C, D. Background Intelligent Transfer Service (BITS), 174, 191

Vess A2000 Series. NVR Storage Appliance. Windows Recovery Instructions. Version PROMISE Technology, Inc. All Rights Reserved.

Install Pocket Inventory in a Windows Server 2003 R2 Standard Environment

QUICK START GUIDE MONDOPAD/WIN

Interact for Microsoft Office

User Guide. Version 3.2. Copyright Snow Software AB. All rights reserved.

Installing Windows Server Update Services (WSUS) on Windows Server 2012 R2 Essentials

Using Device Discovery

Implementing and Managing Microsoft Server Virtualization

Virtual Owl. Guide for Windows. University Information Technology Services. Training, Outreach, Learning Technologies & Video Production

In addition to their professional experience, students who attend this training should have technical knowledge in the following areas.

Welcome to MaxMobile. Introduction. System Requirements

2. RAID Management RAID migration N5200 allows below RAID migration cases.

2X ApplicationServer & LoadBalancer Manual

Microsoft SQL Database Administrator Certification

GX-V. Quick Start Guide. Microsoft Hyper-V Hypervisor. Before You Begin SUMMARY OF TASKS. Before You Begin WORKSHEET VIRTUAL GMS SERVER

QNAP and Failover Technologies

Objectives. At the end of this chapter students should be able to:

Integrating Trend Micro OfficeScan 10 EventTracker v7.x

NETASQ ACTIVE DIRECTORY INTEGRATION

GFI LANguard 9.0 ReportPack. Manual. By GFI Software Ltd.

How To Create An Easybelle History Database On A Microsoft Powerbook (Windows)

Setting up Hyper-V for 2X VirtualDesktopServer Manual

Microsoft Virtual Labs. Windows Server 2003 R2: Efficient Storage Management

Lesson Plans Microsoft s Managing and Maintaining a Microsoft Windows Server 2003 Environment

Best Practices for Installing and Configuring the Hyper-V Role on the LSI CTS2600 Storage System for Windows 2008

Transcription:

istorage Server and WinCE iscsi Initiator For Windows CE Embeddedd and Windows Mobile Tuesday, July 5, 2011 KernSafe Technologies, Inc. www.kernsafe.com Copyright KernSafe Technologies 2006 2011. All right reserved.

Table of Contents Configuring istorage Server... 4 Creating Target... 4 Logging on to the target... 12 Adding portal... 12 Connecting to target... 14 Accessing data... 17 Logout from target... 18 Removing portal... 20 Contact... 21

KernSafe istorage Server is an advanced and powerful, full featured software only iscsi Target that fully conforms to the latest iscsi Standard 1.0 (former Draft 20). It is an IP SAN solution allowing you to quickly export existing storages such as disk images, VHD files, physical disks, partitions, CD/DVD ROMs, tapes or any other type of SCSI based devices and even a variety of popular CD/DVD images to the client machines. The software thus delivers immediate benefits, as it allows storage to be consolidated, virtualized and centrally managed. istorage Server also provides RAID 1 (mirror) feature enabling you to create two iscsi devices for mirror backup. Furthermore, istorage Server also supports a lot of features such as: VHD (Virtual Hard Disk) target, snapshots, STPI, RAID 1 and failover, these features are very important and poplar in storage industry world and make istorage Server is suitable for any size of business. After istorage Server 2.0, it supports server side mirroring, synchronous replication and failover which allows user to create a high availability iscsi SAN. KernSafe Free WinCE iscsi Initiator enables connection to a computer that is running any iscsi SAN like istorage Server from any Windows CE based devices, such as: WinCE Embedded device and Windows Mobile, in order to connect to iscsi Target storage over Wi Fi, 3G or 4G network. WinCE iscsi Initiator can be used over existing wired and wireless (Wi Fi, 3G, 4G etc.) networks to create storage area networks (SANs). That will help iscsi Initiator device to expand their virtual storage without any additional hardware requirements which is a huge benefit for home and business solutions. An embedded system is a computer system designed to do one or a few dedicated and/or specific functions often with real time computing constraints. It is embedded as part of a complete device often including hardware and mechanical parts. Embedded systems control many devices in common use today. Windows Mobile is a mobile operating system developed by Microsoft that is used in smartphones and mobile devices. It is very common and easy to use since it looks similar to desktop version of Windows operating system. This article demonstrates how to connect to iscsi Target created by istorage Server using KernSafe WinCE iscsi Initiator on Windows Mobile device.

