Teranap TP Tanking System

Similar documents
HIGH PERFORMANCE PRE-APPLIED SYSTEM FOR BLIND SIDE & BELOW GRADE WATERPROOFING APPLICATIONS

SikaProof A Technology

WATERPROOFING SikaProof -A TECHNOLOGY

WATERPROOFING BASEMENTS

Waterproofing of Tunnels under Water Pressure

Construction. SikaProof A-08 Edge, A-12 Edge. Fully bonded FPO sheet membrane in L-shape for the SikaProof A waterproofing system. Product Description

WATERPROOFING SIKAPLAN MEMBRANE SYSTEMS FOR BASEMENTS TECHNOLOGY & CONCEPTS

INTERIOR WALLS AND BASEMENTS CHOOSING THE RIGHT MEMBRANE FOR INTERIOR WALLS. Multi-Layer Technology provides increased strength.

Sun-Activ - reflective SBS membrane. Sun-Activ - White reflective bituminous waterproofing membrane for Cool Roof

WATERPROOFING OF REINFORCED CONCRETE FLAT ROOF 12

BBA BRITISH. tanking. Application. Storage & Handling

Cavity Drain R20 is manufactured from1.0mm thick black high density polyethylene with studs approximately 20mm high.

Waterproofing construction Joints

Flexible Waterproofing of Basement Structures with Sikaplan Membranes

The assessment is described in the following pages which form integral parts of this certificate, which should be read in its entirety.

RIW SHEETSEAL 226 BENEFITS APPLICATIONS APPLIED TO. CI/SfB TN6 L6813. November l Water and water vapour barrier. l Factory controlled thickness

Chapter 3 Pre-Installation, Foundations and Piers

WATERPROOFING OF WET ROOMS

Monarflex Tanking & DPM Systems. Cold and Hot. Applied. Structural. Waterproofing. Membranes YEAR. Geomembr nes WORLD LEADER IN WATERPROOFING

WATERPROOFING PRODUCTS

METHOD STATEMENT 006 TORCH APPLIED MEMBRANE TO BASEMENT WALLS

EXTERNAL WATERPROOFING MEMBRANES BEST PRACTICE GUIDELINES

Gas Membrane and Waterproof Tanking Systems

DENSO WATERPROOFING SYSTEMS

Fosroc Proofex Engage

DRAINAGE MATS For Vertical: Flow 15-P For Horizontal: Flow 18-H

SIKABIT W-15 WET-BONDED WATERPROOFING MEMBRANE

Always. Reliable. Tight. Wall sleeves Versatile solutions for building entries. cablepipebuildingentry+

Waterproofing of tunnels under infiltrating water RENOLIT ALKORGEO. Underground structures

Section 5.0. Basements. Wall insulated externally. Wall insulated internally. Ba02. Product: Polyfoam ECO Floorboard Ba01.

After reading this lesson you will be able to: 12.3 IMPORTANCE OF ROOF 12.4 TYPES OF ROOF IN A HOUSE

USER GUIDE Easier, Safer, Betta! WATERPROOFING

WATERPROOFING SikaFuko INJECTION HOSE SYSTEMS UNIQUE WATERPROOFING SOLUTIONS FOR CONSTRUCTION JOINTS

Product Systems AQUAFIN-IC CEMENTITIOUS CRYSTALLINE PENETRATING WATERPROOFING. Waterproofing Specification

Corrosion protection linings. Issue 1

Barewood Octagon and Elongated Windows Installation Instructions

Issue of the Guidelines on Prevention of Water Seepage in New Buildings

What you need to know about concrete block basement construction.

SPECIFICATIONS FOR BRIDGE CONSTRUCTION SECTION 16 BRIDGE DECK WATERPROOFING General Materials Equipment...

ARCHITECTURAL TECHNOLGY 4 ADVANCED CONSTRUCTION TECHNOLOGY BASEMENT CONSTRUCTION YEAR 3 SEMESTER 1 AIDAN WALSH R Lecturer: Jim Cahill

The unit costs are based on the trend line of the 3 low bids for the average quantity.

