SmarTek Systems, Inc.



Similar documents

CENTRONICS interface and Parallel Printer Port LPT

OPERATOR INTERFACE PRODUCTS APPLICATION NOTE. Xycom 4800/2000 OIL (Operator Interface Language)- Series Terminals: Backup and Restore with ProComm

Aquadyne TechTip TITLE: TROUBLESHOOTING PC COM PORT AND MODEM PRODUCTS AFFECTED SYMPTOMS POSSIBLE CAUSES

MSITel provides real time telemetry up to 4.8 kbps (2xIridium modem) for balloons/experiments

SLIP and PPP. Gursharan Singh Tatla

NVT (Network Virtual Terminal) description

Programming and Using the Courier V.Everything Modem for Remote Operation of DDF6000

Nokia for Business. Nokia and Nokia Connecting People are registered trademarks of Nokia Corporation

TAP Interface Specifications

OWNERS MANUAL. Status Monitor. for Windows 95, 98, ME, NT 4, 2000 & XP. SIGNALCRAFTERS TECH, INC.

LTM-1338B. Plus Communications Manual

Modbus Protocol. PDF format version of the MODBUS Protocol. The original was found at:

SMS Alarm Messenger. Setup Software Guide. SMSPro_Setup. Revision [Version 2.2]

2. Terminal arrangement. Default (PV display) (SV display) Communication protocol selection Selects the Communication protocol. Modbus ASCII mode:

Part 1. MAX BIT DAC with an Arduino Board. MIDI to Voltage Converter Part1

Remote login (Telnet):

PRT3 Printer Module: ASCII Protocol Programming Instructions

PROFIBUS AND MODBUS: A COMPARISON

Configuring Serial Terminal Emulation Programs

Sending SMS Messages and s

METEOROLOGICAL INSTRUMENTS

HOW TO USE YOUR INTELE-MODEM

Iridium Satellite Data Services White Paper. Version 1.0 June 2 nd 2003

SUDT AccessPort TM Advanced Terminal / Monitor / Debugger Version 1.37 User Manual

WA Manager Alarming System Management Software Windows 98, NT, XP, 2000 User Guide

MOTION COORDINATOR MC206X Quick Connection Guide

Modern Robotics, Inc Core Device Discovery Utility. Modern Robotics Inc, 2015

Process Control and Automation using Modbus Protocol

SATEL NMS PC USER MANUAL. SATEL NMS PC Version User Manual Version 2.5

SenseLink TM. End-Point Controller. Addendum

Wireless Communication With Arduino

Configuring connection settings

Evolution of the WWW. Communication in the WWW. WWW, HTML, URL and HTTP. HTTP Abstract Message Format. The Client/Server model is used:

Web Datalogger. Unit RS232C. General-purpose modem RS485. IP address search screen

Technical Manual. For use with Caller ID signaling types: Belcore 202, British Telecom, & ETSI

OWNER'S MANUAL MODEL V81 DAM-1

DT105X / PB105 Series

Application & Quick-Start Guide

Data Acquisition Module with I2C interface «I2C-FLEXEL» User s Guide

Sending MAC Address Function

Nokia E61i Configuring connection settings

Acoustical Surfaces, Inc.

This document explains how to use your Web Browser to configure the 100BaseT IOPRINT+ Print Server models. Connecting to the IOPRINT+ Print Server

This document explains how to use your Web Browser to configure the 100BaseT Print Server models

Modicon Modbus Protocol Reference Guide. PI MBUS 300 Rev. J

ND48-RS ASCII A2.04 Communication Protocol

NetProbe Lite. Web Based 8 Channel Sensor Collector. User Manual. Version 1.2

Retrieving data from IRIS/USGS stations

Test Driven Development of Embedded Systems Using Existing Software Test Infrastructure

Data Bulletin. Communications Wiring for POWERLINK G3 Systems Class 1210 ABOUT THIS BULLETIN APPLICATION INTRODUCTION.