Configuring istorage Server Creating Target Open istorage Server Management Console. Launch the istorage Server Management Consolle, press the Create button on the toolbar, the Create iscsi Target Wizard will appear. Select device type.

Chose Hard Disk. Press the Next button to continue.

Choose Image File in iscsi Medium Type page. Press the Next button to continue.

Chose Standard Image File in iscsi Image Type. Press the Next button to continue.

Select Create a new image file or Use existing image file if you already have one. Then specify the device size. Checking Use sparse file on NTFS file system will save your hard disk space by expanding image file depending on its content used. Press the Next button to continue.

Decide which authentication mechanisms you would want to use: Anonymous, CHAP, IP Filter or Mixed authentication. 1) Anonymous All initiators will get full access permission without any authorization required. 2) CHAP (Challenge handshake authentication protocol) All initiators need to specify a CHAP user and secret to connect to the target. istorage Server has a built in user called Guest, which is used for initiators without CHAP secret specified. 3) IP Filters All initiators will be authorized by the incoming IP address defined by IP Filter roles. 4) Mixed Security policy is determined by both CHAP and IP Filters. If you check Inherit security roles from global settings, all client security roles are form global settings, otherwise, each client will have its own permission. For purpose of this article, I will choose Anonymous. Press the Next button to continue.

Enter the name for your target device. If you check Report as readonly device when initiator cannot get write access, the system will give you a report when you load the target without write access. Press the Finish button to continue.

We successfully created iscsi Target. We can now connect to it using KernSafe WinCE iscsi Initiator.

Logging on to the target After installing KernSafe WinCE iscsi initiator on either WinCE or Windows Mobile device, please turn on Initiator. I will use Windows Mobile but the procedure on WinCE device is exactly the same. Adding portal To add a new portal, you can either tap and hold stylus in Portals group and choose Add Portal. Or you can access same option by taping on iscsi button, Portal >Add Portal.

When you will do it, you will be prompted to type IP address or DNS name. (Default port is 3260.) After finishing, tap on OK button to connect to the portal. You will notice that portal was successfully discovered as well as all targets within this portal.

You can add multiple portals to WinCE iscsi Initiator. NOTE: If you will type incorrect IP or DNS, portal won't appear on the list. Connecting to target You can connect to new target in two ways. First one is to tap and hold stylus on target name in target list, and choose Logon.

Or you can tap on target and then tap on iscsi button >Target >Logon. You will see new screen with all login information. Checking Automatically logon on startup option will result that target will be automatically mounted upon turning on the device. You may connect to as many targets as you want.

Upon successful connection to the iscsi Target, you will notice window asking to format new memory card. This is because we connected to RAW target that was created in istorage Server. This information will appear only for the first time using this target. Tap Yes to continue. You may now access this storage trough File Explorer.

Accessing data Upon successful connection to the iscsi Target, you can access data stored on it. You may now access this storage trough File Explorer. You can now copy, move and delete files to and from iscsi Target.

Logout from target To logout from target to what you are currently connected to, you can either tap and hold your stylus on that target and choose Logout. Or you can tap on target then tap on iscsi button and choose Target >Logout.

Then you will successfully logout from selected target. If you are connected to more then one target, and you wish to disconnect from all of them, you may do so by taping on iscsi button and choose Target >Logout All. That will result in logging out from all active targets.

Removing portal To remove portal, simply either tap and hold stylus on portal IP on the portals list, and choose Remove. Or tap on portal IP and tap on iscsi button and choose Portal >Remove.

Contact Support: support@kernsafe.com Sales: sales@kernsafe.com Marketing: marketing@kernsafe.com Home Page: http://www.kernsafe.com Product Page: http://www.kernsafe.com/product/istorage server.aspx http://www.kernsafe.com/product/wince iscsi initiator.aspx Licenses http://www.kernsafe.com/product/istorage server/license compares..aspx Forum: http://www.kernsafe.com/forumm KernSafe Technologies, Inc. www.kernsafe.com Copyright KernSafe Technologies 2006 2011. All right reserved.