The AQUAFIN Approach to Concrete Repair

LAYING BLOCK AND BRICK

Concrete Waterproofing Systems. Integral Protection.

THORO. Waterproofing Systems

WATERPROOFING FOR CONCRETE STRUCTURES

SECTION STORM DRAINAGE SYSTEM

ALKALI-RESISTANT WATERPROOFING AND DECOUPLING MEMBRANE UNDER CERAMIC TILES AND NATURAL STONE

LANGLEY S ROOF WATERPROOFING MEMBRANES PARADIENE/PARAFOR ROOF WATERPROOFING SYSTEMS

Designed and Engineered to Perform

Connex. Mortarless Masonry Block System

Membrane for tunnels and underground construction

RIW STRUCTURESEAL. Structureseal is a highly effective waterproofing composite, of high strength green coloured geotextile, and sodium bentonite.

Elastoseal EPDM Tanking System Waterproofing of basements, foundations and cut-and-cover tunnels

Interior Walls below and above ground OLDROYD THE ULTIMATE WATERPROOF MEMBRANE SYSTEM

Waterproofing below-ground with Proofex Engage. constructive solutions

Wecryl Waterproofing System under surfacing supplied by others

waterproofing products

GENERAL RUBBER LINING PRINCIPLES

ASHGHAL Interim Advice Note No. 004

NEGATIVE SIDE WATERPROOFING SYSTEMS FOR MASONRY AND CONCRETE

CHESTERFLEX ROOF WATERPROOFING MEMBRANES

Test report P 7013-E. InoPaz H2O. Pazkar LTD. Alon Tavor Industrial Zone AFULA / Israel. J. Magner Dipl.-Ing. N. Machill.

High Performance PSA in Sheet Membrane in Water Protection

Up-Down Construction Utilizing Steel Sheet Piles and Drilled Shaft Foundations

Highlights. Grace Around the World

Structural Retrofitting Process and Techniques

COPYRIGHT. Dincel Construction System Pty Ltd

CertainTeed. Self-Adhering Roof Systems for Low Slope Residential Roofs

SECTION CEMENT-MORTAR LINED AND COATED STEEL PIPE

constructive solutions Fosroc total waterproofing protection of below-ground structures

Waterproofing below-ground with Proofex Engage

Foundations 65 5 FOUNDATIONS. by Richard Chylinski, FAIA and Timothy P. McCormick, P.E. Seismic Retrofit Training

Memtec Single Ply PVC Membrane Roofing and Waterproofing Technology. Modern Efficient Performance Cost Effective Flat Roofing Systems

INSTALLATION RECOMMENDATIONS. Outdoor Rubber Tiles

Preprufe 160 Sheet Tanking and Waterproofing Membrane

Schlüter -KERDI-BOARD Substrate, structural panel, bonded waterproofing

Waterproofing System for Wastewater Tanks in Petrochemical Industries and Refineries

NCMA TEK CONCRETE MASONRY FOUNDATION WALL DETAILS. TEK 5-3A Details (2003)

Section 2100-Trenching and Tunneling

WESTERN COOL ROOF SYSTEMS Sustainable - Energy Efficient FLUID APPLIED REINFORCED ROOF SYSTEM

CERTIFICATE NAME OF PRODUCT MANUFACTURER PRODUCT DESCRIPTION CERTIFICATION PROCEDURE. No VTT C Date of issue , Updated July 1, 2011

How To Test A Wrap N Drain X Dampproofing System

Homeowner s Guide Foundation Water PenetrationTips TIPS TO IDENTIFY WATER PENETRATION PROBLEMS / CRACKING BASEMENTS

Laying the First Course. 1. Excavate the site and construct the footing.

12.1 Schlüter -KERDI-BOARD

WATERPROOFING DESIGNED FOR PROTECTION & DURABILITY

DELTA Premium Moisture Management Systems for Foundations.