Electronic Federal Tax Payment System. Easy Ways to Use EFTPS. For Tax Practitioners, Accountants and. Payroll Companies

Synergy Controller Application Note 4 March 2012, Revision F Tidal Engineering Corporation Synergy Controller Bar Code Reader Applications

Palomar College Dial-up Remote Access

Nokia and Nokia Connecting People are registered trademarks of Nokia Corporation

OBM (Out of Band Management) Overview

Date Rev. Details Author

SMS GSM Alarm Messenger

CONTROL MICROSYSTEMS DNP3. User and Reference Manual

SITRANS RD500 Configuring the RD500 with PSTN or GSM modems and Windows-based servers and clients for communication Objective:

RS232 Programming and Troubleshooting Guide for Turbo Controls

VeHiCle diagnostics the autocom way

Prestige 310. Cable/xDSL Modem Sharing Router. User's Guide Supplement

Issue 2EN. Nokia and Nokia Connecting People are registered trademarks of Nokia Corporation

Impulse G+/VG+ Series 3, 24 VDC Interface Card Terminal Designations

TSX ETZ Configuration of your computer for TSX ETZ direct connection by serial link. Eng V1.0

Windows Dial Up Networking (DUN) for AirLink Modems Application Note - How To

Thermal Control Board User Manual 1

How to integrate fuel monitoring into Fleet Management System

NETWORKING ALPHA SIGNS FOR THEATER SOLUTIONS v Single sign networks with AlphaNET plus, Alpha Messaging, or Simply Theater software

RS-232 Communications Using BobCAD-CAM. RS-232 Introduction

isco Connecting Routers Back to Back Through the AUX P

Coyote SP - Installation Notes

Parallax Serial LCD 2 rows x 16 characters Non-backlit (#27976) 2 rows x 16 characters Backlit (#27977) 4 rows x 20 characters Backlit (#27979)

Phantom4 Remote Management Module User s Manual

PC/POLL SYSTEMS Version 7 Polling SPS2000 Cash Register TCP/IP Communications

How To Use A Gps 130 With A Gps-130

Eaton Remote Monitoring Manual

Evolution of the WWW. Communication in the WWW. WWW, HTML, URL and HTTP. HTTP - Message Format. The Client/Server model is used:

DataMonitor Plug-in. DataMonitor Plug-in

Part Number Description Packages available

serial ASCII CES Wireless s principal activity is to provide mobile Ability to create flexible, custom

Timeout The Crosspoint Status Request message has a timeout, which means that you need to wait 1 second in between request messages.

Using HyperTerminal with Agilent General Purpose Instruments

OSBRiDGE 5XLi. Configuration Manual. Firmware 3.10R

Electronic Control Devices The European Product Catalogue 2007

RS232 Board datasheet

Swipe reader interfaces

CONTENT of this CHAPTER

AEI RAIL NETWORK SERVER User Manual

IBM Emulation Mode Printer Commands

Connected Vehicles: New Directions and Opportunities. AASHTO Connected Vehicle Task Force December 3, 2014 Irvine, CA. Leidos. All rights reserved.

Using Debug Commands

NortechCommander Software Operating Manual MAN R6

3.1 RS-232/422/485 Pinout:PORT1-4(RJ-45) RJ-45 RS-232 RS-422 RS-485 PIN1 TXD PIN2 RXD PIN3 GND PIN4 PIN5 T PIN6 T PIN7 R+ PIN8 R-

BARCODE READER V 2.1 EN USER MANUAL

Transcription:

S S TM TM SmarTek Systems, Inc. 14710 Kogan Drive Woodbridge, VA 22193 703-680-6554 Sales 410-315-9727 SmarTek Acoustic Sensor - Version 1 (SAS-1) Installation and Setup Guide Part-Y Communication Via Internet 25 September 2002 Note: In all cases, do not work or position equipment over an active traffic lane. Working over active lanes presents a hazard to the installer and to travelers using the highway. Follow local authorized procedures when installing the SAS-1 unit and any associated components or subsystems. Sensing and System Integration Solutions

