Using Petrifilm in Student Microbiology Studies

Similar documents
Aerobic Count. Interpretation Guide. 3M Food Safety 3M Petrifilm Aerobic Count Plate

Lab Exercise 3: Media, incubation, and aseptic technique

Transferring a Broth Culture to Fresh Broth

ENUMERATION OF MICROORGANISMS. To learn the different techniques used to count the number of microorganisms in a sample.

Presentation at the 3 rd SAFOODNET seminar

EUROTUBO DELTALAB 4. PETRI DISHES AND LOOPS

National Food Safety Standard Food microbiological examination: Aerobic plate count

Total Aerobic Bacteria, Yeasts and Molds

LAB 4. Cultivation of Bacteria INTRODUCTION

3M Food Safety. Quality Solutions. for. Testing Times

3M Food Safety. Innovative Solutions. that Enable Food Safety. ProcessingSafety

3M Food Safety 3M Petrifilm Plates and 3M Petrifilm Plate Reader

Lab Exercise 2 Media and Culture

Transformation of the bacterium E. coli. using a gene for Green Fluorescent Protein

How to Prepare Formula for Bottle-Feeding at Home

Bacterial Transformation with Green Fluorescent Protein. Table of Contents Fall 2012

BACTERIAL ENUMERATION

Transformation Protocol

Laboratory Biosafty In Molecular Biology and its levels

In order to be useful, a smear must have the following qualities:

VC 104+ Rigid Grade / Rigid Grade Imagine VC 104 Rigid Grade Commercial Customised

Transformation Kit BACTERIAL TRANSFORMATION: GREEN FLUORESCENT PROTEIN. Partnership for Biotechnology and Genomics Education

How to Prepare Powdered Infant Formula in Care Settings

Microbiological Analysis

Biological Sciences Initiative

Disc Diffusion Susceptibility Methods

Quantifying Bacterial Concentration using a Calibrated Growth Curve

General food hygiene rules

Policies. Prep Room Policies

Contaminant. Publication Order Number. EPA Publication Number. Method. Date. Source of Method. Total Coliforms

Gel Electrophoresis Teacher Instructions Suggested Grade Level: Grades 7-14 Class Time Required: 1 period (50 minutes)

Testing Waste Water for Fecal Coliforms and/or E.coli using Colilert and Colilert -18 & Quanti-Tray

THE UNIVERSITY OF NEWCASTLE- SCHOOL of BIOMEDICAL SCIENCES

Enzyme technology ACTIVITY BRIEF. Enzymes. The science at work

Blood Collection and Processing SOP

COMMON LABORATORY APPARATUS

Potato Microbiology. Sarah Follenweider, The English High School 2009 Summer Research Internship Program

Upgrading of Agro-wastes to Straw Mushroom by Radiation

SDS-PAGE Protocol Mutated from the SDS-PAGE protocol written by the Lord of the Flies

ENVIRONMENTAL LABORATORY APPROVAL PROGRAM CERTIFICATION MANUAL

ClikSTAR - Important facts about your new insulin delivery device.

Chapter 10 - MICROBIOLOGICAL ANALYSES

Hands-On Labs SM-1 Lab Manual

Quality Assurance (QA) & Quality Control (QC)

Mixtures and Pure Substances

Microbiological Testing of the Sawyer Mini Filter. 16 December Summary

How to prepare your baby s bottle feed

1. Initial Precautions 2. Technical Precautions and Suggestions 3. General Information and Cure Stages 4. Understanding and Controlling Cure Time

Aseptic Technique. A GMP/GTP Training Module

BUGS" THAT PRODUCE DRUGS TO KILL "BUGS Microbes Produce Antibiotics

TEACHER ACTIVITY GUIDE

1. Preparing thin and thick blood films with capillary or venous blood

Welcome to Implementing Inquirybased Microbial Project. Veronica Ardi, PhD

TURKISH FOOD CODEX COMMUNIQUÉ ON RAW MILK AND HEAT PROCESSED DRINKING MILK (Communiqué Number: 2000/6)

Inc. Wuhan. Quantity Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4 Standard (liquid) 2

Fiber Analysis 2005, 2004, 2003, 2001, 1999 by David A. Katz. All rights reserved.