SIKA TANKING MEMBRANES SIKAPROOF A MEMBRANES

INSTALLATION GUIDE. americanwick.com WICK (9425)

Foundation Experts, LLC Specializes in Foundation Repair and Waterproofing

THE COMPLETE WATER PROOFING SOLUTIONS

BITUMINOUS ROOF COATINGS, CEMENTS, PRIMERS AND ADHESIVES

Basement Waterproofing of New Structures

Construction. Sikadur-Combiflex. Sealing system for cracks and problem joints with large movements DESCRIPTION

ExTERNAL BASEMENT WATERPROOFING

Drainage Composites. The ready-made solution to sub soil drainage

Guide for SOLID CONCRETE BLOCK SEALS

The minimum reinforcement for the stem wall is the placement of:

CONCRETE FLOOR SLAB & CASTING BED CONSTRUCTION

Transcription:

Teranap TP Tanking System Unique waterproofing system for tanking A Comprehensive tanking system A Extra wide (2m and 4m) geomembrane for fast and safe application A High puncturing resistance due to a thick polyester reinforcement A Root resistant geomembrane due to its strong polyester film surfacing A Compartmentalization and injection fittings for total safety A Solutions for all structural details: expansion joints, pile caps, etc. A High resistance to hydrostatic pressure up to 7 bars (70m under water table) Description The Teranap Tanking System is composed of a SBS elastomeric bitumen geomembrane and a comprehensive range of components for structural details: Geotextile or Blackline LDPE membrane for mechanical protection; Teranap 431 TP extra wide waterproofing geomembrane; Parafor M3S covering strip on Teranap TP overlaps; Fonda + protection board; Terastop waterbar for compartmentilization; Injection Flanges and Tubes for easy detection of any leakage and for repair by gel injection; Terastop DA and Neodyl for waterproofing expansion joints. Each of these components is described on the following pages. A High performance tanking system with solid experience over 20 years

Teranap TP Tanking System Unique waterproofing system for tanking Application Horizontally: Blackline LDPE membrane or 100g/m² geotextile for mechanical protection, depending on the roughness of the ground after excavation; Teranap 431 TP waterproofing geomembrane loose-laid with torched sidelaps and end-laps; Parafor M3S covering strip torched on Teranap TP side-laps and in corners; Terastop A 240/4 waterbar directly torched on Teranap 431 TP waterproofing geomembrane, allowing partitioning into compartments (about 250m²) for reliable injection of gel in case of repairs; Injection flanges to be fixed (4 per compartment) and through connection pipes up to the box set at the nearest wall surface or column; Geotextile for mechanical protection; PE film before pouring the protection screed; Protection screed. Vertically: The Teranap Tanking System can be laid, either on permanent shuttering (secant piles, diaphragm wall, etc.), before building erection, or on structural walls after building erection: On permanent shuttering: the Teranap Tanking System is to be loose laid over a 100g/ m² non-woven polypropylene geotextile. Teranap 431 TP geomembrane can be applied in a single stage or in several stages for each basement floor, and fixed with a temporary mechanical fixing above each basement slab. The membrane will then be connected to the next floor. Teranap 431 TP geomembrane is to be protected by protection boards (torched over Teranap 431 TP). On structural walls: once coated with Siplast Primer, Teranap 431 TP geomembrane shall be fully torched with an intermediate row of nails and protected by Fonda protection board before backfill. Details: Expansion joints: Neodyl strip torched to Teranap 431 TP, then Terastop DA 240/4 waterbar torched to Neodyl strip. Pile caps: Parafor M3S and Teranap 431 TP membranes fully torched; then, pouring epoxy mortar on the pile heads.