(This Page Intentionally Left Blank) SmarTek Systems (www.smarteksys.com) 2

Detailed Protocol/Formats for Multiple Device Communication This document describes the communication protocol/format between data collection software running at a central facility and a roadside cabinet with multiple SmarTek SAS-1 traffic sensors and a SmarTek Cabinet Watchdog Voltage Monitor. Connectivity between the central facility and all roadside cabinets may be a network or the internet. Each cabinet may be connected to one or more SAS-1 traffic sensors (SAS0001, SAS0002, etc.) and a Cabinet Watchdog Voltage Monitor. Each of these devices must be set during installation to operate in the polled mode since they all share a common serial communication line to the system interface (CDPD modem, serial device server, dialup modem, etc.). This interface implements the communication link back to the central facility. The following section describes the required polling command which is sent to each cabinet and the resulting data message response format from each device connected to the system interface in the roadside cabinet. The response order is also shown. This protocol description applies to SAS-1 software Version SAS_140 or later. Global Broadcast Command To Each Roadside Cabinet: Example: <ESC>{SAS0000,FLOW=Chr(33),Mess_Format} Mess_Format = Chr(33) for Simple Flow, Chr(34) for Flow with Truck Count ASCII Chr(33) is! and Chr(34) is <ESC> is ASCII Chr(27) or <ESC>{SAS0000,FLOW=!,!} <ESC>{SAS0000,FLOW=!, } (Poll Command: Simple Flow Message) (Poll Command: Message with Truck Count) Response from Roadside Cabinet (SAS-1s and Cabinet Watchdog) For Mess_Format=Chr(33): First: Chr(2)CWD0001<sp>aa.aaa<sp>bb.bbb<sp>cc.ccc<sp>dd.ddd<sp>efghijkl<CR><LF>Chr(3) SmarTek Systems (www.smarteksys.com) 3

Chr(2)SAS0001<sp>PPP<sp>LL<sp>VVV<sp>OOO<sp>SSSS<CR><LF> (Lane 1 data) Chr(2)SAS0002<sp>PPP<sp>LL<sp>VVV<sp>OOO<sp>SSSS<CR><LF> (Lane 1 data) Chr(2)SAS0003<sp>PPP<sp>LL<sp>VVV<sp>OOO<sp>SSSS<CR><LF> (Lane 1 data) Chr(2)SAS0004<sp>PPP<sp>LL<sp>VVV<sp>OOO<sp>SSSS<CR><LF> (Lane 1 data) Etc. For Mess_Format = Chr(34) the SAS-1 Response Format is shown below. The Response Sequence and the Cabinet Watchdog Voltage Monitor Format are unchanged. Chr(2)SASxxxx<sp>PPP<sp> Chr(3) SmarTek Systems (www.smarteksys.com) 4

For the SAS-1 Message Format, the following applies: PPP is the message position in the SAS-1 FIFO buffer, LL is the lane number, VVV is the total vehicle volume or count, UUU is the commercial truck count, WWW is the tractor-trailer count, OOO is lane occupancy in percent, SSSS is average speed in mph. Spaces (ASCII Chr (32)) in the format are designated as <sp> while <CR> and <LF> represent carriage return (ASCII Chr(13)) and line feed (ASCII Chr(10)) respectively. Chr (2) and Chr(3) are the start of message and end of message characters. Note that this entire message is ASCII. PPP indicates whether the message is current (PPP=1), or old and should be dropped (PPP=0), or behind (PPP>1). If the Poller is behind, the SAS-1 should be immediately repolled (and the message kept) until PPP=1. For the Cabinet Watchdog Voltage Monitor Message Format, the following applies: aa.aaa is the analog voltage measurement (volts) at pin AI1 on J2, bb.bbb is the analog voltage measurement (volts) at pin AI2 on J2, cc.ccc is the analog voltage measurement (volts) at pin AI3 on J2, dd.ddd is the analog voltage measurement (volts) at pin AI4 on J2, e is the state of the isolated input at pins AK2, KA2 on J4 (e=0 or 1), f is the state of the isolated input at pins AK1, KA1 on J4 (f=0 or 1), g is the state of the TTL input at pins 11, 12 on J3 (g=0 or 1), h is the state of the TTL input at pins 9, 10 on J3 (h=0 or 1), i is the state of the TTL input at pins 7, 8 on J3 (i=0 or 1), j is the state of the TTL input at pins 5, 6 on J3 (j=0 or 1), k is the state of the TTL input at pins 3, 4 on J3 (k=0 or 1), l is the state of the TTL input at pins 1, 2 on J3 (l=0 or 1) SmarTek Systems (www.smarteksys.com) 5