Private Water Supplies Sampling Manual. A Field Guide

Tassimo The Art of the Perfect Cup

Environmental Monitoring

TAKING CARE OF WOUNDS KEY FIGURE:

Related topics: Application Note 27 Data Analysis of Tube Formation Assays.

Lab Safety and Standard Operating Procedures. Faculty of Dentistry And School of Biomedical Engineering

PURE CULTURE TECHNIQUES. To demonstrate good aseptic technique in culture transfer or inoculation and in handling sterile materials.

Environmental Monitoring

IDENTIFICATION OF POLYMERS 1998 by David A. Katz. All rights reserved

Instructions for Use

ph Measurements of Common Substances

STANDARD OPERATING PROCEDURES Safe Autoclave Operations

Precautionary Boil Water Notices: Frequently Asked Questions

THE ACTIVITY OF LACTASE

UTILIZATION of PLASMA ACTIVATED WATER in Biotechnology, Pharmacology and Medicine. JSC TECHNOSYSTEM-ECO Moscow, Russia April, 2009

Introduction 1 The system 1 The meter 2 The display 3 The mode 3 The measurement 4 Coding the meter 4 How to obtain a drop of blood 6 Application of

Biosafety Spill Response Guide

DETECTION OF BACTERIAL MOTILITY. To demonstrate bacterial motility by microscopic and macroscopic techniques.

Biosafety Level 2 (BSL-2) Safety Guidelines

A Guide to Trouble-Free Cooling Towers

Culture Media Preparation Review ( Modified from Supplemental Lecture by Stephen T. Abedon)

STANDARD OPERATING PROCEDURES SPILL RESPONSE AND CLEAN-UP OUTSIDE BIOSAFETY CABINET

HEALTH AND SAFETY IN THE FOOD INDUSTRY DETECTING HARMFUL MICROORGANISMS HEALTH AND SAFETY PRECAUTIONS (EXAMPLES FROM CONQUEST FOODS)

Catalytic Activity of Enzymes

Protocol for Disinfection of Cell Culture and Tissue Culture in Media:

Biotechnology. Unit 2: Microbiological Techniques. Student Materials [HIGHER] Margot McKerrell. abc. Learning and Teaching Scotland

Learning to Self Inject Methotrexate at Home Developed by Andy Thompson MD FRCPC and Marie J Craig-Chambers B.Sc.Phm

Environmental Monitoring of Clean Rooms

In this experiment, we will use three properties to identify a liquid substance: solubility, density and boiling point..

Protection for hand eczema

Steam Sterilization Cycles for Lab Applications

Archived. Gloves should be changed frequently during the analysis.

1. The Determination of Boiling Point

Water and Wastewater. Sample Collection and Analysis

Infectious Waste Management Plan

LABORATORY ORGANIZATION

EH&S. Sheet. Fact. Safe and Effective Use of Autoclaves. What are autoclaves? Factors for effective sterilization. Dry heat cycle - when to use

North Carolina State University Emergency Facilities Closure Checklist- Part I

Physical and Chemical Changes

ArtisanLink Staining System is an automated special stains slide

Test Method for the Continuous Reduction of Bacterial Contamination on Copper Alloy Surfaces

Paper Chromatography: Separation and Identification of Five Metal Cations

Hazardous Drugs Spill Kit

Using a Pendulum to Measure Gravity s Acceleration Elizabeth B. Chesick

Transcription:

Using Petrifilm in Student Microbiology Studies a world of learning Presented by Peter J Ball, Southern Biological. For further information, please contact the author by phone (03) 9877-4597 or by email peterjball@southernbiological.com. Introduction Microbiology involves working with organisms that are too small to see in normal circumstances. As a result, special techniques, methods and apparatus are usually required. In particular, special agar gel substrates are often employed to grow microorganisms. This workshop presents Petrifilm, an alternative growth substrate made by 3M Corporation. What is Petrifilm? A Petrifilm plate is a thin film, sample ready, dehydrated version of the conventional Petri dish agar plate. Petrifilm is widely used in the food industry throughout the world to monitor quality and to audit cleaning and sterilisation processes. Foods, beverages and surfaces can be tested for the presence of harmful bacteria (pathogens), indicator bacteria (that indicate the possible presence of pathogens), and spoilage organisms that can affect the shelf-life. The advantages of Petrifilm include: Ready to use no preparation required Long shelf life when shielded from moisture and humidity Simple to use and interpret Built-in biochemical confirmation Smaller (thinner) and less likely to be damaged than agar plates. Types of Petrifilm There are many types of Petrifilm, each formulated and designed for a specific purpose. Of the total number available, four are suggested for use in education. Other types that are used in industry to isolate known pathogens are regarded as unsuitable for use by students. Aerobic Count (AC) Plate Designed to enumerate common aerobic bacteria. The AC plate contains Standard Methods nutrients, a cold water gelling agent, and triphenyl tetrazolium chloride (TCC), an indicator that colours bacterial colonies red.

Page 2 Coliform Count (CC) Plate Designed to enumerate coliform bacteria. Coliforms are members of the family Enterobacteriacea which ferment lactose to produce gas. Coliforms are an indicator of faecal contamination, particularly in dairy products. The CC plate contains violet red bile (VRB) lactose nutrients, a cold water gelling agent and triphenyl tetrazolium chloride (TTC), an indicator that colours bacterial colonies red. E.coli/Coliform Count (EC) Plate Counts all coliforms in a sample and differentiates E. coli as a subset of the total. The EC count is an indicator of faecal contamination, particularly in meat products. The EC plate is essentially the same as the CC plate, except that it contains the BCIG chromogenic indicator. Yeast and Mould Count (YM) Plate Designed to count all common yeast and mould species in a sample. The YM plate contains modified Sabroud s Dextrose nutrients in a cold water gelling agent, a dye to enhance the visualization of growth on the plate (colours all yeasts aqua green), and two broad spectrum antibiotics to suppress bacterial growth. Using Petrifilm Petrifilm is supplied in sealed packs that should be kept cool and dry. Storage in the dry atmosphere of a freezer is recommended, but ensure you allow the pack to warm up to room temperature before opening to avoid condensation forming. Take out just the plates you will need for a piece of work, then reseal the pack and put it back in the freezer. For detailed descriptions of sample preparation, inoculation methods, incubation conditions and interpretation of results, visit www.southernbiological.com then follow the links: Catalogue - Kits & Equipment - Petrifilm - Petrifilm Plates and Accessories. From here, you can click through each product code for access to detailed information. Testing Liquids Liquids such as orange juice, milk or water can be tested directly by inoculating the Petrifilm plate with 1mL and incubating. If the count is too high, you should dilute the sample then correct for the dilution factor when expressing the result. For information on serial dilution, download the Tips on Sample Preparation Serial Dilution sheet from our website. Testing potable water can be problematic because standards require no E.coli per 100mL of water. In practical terms, this means you would have to perform 100 tests with EC plates because each plate uses only 1mL of water. It is possible to use a sterile filtration system to concentrate a volume of water for testing, but for student demonstrations, it is more usual to dose a water sample with an E.coli culture to ensure a positive result.