Teranap 431 TP geomembrane Parafor M3S covering strip Teranap 431 TP Teranap 431 TP is an extra wide (2m or 4m) elastomeric bitumen waterproofing geomembrane comprising a thick polyester reinforcement. Its double protection by polyester film surfacing and polyester fabric reinforcement allows for loose-laid application on rough substrates. Its simple welding method by torching the overlaps is well suited to on-site work and to changing weather conditions. Characteristics Extra wide SBS elastomeric bitumen geomembrane: 4 times fewer joints to secure; High resistance to the most common potentially harmful chemicals present in the ground involved in tanking and in below grade jobs; Surfaced by anti-puncturing and root-resistant polyester film; Suitable for potable water storage (NSF listed); UV resistant; Withstands permanent hydrostatic pressure: up to 7 bars. Parafor M3S covering strips Parafor M3S is a high performance reinforced SBS elastomeric bitumen membrane for securing side-laps of Teranap 431 TP and in corners. A double joint security on a single layer solution. Membrane also used for details: pile caps, angle reinforcement, etc. Geotextile or Blackline LDPE Teranap 431 TP geomembrane + protection board Parafor M3S covering strip and reinforcement angle Terastop A 240/4 waterbar Parafor M3S and Teranap 431 TP Epoxy mortar on pile heads Injection flanges, pipes and access box Geotextile PE film Concrete screed

Fonda protection layer Studded membrane with: High resistance to compression due to the octagonal shape of the studs; Quick to apply; easy to cut with a cutter. Fonda Blackline LDPE geomembrane (optional) Can be used as an underfacing protection of the Teranap 431 TP waterproofing membrane, depending on substrate roughness after excavation. The laps are not welded. Good resistance to aggressive chemicals. Excellent UV resistance. Blackline LDPE Partitioning with Terastop A 240/4 waterbar The Terastop A 240/4 waterbar is used for partitioning into areas of 250m². Terastop A 240/4 waterbar is torched onto the Teranap 431 TP geomembrane. The junctions are end to end using heating blade cutting devices or hot air welding. Special junction elements: X, T and L are available. Melting of 2 elements with heating blade Waterbars: Terastop A 240/4, left and Terastop DA 240/4, right Details The Teranap Tanking System includes a number of accessories and technical solutions to deal with details encountered on a tanking job such as expansion joints and pile caps. Expansion joint with Terastop DA 240/4 waterbar and Neodyl strip. Expansion joints under the water table must be effectively structured with the following accessories: Neodyl strip fully torched to Teranap 431 TP: non-reinforced SBS elastomeric binder with 1,000% elongation. Ensures perfect continuity of waterproofing between structures. Terastop DA 240/4 waterbar: depending on the situation (slabs, walls), to be anchored in concrete or to be torched onto Neodyl strip. Injection System: flanges, pipes and boxes This Injection System, composed of flanges along with connection pipes linked to accessible boxes (set at the nearest wall surface or column), makes it easy to detect any leakage of the tanking and to correct this by injecting gels to stop water penetration. Usually 4 injection flanges and pipes are provided at each area for any necessary injections. The injection flanges must be partially fixed (glued or spot torched) to the Teranap 431 TP geomembrane. Patches of membrane can be welded between the injection flanges and the Teranap 431 TP for an easy liquid flow. For minor leakage, acrylic gel is usually applied. For major leakage, polyurethane gel is recommended. Injection flange with access box Pile caps The waterproofing details around the piles need to be executed very carefully at every point: all around piles up to the caps, between pile-caps and the building s bottom slab. Waterproofing pile caps: Parafor M3S and Teranap 431 TP fully torched. Pouring pile heads with epoxy mortar. Pile cap with Parafor M3S and Teranap 431 TP membrane followed by a layer of epoxy mortar

Teranap TP Tanking System Unique waterproofing system for tanking N3-33 06/11 Photos and illustrations : Icopal R.C.S. Nanterre B 552 100 984 The charts do not constitue a contractual document 12, rue de la Renaissance F-92184 Antony Cedex Tél. +33 (0)1 40 96 35 00 Fax. +33 (0)1 46 66 24 85 www.siplast-international.com Awarded to all sites of the company