Page 3 Testing Solids Solids need to be macerated in sterile liquid to extract microorganisms before they can be tested, but once this has been done, the plate can be inoculated with 1mL of the extract. For detailed instructions, download the Coliform Information Insert sheet from our website (follow links from product code M6410). Testing Surfaces Two approaches are possible when using Petrifilm to test for the presence of microorganisms on surfaces. One method is to swab an area, and then to extract the swab with sterile liquid that can be tested. This is useful when testing irregular surfaces such as a tap, door handle, light switch or hand. The 3M Quick Swab (M6432) is a self-contained ready-to-use surface swab system, otherwise you can use a sterile cotton wool or rayon swab held with sterile forceps. The second method is direct contact with a Petrifilm plate. This is suitable for smooth regular surfaces such as bench tops and floors, and even the surface of the skin. In order to activate the plates, they need to be hydrated with 1mL of sterile liquid before contact. Hydrated plates should be allowed to gel for at least one hour, but can be stored under refrigeration for up to a week before being used to test a surface. For more information, visit our website. Testing the Atmosphere By taking a hydrated plate and peeling back the protective film, you can expose the activated surface of the plate to the air to check for the presence of airborne microorganisms. For example, compare different air conditioner outlets. For a description of the experimental method, download the Yeast & Mould Information Insert sheet from our website (follow links from product code M6407). Student Experiments Petrifilm plates are suitable for many student experiments because of their ease of use and versatility. As well as meeting outcomes in the field of microbiology, the use of Petrifilm touches on areas such as maths (dilution and correction factors, calculations, scaling and statistics), scientific experimental design, and use of laboratory equipment. Download a copy of the Petrifilm Experiment Manual from our website (follow the link from any of the product codes). Accuracy and Precision Microbiology is a branch of science that is concerned with accuracy but not so much with precision. Even though Petrifilm plates are designed for counting and enumeration of microorganisms, it is usual to speak in terms of tens or hundreds rather than giving precise numbers such as 47 or 163. All Petrifilm plates are calibrated to receive 1mL, so it is acceptable to use plastic Pasteur pipettes, and there is no need to discard plates that might have a slightly irregular gel shape.

Page 4 Sterile Technique All microbiological procedures require sterile methods to avoid contamination that would interfere with the determinations being made. Basic measures include: Wash hands thoroughly before and after each procedure. Tie back hair. Swab the work surface with 70% ethanol before starting work. Leave wet and allow to evaporate dry. Use a Bunsen flame to form a heat curtain to shield the work area from airborne microorganisms. Use economical movements and minimize the time that surfaces and samples are exposed. When mixing or diluting samples, it is acceptable to use well boiled water that has been allowed to cool. For macerating food samples, you can get good results in a fresh polythene lunch bag. Provided they haven t been opened, these bags can generally be considered as sterile for the purpose of school experiments. To check for the presence of a background level of microorganisms in the water and/or bag, run a control that substitutes sterile liquid for the test substance. Safety and Disposal Following inoculation, plates should be taped shut or placed in a press-seal bag to keep them isolated. Follow good laboratory practice and have students thoroughly wash their hands after handling microbiological samples and equipment. Adequate antibacterial hand wash and hand rub sanitizer solutions should be provided. Treat plates with viable colonies as you would deal with cultures on conventional Petri dishes. Autoclave or soak in a suitable biocide, e.g. 10% bleach solution. Alternatively, you can use a contract collection service such as that provided by Stericorp. Trouble Shooting The most common problems we have seen tend to occur with novice users of Petrifilm, but they are easily avoided: Dispensing more than 1mL of liquid If you accidentally draw more than 1mL of liquid into the pipette and dispense it onto the Petrifilm plate, it will overflow off the plate when the spreader is applied. Be careful to apply only 1mL. Having the liquid roll off the plate as it is being applied This can occur if you hold the pipette at a low angle. Place the Petrifilm plate on a flat surface and hold the pipette perpendicular to the surface, in the central region. Dispense the liquid onto the plate with care.

Page 5 Waiting too long Have the plate, spreader and sample to be tested ready, and apply the spreader without delay after dispensing the sample onto the plate. Proper spreading may not occur if you wait too long between dispensing the liquid and applying the spreader. Trapping bubbles on the plate First of all, ensure the sample does not have entrained air bubbles. Allow it to stand if necessary to allow bubbles to clear. As a further measure, use the recommended method to lower the protective film back onto the plate after dispensing the sample. For the AC and YM plates, allow the film to drop back into place. For the CC and EC plates, roll the film gently back into place. Using the wrong spreader Ensure you use the correct spreader. For YM plates, use only the special (larger size) Yeast and Mould Plate Spreader. For AC plates, use the General Purpose Spreader with the ridge side down (smooth side up). For CC and EC plates, use the General Purpose Spreader with the smooth side down (ridge side up). Getting contamination Avoid contamination by planning your work and using good aseptic technique and sterile equipment. This applies to all microbiological work, not just Petrifilm. Further Information The key to good results with microbiology experiments is familiarity with the equipment, confidence in the techniques, and respect for the safety aspects. For more information, contact us or attend a hands-on practical workshop session at a forthcoming conference or seminar. See the Events section of our web site for times and locations.